Modeling of Turbulent Ventilation through an Opening due to Outdoor Pressure Fluctuations (개구부를 통한 외부압력 변동에 의한 난류환기 모델링)

  • Han, Hwa-Taik;Yom, Chol-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.121-127
    • /
    • 2008
  • This paper investigates the effects of outdoor pressure fluctuations on natural ventilation through an opening on a building envelope. The ventilation airflow rate depends on the magnitude and the period of the pressure fluctuations, the size of the opening relative to the space volume, and the resistance characteristics of the opening. Non-dimensional parameters have been derived, which determine indoor pressure responses due to outdoor pressure fluctuations. The flow regions are categorized into (1) synchronized region, (2) opening resistance region, and (3) transition region depending on the non-dimensional parameter derived. Pressure fluctuations and flow characteristics are investigated numerically using the 4th order Runge-Kutta method.

Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space (바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향)

  • 정광섭;한화택;홍승재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

Experimental Studies for Solar Drying System of Agricultural Products(I) - Solar drying characteristics for radish - (태양열 건조 시스템에 관한 실험적 연구(I) - 무우절편의 태양열 건조 특성 -)

  • Koh, Hak-Kyun;Kim, Yong-Hyeon;Song, Dae-Bin;Kim, Man-Soo
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.9-20
    • /
    • 1991
  • Experiments for drying radish were carried out to analyze the drying characteristics and quality evaluation between solar heated-air drying and natural air drying system. Solar heated-air drying system consists of a small fan, a solar air heater and a tunnel dryer. Simulation model for thermal environments of solar collector was developed to investigate the effect of solar radiation and airflow rate on thermal performance.

  • PDF

Slim-Type ODD에서 디스크 부상에 관한 연구

  • Lee, Jae-Sung;Rhim, Yoon-Chul
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.2
    • /
    • pp.156-162
    • /
    • 2006
  • In this paper, we have investigated the disc warping in high-speed slim-type optical disc drive. The track density as well as high rotational speed of the information storage devices must be increased to enhance their recording capacity and data transfer rate. Generally, ODD used in the Lap-top computer has small inner space. So, the flow instability of the inner space is increased rapidly with its rotational speed. In extreme case, the flow instability may cause the malfunction of the read/write pick-up of drives. The experiments and numerical analysis were carried out for several cases and the result shows the influence of airflow to the disc warping.

  • PDF

Experimental study on air-water countercurrent flow limitation in a vertical tube based on measurement of film thickness behavior

  • Wan, Jie;Sun, Wan;Deng, Jian;Pan, Liang-ming;Ding, Shu-hua
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1821-1833
    • /
    • 2021
  • The gas-liquid counter-current flow limitation (CCFL) is closely related to efficient and safety operation of many equipment in industrial cycle. Air-water countercurrent flow experiments were performed in a tube with diameter of 25 mm to understand the triggering mechanism of CCFL. A parallel electrode probe was utilized to measure film thickness whereby the time domain and frequency domain characteristics of liquid film was obtained. The amplitude of the interface wave is small at low liquid flow rate while it becomes large at high liquid flow rate after being disturbed by the airflow. The spectral characteristic curve shows a peak-shaped distribution. The crest exists between 0 and 10 Hz and the amplitude decreases with the frequency increase. The analysis of visual observation and characteristic of film thickness indicate that two flooding mechanisms were identified at low and high liquid flow rate, respectively. At low liquid flow rate, the interfacial waves upward propagation is responsible for the formation of CCFL onset. While flooding at high liquid flow rate takes place as a direct consequence of the liquid bridging in tube due to the turbulent flow pattern. Moreover, it is believed that there is a transition region between the low and high liquid flow rate.

Internal Flow Dynamics and Performance of Valveless Airbreathing Pulse Detonation Engine (무-밸브 공기흡입 펄스데토네이션 엔진의 내부 유동과 성능)

  • Ma Fuhua;Choi J.Y.;Yang Vigor
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.367-370
    • /
    • 2006
  • This paper deals with the modeling and simulation of the internal flowfield in a valveless airbreathing pulse detonation engine (PDE) currently under experimental development at the U.S. Naval Postgraduate School. The system involves no valves in the airflow path, and the isolation between the inlet and combustor is achieved through the gasdynamics in an isolator. The analysis accommodates the full conservation equations in axisymmetric coordinates, and takes into account variable properties for ethylene/oxygen/air system. Chemical reaction schemes with a single progress variable are implemented to minimize the computational burden. Detailed flow evolution during a full cycle is explored and propulsive performance is calculated. Effect of initiator mass injection rate is examined and results indicate that the mass injection rate should be carefully selected to avoid the formation of recirculation zones in the initial cold flowfield. Flow evolution results demonstrate a successful detonation transmission from the initiator to the combustor. However, strong pressure disturbance may propagate upstream to the inlet nozzle, suggesting the current configuration could be further refined to provide more efficient isolation between the inlet and combustor.

  • PDF

Effect of Anion Generating Air Cleaner on the Components of ETS in a Closed Room (음이온 발생 공기청정기에 의한 밀폐된 실내공간에서의 ETS성분 변화)

  • Hwang, Keon-Joong;Rhee, Moon-Soo;Ra, Do-Young
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.1
    • /
    • pp.124-130
    • /
    • 1998
  • This study was conducted to evaluate the ability of anion generating air cleaner to remove gases, vapor and particles from closed room contaminated with environmental tobacco smoke (ETS). The measurements covered particle sizes of 13.8-542.5nm, particle concentration, surface area, volumes UVPM, FPM, solanesol, and the following gases and vapor; carbon dioxide, carbon monoxide, nicotine, and 3-ethenylpyridine. Tobacco smoke was generated and mixed in a closed room in which the airflow rates were in the range of 0.00-0.04 m/s. The anion generating air cleaner was startedl and the decay rates for the gases, vapor and particles were measured, When the use of anion generating air cleaner, solid components of ETS, such as respirable suspended particle (RSP), utraviolet particulate matter (UVPM, fluorescent particulate matter (FPM) and solanesol was sharply decreased, and vapor phase components of ETS, such as nicotines 3-ethenylpyidine were modelately decreased by time elapse. Even the use of anion generation air cleaner, the decreasing rate of carbon dioxide concentration was similar with control, and the decreasing rate of carbon monoxide was slower than that of control. Our results indicated that the use of anion generting air cleaner had an effect on reduction of solid and vapor components from ETs, but it had no effect on gaseous components of ETS.

  • PDF

Uncertainty Analysis and Improvement of an Altitude TestFacility for Small Jet Engines

  • Jun, Yong-Min;Yang, In-Young;Kim, Chun-Taek;Yang, Soo-Seok;Lee, Dae-Sung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.5 no.1
    • /
    • pp.46-56
    • /
    • 2004
  • The verification and improvement of the measurement uncertainty have beenperformed in the altitude test facility for small gas turbine engines, which was built atthe Korea Aerospace Research Institute (KARI) in October 1999. This test is performedwith a single spool turbojet engine at several flight conditions. This paper discussesthe evaluation and validation process for the measurement uncertainty improvements usedin the altitude test facility. The evaluation process, defined as tests before the facilitymodification, shows that the major contnbutors to the measurement uncertainty are theflow meter discharge coefficient, the inlet static and total pressures, the cell pressureand the fuel flow rate. The measurement uncertainty is focused on the primary parametersof the engine performance such as airflow rate, thrust and specific fuel consumption (SFC).The validation process, defined as tests after the facility modification, shows that themeasurement uncertainty, in seal level condition, is tmproved to the acceptable level throughthe facility modification. In altitude test conditions, the measurement uncertainties arenot improved as much as the uncertainty in sea level condition.

Effect of Different Carrier Agents on Physicochemical Properties of Spray-dried Pineapple (Ananas comosus Merr.) Powder

  • Quoc, Le Pham Tan
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.5
    • /
    • pp.259-266
    • /
    • 2020
  • The main purpose of this study is to examine the different physicochemical properties of spray-dried products. The carrier agents and powders after the spray-drying process were analyzed for encapsulation yield, moisture content, color parameters, total polyphenol content (TPC), antioxidant capacity (AC), bulk density, flowability, wettability, hygroscopicity, water solubility index (WSI), particle size and microstructure. The spray-drying process was carried out with different carrier agents including maltodextrin (MD) and the combination of maltodextrin and gum arabic (MD-GA) with MA/GA ratio of 70/30, dried at the inlet/outlet air temperature of 160 ℃/70 ℃, 4 bar, airflow rate of 70 ㎥·h-1 and feed flow rate of 750 mL·h-1. The results showed that the different carrier agents have significant influences on the physicochemical properties of the powder produced by the spray-drying method. In there, while the values of recovery efficiency and flowability of spray-dried products from MD are higher than those of spray-dried products from MD-GA combination, the opposite is true for the values of TPC, AC, bulk density and wettability, whereas hygroscopicity and WSI values are equally represented in both products.

Optimal Criterion for the Scale-Up Production of Schizophyllan in the Stirred Tank Reactor

  • KWAK, JUNG-KI;KOO, JAE-GUEN;PARK, SUNG-WOO;CHO, MAN-GI;KANG, BYEONG-CHUL;RAINER BUCHHOLZ;PETER GOETZ
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • Optimal criterion for the scale-up production of schizophyllan, a fungal polysaccharide secreted by Schizophyllum commune, was investigated. For the production of the polysaccharide in a 150-l bioreactor, the culture conditions optimized in a 15-l bioreactor were applied to a 150-l bioreactor with scale-up process, by changing impeller speed and airflow rate. The optimized impeller speed in the 15-l bioreactor was 50 rpm in a technical medium based on barley. For establishment of the scale-up process, 3 kinds of criteria were used while the gas throughput number was kept constant, as follows; constant volume-related power input, constant tip speed of stirrer, and constant Reynolds number. In the 150-l bioreactor, the highest values for the maximum specific growth rate (1.17/day) and productivity (0.63 g/L${\cdot}$day) were achieved in the culture condition from constant volumerelated power input criterion.