• Title/Summary/Keyword: Alkali-metal ion

Search Result 145, Processing Time 0.02 seconds

Characterization and the Catalytic Properties of Alkali- Exchanged Y-Zeolites on NOx Conversion (알칼리 이온 교환 Y-제올라이트의 NOx 전환에 대한 촉매 특성 및 반응성)

  • Lee Chang-Seop;Lee Kyung Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.2 s.27
    • /
    • pp.50-55
    • /
    • 2005
  • The compositional and structural properties of alkali metal ion exchanged Y-zeolites have been investigated by la number of analytical techniques and their catalytic activities were tested for NOx reduction in combination with a non-thermal plasma. The NOx conversion data for LiY, NaY, KY and CsY were measured by chemiluminiscent NOx meter in the temperature range of 100 to $350^{\circ}C$. The initial activities of the catalyst at $150^{\circ}C$ increased in the order LiY < KY < NaY < CsY in alkali series. The activity of CsY and NaY were increased and showed maximum at $200^{\circ}C$ and then decreased in the plasma reactor, as the temperature increased. The activity of KY maintained same by $200^{\circ}C$ and then decreased, whereas the activity of LiY decreased with the increasing temperature. The CsY catalyst, which showed the highest activity in alkali metal series, exhibits a NOx conversion efficiency of $80\%$ between $170{\~}220^{\circ}C$.

  • PDF

UO22+ Ion-Selective Membrane Electrode Based on a Naphthol-Derivative Schiff's Base 2,2'-[1,2-Ethandiyl bis(nitriloethylidene)]bis(1-naphthalene)

  • Shamsipur, Mojtaba;Saeidi, Mahboubeh;Yari, Abdullah;Yaganeh-Faal, Ali;Mashhadizadeh, Mohammad Hossein;Azimi, Gholamhasan;Naeimi, Hossein;Sharghi, Hashem
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.629-633
    • /
    • 2004
  • A new PVC membrane electrode for $UO_2^{2+}$ ion based on 2,2'-[1,2-ethanediyl bis (nitriloethylidene)]bis(1-naphthalene) as a suitable ionophore was prepared. The electrode exhibites a Nernstian response for $UO_2^{2+}$ ion over a wide concentration range ($1.0{\times}10^{-1}-1.0{\times}10^{-7}$M) with a slope of 28.5 ${\pm}$ 0.8 mV/decade. The limit of detection is $7.0{\times}10^{-8}$M. The electrode has a response time of < 20 s and a useful working pH range of 3-4. The proposed membrane sensor shows good discriminating abilities towards $UO_2^{2+}$ ion with regard to several alkali, alkaline earth transition and heavy metal ions. It was successfully used to the recovery of uranyl ion from, tap water and, as an indicator electrode, in potentiometric titration of $UO_2^{2+}$ ion with Piroxycam.

Purification and Analysis of Pectins (펙틴의 정제 및 분석)

  • 황재관
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.22 no.4
    • /
    • pp.500-509
    • /
    • 1993
  • Pectins present in the primary cell walls and middle lamellae of plant cell walls are extracted by water, cheating agents, acid or alkali solutions. However, some neutral contaminating components are extracted in conjunction with pectins during the extraction process. Thus, the accurate characterization of physi-cochemical properties of pectins necessitates to get rid of the impurities. In this review, dialysis, alcohol precipitation, ion exchange chromatography and metal precipitation were compared as procedures to purify the pectin extracts. In addition, the chemical methods to analyze pectins are discussed in terms of three major chemical constituents, i.e., anhydrogalacturonic acid, methoxyl groups and neutral sugars.

  • PDF

Development of a Mass Transfer Model and Its Application to the Behavior of the Cs, Sr, Ba, and Oxygen ions in an Electrolytic Reduction Process for SF

  • Park ByungHeung;Kang Dae-Seung;Seo Chung-Seok;Park Seong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.85-93
    • /
    • 2005
  • Isotopes of alkali and alkaline earth metals (AM and AEM) are the main contributors to the heat load and the radiotoxicity of spent fuel (SF) . These components are separated from the SF and dissolved in a molten LiCl in an electrolytic reduction process. A mass transfer model is developed to describe the diffusion behavior of Cs, Sr, and Ba in the SF into the molten salt. The model is an analytical solution of Fick's second law of diffusion for a cylinder which is the shape of a cathode in the electrolytic reduction process. And the model is also applied to depict the concentration profile of the oxygen ion which is produced by the electrolysis of Li$_{2}$O. The regressed diffusion coefficients of the model correlating the experimentally measured data are evaluated to be greater in the order of Ba, Cs, and Sr for the metal ions and the diffusion of the oxygen ion is slower than the metal ions which implies that different mechanisms govern the diffusion of the metal ions and the oxygen ions in a molten LiCl.

  • PDF

MAS-NMR Studies in Mixed Alkali Silicate Glasses with low Fe2O3 Content (미소량의 Fe2O3를 첨가시킨 혼합 알칼리 Silicate 유리들의 MAS-NMR 연구)

  • Kang, Myoung-Jin;Shim, Moon-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.1-14
    • /
    • 1996
  • The mixed alkali silicate glasses doped 0.1 mol% $Fe_2O_3$ are fabricated for studying the effect of transition metal oxides, which is related to the $Li^-$ ion movement in Magic-Angle-Spinning NMR. We have investigated the spin-lattice relaxation times in the room temperature and measured the $^7Li$ MAS-NMR spectrum with temperature. When the $Fe_2O_3$ oxides are added in alkali silicate glasses, the width of spectrum is changed a little but the line shape is hardly varied. For this reason, we can think that the mixed alkali effects are shown sufficiently in the spin-spin relaxation processes. However, it is not mixed alkali effects in this case. The activation energy of $Li^-$ ions are diminished in mixed alkali glasses. From the analysis of $Li^-$ diffusion environment, spin-lattice relaxation time and the nuclear magnetization, it is confirmed that the alkali mixed effects are not shown in $^7Li$ spin-lattice relaxation processes.

  • PDF

Atomic structure of Ba layer on Si(001)-(2$\times$1)

  • W.S. Cho;Kim, J.Y.;D.S. Koo;K.H.Chae;C.N.Whang;Kim, S.S.;Park, D.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.149-149
    • /
    • 2000
  • Alkali and alkali-earth metal on si(001) surface has been investigated widly for both scientific and technological aspects. In particular, the Ba/Si(001) system has been studied by several groups and they reported many phases such as (2$\times$3), (2$\times$4) and c(6$\times$2) 표 LEED and AES for various temperature and coverages. But there has not been the result of the atomic structure for these phases. Recently some works about the atomic structure of Ba/Si(001) at only room temperature were presented. In this study, we investigated 3-dimensional atomic structure and growth mode of Ba layer on si(001) by coaxial impact collision ion scattering spectroscopy (CAISS) at room temperature and high temperature.

  • PDF

Potentiometric Characteristics of Ion-Selective Electrodes Based on Upper-Rim Calix[4]crown Neutral Carrier

  • 강유라;오현준;이경문;차근식;남학현;백경수;임혜재
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.2
    • /
    • pp.207-211
    • /
    • 1998
  • Potentiometric characteristics of DOS plasticized PVC-based membranes containing upper-rim calix[4]crown neutral carrier to various metal cations and protonated alkylamines have been examined. Although the calix[4]crown-based membrane electrodes exhibited substantial emf responses to alkali and alkaline earth metal cations, their high detection limits (- log[Cs+]=4.5) and sub-Nernstian response slopes (48 mV/pCs+) to the most selective cation, cesium, indicate that the metal cation complexing ability of calix[4]crown is much weaker than that of macrocyclic crown ethers. However, the calix[4]crown-based membrane electrodes exhibited near-Nernstian response slopes (56 mV/decade for hexylNH3+) with low detection limits (log[hexylNH3+]= - 6.7) to most alkylammonium ions compared to those of blank (DOS plasticized PVC membrane with no ionophore) or crown ether-based membranes. While the selectivity patterns of blank and crown ether-based membranes are determined primarily by the lipophilicity of alkylammonium ions, the membranes doped with calix[4]crown ionophore could effectively discriminate the steric shapes of nonpolar alkyl groups of alkylammonium ions.

Diffusion Coefficients and Membrane Potential within Carrier Membrane by Reverse Transport System

  • Yang, Wong-Kang;Jeong, Sung-Hyun;Lee, Won-Chul
    • Korean Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.36-40
    • /
    • 2002
  • The diffusion coefficients of ions in the reverse transport system using the carrier mediated membrane were estimated from the diffusional membrane permeabilities and the ion activity in membrane system. In the aqueous alkali metal ions-membrane system diffusional flux of alkali metal ions driven by coupled proton was analyzed. The aqueous phase I contained NaOH solution and the aqueous phase II also contained NaCl and HCl mixed solution. The concentration of Na ions of both phases were $10^{0},\;10^{-1},\;10^{-2},\;5{\times}10^{-1}\;and\;5{\times}10^{-2}\;mol{\cdot}dm^{-3}$ and the concentration of HCI in aqueous phase II was always kept at $1{\times}10^{-1}\;mol{\cdot}dm^{-3}$. Moreover, the carrier concentration in liquid membrane was $10^{-2}\;mol{\cdot}dm^{-3}$. The results indicated that the diffusion coefficients depend strongly on the concentration of both phases electrolyte solution equilibriated with the membrane. The points were interpreted in terms of the energy barrier theory. Furthermore, eliminating the potential terms from the membrane equation was derived.

The Potentiometric Performance of Mercury (II) Ion-Selective Electrode Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Rhee Paeng, In-Sook
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.1
    • /
    • pp.59-63
    • /
    • 2008
  • Poly (vinylchloride) (PVC) membrane electrodes based on neutral carrier, tetracycline was prepared as an active sensor for Hg(II) ion, and tested in different contents of the potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as lipophilic salt. Bis (2-ethylhexyl) sebacate (DOS), bis(l-butylpentyl) adipate (BBPA), 2-nitrophenyl octyl ether (NPOE) and dibutyl phthalate (DBP) were used as diverse plasticizing solvent mediators. This electrode shows excellent potentiometric response characteristics and display good linearity with log $[Hg^{+2}]$ versus EMF response, over a range of concentrations between $10^{-7}$ and $10^{-3}M$. With 30.8mV/decade Nernstian slope, the detection limit was $6.9{\times}10^{-9}M$ and the response time was less than 20s. The proposed electrode yields very good selectivity for mercury (II) ion over many cations such as alkali, alkaline earth, transition and heavy metal ions. And it shows a very stable potential values in a wide pH range. This reliable electrode prepared was kept at least a month without considerable alteration in their response to Hg (II) ion.

Tallium(I) Ion-Selective Electrodes Based on Crown Ethers (크라온에테르를 이용한 탈륨(I) 이온 선택성 전극)

  • Sung Min Kim;Sung Uk Jung;Jineun Kim;Jae Sang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.8
    • /
    • pp.773-778
    • /
    • 1993
  • Poly(vinyl chloride)(PVC) membrane electrodes based on the lipophilic neutral carrier, dibenzo-18-crown-6(DB18C6) and benzo-15-crown-5 (B15C5) as the active sensors for Tl$^+$ ion have been prepared and tested in different content of the potassium tetrakis(4-chlorophenyl)borate (KTClPB) as lipophilic salt. Dioctyl adipate (DOA), 2-nitrophenyl phenyl ether (NPPE) and o-nitrophenyl actyl ether (NPOE) were used as plasticizing solvent mediators. Electrodes exhibited good linear responses of 40∼55 mV decade$^{-1}$ for Tl$^+$ ion within the concentration ranges 10$^{-1}$∼10$^{-5}$M TlNO$_3$. Selectivity coefficients of interfering ions (alkali metal, alkaline earth metal and some transition metal ions) for Tl$^+$-ISE were determined by separate solution method and were sufficiently small for most of them. These crown ether type ion-selective electrodes are suitable for use with aqueous solution at pH > 3.

  • PDF