• Title/Summary/Keyword: Airflow model

Search Result 195, Processing Time 0.026 seconds

A Study on Flow Characteristics of the Inlet Shape for the S-Duct (S-Duct 입구 형상에 따른 유동 특성에 관한 연구)

  • Lee, Jihyeong;Choi, Hyunmin;Ryu, Minhyoung;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.2
    • /
    • pp.109-117
    • /
    • 2015
  • Aircraft needs an inlet duct to supply the airflow to engine face. A fighter aircraft that requires low radar observability has to hide the engine face in the fuselage to reduce the Radar Cross Section(RCS). Therefore, the flow path of the inlet duct is changed into S-shape. The performance of the aircraft engine is known to be influenced by the shape and the centerline curvature of the S-Duct. In this study, CFD analysis of the RAE M 2129 S-Duct has been performed to investigate the influence of aspect ratio of inlet geometry. The performance of the S-Duct is evaluated in terms of the distortion coefficient. To simulate the flow under adverse pressure gradient better, $k-{\omega}SST$ turbulence model is employed. The computational results are validated with the ARA experimental data. The secondary flow and the flow separation are observed for all computational cases, while the semi-circular geometry has been found to produce the best results.

The Change of Cell Distribution in the lung and the Expression Pattern of IL-4 and IL-10 in Asthma Induced Mouse (천식유발 마우스에서의 폐 내 세포조성 변화와 IL-4 및 IL-10의 발현 양상)

  • Lee, Soo-Jin;Park, Se-Jong;Li, Tian-Zhu;Jang, Yang-Ho;Choe, Nong-Hoon
    • Journal of Life Science
    • /
    • v.16 no.5
    • /
    • pp.780-787
    • /
    • 2006
  • Asthma is a chronic inflammatory disorder of the airways, which characterized by bronchial hyperresponsiveness, reversible airflow limitation and respiratory symptoms. Internationally, the prevalence of asthma has been increased over last 3 decades. Recently, several studies of asthma have been reported with gradually increasing importance. To tesify the hypothesis that interleukin (IL)-4 and IL-10 may be an important determinant of the severity of airway inflammation, their expression was studied in mouse model of asthma. BALB/c mouse, IL-4 Knockout (KO) mouse and IL-10 KO mouse were sensitized with intraperitoneal injection of ovalbumin adsorbed to aluminum potassium sulfate, followed by challenges with intranasal ovalbumin on 3 consecutive days. The severity of pulmonary inflammation was assessed by eosinophilia in BAL fluid, number of total BAL cells, histopathological changes in lung tissues, and immunohistochemical staining against IL-4 and IL-10. In BAL fluid, the number of total cells was significantly increased in asthma induced mouse compare to the control. In asthma induced mouse, eosinophil was increased to 56% and neutrophil was 0.2%. In H &E stains, eosinophilic infiltration and epithelium hyperplasia were clearly noticed in asthma induced mouse. In immunohistochemical staining for IL-4 and IL-10, there was no positive reaction in control group. However, very strong reactions were appeared in asthma induced group. In this research, IL-4 and IL-10, which seem to play a central role in allergic asthma, KO mouse was utilized to test the causative relationship between airway inflammation and role of specific cytokine. Asthma induced IL-4 and IL-10 KO mice showed much decreased inflammatory reactions in the number of total BAL cells, in eosinophilic infiltration, and in immunohistochemical stains against diverse inflammatory proteins. These results suggest that IL-4 and IL-10 increase the asthmatic reactions in vivo mice model.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

The Effect of Dexamethasone on Airway Goblet Cell Hyperplasia and Inflammation in $TiO_2$-Treated Sprague-Dawley Rats ($TiO_2$로 처치된 백서에서 기도내 배상세포 증식과 염증에 대한 Dexamethasone의 효과)

  • Lim, Gune-Il;Kim, Do-Jin;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.1
    • /
    • pp.37-48
    • /
    • 2000
  • Backgrounds : The pathophysiology of chronic airflow obstruction, such as bronchial asthma, is characterized by mucus hypersecretion, goblet cell hyperplasia(GCH), smooth muscle hypertrophy, and inflammatory cells infiltration. In fatal asthma patients, one distinct findings is mucus hypersecretion due to GCH. However, the mechanisms of GCH in these hypersecretory diseases remain still unknown. In this study, a rat model was rapidly induced with GCH by instillation of $TiO_2$, intratracheally. We intend to confirm GCH and association of concomitant inflammatory cells infiltration and to observe the effect of potent antiinflammatory agent, that is dexamethasone, on GCH with inflammatory cells. Methods : Twenty-one 8-weeks-old male Sprague-Dawley rats were divided into three groups. Endotoxinfree water was instilled intratracheally in group 1(control) ; $TiO_2$, was instilled in the group 2 ; and dexamethasone was injected intraperitoneally to group 3 before $TiO_2$ instillation. After 120 hours, all rats were sacrificed, and trachea, bronchi, and lungs were resected respectively. These tissues were made as paraffin blocks and stained as PAS for goblet cells and Luna stain for eosinophils. We calculated the ratio of goblet cell to respiratory epithelium and number of infiltrated eosinophils from each tissue. Results : (1) Fraction of goblet cells was significantly increased in group 2 than in group 1 in the trachea and in the main bronchus. (10.19$\pm$11.33% vs 4.09$\pm$8.28%, p<0.01 and 34.09$\pm$23.91% vs 3.61$\pm$4.84%, p<0.01, respectively). (2) Eosinophils were significantly increased in the airway of group 2 than that of group 1. (5.43$\pm$3.84% vs 0.17$\pm$0.47 in trachea and 47.71$\pm$16.91 vs 2.71$\pm$1.96 in main bronchi). (3) There was a positive correlation between goblet cells and eosinophils(r=0.719, p=0.001). (4) There was significant difference in the decrease of goblet cells after dexamethasone injection between group 2 and group 3 (p<0.01). Also, infiltration of eosinophils was suppressed by dexamethasone. Conclusion : We made an animal model of $TiO_2$-induced goblet cell hyperplasia. GCH was observed mainly in the main bronchi with concomitant eosinophilic infiltration. Both goblet cell hyperplasia and eosinophilic infiltration were suppressed by dexamethasone. This animal model may serve as a useful tool in understanding of the mechanism of GCH in chronic airway diseases.

  • PDF

Detection of Pathogenic Viruses in the Atmosphere during Asian Dust Events in Incheon City (인천지역에서 황사 기간 동안 대기 중의 바이러스 검출에 관한 연구)

  • Park, Jeong Woong;Lim, Young Hee;Kyung, Sun Young;An, Chang Hyeok;Lee, Sang Pyo;Jeong, Seong Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.3
    • /
    • pp.279-285
    • /
    • 2005
  • Background : Ambient particles during Asian dust events are usually less than $10{\mu}m$ in size, and known to be associated with the adverse effects on the general population. There is little evidence linking Asian dust to adverse effects on the airways. In 2002, the authors found that particulate matter during Asian dust events had an effect on the symptoms and pulmonary function of patients with bronchial asthma. An aggravating factor might be that of a viral infection, but this remains unclear. Conversely, it has been speculated that African dust may carry the virus responsible for foot and mouth disease. Asian dust events are also likely to be responsible for transporting viruses, some of which are pathogenic, and common in many environments. Therefore, in this study, air samples were screened for the presence of viruses. Methods : Air samples were collected 20 times each during Asian dust events and under non-dust conditions, for at least 6 hours per sample, using a high volume air sampler (Sibata Model HV500F), with an airflow rate of 500L/min, between April and August 2003, and between April and August 2004. The samples were then screened for the presence of targeted viruses (Influenza A, B, Hog cholera virus, and Aphthovirus) using a polymerase chain reaction method. Results : One Asian dust event occurred between April and August 2003, and 3 between April and August 2004, with a 24 hour average PM10 level of $148.0{\mu}g/m^3$. The 24 hour average PM10 level was $57{\mu}g/m^3$. There was a significant difference in the PM10 concentration between dusty and clear days. No viruses (Influenza virus, Aphthovirus, and Hog cholera virus) were identified in the air samples obtained during the dusty days. Conclusions : Although no virus was detected in this study, further studies will be needed to identify suspected viruses carried during Asian dust events, employing more appropriate virus detection conditions.