• Title/Summary/Keyword: Al concentration

Search Result 1,827, Processing Time 0.043 seconds

Petrochemistry and Geologic Structure of Icheon Granitic Gneiss around Samcheog Area, Korea (삼척지역 이천화강편마암의 암석화학과 지질구조)

  • Cheong Won-Seok;Cheong Sang-Won;Na Ki-Chang
    • The Journal of the Petrological Society of Korea
    • /
    • v.15 no.1 s.43
    • /
    • pp.25-38
    • /
    • 2006
  • Metamophic rocks of Samcheog area, northeastern Yeongnam massif, was studied petrochemically. This area includes Precambrian Hosanri Formation (schists and gneisses) and granitoid (Icheon granitic gneiss, leucocratic granite and Hongjesa granite), Cambrian sedimentary rocks, and Cretaceous sedimentary and acidic volcanic rocks. Hosanri formation is composed of quartz+plagioclase+K-feldspar+biotite+muscovite+granet${\pm}$cordierite${\pm}$sillimanite. Mineral assemblage of biotite granitic gneiss, which is massive granodioritic rock with weak foliation, is similar to Hosanri formation. According to mineral assemblages, metamorphic rocks of studied area can be divided into two metamorphic zones (garnet and sillimanite zones). From Icheonri area, major, trace and rare earth element data of biotite granitic gneiss and luecocratic granite suggest that source rock is politic rocks of Hosanri formation and source magma was formed by anatexis and experienced fractionation of plagioclase. Trace element diagram show collisional environment such as syn-collisional, volcanic arc granite. Orientation of faults in study area have three maximum concentrations, $N54^{\circ}\;W/77^{\circ}\;SW,\;N49^{\circ}\;W/81^{\circ}\;NE\;and\;N10^{\circ}\;W/38^{\circ}\;NE$. Structure analysis suggests that faults in study area ware formed by uplift and compression. Faulting age is guessed after Tertiary because some shear joints is developed in dikes to intrusive Cretaceous acidic volcanic rock. Hosanri formation and Icheon granitic gneiss had experienced similar deformation history because they have maximum concentration to foliations, $N89^{\circ}\;E/55^{\circ}\;SE\;and\;N80^{\circ}\;E/45^{\circ}\;SE$, respectively.

The Effect of Nasal CPAP in Obstructive Sleep Apnea Syndrome (폐쇄형 수면무호흡증후군 환자에서 Nasal CPAP의 치료 효과)

  • Kim, Chi-Hong;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.501-508
    • /
    • 1993
  • Background: Sleep apnea syndrome is a common disorder which is estimated to affect about 1~4% of adult male population. And if untreated, sleep apnea can cause significant sequelae, such as hypertension, nocturnal cardiac arrhythmia, daytime hypersomnolence, and cognitive impairment. Various kinds of treatment for obstructive sleep apnea (OSA) have been developed. Among them nasal CPAP, first introduced by Sullivan et al in 1981, has received widespread interest and acclaim as a treatment of OSA, and is currently recommended as first-line treatment for OSA. We evaluated the effect of nasal CPAP in OSA and the side effects of nasal CPAP hindering patients from using nasal CPAP. Methods: We performed sleep studies in 20 OSA patients at 2 consecutive nights; baseline night at first day and CPAP night at second day. We compared apnea index, lowest oxygen concentration during apnea, maximal apnea time, and total apnea duration per total sleep time before and after CPAP. We also evaluated the side effects of CPAP with inquiry to the patients. Results: 1) Apnea index was significantly decreased after CPAP in 17 out of 20 OSA patients (85%) and increased in 3 patients (15%). 2) Average apnea index was significantly decreased after CPAP ($34.1{\pm}18.9/h{\rightarrow}15.4{\pm}10.3/h$, p<0.01). 3) Total apnea duration per total sleep time was also significantly decreased after CPAP ($28.5{\pm}16.0%{\rightarrow}11.9{\pm}9.3%$, p<0.05). 4) The lowest oxygen satuation and maximal apnea time were not significantly changed after CPAP. 5) The most frequent side effect of nasal CPAP was mask discomfort (80%), and the next was drying of nasal passages (65%). Conclusion: Nasal CPAP is an effective treatment for OSA. Futher studies should be concentrated on long term follow up of nasal CPAP for its therapeutic effects and the study of methods to enhance patients' compliance.

  • PDF

Transformation of Populus nigra × P. maximowiczii Using Agrobacterium tumefaciens vectors (Agrobacterium tumefaciens vector를 이용(利用)한 양황철의 형질전환(形質轉換))

  • Son, Suk Gyu;Hyu, Jung Oh
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.2
    • /
    • pp.164-172
    • /
    • 1998
  • This study was conducted to find the optimum transformation condition using Agrobacterium harboring promoterless GUS gene. The optimal medium for shoot induction from leaves of Populus nigra${\times}$P. maximowiczii was MS medium supplemented with $0.1mg/{\ell}$ NAA, $0.5mg/{\ell}$ BAP(94% regeneration frequency and 11.5 average number of shoot) According to the test using pBI121, the concentration of antibiotics for selection marker gene was $100mg/{\ell}$ kanamycin or $60mg/{\ell}$ geneticin in the SIM(shoot inducing medium) 3. Two weeks later, callus was induced in the SIM 3 and this callus grew up to 0.5-1cm shoots after 6 weeks in the new SIM 3. And the treatment with methylation inhibitor(5-azacytidine) led to a dramatic increase in foreign gene expression rate from 5.7% to 26.7%. The vector systems showed. different transformation efficiencies based on the fluorometric and histochemical GUS assay. In this study the vector systems used for transformation seemed to affect transformation frequency, in which pEHA101 yielded more transformants(35.9%) than LBA4404/pBI121 did(5.7%). This result indicated that pEHA101 was effective to insert the promoterless foreign gene into a poplar genome.

  • PDF

The Physiochemical Characteristics of Seawater and Sediment of Marine Shellfish Farm in Jindong Bay (진동만 패류양식해역의 환경특성)

  • Jeong, Woo-Geon;Cho, Sang-Man
    • The Korean Journal of Malacology
    • /
    • v.19 no.2
    • /
    • pp.161-169
    • /
    • 2003
  • Seawater and sediment quality analysed was calculated to examinate the present environmental characteristics and pollution load was also calculated to evaluate the effect of farming area on the coastal environment. The measurements for seawater quality demonstrate the coastal environment has relatively eutrophicated with significantly decreased DO (0.2-8.5 mg/l) and elevated COD (9.6-31.2 mg/l) in summer. It was also evident that the water quality in Jindong Bay has been influenced by residues tide from Masan Bay with high metal concentration in August of 2002. Annual total pollution load (land and farm-driven) was estimated at 37,316 ton (SS) /yr: 9,809 ton/yr (26.3%) of land-driven load, 23,576 ton/yr (63.2%) of coastal sedimentation and 3,932 ton/yr (10.5%) of feces of cultural organisms. When all ark shell seedling farms are permitted species conversion to ascidian farm, the pollution load would increase by 196%, which may be another source for accelerating the eutrophication of the environment in Jindong Bay.

  • PDF

Characterization of Concentrations of Fine Particulate Matter in the Atmosphere of Pohang Area (포항지역 대기 중 초미세먼지(PM$_{2.5}$)의 오염특성평가)

  • Baek, Sung-Ok;Heo, Yoon-Kyeung;Park, Young-Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.3
    • /
    • pp.302-313
    • /
    • 2008
  • The purposes of this study are to investigate the concentration levels of fine particles, so called PM$_{2.5}$, to identify the affecting sources, and to estimate quantitatively the source contributions of PM$_{2.5}$. Ambient air sampling was seasonally carried out at two sites in Pohang(a residential and an industrial area) during the period of March to December 2003. PM$_{2.5}$ samples were collected by high volume air samplers with a PM$_{10}$ Inlet and an impactor for particle size segregation, and then determined by gravimetric method. The chemical species associated with PM$_{2.5}$ were analyzed by inductively coupled plasma spectrophotometery(ICP) and ion chromatography(IC). The results showed that the most significant season for PM$_{2.5}$ mass concentrations appeared to be spring, followed by winter, fall, and summer. The annual mean concentrations of PM$_{2.5}$ were 36.6 $\mu$g/m$^3$ in the industrial and 30.6 $\mu$g/m$^3$ in the residential area, respectively. The major components associated with PM$_{2.5}$ were the secondary aerosols such as nitrates and sulfates, which were respectively 4.2 and 8.6 $\mu$g/m$^3$ in the industrial area and 3.7 and 6.9 $\mu$g/m$^3$ in the residential area. The concentrations of chemical component in relation to natural emission sources such as Al, Ca, Mg, K were generally higher at both sampling sites than other sources. However, the concentrations of Fe, Mn, Cr in the industrial area were higher than those in the residential area. Based on the principal component analysis and stepwise multiple linear regression analysis for both areas, it was found that soil/road dust and secondary aerosols are the most significant factors affecting the variations of PM$_{2.5}$ in the ambient air of Pohang. The source apportionments of PM$_{2.5}$ were conducted by chemical mass balance(CMB) modeling. The contributions of PM$_{2.5}$ emission sources were estimated using the CMB8.0 receptor model, resulting that soil/road dust was the major contributor to PM$_{2.5}$, followed by secondary aerosols, vehicle emissions, marine aerosols, metallurgy industry. Finally, the application and its limitations of chemical mass balance modeling for PM$_{2.5}$ was discussed.

Lipoprotein and Lipid Abnormalities in Uremic Children with Maintenance Dialysis (투석 치료중인 만성 신부전 소아에서의 지질 및 지질단백 이상)

  • Kim Jung-Sue;Song Jung-Han;Park Hye-Won;Cheong Hae-Il;Kim Jin-Q;Choi Yong;Ko Kwang-Wook
    • Childhood Kidney Diseases
    • /
    • v.1 no.2
    • /
    • pp.109-116
    • /
    • 1997
  • Purpose : Chronic renal failure is often accompanied by severe dyslipidemia, a known risk factor for cardiovascular disease. Lipoprotein(a) [Lp(a)] has recently been characterized as a risk factor for atherosclerosis and thrombosis. Cardiovascular disease is the leading cause of death in adult patients on dialysis. However, there are only limited data available concerning risk factors for atherosclerosis in uremic children. We have measured serum levels of lipids, lipoproteins, apolipoproteins and Lp(a) in uremic children with maintenance dialysis. Methods : Ten uremic children with hemodialysis (HD) and 14 with peritoneal dialysis (PD) in our dialysis unit were included in this study. The mean age of HD patients was $162{\pm}59$ months and the male to female ratio was 7:3. The mean age and sex ratio of PD patients were $123{\pm}63$ months and 6:8, respectively. The levels of cholesterol, triglyceride, lipoproteins, apolipoproteins and Lp(a) were measured from serum sampled after 14 hours of fasting. The normal control levels were cited from 2 articles presenting the normal blood lipid and lipoprotein levels of primary school and middle school children in Korea. Results : There was no difference in age, sex ratio, body mass index and duration of dialysis between the HD and the PD group. The serum concentration of the cholesterol, triglyceride and apolipoprotein B were significantly elevated in dialysis patients compared with normal subjects. The serum level of Lp(a) was significantly elevated in only PD group. The serum Lp(a) level was below 30 mg/dl in 13 and above 30 mg/dl in 11 patients. The serum albumin level was significantly decreased in high Lp(a) group than in low Lp(a) group. Conclusion : The uremic children receiving dialysis reveal abnormal serum lipid and lipoprotein profiles. These results suggest that they have a higher risk for coronary heart disease, although there has been no clinical evidence of coronary heart disease at present. A long-term follow-up study of these children to clarify the suggestion should be started now.

  • PDF

Ni/Au Electroless Plating for Solder Bump Formation in Flip Chip (Flip Chip의 Solder Bump 형성을 위한 Ni/Au 무전해 도금 공정 연구)

  • Jo, Min-Gyo;O, Mu-Hyeong;Lee, Won-Hae;Park, Jong-Wan
    • Korean Journal of Materials Research
    • /
    • v.6 no.7
    • /
    • pp.700-708
    • /
    • 1996
  • Electroless plating technique was utilized to flip chip bonding to improve surface mount characteristics. Each step of plating procedure was studied in terms pf pH, plating temperature and plating time. Al patterned 4 inch Si wafers were used as substrstes and zincate was used as an activation solution. Heat treatment was carried out for all the specimens in the temperature range from room temperature to $400^{\circ}C$ for $30^{\circ}C$ minutes in a vacuum furnace. Homogeneous distribution of Zn particles of size was obtained by the zincate treatment with pH 13 ~ 13.5, solution concentration of 15 ~ 25% at room temperature. The plating rates for both Ni-P and Au electroless plating steps increased with increasing the plating temperature and pH. The main crystallization planes of the plated Au were found to be (111) a pH 7 and (200) and (111) at pH 9 independent of the annealing temperature.

  • PDF

Optimization Test of Plant-Mineral Composites to Control Nuisance Phytoplankton Aggregates in Eutrophic Reservoir (부영양 저수지의 조류제거를 위한 기능성 천연물질혼합제의 최적화 연구)

  • Lee, Ju-Hwan;Kim, Baik-Ho;Moon, Byeong-Cheon;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.1
    • /
    • pp.31-41
    • /
    • 2011
  • To optimize the natural chemical agents against nuisance phytoplankton, we examined algal removal activity (ABA) of Plant-Mineral Composite (PMC), which already developed by our teams (Kim et al., 2010), on various conditions. The PMC are consisted of extracted-mixtures with indigenous plants (Camellia sinensis, Quercusacutissima and Castanea crenata) and minerals (Loess, Quartz porphyry, and natural zeolite), and characterized by coagulation and floating of low-density suspended solids. A simple extraction process was adopted, such as drying and grinding of raw material, water-extraction by high temperature-sonication and filtering. All tests were performed in 3 L plastic chambers varying conditions; six different concentrations ($0{\sim}1.0\;mL\;L^{-1}$), six light intensities ($8{\sim}1,400\;{\mu}mol\;m^{-2}s^{-1}$), three temperatures ($10{\sim}30^{\circ}C$), four pHs (7~10), five water depths (10~50 cm), and three different waters dominated by cyanobacteria, diatom, and green algae, respectively. Results indicate that the highest ABA of PMC was seen at $0.05\;mL\;L^{-1}$ in treatment concentrations, where showed a reduction of more than 80% of control phytoplankton biomass, while $1,400\;{\mu}mol\;m^{-2}s^{-1}$ in light intensity (>90%), $20{\sim}30^{\circ}C$ temperature (>60%), 7~9 in pH (>90%), below 50 cm in water depth (>90%), and cyanobacterial dominating waters (>80%), respectively. Over the test, ABA of PMC were more obvious on the algal biomass (chlorophyll-${\alpha}$) than suspended solids, suggesting a selectivity of PMC to particle size or natures. These results suggest that PMC agents can play an important role as natural agents to remove the nuisant algal aggregates or seston of eutrophic lake, where occur cyanobacterial bloom in a shallow shore of lake during warm season.

Quality Assessment of Fried Soybean Curd during Different Storage Condition (저장조건에 따른 유부의 품질평가)

  • Kim, Dong-Su;Park, Hyeon-Su;Kim, Hyeon-Dae
    • The Korean Journal of Food And Nutrition
    • /
    • v.10 no.4
    • /
    • pp.514-520
    • /
    • 1997
  • The study was carried out to investigate the changes of quality and to determine the optimal shelf-life of fried soybean curd under low temperature(8$\pm$2$^{\circ}C$) and room temperature(25-3$0^{\circ}C$), respectively. The quality criteria for fried soybean were acid value, peroxide value, fatty acid composition and microbial concentration, et al. The initial moisture content of fried soybean curd was 41.9%, it was rapidly decreased to 29.6% until the second days under low temperature. The pH value was 5.7 and 5.8 at the ninth days under 8$\pm$2$^{\circ}C$ and the sixth days under 25-3$0^{\circ}C$, respectively. Also, the acid value rised remarkly to 10.65 at the fifth days and the peroxide value was 12.20 at the sixth days under room temperature. The viable cell counts were 1.0$\times$1.0 at the initial storage, but they were increased to 6.1$\times$105 over at the second days of room temperature. Moreover, the mold colony counts were in 2.0$\times$10-6.0$\times$103 and 2.0$\times$10=8.5$\times$107 during all storage days under 8$\pm$2$^{\circ}C$ and 25-3$0^{\circ}C$, respectively.

  • PDF

Quality Characteristics and Antioxidant Activity of Spirulina added Yogurt (스피루리나 첨가 요구르트의 품질 특성 및 항산화능)

  • Shin, Yu-Mi;Son, Chan-Wok;Sim, Hyun-Jung;Kim, Min-Hee;Kim, Mi-Yeon;Kwon, Oh-Yun;Kim, Mee-Ree
    • Korean journal of food and cookery science
    • /
    • v.24 no.1
    • /
    • pp.68-75
    • /
    • 2008
  • The aim of this study was to evaluate the quality characteristics and antioxidant activity of yogurt containing spirulina. Yogurt base was prepared from skim milk added with $0.25{\sim}1%(w/v)$ spirulina powder and fermented with lactic acid bacteria (S. thermophilus : L. bulgaricus = 1 : 1) at $40^{\circ}C$ for 12 hr. Kiwi puree and oligosaccharides were then added. The addition of 1% spirulina powder stimulated the growth of lactic acid bacteria, which showed the highest viable cell count ($3.4{\times}10^9$ CFU/mL), and increased the titratable acidity (1.10%). The viscosity range of the yogurt was 6,000 to 9,000 cP, and the sugar content of the yogurt was around 18 $^{\circ}Brix$. The antioxidant activities were determined using the DPPH method, and the hydroxyl radical scavenging activity of the yogurt containing spirulina was higher than that of the control. The sensory evaluation scores for appearance, odor, taste, overall acceptability and buying intention were higher in the yogurt containing 0.25% spirulina than in the other groups. The amount of macronutrients in the yogurt containing spirulina was higher than that in the control. In addition, the amounts of micronutrients in the yogurt containing spirulina was significantly increased. According to these results, the optimum concentration of spirulina powder is around 0.25%.