• 제목/요약/키워드: Al implantation

검색결과 78건 처리시간 0.036초

K 및 Al 이중이온주입된 SiO$_2$ 박막의 pH, pNa 및 pK 농도 감지특성에 관한 연구 (A Study on the pH-, pNa- and pK-Sensing Properties of K and Al Coimplanted SiO$_2$ Thin Films)

  • 김병수;신백균;이붕주;이덕출
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권7호
    • /
    • pp.293-297
    • /
    • 2003
  • Silicon dioxide (SiO$_2$) layers were fabricated on Si$_3$N$_4$/SiO$_2$/Si layer structures by low pressure chemical vapor deposition (LPCVD). Potassium and aluminum were then coimplanted by implanting potassium ions with the energy of 100 [keY] and dose of 5x10$^{16}$ [cm ̄$^2$] and 1x10$^{17}$ [cm ̄$^2$] into an aluminum buffer layer on the SiO$_2$Si$_3$N4/SiO$_2$/Si structure. The pH, pNa, and pK ion sensitivities of the resulting layers were investigated and compared to those of as-deposited silicon dioxide layer. The pK-sensitivity of the silicon dioxide was enhanced by the K and Al coimplantation. On the contrary, the pH and pNa-sensitivities of the coimplanted silicon dioxides were quite lower than that of the as-deposited silicon dioxide.

Ti-6Al-4V 비드코팅 임프란트 시제품의 골유착에 대한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE OSSEOINTEGRATION OF THE TI-6AL-4V BEAD COATING IMPLANTS)

  • 우진오;박봉욱;변준호;김승언;김규천;박봉수;김종렬
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권1호
    • /
    • pp.52-59
    • /
    • 2008
  • The geometric design of an implant surface may play an important role in affecting early osseointegration. It is well known that the porous surfaced implant had much benefits for the osseointegration and the early stability of implant. However, the porous surfaced implant had weakness from the transgingival contamitants, and it resulted in alveolar bone loss. The other problem identified with porous surface implant is the loss of physical properties resulting from the bead sintering process. In this study, we developed the new bead coating implant to overcome the disadvantages of porous surfaced implant. Ti-6Al-4V beads were supplied from STARMET (USA). The beads were prepared by a plasma rotating electrode process (PREP) and had a nearly spherical shape with a diameter of 75-150 ${\mu}m$. Two types of titanium implants were supplied by KJ Meditech (Korea). One is an external hexa system (External type) and the other is an internal system with threads (Internal type). The implants were pasted with beads using polyvinylalcohol solution as a binder, and then sintered at 1250 $^{\circ}C$ for 2 hours in vacuum of $10^{-5}$ torr. The resulting porous structure was 400-500 ${\mu}m$ thick and consisted of three to four bead layers bonded to each other and the implant. The pore size was in the range of 50-150 ${\mu}m$ and the porosity was 30-40 % in volume. The aim of this study was to evaluate the osseointegration of the newly developed dental implant. The experimental implants (n=16) were inserted in the unilateral femur of 4 mongrel dogs. All animals were killed at 8 weeks after implantation, and samples were harvested for hitological examination. All bead coated porous implants were successfully osseointegrated with peripheral bone. The average bone-implant contact ratios were 84.6 % (External type) and 81.5 % (Internal type). In the modified Goldner's trichrome staining, new generated mature bones were observed at the implant interface at 8 weeks after implantation. Although, further studies are required, we could conclude that the newly developed vacuum sintered Ti-6Al-4V bead coating implant was strong enough to resist the implant insertion force, and it was easily osseointegrated with peripheral bone.

Teratoma Formation in Immunocompetent Mice After Syngeneic and Allogeneic Implantation of Germline Capable Mouse Embryonic Stem Cells

  • Aldahmash, Abdullah;Atteya, Muhammad;Elsafadi, Mona;Al-Nbaheen, May;Al-Mubarak, Husain Adel;Vishnubalaji, Radhakrishnan;Al-Roalle, Ali;Al-Harbi, Suzan;Manikandan, Muthurangan;Matthaei, Klaus Ingo;Mahmood, Amer
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권10호
    • /
    • pp.5705-5711
    • /
    • 2013
  • Background: Embryonic stem cells (ESCs) have the potential to form teratomas when implanted into immunodeficient mice, but data in immunocompetent mice are limited. We therefore investigated teratoma formation after implantation of three different mouse ESC (mESC) lines into immunocompetent mice. Materials and Methods: BALB/c mice were injected with three highly germline competent mESCs (129Sv, BALB/c and C57BL/6) subcutaneously or under the kidney capsule. After 4 weeks, mice were euthanized and examined histologically for teratoma development. The incidence, size and composition of teratomas were compared using Pearson Chi-square, t-test for dependent variables, one-way analysis of variance and the nonparametric Kruskal-Wallis analysis of variance and median test. Results: Teratomas developed from all three cell lines. The incidence of formation was significantly higher under the kidney capsule compared to subcutaneous site and occurred in both allogeneic and syngeneic mice. Overall, the size of teratoma was largest with the 129Sv cell line and under the kidney capsule. Diverse embryonic stem cell-derived tissues, belonging to the three embryonic germ layers, were encountered, reflecting the pluripotency of embryonic stem cells. Most commonly represented tissues were nervous tissue, keratinizing stratified squamous epithelium (ectoderm), smooth muscle, striated muscle, cartilage, bone (mesoderm), and glandular tissue in the form of gut- and respiratory-like epithelia (endoderm). Conclusions: ESCs can form teratomas in immunocompetent mice and, therefore, removal of undifferentiated ESC is a pre-requisite for a safe use of ESC in cell-based therapies. In addition the genetic relationship of the origin of the cell lines to the ability to transplant plays a major role.

Effects of CF4 Plasma Treatment on Characteristics of Enhancement Mode AlGaN/GaN High Electron Mobility Transistors

  • Horng, Ray-Hua;Yeh, Chih-Tung
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.62-62
    • /
    • 2015
  • In this study, we study the effects of CF4 plasma treatment on the characteristics of enhancement mode (E-mode) AlGaN/GaN high electron mobility transistors (HEMTs). The CF4 plasma is generated by inductively coupled plasma reactive ion etching (ICP-RIE) system. The CF4 gas is decomposed into fluorine ions by ICP-RIE and then fluorine ions will effect the AlGaN/GaN interface to inhibit the electron transport of two dimension electron gas (2DEG) and increase channel resistance. The CF4 plasma method neither like the recessed type which have to utilize Cl2/BCl3 to etch semiconductor layer nor ion implantation needed high power to implant ions into semiconductor. Both of techniques will cause semiconductor damage. In the experiment, the CF4 treatment time are 0, 50, 100, 150, 200 and 250 seconds. It was found that the devices treated 100 seconds showed best electric performance. In order to prove fluorine ions existing and CF4 plasma treatment not etch epitaxial layer, the secondary ion mass spectrometer confirmed fluorine ions truly existing in the sample which treatment time 100 seconds. Moreover, transmission electron microscopy showed that the sample treated time 100 seconds did not have etch phenomena. Atomic layer deposition is used to grow Al2O3 with thickness 10, 20, 30 and 40 nm. In electrical measurement, the device that deposited 20-nm-thickness Al2O3 showed excellent current ability, the forward saturation current of 210 mA/mm, transconductance (gm) of 44.1 mS/mm and threshold voltage of 2.28 V, ION/IOFF reach to 108. As IV concerning the breakdown voltage measurement, all kinds of samples can reach to 1450 V.

  • PDF

$Li^{+}$ 이온 주입된 $Al_2O_3$의 결함 특성 (Defect center of $Li^{+}$ ion implanted $Al_2O_3$)

  • Kim, Tae-Kyu
    • 한국의학물리학회지:의학물리
    • /
    • 제5권2호
    • /
    • pp.13-20
    • /
    • 1994
  • 본 연구에서는 감마선 조사, 전자선 조사방법에 의한 전자만의 주업 및 이온 주업 후 전자선조사 방법으로 전자들이 주입된 $\alpha$-$Al_2O_3$의 열자극 발광(Thermoluminescence : TL)에 관련된 결함 형태를 조사하였다. 감마선 조사된 $\alpha$-$Al_2O_3$의 열자극 발광 곡선은 380K, 415K, 440K, 460K 및 475K에서 TL peak가 나타났다. 광흡수 스펙트럼과 자외선 photobleaching 결과로부터 감마선 조사된 $\alpha$-$Al_2O_3$의 380K와 475K TL peak는 F center에, 415K TL peak는 $F^{+}$ center에 기인함을 알았다. 전자선 조사방법에 의하여 전자 주입된 $\alpha$-$Al_2O_3$의 열자극 발광 곡선은 380K, 415K, 440K 및 460K TL peak를 가졌고, $Li^{+}$ 이온 주입 후 전자선 조사방법으로 전자들이 주입된 $\alpha$-$Al_2O_3$는 440K에서 TL peak가 나타났다. 전자선 조사방법에 의한 전자만의 주입과 $Li^{+}$ 이온 주입 후 전자선 조사방법으로 전자들이 주입된 $\alpha$-$Al_2O_3$의 열자극 발광 특성은 380K TL peak는 F center에, 440K TL peak는 $F^{+}$ center에 기인함을 보였다.

  • PDF

TiN 코팅된 Ti 및 Ti-6Al-4V합금의 부식거동 (Corrosion behaviors of Cp-Ti and Ti-6Al-4V alloys by TiN coating)

  • 이순현;정용훈;최한철;고영무
    • 대한치과기공학회지
    • /
    • 제30권1호
    • /
    • pp.25-31
    • /
    • 2008
  • Cp-Ti and Ti-6Al-4V alloys commonly used dental implant materials, particularly for orthopaedic and osteosynthesis because of its suitable mechanical properties and excellent biocompatibility. This alloys have excellent corrosion behavior in the clinical environment. The first factor to decide the success of dental implantation is sufficient osseointegration and high corrosion resistance between on implant fixture and its surrounding bone tissue. In this study, in order to increase corrosion resistance and biocompatibility of Cp-Ti and Ti-6Al-4V alloy that surface of manufactured alloy was coated with TiN by RF-magnetron sputtering method. The electrochemical behavior of TiN coated Cp-Ti and Ti-6Al-4V alloy were investigated using potentiodynamic (EG&G Co, PARSTAT 2273. USA) and potentiostatic test (250mV) in 0.9% NaCl solution at 36.5 $\pm$ 1$^{\circ}C$. These results are as follows : 1. From the microstructure analysis, Cp-Ti showed the acicular structure of $\alpha$-phase and Ti-6Al-4V showed the micro-acicular structure of ${\alpha}+{\beta}$ phase. 2. From the potentiodynamic test, Ecorr value of Cp-Ti and Ti-6Al-4V alloys showed -702.48mV and -319.87mV, respectively. Ti-6Al-4V alloy value was higher than Cp-Ti alloy. 3. From the analysis of TiN and coated layer, TIN coated surface showed columnar structure with 800 nm thickness. 4. The corrosion resistance of TiN coated Cp-Ti and Ti-6Al-4V alloys were higher than those of the non-coated Ti alloys in 0.9% NaCl solution from potentiodynamic test, indicating better protective effect. 5. The passivation current density of TiN coated Cp-Ti and Ti-6Al-4V alloys were smaller than that of the noncoated implant fixture in 0.9% NaCl solution, indicating the good protective effect resulting from more compact and homogeneous layer formation.

  • PDF

BIOCOMPATIBISITY OF ION BEAM PROCESSED FILMS DEPOSITED ON SURGICAL TI-6AI-4V

  • Lee, I-S;Song and I-j Yu
    • 한국진공학회지
    • /
    • 제6권S1호
    • /
    • pp.16-22
    • /
    • 1997
  • ion beam processing of materials for medical application has gained increasing interest in the last decade and the implantation of nitrogen into TI-6AI-4V to improve corrosive-wear performance is currently used for processing of total hip and knee joints. Oxides and nitrides of Ti, Zr, Al, Cr were deposited on TI-6AI-4V substrates by DC magnetron sputtering dual ion beam sputtering and ion beam assisted deposition. The cytotoxicity of these films were investigated by MTT method and showed comparable to untreated TI-6AI-4V Plasm-sprayed hydroxyapatite(HAp) coatings showed excellent cytotoxicity regardless of heat treatment. intermediate layer coatings of nitrides and oxides increased the bond strength of HAp to substrate by intrdducing chemical bond at interface. Heat treatment of HAp coatings also improved the chemical bond at interfaces and increased the bond strength of untreated TI-6AI-4V to 16.4 kg/$\textrm{cm}^2$ but still lower than 33.1 kg./$\textrm{cm}^2$ of ir oxide as a imtermediate layer caoting.

  • PDF

질소이온 주입에 의한 STD 11강의 내마모 특성변화에 관한 연구 (The study on the change of wear resistance of STD11 steel by nitrogen implantation)

  • 한전건;송건;박진영
    • 한국진공학회지
    • /
    • 제3권4호
    • /
    • pp.449-456
    • /
    • 1994
  • 산업용 주요 냉간금형 소재인 STD 11 강에 질소이온주입하여 이온조입조거에 따른 질화물형성 거동, 경도 및 내마모성 변화에 관해 연구하였다. XRD분석결과 90keV 에너지로 5$\times$1017 ions/cm2 조사 량 이상에서 Fe2N형태의 질화물이 형성되었으며 3$\times$1016 ions/cm2 범위의 모든 조사량에서 경도 및 조 사량에서 경도 및 내마모성 향상효과를 얻었다. Al2O3와의 ball-on-disc 마모거동 분석결과 STD 11모재 는 응착마모와 산화마모의 혼합형태로 마모되는 반면 질소이온주입한 경우 산화마모 경향이 강하게 나 타났다.

  • PDF

Si Nanostructure on Graphene

  • Han, Yong;Kim, Heeseob;Hwang, Chan-Cuk;Lee, Hangil;Kim, Bongsoo;Kim, Ki-jeong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.184.1-184.1
    • /
    • 2014
  • Nanostructures on Graphene surface receive highly attraction for many applications ranging from sensing technologies to molecular electronics. Recently J. Jasuja et al. reported the electrical property tailoring and Raman enhancement by the implantation and growth of dendritic gold nanostructures on graphene derivatives [ACSNANO, 3, 2358, 2013] Here, we introduced Si vapor on the graphen to induce the nanostructure. The surface property change of graphene by controlling the amount of Si and the thickness of graphene were investigated using high resolution photoemission spectroscopy (HRPES), and atomic force microscopy (AFM). The Si nanostructures on graphene show the thickness dependency of graphene, and the size of Si nano-structure reached to 7 nm and 15 nm on the mono and the multilayered graphene after $30{\AA}$ Si evaporation.

  • PDF

대혈관전위증 수술 3례 보 (Operation using valved conduit in TGA: report of 3 cases)

  • 유회성
    • Journal of Chest Surgery
    • /
    • 제16권4호
    • /
    • pp.452-457
    • /
    • 1983
  • Transposition of great arteries is relatively common cyanotic heart disease excluding TOF and is divided to two groups: complete TGA and congenitally corrected TGA. We experienced operations in 3 cases of TGA, the 1st case was 12 year-old male: TGA[SDD] + VSD+PS and treated with Rastelli`s operation, but expired due to low cardiac output syndrome postoperatively. The 2nd case,13 year-old male was also TGA[SDD]+VSD+PS and treated with Rastelli`s operation with good operative result. The 3rd case was 18-year old male: congenitally corrected TGA[SLL]+VSD+ PA+ASD and operation was done according to the met. hod reported by Danielson et al in 1980. Post-operative AV block led to implantation of permanent epicardial pacemaker with good result.

  • PDF