• Title/Summary/Keyword: Aligner

Search Result 83, Processing Time 0.025 seconds

Achievement of Anterior Teeth Arrangement Using a Single Stage of Clear Aligner

  • Ryu, Seon-Jeong;Choi, Sung-Hwan;Cha, Jung-Yul;Hwang, Chung-Ju
    • Journal of Korean Dental Science
    • /
    • v.14 no.2
    • /
    • pp.90-100
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the degree of achievement of anterior tooth movement using a thermoplastic clear aligner by superimposing pretreatment, setup, and post-treatment models and to analyze the factors that influence it. Materials and Methods: Forty patients who underwent clear aligner treatment at the Department of Orthodontics were included in the study. The pretreatment, setup, and post-treatment models were superimposed, and the achievement rates were evaluated. We analyzed the factors that caused changes in achievement rate on each condition. Result: The average achievement rate of total tooth movement was 57.65%. Mesiodistal and anteroposterior displacements were achieved better than vertical displacement and rotation. In each displacement, posterior, mesial, and extrusive movements were better achieved than the rotation. Spacing was better corrected than crowding, especially in the mesiodistal direction. Most of the tooth movements were achieved better when using 3-step thicknesses of aligners were used. Conclusion: The treatment results of clear aligners may differ depending on the type of tooth movement, age and other treatment conditions. Clinicians should consider unfavorable conditions based on the results of this study.

Clinical expression of programmed maxillary buccal expansion and buccolingual crown inclination with Invisalign EX30 and SmartTrack aligners and the effect of 1-week vs. 2-week aligner change regimes: A retrospective cohort study

  • Joseph O'Connor;Tony Weir;Elissa Freer;Brett Kerr
    • The korean journal of orthodontics
    • /
    • v.54 no.3
    • /
    • pp.142-152
    • /
    • 2024
  • Objective: This retrospective cohort study aimed to assess and compare the accuracy of 3 different Invisalign® treatment regimens in terms of variations of aligner change frequency and type of aligner material in achieving maxillary dental buccal expansion. Methods: Altogether, 120 adult patients whose treatment involved maxillary dental expansion with Invisalign® were included. The patients were divided into 3 groups, with each group comprising 40 patients as follows: SmartTrack® 1-week changes (ST1), SmartTrack® 2-week changes (ST2), and EX30® 2-week changes (EX2). The groups were assessed by comparing actual changes achieved with those prescribed by ClinCheck®. The rates of clinically significant inaccuracies (CSI) observed for buccal expansion (≥ 0.5 mm) and buccolingual inclination (≥ 2°) during expansion were then determined. Results: In terms of expansion, the ST1 group demonstrated the highest CSI rate at all tooth levels, whereas the ST2 group had the lowest rate of CSI and the lowest mean inaccuracy for each tooth level. In terms of buccolingual inclination, the ST1 group had the highest CSI rate across all tooth levels, whereas the EX2 group had the lowest CSI rate at all tooth levels except for the canine level where the ST2 group had the lowest CSI rate. A tendency toward overexpression of buccal crown inclination, and underexpression of buccal expansion was observed at all tooth levels. Conclusions: Two-week aligner change regimens offer improved accuracy compared with 1-week aligner changes. SmartTrack® 2-week changes were the most accurate for buccal expansion, whereas EX30® 2-week changes were the most accurate for buccolingual inclination.

Intraoral ageing of aligners and attachments: Adverse effects on clinical efficiency and release of biologically-active compounds

  • Theodore Eliades;George Eliades
    • The korean journal of orthodontics
    • /
    • v.54 no.4
    • /
    • pp.199-209
    • /
    • 2024
  • The clinical application of aligners is accompanied by the ageing of the polymer appliances and the attachments used, which may result in inefficiency in reaching the predicted range of tooth movement, and release of compounds and microplastics in the oral cavity as a result of the friction, wear and attrition of the aligner and composite attachment. The purpose of this review is to present the mechanism and effects of in vivo ageing; describe the hydrolytic degradation of aligners and enzymatic degradation of composite attachments; examine the ageing pattern of aligners in vivo, under actual clinical scenarios; and identify a link to the discrepancy between predicted and actual clinical outcome. Lastly, strategies to deal with three potentially critical issues associated with the use of aligners, namely the necessity of weekly renewal, the dissimilar mechanical properties of aligner and attachment resulting in wear and plastic deformation of the aligner, and the development of integuments and biofilms with microbial colonization of the appliance, are discussed.

THE USE OF REMOVABLE APPLIANCE FOR THE CORRECTION OF MINOR IRREGULARITIES IN ANTERIOR SEGMENT (전치부의 경미한 공간부조화 개선을 위한 가철성 장치의 적용 예)

  • Kwak, Ah-Ram;Choi, Yeong-Chul;Park, Jae-Hong;Choi, Seong-Chul;Kim, Gwang-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.685-693
    • /
    • 2007
  • Class I malocclusion without skeletal problem results from tooth size/arch-size discrepancies, either evidenced by crowding, or spacing problems. Treatment method can be chosen according to dentition, the amount of arch discrepancy, patient compliance, or patient demands. We report of clear aligner and spring aligner that can be applicated in cases of permanent dentition with minimal arch discrepancy in anterior segment. There are some limits of application, but these are very useful appliances in the selective case. When crowding exists, definitive analysis and diagnosis should be made before starting treatment because certain amount of space must be obtained somewhere in the dentition to resolve the crowding. Therefore, appliance should be applied when lacking space is small. Also, in cases with spacing arch circumference is reduced after alignment so no problem in intermaxilla occlusal relationship must be confirmed. In case with crowding, judicious removal of interproximal enamel is indicated.

  • PDF

Design and development of clear aligner management system using QR code (QR 코드를 활용한 투명 교정장치 관리 시스템 설계 및 개발)

  • Jang, Jin-Su;Son, Ho-Jung;Sim, Ji-Young;Kang, Sin-Yeong;Moon, Jun-Mo;Lee, Tae-Ro
    • Journal of Digital Convergence
    • /
    • v.17 no.9
    • /
    • pp.185-192
    • /
    • 2019
  • The introduction of smart technology provides accuracy, safety, and efficiency to both physicians and patients. Although interest in a clear aligner is increasing among users worldwide, the current clear aligner requires a visit to the hospital every one or two weeks for replacement, which is a very cumbersome process. There is also confusion among dentists and patients because about 40 to 80 devices are made, and calibration is done based on the order and duration of the clear aligner. Therefore, this study designed and developed a clear aligner management system so that communication between the patient and dentist can be smoothly performed by inserting the QR code into the transparent correction device. As a result, the size of the QR code was recognized as $6{\ast}6mm^2$ which can be used in the oral and the recognition distance was 100% within 12 cm. Since the dentist can remotely manage the patient with the proposed system and improve the correction effect, it is possible to manage patients abroad, as well as domestically.

The development of automatic optical aligner with using the image processing (Image Processing을 이용한 자동 광 정렬 장치 개발)

  • Um, Chul;Kim, Byung-Hee;Kim, Sung-Geun;Choi, Young-Seok
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.536-539
    • /
    • 2002
  • In this paper, we developed the automatic optical fiber aligner by image processing and automatic loading system. Optical fiber is indispensable for optical communication systems that transmit large volumes of data at high speed, but super-precision technology in sub-micron units is required for optical axis adjustment, we have developed 6-axis micro stage system for I/O optical fiber arrays, the initial automatic aligning system/software for a input optical array by the image processing technique, fast I/O-synchronous aligning strategy, the automatic loading/unloading system and the automatic UV bonding mechanism. In order to adjust the alignment it used on PC based motion controller, a $10\mu\textrm{mm}$ repeat-detailed drawing of automatic loading system is developed by a primary line up for high detailed drawing. Also, at this researches used the image processing system and algorithm instead of the existing a primary hand-line up. and fiber input array and waveguide chip formed in line by automatic. Therefore, the developed and manufactured optical aligning system in this research fulfills the great role of support industry for major electronics manufacturers, telecommunications companies, universities, government agencies and other research institutions.

  • PDF

Clear Aligner Therapy: Evidence, Eloquence and Reality

  • Nikhilesh R. Vaid;Samar M. Adel
    • Journal of Korean Dental Science
    • /
    • v.16 no.2
    • /
    • pp.115-127
    • /
    • 2023
  • The demand for orthodontic clear aligner therapy (CAT) has increased significantly over the last decade, offering advantages over the fixed appliances (FA) including enhanced aesthetics, better hygiene and comfort, along with minimal restrictions on the patient's diet. Moreover, a marked improvement in the efficacy of tooth movement using aligners has been documented. On the contrary, there have been known limitations of CAT including the compliances issues and the apparent lack of efficacy for certain types of tooth movement such as closure of extraction space compared to FA. Thus, evidence-based evaluation of the accuracy of prediction of tooth movement with clear aligners and their ability to effectively perform major tooth and root movements compared to FA are crucial. Although several systematic reviews have investigated various aspects of the effectiveness of CAT, we are yet to obtain a rather conclusive answer to this question. The current review attempted to summarize the evidence-based findings of most systematic reviews about CAT available to date. Major issues regarding the predictability of tooth movement, the role of attachments and auxiliaries in improving the effectiveness of CAT, and the treatment outcomes in comparison to FA were investigated. Clinical recommendation have been also elaborated based on the interpretation of the findings of all systematic reviews included in this study.

The Validity of Head Posture Aligner in Posteroanterior Cephalometry (정모 두부 방사선 사진 촬영시 Head Posture Aligner의 유용성에 관한 연구)

  • Kim, Eun-Hee;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.543-552
    • /
    • 2000
  • The purposes of this study were to evaluate the reproducibility of posteroanterior(PA) cephalograms obtained by two methods, the Head Posture Aligner(HPA) method in natural head posture and the conventional method(operator-guided method), and to compare the vertical rotational differences of the head Posture between lateral and PA cephalograms according to the method. The sample was consisted of 30 adults. At first day, a PA cephalogram and a lateral cephalogram were obtained from each subject by two methods to investigate the difference of vertical rotational posture between lateral and PA cephalograms. Two weeks later, another PA cephalogram was obtained using each method to evaluate the reproducibility of head posture. Five height measurements and nine width measurements were used in the paired t-test to compare the reproducibility of the PA cephalometric measurements between two methods. The differences of vertical rotational posture between lateral and PA cephalograms were calculated from a computer program and compared according to the method used, and following results were obtained. 1. Height measurements obtained by operator-guided method showed significant differences according to the time interval and revealed low reproducibility. 2. Height measurements obtained by HPA method did not show significant differences according to the time interval and presented high reproducibility. 3. In the comparison of width measurement, two methods did not show distinct differences in reproducibility. 4. The difference of vertical rotational posture between lateral and PA cephalograms showed $0.8^{\circ}$ in the HPA method, more less than $2.5^{\circ}$ in the operator-guided method. The results of the present study suggest that the HPA may be helpful in the PA cephalometric radiography in terms of reproducibility.

  • PDF

Implant surgery and prosthodontic treatment of Temporomandibular disorder patient combined SERAFIN clear aligner system : Clinical case report (세라핀 투명교정 시스템을 활용한 교합 장애 및 치아 결손 증례의 치료)

  • Won-Gun, Chang
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • Adult patients who need implant and prosthodontic treatment often need treatment to improve the existing occlusion through orthodontic treatment for long-term stable treatment results. However, due to non-aesthetic and uncomfortable orthodontic treatment with orthodontic brackets and wires, many adult patients give up treatment even though they know the need for it. Recently, as digital dentistry has affected all areas of dentistry, clear aligner orthodontic systems have begun to be widely used, and their use is increasing in adults and old-aged people due to the esthetic advantage and convenient oral care. SERAFIN clear aligner system developed in Korea has been developed with the aim of implementing a functional occlusion harmony and is used not only for partial orthodontic treatment but also comprehensive orthodontic treatment. This patient presentation is shown the treatment using SERAFIN clear aligner system for the treatment of patient with TMD, severe extrusion of maxillary second molars, and extracted teeth.