• Title/Summary/Keyword: Al tube

Search Result 347, Processing Time 0.032 seconds

A Study of Analytical Method for Ethylene and Low Weight Hydrocarbons (LWHC) using Thermal Desorption and Gas Chromatography-Flame Ionization Detector with (TD-GC-FID) (저온열탈착기술을 이용한 에틸렌 및 저분자 탄화수소 분석방법 연구)

  • Kim, Bo-Won;Kim, Ki-Hyun;Kim, Yong-Hyun;Ahn, Jeong-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.1
    • /
    • pp.77-87
    • /
    • 2014
  • In this study, an experimental approach to measure a suite of low weight hydrocarbons was investigated with an emphasis on ethylene (EL) along with many others (ethane (EA), propane (PA), propylene (PL), n-butane (BA), acetylene (AL), methyl acetylene (ML)). Their concentrations were quantified using GC-FID system equipped with thermal desorption (TD) system. The TD-based analysis was conducted using both Link Tube/Thermal Desorber (LT/TD) method and Modified Injection through a Thermal Desorption (MITD) method. The results of these analyses were evaluated in a number of respects. The system allowed the detection of all compounds except methane with the mean response factor (RF) of 10.28 (EA) to 11.94 (PL). The method detection limits of target compounds were seen in the range of 0.027 (ML) to 0.146 ng (BA). The emission flux of some environmental samples (fruits), when measured using a small flux chamber system, fell in the range of 0.14 (AL: Kiwi) to $181ng{\cdot}g^{-1}{\cdot}hr^{-1}$ (EL: Apple Peel). The results of this study confirm that the experimental approach developed in this study allows to accurately measure emissions of low weight hydrocarbons (LWHC) like ethylene from various natural and man-made source processes.

Manufacturing Functional Nano-Composites by Using Field-Aided Micro-Tailoring Manipulation (Field-Aided Micro-Tailoring에 의한 기능성 나노복합재 제조)

  • Cho, Hee-Keun;Rhee, Juhun;Sim, Eun-Sup
    • Composites Research
    • /
    • v.25 no.6
    • /
    • pp.178-185
    • /
    • 2012
  • One of a unique technique in manipulating a multifunctional composite is demonstrated in this study. An electric field is applied to a liquid suspension in order to align the inclusions along with the direction electric field. This is called FAiMTa(Field Aided Micro Tailoring). It makes orthotropic polymer composites by arranging the micro and/or nano size particle inclusions in chain-line formation. Several kinds of particles such as $Al_2O_3$, graphite, CNT(Carbon Nano Tube), W(Tungsten) are tested to verify the effectiveness of the FAiMTa. The particles redistributed in an epoxy suspension and their coupons show that mechanical and thermal properties of orthotropic and random composites containing those particles depend on the trend of particles' alignment. The micro-images of the functional composite from FAiMTa have been captures and their physical properties demonstrate their wide-range and state-of-the-art application for advanced multifunctional composites.

Cooling Heat Transfer Characteristics of CO2 in Helical Coil Type Gas Coolers (헬리컬 코일형 가스냉각기 내 CO2의 냉각 열전달 특성)

  • Son, Chang-Hyo;Jeon, Min-Ju;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.699-706
    • /
    • 2007
  • The cooling heat transfer coefficient and pressure drop of $CO_2$(R-744) in helical coil copper tubes were investigated experimentally The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter. a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55mm inner diameter The refrigerant mass fluxes were varied from 200 to $600 [kg/m^2s]$ and the inlet pressures of 9as cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively food agreement with those Predicted by Ito's correlation developed for single-phase in helical coil tubes. Though a few correlation available with the data. the local heat transfer coefficient of $CO_2$ agrees well with those presented by Pitla et al. among the predictions. However at the region near pseudo-critical temperature. the experiment data indicate higher values than the Pitla et al. correlation.

Development of a Digital Soil Tensiometer using Porous Ceramic Cups (다공 세라믹 컵을 이용한 디지털 토양수분 장력계 개발)

  • Jung, In-Kyu;Chang, Young-Chang;Kim, Ki-Bok;Kim, Yong-Il;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.448-454
    • /
    • 2007
  • This study was conducted to develop a 100 kPa soil tensiometer mainly consisted of a porous ceramic cup, water-holding tube, and a digital vacuum gauge, through theoretical design analysis and experimental performance evaluation. Major findings were as follows. 1. Theoretical analysis showed that air entry value of a porous media decreased as the maximum effective size of the pore increased, and the maximum diameter of the pores was $2.9\;{\mu}m$ for measuring up a 100 kPa of soil-water tension. 2. Property analysis of tensiometer porous cups supplied in Korean domestic market indicated that main components were $SiO_2$ and $Al_2O_3$ with a porosity range of $33.8{\sim}49.3%$. 3. The porous cup selected through sample fabrication and air-permeability tests showed weight ratios of 87% and 11% for $Al_2O_3$ and $SiO_2$. The analysis of SEM (scanning electron microscope) images showed that the sample was sintered at temperatures of about $1150^{\circ}C$, which consisted of pores with sizes of up to 25% of those for commercial porous cups. 4. The prototype soil tensiometer was fabricated using the developed porous cup and a digital vacuum gauge that could measure water tension with a pressure of 85 kPa in air tests. 5. In-soil tests of the prototype conducted during a period of 25-day drying showed that soil-water tension values measured with the prototype and commercial units were not significantly different, and soil-water characteristic curves could be established for different soils, confirming accuracy and stability of the prototype.

Measurement of Apron Shielding Rate for X-ray and Gamma-ray (X선 및 감마선에 대한 apron의 차폐율 측정)

  • Park, Myeong-Hwan;Kwon, Deok-Moon
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.245-250
    • /
    • 2007
  • This research measured the shielding rates of apron 0.25 and 0.5 mmPb for X-ray energy in diagnosis radiation system and gamma-ray energy of $^{99m}Tc$-MDP and $^{18}F$-FDG. X-ray energies were measured on effective energy of $26.2{\sim}45.6\;keV$ when additional filtering plate of 0, 2 mmAl is used within the range of tube voltage $40{\sim}120\;kVp$, and at this time, apron 0.5 mmPb has shown about 5.5% of increase in its shielding rate over 0.25 mmPb at the highest quality. Besides, the aprons of the two types have shown high shielding rate of over 90% for direct X-ray and spatial dose rate. And, in case 0.25 and 0.5 mmPb aprons were used at 140keV of $^{99m}Tc$-MDP, the shielding effects were between 30 and 53%, and at high energy of 511 keV, $^{18}F$-FDG, the shielding effects of apron, $1.3{\sim}3.6%$, were very small.

  • PDF

Gas Permeation and Steam Stability of Ga Salt Doped Silica Membrane by Chemical Vapor Deposition (CVD 법으로 제조한 실리카 막의 Ga 염 첨가에 따른 스팀안정성 및 기체투과특성)

  • Ryu, Seung Hee;Lee, Yong Taek
    • Membrane Journal
    • /
    • v.22 no.6
    • /
    • pp.424-434
    • /
    • 2012
  • In this study, a ceramic membrane was prepared by CVD. Tube type alpha alumina support was used for substrate and added the Ga salt in intermediate layer. Synthesized method was counter diffusion CVD method at $650^{\circ}C$ with tetramethylorthosilane (TMOS). Gas permeation was measured at $600^{\circ}C$ using single-component $H_2$, $N_2$, $CO_2$ and $CH_4$. During the steam treatment, $H_2/N_2$ permselectivity of non-Ga silica membrane was decreased 926 to 829 at $600^{\circ}C$. On the other hand $H_2/N_2$ permselectivity of added Ga silica membrane was stable 910 to 904 at $600^{\circ}C$. These results show that the metal-doped membranes improved steam stability for gas separation.

Fabrication and Characterization of a Fiber-optic Radiation Sensor for Detection of Tritium (삼중수소 검출용 광섬유 방사선 센서의 제작 및 특성분석)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Lee, Bong-Soo;Moon, Joo-Hyun;Park, Byung-Gi;Cho, Young-Ho;Kim, Sin
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.4
    • /
    • pp.201-206
    • /
    • 2009
  • In this study, we have fabricated a fiber-optic radiation sensor for detection of tritium using inorganic scintillators and optical fibers. We have tested various kinds of inorganic scintillators such as $Gd_2O_2S$ : Tb, $Y_3Al_5O_{12}$ : Ce, and CsI : Tl to select the most effective sensor tip. In addition, we have measured the scintillating lights using a photomultiplier tube as a function of distance between sensor tips to the source with the different activities of hydride tritium. The final results are compared with those which are obtained using a surface activity monitor.

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

Mobilizing Learning: Using Moodle and Online Tools via Smartphones

  • Al-Kindi, Salim Said;Al-Suqri, Mohammed Nasser
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.7 no.3
    • /
    • pp.67-86
    • /
    • 2017
  • The emergence of smart devices such as smartphones (e.g., iPhone) and tablets (e.g., iPad) may enhance e-learning by increasing communication and collaborative learning outside the classroom. These devices also facilitate the use of online technologies such as Facebook. However, the adaptation of Learning Management System (LMS) services to mobile devices took longer than social networks or online tools such as Facebook and Twitter have already been long used via smartphone. The main purposes of this study are to explore students' skill levels of LMS (Moodle) and their knowledge of online tools or technologies and then examine if there is a correlation between smartphone use and using of online tools and Moodle in learning. The study conducted among 173 students in the Department of Information Studies (DIS) in Oman, using online survey. The study found that most students demonstrated high levels of accessing course/subject materials and regularly engaging with studies of using LMSs. YouTube, Wikipedia and Facebook were clearly recorded as the most popular sites among students while LinkedIn and Academia.edu were two online tools that had never been heard of by over half of the 142 participants. Emailing and searching are recorded the most popular online learning activities among students. The study concluded that students prefer to use smartphone for accessing these tools rather than using it to access LMSs, while a positive correlation was found between the use of these tools and smartphones, but there was no correlation between smartphones and using LMSs.

An Experimental Study on Effect of External Vessel Cooling for the Penetration Integrity in the KNGR during a Severe Accident (중대사고 시 차세대 원전 관통부의 건전성에 대한 원자로 용기 외벽 냉각의 영향 평가 실험 연구)

  • Kang, K.H.;Park, R.J.;Kim, J.T.;Kim, S.B.;Lee, K.Y.;Park, J.K.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.127-132
    • /
    • 2001
  • An experimental study on penetration integrity of the reactor vessel has been performed under external vessel cooling during a core melt accident. In this study a series of experiments are performed for the verification of the effects of coolant in the annulus between the ICI(In-Core Instrumentation) nozzle and the thimble tube and also the effects of external vessel cooling on the integrity of the penetration using the test section including only one penetration and $Al_{2}O_{3}$ melt as a corium simulant. The experimental results have shown that penetration is more damaged in the case of no external vessel cooling compared with the case of external vessel cooling. It is preliminarily concluded that the external vessel cooling is very effective measure for the improvement of the penetration integrity. Also it is confirmed from the experimental results that the coolant in the annulus reduces the melt penetration distance through the annulus and enhance the integrity of the reactor vessel penetration in the end.

  • PDF