• 제목/요약/키워드: Alkali and alkaline earth metal

검색결과 76건 처리시간 0.025초

Study on Solvent Extraction Using Salen(NEt2)2 as a Chelating Agent for Determination of Trace Cu(II), Mn(II), and Zn(II) in Water Samples

  • In, Gyo;Kim, Young-Sang;Choi, Jong-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권5호
    • /
    • pp.969-973
    • /
    • 2008
  • Solvent extraction using a Schiff-base, salen$(NEt_2)_2$, as a chelating agent has been conducted on several water samples to study the determination of trace Cu(II), Mn(II) and Zn(II). Experimental conditions for the formation and extraction of metal complexes were optimized with an aqueous solution similar in composition to the samples. The matrix difference between the sample and standard solutions was approximately matched, and the pH of each sample solution was adjusted to 9.5 with $NaHCO_3/NaOH$ buffer. The concentration of salen$(NEt_2)_2$ was $7.3\;{\times}\;10^{-3}$ mol/L, and the complexes were extracted into MIBK solvent followed by the measurement of AAS absorbance. The potential interference of concomitant ions was investigated, but no interference from alkaline and alkali earth ions was shown in this procedure. The given procedure is precise, as judged from the relative standard deviation of less than 5% for five measured data. The recovery of 93-103% shows that this method is quantitative for such trace metal analysis.

Ammonium Ion Binding Property of Naphtho-Crown Ethers Containing Thiazole as Sub-Cyclic Unit

  • Kim, Hong-Seok;Do, Kyung-Soon;Kim, Ki-Soo;Shim, Jun-Ho;Cha, Geun-Sig;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권10호
    • /
    • pp.1465-1470
    • /
    • 2004
  • A short and efficient synthesis, solvent extraction and potentiometric measurements of new thiazole-containing naphtho-crown ethers are reported. The naphthalene moiety enhances the ammonium ion selectivity over potassium ion. The selectivity of ${NH_4}^+/K^+$ follows the trend $3\;{\approx}\;2\;>\;1$, indicating that the differences in conformational changes of 2 and 3 in forming ammonium complexes affect little on the resulting ammonium/potassium extraction selectivity ratio. The ammonium ion-selective electrodes were prepared with noctylphenyl ether plasticized poly(vinyl chloride) membranes containing 1-4 the effect of one naphthalene unit introduced on either right (2) or left (3) side of thiazolo-crown ether on their potentiometric properties (e.g., ammonium ion selectivity over other cations, response slopes, and detection limits) were not apparent. However, the ammonium ion selectivity of 1, 2 and 3 over other alkali metal and alkaline earth metal cations is 10-100 times higher than that of nonactin.

탈알루미늄 및 알칼리/알칼리토금속 양이온을 교환한 Y형 제올라이트의 NO흡착 특성 (Adsorption Characteristics of Nitrogen monoxide over Dealuminated and Alkali/Alkaline-earth Metal ion Exchanged Y-Zeolites)

  • 김철현;이창섭
    • 한국가스학회지
    • /
    • 제9권4호
    • /
    • pp.17-25
    • /
    • 2005
  • 탈알루미늄 및 알칼리/알칼리토금속 양이온을 교환한 Y형 제올라이트 촉매를 제조하였다. 제조한 촉매물질의 원소조성 및 구조 변화를 ICP-AES, XRF 및 XRD와 같은 각종 분광학적 방법으로 분석하였으며, NO-TPD 실험을 통한 표면흡착종의 탈착 거동을 조사하였다. 탈알루미늄 처리 후 출발물질인 NaY보다 촉매물질의 Si/Al비는 증가하였으며, 탈알루미늄 후 Cs및 Ba양이온으로 교환한 Y형 제올라이트의 경우 Si/Al비가 부가적으로 조금 더 감소하였다. 탈알루미늄 처리한 촉매는 Al원자의 탈리로 기본골격의 파괴가 심화되어 framework (tetrahedral)구조가 감소하고 non-framework (octahedral) 구조가 증가하였다. 이러한 현상은 스팀처리시간이 많아질수록 증가하였으며 양이온을 교환한 후에는 더 크게 나타났다. NO-TPD 실험에서 탈알루미늄 및 양이온 교환 후 촉매의 활성점을 나타내는 탈착 봉우리들은 저온으로 이동하였으며, 스팀처리시간이 많아질수록 탈착 봉우리가 상대적으로 저온에서 나타났다. 탈알루미늄 및 양이온 교환을 한 Y형 제올라이트는 교환된 양이온과 탈알루미늄으로 인한 non-framework (octahedral) 구조의 생성이 촉매의 활성에 미치는 영향이 더 큰 것으로 나타났다.

  • PDF

Development of a New Copper(II) Ion-selective Poly(vinyl chloride) Membrane Electrode Based on 2-Mercaptobenzoxazole

  • Akhond, Morteza;Ghaedi, Mehrorang;Tashkhourian, Javad
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권6호
    • /
    • pp.882-886
    • /
    • 2005
  • Copper(II) ion-selective PVC membrane electrode based on 2-mercaptobenzoxazole as a new ionophore and o-nitrophenyl octyl ether (o-NPOE) as plasticizer is proposed. This electrode revealed good selectivity for $Cu^{2+}$ over a wide variety of other metal ions. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, and concentration of internal solution on the potential response of $Cu^{2+}$ sensor were investigated. The electrode exhibits good response for $Cu^{2+}$ in a wide linear range of 5.0 ${\times}$ 10−.6-1.6 ${\times}$ $10^{-2}$ mol/L with a slope of 29.2 ${\pm}$ 2.0 mV/decade. The response time of the sensor is less than 10 s, and the detection limit is 2.0 ${\times}$ $10^{-6}$ mol/L. The electrode response was stable in pH range of 4-6. The lifetime of the electrode was about 2 months. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, and transition metal ions.

거대고리 중성 운반체를 갖는 Hg(II)이온 선택성 전극 (Hg(II) ion- Selective Electrodes with Neutral Carriers of Macrocycles)

  • 정오진
    • 한국환경과학회지
    • /
    • 제5권2호
    • /
    • pp.211-220
    • /
    • 1996
  • 두 개의 황과 셀렌의 주개원자를 포함한 새로운 thia 및 diselena 크라운에데르 화합물을 합성하였다. 그리고 이 화합들을 중성운반체로 하고 PVC-가소제 (STPB)를 포함한 Hg(ll) 선택성 전극을 제작하였다. 이 전극들을 이용하여 여러 이온들의 전기화학적 선택성, 중성운반체의 종류 및 농도와 선택막의 매질에 대한 효과 그리고 실험용액의 pH변화에 대한 전극의 선택적 감응성들의 영향을 각각 검토하였다. 1,10-diselena-18-crown-6-PVC-STPB의 중성운반체의 막전극은 $10^{-2}$-10- M $Hg^{2+}$ 이온의 농도범위에서 ${28.2}\pm{0.6}$의 Nernstian 기울기를 갖는 좋은 선형적 감응성을 갖는다. 그리고 이 전극은 pH 2.5~6.0 범 위에서 알칼리토 금속, 몇가지 중금속 및 희토류 금속 이온에 대하여 좋은 선택성을 갖는다. 특히 이 전극은 수용액 중에서.$1^-$ 이온으로 Hg^{2-}$ 이온을 전위차 적정할 수 있는 센서로서 응용할 수 있다.

  • PDF

Analysis of Chemical Compounds of Gaseous and Particulate Pollutants from the Open Burning of Agricultural HDPE Film Waste

  • Kim, Tae-Han;Choi, Boo-Hun;Kook, Joongjin
    • 인간식물환경학회지
    • /
    • 제24권6호
    • /
    • pp.585-593
    • /
    • 2021
  • Background and objective: Illegal open-air incineration, which is criticized as a leading source of air pollutants among agricultural activities, currently requires constant effort and attention. Countries around the world have been undertaking studies on the emission of heavy metal substances in fine dust discharged during the incineration process. A precise analytical method is required to examine the harmful effects of particulate pollutants on the human body. Methods: In order to simulate open-air incineration, the infrastructure needed for incineration tests complying with the United States Environmental Protection Agency (EPA) Method 5G was built, and a large-area analysis was conducted on particulate pollutants through automated scanning electron microscopy (SEM)-energy-dispersive X-ray spectroscopy (EDS). For the test specimen, high-density polyethylene (HDPE) waste collected by the DangJin Office located in Choongcheongnam-do was used. To increase the identifiability of the analyzed particles, the incineration experiment was conducted in an incinerator three times after dividing the film waste into 200 g specimens. Results: Among the metal particulate matters detected in the HDPE waste incineration test, transition metals included C (20.8-37.1 wt%) and O (33.7-37.9 wt%). As for other chemical matters, the analysis showed that metal particulate matters such as metalloids, alkali metals, alkaline earth metals, and transition metals reacted to C and C-O. Si, a representative metalloid, was detected at 14.8-20.8 wt%, showing the highest weight ratio except for C and O. Conclusion: In this study, the detection of metal chemicals in incinerated particulate matters was effectively confirmed through SEM-EDS. The results of this study verified that HDPE waste adsorbs metal chemicals originating from soil due to its own properties and deterioration, and that when incinerated, it emits particulate matters containing transition metals and other metals that contribute to the excessive production and reduction of reactive oxygen species.

Synthesis and Binding Properties of 1,3,5-Tris(2-arylthiomethyl)mesitylene: A Selective Ag (I) Ionophore

  • Kim, Hong-Seok;Bae, Seon-Yun;Kim, Ki-Soo;Choi, Jun-Hyeak;Choi, Heung-Jin;Shim, Jun-Ho;Cha, Geun-Sig;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권2호
    • /
    • pp.417-421
    • /
    • 2008
  • The efficient synthesis of four mesitylene-based receptors 1-4 and their potentiometric response characteristics to alkali metal, alkaline earth metal, and transition metal ions, under various pH conditions are outlined. Receptor 1-based electrode exhibited more sensitive response to Ag+ ion (49 mV/decade of range from 10-6 to 10-2 M) than the 2-based electrode (47 mV/decade of range from 3 ´ 10-5 to 10-2 M), while the 3- and 4-based ones revealed sub-Nernstian below 40 mV/pAg+. All electrodes showed substantial responses to Ag+ ion under acidic condition, but there was almost nil-response to other transition metal ions (Fe2+, Co2+, Zn2+, Ni2+, Pb2+, Cd2+, Cu2+ and Hg2+). The association constant of receptor 1 toward Ag+ ion, measured by 1H NMR titration, showed the largest value (200 M-1) among the tested receptors. The results were interpreted with semi empirically-modeled structures.

The Potentiometric Performance of Mercury (II) Ion-Selective Electrode Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Rhee Paeng, In-Sook
    • 전기화학회지
    • /
    • 제11권1호
    • /
    • pp.59-63
    • /
    • 2008
  • Poly (vinylchloride) (PVC) membrane electrodes based on neutral carrier, tetracycline was prepared as an active sensor for Hg(II) ion, and tested in different contents of the potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as lipophilic salt. Bis (2-ethylhexyl) sebacate (DOS), bis(l-butylpentyl) adipate (BBPA), 2-nitrophenyl octyl ether (NPOE) and dibutyl phthalate (DBP) were used as diverse plasticizing solvent mediators. This electrode shows excellent potentiometric response characteristics and display good linearity with log $[Hg^{+2}]$ versus EMF response, over a range of concentrations between $10^{-7}$ and $10^{-3}M$. With 30.8mV/decade Nernstian slope, the detection limit was $6.9{\times}10^{-9}M$ and the response time was less than 20s. The proposed electrode yields very good selectivity for mercury (II) ion over many cations such as alkali, alkaline earth, transition and heavy metal ions. And it shows a very stable potential values in a wide pH range. This reliable electrode prepared was kept at least a month without considerable alteration in their response to Hg (II) ion.

A Novel Iron(III) Selective Membrane Electrode Containing a Tripodal Polycatacholamine as Sensor

  • Bera, Rati Kanta;Sahoo, Suban K;Baral, Minati;Kanungo, B.K.
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권10호
    • /
    • pp.3592-3596
    • /
    • 2011
  • A novel poly(vinylchloride)-based membrane sensor using $N^1$,$N^3$,$N^5$-tris(2-(2,3-dihydroxybenzylamino)-ethyl)cyclohexane-1,3,5-tricarboxamide (CYCOENCAT, L) as ionophore has been prepared and explored as $Fe^{3+}$ selective electrode. The membrane electrode composed of ionophore, poly(vinylchloride) and o-nitropheyloctyl ether in the optimum ratio 4:33:63 gave excellent potentiometric response characteristics, and displayed a linear log[$Fe^{3+}$] versus EMF response over a wide concentration range of $1.0{\times}10^{-5}-1.0{\times}10^{-1}$ M with super nernstian slope of 28.0 mV/decade and the detection limit of $8.0{\times}10^{-6}$ M. The proposed ion selective electrode showed fast response time (< 15 s), wide pH range (3.0-7.0), high non-aqueous tolerance (up to 20%) and adequate long life time (120 days). It also exhibited very good selectivity for $Fe^{3+}$ relative to a wide variety of alkali, alkaline earth, transition and heavy metal ions. Further, the analytical applicability of the sensor was tested as an indicator electrode in the potentiometric titration of $Fe^{3+}$ with EDTA.

Synthesis of a New Hexadendates Schiff's Base and Its Application in the Fabrication of a Highly Selective Mercury(II) Sensor

  • Ganjali, M.R.;Norouzi, P.;Alizadeh, T.;Salavati-Niasari, M.
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권1호
    • /
    • pp.68-72
    • /
    • 2007
  • A new PVC membrane potentiometric sensor that is highly selective to Hg2+ ions was prepared, using bis(2-hydroxybenzophenone) butane-2,3-dihydrazone (HBBD) as an excellent hexadendates neutral carrier. The sensor works satisfactorily in the concentration range of 1.0 × 10-6 to 1.0 × 10-1 mol L-1 (detection limit 4 × 10-7 mol L-1) with a Nernstian slope of 29.7 mV per decade. This electrode showed a fast response time (~8 s) and was used for at least 12 weeks without any divergence. The sensor exhibits good Hg2+ selectivity for a broad range of common alkali, alkaline earth, transition and heavy metal ions (lithium, sodium, potassium, magnesium, calcium, copper, nickel, cobalt, zinc, cadmium, lead and lanthanum). The electrode response is pH independent in the range of 1.5-4.0. Furthermore, the developed sensor was successfully used as an indicator electrode in the potentiometric titration of mercury ions with potassium iodide and the direct determination of mercury in some binary and ternary mixtures.