• Title/Summary/Keyword: Alkali metal

Search Result 405, Processing Time 0.025 seconds

DSC Analysis on Water State of Salvia Hydrogels

  • Yudianti, Rike;Karina, Myrtha;Sakamoto, Masahiro;Azuma, Jun-Ichi
    • Macromolecular Research
    • /
    • v.17 no.12
    • /
    • pp.1015-1020
    • /
    • 2009
  • The role of the water structure present in hydrogels from nutlets of three species of salvias, S. miltiorrhiza (SM), S. sclarea (SS) and S. viridis (SV), was analyzed by differential scanning calorimetry (DSC). The sharp endothermic peaks that appeared at $5.9^{\circ}C$ (SM), $2.8^{\circ}C$ DC (SS) and $1.8^{\circ}C$ (SV) in each 1.0% hydrogel of 10.4-15.8% were not affected by addition of 0.1 M urea and alkali-metal salts. The order-disorder portions in the network were slightly affected by the distribution of freezable and non-freezable water in the hydrogel networks. The SV hydrogel was further used to investigate the effects of additives (0.1-8.0 M urea and 0.1-5.0 M NaCl) on its melting behavior. At 0.5-4.0 M urea and 1.0-3.0 M NaCl, two endothermic peaks appeared, corresponding to unbound (high temperature) and bound (low temperature) water in the gel networks, and eventually merged into one endothermic peak at 5.0-8.0 M urea and 4.0-4.5 M NaCl. After this merger, the endothermic peak shifted to 3.7, 4.0 and $5.6^{\circ}C$ at 5.0, 6.0 and 8.0 M urea, respectively. In the case of NaCl, a combination of peaks that occurred at 4.0-4.5 M were accompanied by a shift to lower temperature (-14.4 and $15.3^{\circ}C$) and the endothermic peak finally disappeared at 5.0 M NaCl due to the strong binding of water in the gel networks.

Zn2+ PVC-based Membrane Sensor Based on 3-[(2-Furylmethylene)amino]-2-thioxo-1,3-thiazolidin-4-one

  • Ganjali, Mohammad Reza;Zamani, Hassan Ali;Norouzi, Parviz;Adib, Mehdi;Rezapour, Morteza;Aceedy, Mohammad
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.4
    • /
    • pp.579-584
    • /
    • 2005
  • The 3-[(2-furylmethylene)amino]-2-thioxo-1,3-thiazolidin-4-one (FTT) was used as an excellent ionophore in construction of a $Zn^{2+}$ PVC-based membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 62% nitrobenzen (NB), 3% FTT and 5% sodium tetraphenyl borate (TBP). This membrane sensor shows very good selectivity and sensitivity towards $Zn^{2+}$ over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The membrane sensor revealed a great enhancement in selectivity coefficients for $Zn^{2+}$ ions, in comparison to the previously reported $Zn^{2+}$ membrane sensors. Theoretical studies also showed the selective interaction of TFF and $Zn^{2+}$ ions. The proposed membrane sensor exhibits a Nernstian behavior (with slope of 29.3 ${\pm}$ 0.3 mV per decade) over a wide concentration range (1.0 ${\times}$ $10^{-6}$-1.0 ${\times}$ $10^{-2}$) with a detection limit of 8.5 ${\times}$ $10^{-7}$ M (52 ng mL$^{-1}$). It shows relatively fast response time, in the whole concentration range ($\lt$ 20 s), and can be used for at least 10 weeks in a pH range of 3.0-7.0. The proposed membrane sensor was successfully used in direct determination of $Zn^{2+}$ ions in wastewater of industrial zinc electroplating companies, and also as an indicator electrode in titration with EDTA.

Beryllium(II) Recognition by Allosteric Effects in 1,2-Ethylenedioxybenzene Based Ditopic Receptors

  • Kim, Dong-Wan;Kim, Jung-Hwan;Hwang, Jae-Young;Choi, Myong-Yong;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2643-2647
    • /
    • 2011
  • Efficient ditopic receptor, uranyl(II) N,N'-(ethylenedioxy)benzenebis(salicylideneimine) (3) for beryllium ion has been obtained upon functionalization of 1,2-ethylenedioxybenzene (1) with a uranyl-salphen (salphen = N,N'-phenylenebis(salicylideneimine)) unit. Binding affinities of the receptor, 3 in AN-DMSO (v/v 95:5) solution have been measured for alkali and alkaline earth metal ions by conductometry comparing 1. The results showed that both monotopic 1 and ditopic receptor 3 were selective for $Be^{2+}$ ions over other cations, while especially 3 that can complex both with cations (coordinated to basic oxygen of ethylenedioxybenzene) and anions (coordinated to the Lewis acidic uranyl center) results in an increase of the stability constants by a factor of $10^{2.42}$ with respect to 1. Furthermore, the $Be^{2+}$-3 interactions are demonstrated by $^1H$ NMR experiments in highly polar solvent medium, DMSO-$d_6$. Higher selectivities were also observed for $Be^{2+}$ when the ditopic receptor, 3 was incorporated into PVC membranes and tested as ion selective electrodes at neutral pH.

Filled Skutterudites: from Single to Multiple Filling

  • Xi, Lili;Zhang, Wenqing;Chen, Lidong;Yang, Jihui
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.1
    • /
    • pp.54-60
    • /
    • 2010
  • This paper shortly reviews our recent work on filled skutterudites, which are considered to be one of the most promising thermoelectric (TE) materials due to their excellent power factors and relatively low thermal conductivities. The filled skutterudite system also provides a platform for studying void filling physics/chemistry in compounds with intrinsic lattice voids. By using ab initio calculations and thermodynamic analysis, our group has made progresses in understanding the filling fraction limit (FFL) for single fillers in $CoSb_3$, and ultra-high FFLs in a few alkali-metal-filled $CoSb_3$ have been predicted and then been confirmed experimentally. FFLs in multiple-element-filled $CoSb_3$ are also investigated and anonymous filling behavior is found in a few specific systems. The calculated and measured FFLs, in both single and multiple-filled $CoSb_3$ systems, show good accordance so far. The thermal transport properties can be understood qualitatively by a phonon resonance scattering model, and it seems that a scaling rule may exist between the lattice thermal resistivity and the resonance frequency of filler atoms in filled system. Even though a few things become clear now, there are still many unsolved issues that call for further work.

Analysis of Pressure Drop and Heat Loss in Liquid Sodium Circulation Wick of AMTEC (AMTEC의 소디움액체 순환윅에서 압력손실 및 열손실해석)

  • Lee, Ki-Woo;Lee, Wook-Hyun;Rhi, Seok-Ho;Lee, Kye-Bock
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.9
    • /
    • pp.953-960
    • /
    • 2012
  • An AMTEC (alkali metal thermal electric converter) is a device that is used for the direct conversion of heat to electricity. Sodium is used as the working fluid, and its circulation is driven by a capillary wick. The wicks used for circulation include an evaporator wick, artery wick, and condenser wick, and each wick has a pressure drop because of the circulation of liquid and vapor. For the circulation of sodium, the capillary pressure of the evaporator wick must be greater than the total pressure drop in the wicks. In this study, the pressure drop in the evaporator wick, artery wick, and condenser wick and the heat loss from the evaporator to the condenser through the artery wick were analyzed for the design of a 100 W AMTEC prototype. It was found that a particle diameter of 10 ${\mu}m$ is suitable for the evaporator wick to maintain a capillary pressure greater than total pressure drop in the circulation loop.

A Customized Cleaning Agent for the Maintenance of Electric Fume Collector Used for the Purification of Effluent Gas from the Textile Industry (섬유산업 배기가스 정화용 Electric Fume Collector 설비의 유지보수를 위한 맞춤형 세정제)

  • Kim, Hotae;Yoo, Hwang-Yooll;Jeon, Koung Min;Song, Doori;Kim, Jin-Bae
    • Applied Chemistry for Engineering
    • /
    • v.29 no.2
    • /
    • pp.229-236
    • /
    • 2018
  • A customized cleaning agent was investigated for improving the performance decreased by the pollution of collecting plates in an electric fume collector (EFC) which was developed and applied for the purification of effluent gas including oil mist from the textile industry. The pollutants on the surface of collecting plates were blackened by the condensation of oil mist for a long time and difficult to remove by general cleaning agents. The composition of an optimized cleaning agent consisted of alkali, alcohol, glycol and non-ionic surfactant sources was determined by considering the pollutant properties and effect on the damage of the basic metal of collecting plate and so on. The developed cleaning agent solution diluted by 9.1% was applied to the field test, and also the pollutants strongly adhered on collecting plate surfaces were successfully removed by a simple spraying method. The effluent gas purification efficiency of EFC increased significantly by cleaning of collecting plates.

Preparation of a New $K^{+}-ISFET$ Modified with 4'-Aminobenzo-15-crown-5 and Its Response Characteristics (4'-Aminobenzo-15-crown-5를 수식한 새로운 $K^{+}-ISFET$의 제조와 감응특성)

  • Lee, H.L.;Yun, J.H.;Yang, S.T.;Jung, D.S.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.85-92
    • /
    • 1992
  • A new potassium sensitive field effect transistor modified with 4'-aminobenzo-15-crown-5 was prepared and its response characteristics were evaluated. The response slope of $K^{+}-ISFET$ for pH was 30.0 mV/decade and the response time was mere than 3 minutes. And the response slope and time of the $K^{+}-ISFET$ for potassium ion as $19.5{\pm}0.2{\;}mV/decade$ and about 3 minutes, respectively. The linear response range of the sensor for potassium ion was $2.0{\times}10^{-4}{\sim}1.0{\times}10^{-2}M$. The selectivity coefficients of the $K^{+}-ISFET$ for the alkali and alkaline earth metal ions were also evaluated. Sodium, ammonium and calcium ions exhibited relatively significant interference. The long term stability of the sensor was remarkably improved and it could be used for more than 50 days.

  • PDF

Preparation and characterization of polymeric membrane pH Sensors (고분자막 pH 센서 제작 및 특성)

  • Cho, Dong-Hoe;Jeong, Seong-Suk;Chung, Koo-Chun;Lee, Kyung-Ho;Park, Myon-Yong;Kim, Byung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.35-40
    • /
    • 1996
  • The polymeric membrane pH sensor based on HDBA(hexyldibenzylamine) or HDPA(hexyldiphenylamine) as hydrogen ion carrier was prepared and electrochemical characterization for the variation of a temperature and membrane thickness were studied on. The sensor based on HDPA was not responded selectively to hydrogen ion. The sensor based on HDBA was responded linearly to hydrogen ion in the range of pH 2 - pH 10, it showed the fast response time of 30 - 50sec. and Nernstian slope of 53.6mV/pH. The interfering effect on alkali and alkaline earth metal ions of pH sensor were lower than glass pH sensor. There was shown a good reproducibility and stability with the precision of 2 - 4mV (${\pm}0.1mV$).

  • PDF

Lead Ion Selective Solid Contact Electrode based on Tetramethylthiuram monosulfide ionophore (Tetramethylthiuram monosulfide를 ionophore로 이용한 납 이온 선택성 poly(aniline) 고체 접촉 전극)

  • Han, Won-Sik;Park, Woon-Suk;Kwon, Hye-Yeong;Lee, Young-Hoon;Hong, Tae-Kee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.356-361
    • /
    • 2013
  • Lead (II) ion selective poly(aniline) solid contact electrode based on Tetramethylthiuram monosulfide ionophore as a sulfur containing sensing material is successfully developed. The electrode exhibits good linear response of 25.6 mV / decade (at $20{\pm}0.2^{\circ}C$, r2=0.995) within the concentration range of $1.0{\times}10^{-1}{\sim}4.0{\times}10^{-7}$ M Pb (II). The composition of this electrode was Ionophore : PVC : dioctylphthalate : potassiumtetrakis(4-chlorophenyl)borate : Oleic acid = 5.0 : 20.0 : 25.0 : 4.0 : 5.0. When we consider the results of using different composition electrodes based on only one potassiumtetrakis(4-chlorophenyl)borate or Oleic acid liphophlic additive, poly(aniline) solid contact electrode based on Tetramethylthiuram monosulfide ionophore with potassiumtetrakis(4-chlorophenyl)borate and Oleic acid liphophlic additive had the best result in response characteristics. The electrode shows good selectivity for lead (II) ion in comparison with alkali, alkaline earth, transition and heavy metal ions. This electrode is suitable for use with aqueous solutions of pH 3.0 ~ 7.0 and their standard deviation in the measured emf differences was ${\pm}2.94$ mV at Tris buffered lead sample solution of $1.0{\times}10^{-2}$ M and ${\pm}2.82$ mV at Tris buffered lead sample solution of $1.0{\times}10^{-3}$ M. Their stabilization time was less than 710 s. and response time was less than 16 s.

Experimental Evaluation on Occurrence Possibility of Pollutants from Aggregates (순환골재의 오염물질 발생 가능성에 관한 실험적 평가)

  • Park, Jeong-Ho;Seong, Jin-Uk;Park, Je-Chul
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • This study was on leaching test(KSLT, TCLP) of the aggregate for the products(RA-1) and for the site(RA-2) to evaluate the characteristics of contaminants and the possibility of contamination arising from the aggregate. On the basis pH, conductivity and heavy metal contents in the aggregate, RA-1 indicated higher than RA-2. As a result of the leaching test, the pollutants were eluted from the aggregate increased as the particle size of the aggregate was smaller. The pH in the aggregate had a strong alkali by a pH value of 9.0~12.3, the conductivity was higher in less than 10mm RA-1 due to the leaching of dissolved inorganic ions. The heavy metals satisfied the leaching standards of KSLT and less 10% was eluted from the aggregate. As a result of evaluating water pollution possibility of the aggregate, the pH displayed in items with a very high possibility of contamination, conductivity and turbidity did in item with a low possibility of contamination and on the other hand the heavy metals did in item with a very low possibility of contamination.