• Title/Summary/Keyword: Airflow rate

Search Result 223, Processing Time 0.026 seconds

Selection of Filamentous Cyanobacteria and Optimization of Culture Condition for Recycling Waste Nutrient Solution (폐양액 활용을 위한 Filamentous Cyanobacteria의 선발 및 최적배양)

  • Yang, Jin-Chul;Chung, Hee-Kyung;Lee, Hyoung-Seok;Choi, Seung-Ju;Yun, Sang-Soon;Ahn, Ki-Sup;Sa, Tong-Min
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.3
    • /
    • pp.177-183
    • /
    • 2004
  • The discharge of waste nutrient solution from greenhouse to natural ecosystem leads to the accumulation of excess nutrients that results in contamination or eutrophication. There is a need to recycle the waste nutrient solution in order to prevent the environmental hazards. The amount and kind of nutrients in waste nutrient solution might be enough to grow photosynthetic microorganisms. Hence in the present study, we examined the growth and mass cultivation of cyanobacteria in the waste nutrient solution with an objective of removing N and P and concomitantly, its mass cultivation. Four photosynthetic filamentous cyanobacteria (Anabaena HA101, HA701 and Nostoc HN601, HN701) isolated from composts and soils of the Chungnam province were used as culture strains. Among the isolates, Nostoc HN601 performed faster growth rate and higher N and P uptake in the BG-II ($NO_3{^-}$) medium when compared to those of other cyanobacterial strains. Finally, the selected isolate was tested under optimum conditions (airflow at the rate of $1L\;min^{-1}$. in 15 L reactor, initial pH 8) in waste nutrient solution from tomato hydroponic in green house condition. Results showed to remove 100% phosphate from the waste nutrient solution in the tomato hydroponics recorded over a period of 7 days. The growth rate of Nostoc HN601 was $16mg\;Chl-a\;L^{-1}$ in the waste nutrient solution from tomato hydroponics with optimum condition, whereas growth rate of Nostoc HN601 was only $9.8mg\;Chl-a\;L^{-1}$ in BG-11 media. Nitrogen fixing capacity of Nostoc HN601 was $20.9nmol\;C_2H_4\;mg^{-1}\;Chl-a\;h^{-1}$ in N-free BG-11. The total nitrogen and total phosphate concentration of Nostoc HN601 were 63.3 mg N gram dry weight $(GDW)^{-1}$ and $19.1mg\;P\;GDW^{-1}$ respectively. Collectively, cyanobacterial mass production using waste nutrient solution under green house condition might be suitable for recycling and cleaning of waste nutrient solution from hydroponic culture system. Biomass of cyanobacteria, cultivated in waste nutrient solution, could be used as biofertilizer.

A Case Study on the Ventilation and Heat Environment in a Underground Limestone Mine with Rampway (Rampway 설치 석회석 광산내 환기 현황 및 열환경 분석 사례연구)

  • Kim, Doo-Young;Lee, Seung-Ho;Jeong, Kyu-Hong;Lee, Chang-Woo
    • Tunnel and Underground Space
    • /
    • v.22 no.3
    • /
    • pp.163-172
    • /
    • 2012
  • As more diesel engines have been employed in underground limestone mines with large cross section, underground space environment is worsened by diesel exhausts and heat flow. This paper aims for the ultimate goal to optimize the work place environment through assuring the optimal required ventilation rate based on the analysis of the airflow, diesel exhaust gas concentrations and the effects of mechanization and deepening working face on temperature and humidity. Due to the insufficient capacity of the main exhaust fan and poor airway management, stagnant airflows were observed at various locations, while the flow direction was reversed instantly with passing diesel equipment and the flow reversal was also made by the seasonal variation of the outside surface weather. During the loading operation, CO concentration measurements were found to be frequently higher than the threshold limit of 50 ppm, and most of the $NO_2$ measurements during drilling and loading operations shows even more serious levels surpassing the permissible limit of 3 ppm. The actual ventilation quantity was considerably less than the required quantity estimated by the mine health and safety law, and this shortage problem was less serious in colder winter showing more effectiveness of the natural ventilation.

The effect of PDGF-BB loaded TCP/chitosan microgranules on new bone formation (혈소판유래성장인자를 함유한 TCP-chitosan 미세과립이 신생골조직 형성에 미치는 영향에 관한 연구)

  • Seol, Yang-Jo;Lee, Jue-Yeon;Kye, Seung-Beom;Lee, Young-Kyu;Kim, Won-Kyeong;Lee, Yong-Moo;Ku, Young;Han, Soo-Boo;Lee, Seung-Jin;Chung, Chong-Pyoung;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.489-500
    • /
    • 2002
  • The purpose of this study was to evaluate newly fabricated tricalcium phosphate(TCP)/chitosan microgranuls as bone substitutes. TCP/chitosan microgranules were fabricated by dropping TCP-chitosan suspension into the NaOH/ethanol solution. The size of microgranules could be controllable via airflow rate. PDGF-BB was loaded into the fabricated granules via freeze-drying methods(300 ng/20 mg). To evaluate cell proliferation, cultured osteoblasts cell lines(MC3T3-El) was dropped on the BioOss(R), chitosan microgranules, TCP/chitosan microgranules and cultured for 1, 7 , 14, and 28 days. Scanning electron microscopic observation was done after 7 days of culture and light microscopic examination was done after 28 days of culture. PDGF-BB release from the microgranules was tested. Rabbit calvarial defects(8 mm in diameter) were formed and chitosan, TCP/chitosan, PDGF-TCP/chitosan microgranules, and BioGran(R) were grafted to test the ability of new bone formation. At SEM view, the size of prepared microgranules was 250-1000 um and TCP powders were observed at the surface of TCP/chitosan microgranules. TCP powders gave roughness to the granules and this might help the attachment of osteoblasts. The pores formed between microgranules might be able to allow new bone ingrowth and vascularization. There were no significant differences in cell number among BioOss(R) and two microgranules at 28 day. Light and scanning electron microscopic examination showed that seeded osteoblastic cells were well attached to TCP/chitosan microgranules and proliferated in a multi-layer. PDGF-BB released from TCP/chitosan microgranules was at therapeutic concentration for at least 1 week. In rabbit calvarial defect models, PDGF-TCP/chitosan microgranules grafted sites showed thicker bone trabeculae pattern and faster bone maturation than others. These results suggested that the TCP/chitosan microgranules showed the potential as bone substitutes.

Evaluation of characteristics for microbubble generation according to venturi nozzle specification (벤튜리 노즐 제원에 따른 마이크로버블 발생 특성 평가)

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6397-6402
    • /
    • 2015
  • This research was performed to review operating parameters, optimum condition and check characteristic of microbubble generation for using bubble size distribution according to venturi specification. Optimum operating condition have airflow rate 0.3 LPM, 3 bar(pressure tank) and connecting nozzle directly(without valve), it is advantageous to generate microbubble. In case of characteristic of microbubble generation according to venturi specification, effect that nozzle specification affects bubble size distribution is low impact. But considering performance aspects, when using nozzle that throat diameter 3-4 mm, $D_{50}$ are $54.98-61.19{\mu}m$(D3L15, D4L15), fraction of bubble less than $50{\mu}m$ are 0.326, 0.345. And it is superior to others. Besides, $D_{50}$ and fraction of bubble less than $50{\mu}m$ of throat length 20 mm are $49.40-54.98{\mu}m$, 0.447, respectively And nozzle that throat length 20 mm is relatively tendency to generate microbubble stably.

A Numerical Study on Smoke Behavior of Fishing Vessel Engine Room (어선 기관실의 연기 거동에 관한 수치해석 연구)

  • JANG, Ho-Sung;JI, Sang-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.683-690
    • /
    • 2021
  • The ventilation system of the engine room of a ship is generally installed to supply the combustion air necessary for the internal combustion engine and to remove the heat source generated in the engine room, and it must satisfy the international standard (ISO 8861) for the design conditions and calculation standards for the ventilation of the ship engine room. The response delay of the ventilation system including the fire detector is affected by the airflow formed inside the area and the location of the fire detector. In this study, to improve the initial fire detection response speed of a fire detector installed on a fishing vessel and to maintain the sensitivity of the installed detector, the smoke behavior was simulated using the air flow field inside the engine room, the amount of combustion air in the internal combustion engine, and the internal pressure of the engine room as variables. Analysis of the simulation results showed that reducing the flow rate in the air flow field and increasing the vortex by reducing the internal pressure of the engine room and installing a smoke curtain would accelerate the rise of the ceiling of the smoke component and improve the smoke detector response speed and ventilation system.

A Study on SOx Emission Characteristics in Coal Combustion (석탄 연소시 SOx 배출 특성에 관한 연구)

  • Kang, Youn Suk;Kim, Sung Su;Lee, Hyun Dong;Kim, Jae-Kwan;Hong, Sung Chang
    • Applied Chemistry for Engineering
    • /
    • v.22 no.2
    • /
    • pp.219-223
    • /
    • 2011
  • The characteristics of SOx emission were investigated using SM (India) coal and Berau, C&A (Austria) coal. Experiments were performed in two different ways. In the first type of experiment, the temperature in the furnace was increased and the, samples were combusted at the ignition temperature after filling the furnace with coal. The second experimental method was to add the coal to after maintaining a constant temperature. The results demonstrated that SOx emission from coal combustion depended upon the sulfur content. In the case of Berau coal and C&A coal, an enhancement of combustibility which was accomplished by increasing the combustion temperature, an increase in airflow and decrease in particle size of coals tended to increase $SO_2$ generation. Conversely, in the case of SM coal, the concentration of $SO_2$ tended to decrease, because the high contents of $Fe_2O_3$ in the ashes increased the oxidation power of coal itself, which oxidized $SO_2$ into $SO_3$. In the case of C&A coal, the $SO_2$ peak was only observed twice. This was thought to be caused by the thermal transfer rate from the surface to the interior of the coal.

Improvement in flow and noise performance of backward centrifugal fan by redesigning airfoil geometry (익형 형상 재설계를 통한 후향익 원심팬의 유동 및 소음성능 개선)

  • Jung, Minseung;Choi, Jinho;Ryu, Seo-Yoon;Cheong, Cheolung;Kim, Tae-hoon;Koo, Junhyo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.555-565
    • /
    • 2021
  • The goal of this study is to improve flow and noise performances of existing backward-curved blade centrifugal fan system used for circulating cold air in a refrigerator freezer by optimally designing airfoil shape. The unique characteristics of the system is to drive cold airflow with two volute tongues in combination with duct system in a back side of a refrigerator without scroll housing generally used in a typical centrifugal fan system. First, flow and noise performances of existing fan system were evaluated experimentally. A P-Q curve was obtained using a fan performance tester in the flow experiment, and noise spectrum was measured in an anechoic chamber in the noise experiment. Then, flow characteristics were numerically analyzed by solving the three-dimensional unsteady Navier-Stokes equations and noise analysis was performed by solving the Ffowcs Williams and Hawkins equation with input from the flow simulation results. The validity of numerical results was confirmed by comparing them with the measured ones. Based on the verified numerical method, blade inlet and outlet angles were optimized for maximum flow rate using the two-factor central composite design of the response surface method. Finally, the flow and noise performances of a prototype manufactured with the optimum design were experimentally evaluated, which showed the improvement in flow and noise performance.

Deep Learning-based Object Detection of Panels Door Open in Underground Utility Tunnel (딥러닝 기반 지하공동구 제어반 문열림 인식)

  • Gyunghwan Kim;Jieun Kim;Woosug Jung
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.665-672
    • /
    • 2023
  • Purpose: Underground utility tunnel is facility that is jointly house infrastructure such as electricity, water and gas in city, causing condensation problems due to lack of airflow. This paper aims to prevent electricity leakage fires caused by condensation by detecting whether the control panel door in the underground utility tunnel is open using a deep learning model. Method: YOLO, a deep learning object recognition model, is trained to recognize the opening and closing of the control panel door using video data taken by a robot patrolling the underground utility tunnel. To improve the recognition rate, image augmentation is used. Result: Among the image enhancement techniques, we compared the performance of the YOLO model trained using mosaic with that of the YOLO model without mosaic, and found that the mosaic technique performed better. The mAP for all classes were 0.994, which is high evaluation result. Conclusion: It was able to detect the control panel even when there were lights off or other objects in the underground cavity. This allows you to effectively manage the underground utility tunnel and prevent disasters.

Evaluation of Ventilation Performances for Various Combinations of Inlets and Outlets in a Residential Unit through CO2 Tracer-Gas Concentration Decay Method (CO2 추적가스 농도감소법을 이용한 공동주택의 급·배기구 조합에 따른 환기 성능 분석)

  • Sang Yoon Lee;Soo Man Lee;Jong Yeob Kim;Gil Tae Kim;Byung Chang Kwag
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.111-120
    • /
    • 2023
  • Indoor air quality has become increasingly important with the increase in time spent in residential environments, impact of external fine dust, yellow dust, and the post-COVID 19 pandemic. Residential mechanical ventilation plays a key role in addressing indoor air quality. The legal standard for residential air changes per hour in Korea is 0.5 ACH. However, there are no standards for the location of supply and return vents. This study atempts to analyze the impact of ventilation performance based on the location of supply and return vents. An experiment was conducted using the CO2 tracer gas concentration decay method in a mock-up house set inside a large chamber to minimize external influences. The experimental results indicated that the commonly used combination of 2 supply and 2 return vents in living room spaces had a lower mean age of air than the combination of 1 supply and 2 return vents. Using multiple supply and return vents had lower mean age of air than using just 1 supply and 1 return vent.

The Patterns of Change in Arterial Oxygen Saturation and Heart Rate and Their Related Factors during Voluntary Breath holding and Rebreathing (자발적 호흡정지 및 재개시 동맥혈 산소포화도와 심박수의 변동양상과 이에 영향을 미치는 인자)

  • Lim, Chae-Man;Kim, Woo-Sung;Choi, Kang-Hyun;Koh, Youn-Suck;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.379-388
    • /
    • 1994
  • Background : In sleep apnea syndrome, arterial oxygen saturation($SaO_2$) decreases at a variable rate and to a variable degree for a given apneic period from patient to patient, and various kinds of cardiac arrythmia are known to occur. Factors supposed to affect arterial oxygen desaturation during apnea are duration of apnea, lung voulume at which apnea occurs, and oxygen consumption rate of the subject. The lung serves as preferential oxygen source during apnea, and there have been many reports related with the influence of lung volume on $SaO_2$ during apnea, but there are few, if any, studies about the influence of oxygen consumption rate of an individual on $SaO_2$ during breath holding or about the profile of arterial oxygen resaturation after breathing resumed. Methods : To investigate the changes of $SaO_2$ and heart rate(HR) during breath holding(BH) and rebreathing(RB) and to evaluate the physiologic factors responsible for the changes, lung volume measurements, and arterial blood gas analyses were performed in 17 healthy subjects. Nasal airflow by thermistor, $SaO_2$ by pulse oxymeter and ECG tracing were recorded on Polygraph(TA 4000, Gould, U.S.A.) during voluntary BH & RB at total lung capacity(TLC), at functional residual capacity(FRC) and at residual volume(RV), respectively, for the study subjects. Each subject's basal metabolic rate(BMR) was assumed on Harris-Benedict equation. Results: The time needed for $SaO_2$ to drop 2% from the basal level during breath holding(T2%) were $70.1{\pm}14.2$ sec(mean${\pm}$standard deviation) at TLC, $44.0{\pm}11.6$ sec at FRC, and $33.2{\pm}11.1$ sec at RV(TLC vs. FRC, p<0.05; FRC vs. RV, p<0.05). On rebreathing after $SaO_2$ decreased 2%, further decrement in $SaO_2$ was observed and it was significantly greater at RV($4.3{\pm}2.1%$) than at TLC($1.4{\pm}1.0%$)(p<0.05) or at FRC($1.9{\pm}1.4%$)(p<0.05). The time required for $SaO_2$ to return to the basal level after RB(Tr) at TLC was not significantly different from those at FRC or at RV. T2% had no significant correlation either with lung volumes or with BMR respectively. On the other hand, T2% had significant correlation with TLC/BMR(r=0.693, p<0.01) and FRC/BMR (r=0.615, p<0.025) but not with RV/BMR(r=0.227, p>0.05). The differences between maximal and minimal HR(${\Delta}HR$) during the BH-RB manuever were $27.5{\pm}9.2/min$ at TLC, $26.4{\pm}14.0/min$ at RV, and $19.1{\pm}6.0/min$ at FRC which was significantly smaller than those at TLC(p<0.05) or at RV(p<0.05). The mean difference of 5 p-p intervals before and after RB were $0.8{\pm}0.10$ sec and $0.72{\pm}0.09$ sec at TLC(p<0.001), $0.82{\pm}0.11$ sec and $0.73{\pm}0.09$ sec at FRC(p<0.025), and $0.77{\pm}0.09$ sec and $0.72{\pm}0.09$ sec at RV(p<0.05). Conclusion Healthy subjects showed arterial desaturation of various rates and extent during breath holding at different lung volumes. When breath held at lung volume greater than FRC, the rate of arterial desaturation significantly correlated with lung volume/basal metabolic rate, but when breath held at RV, the rate of arterial desaturation did not correlate linearly with RV/BMR. Sinus arrythmias occurred during breath holding and rebreathing manuever irrespective of the size of the lung volume at which breath holding started, and the amount of change was smallest when breath held at FRC and the change in vagal tone induced by alteration in respiratory movement might be the major responsible factor for the sinus arrythmia.

  • PDF