• 제목/요약/키워드: Airflow model

검색결과 195건 처리시간 0.035초

Ammonia Removal Model Based on the Equilibrium and Mass Transfer Principles

  • Yoon, Hyein;Lim, Ji-Hye;Chung, Hyung-Keun
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권3호
    • /
    • pp.555-561
    • /
    • 2008
  • In air stripping of ammonia from the aqueous solution, a new removal model was presented considering the equilibrium principles for the ammonia in aqueous solution and between the aqueous and air phase. The effects of pH, temperature and airflow rate on the ammonia removal were evaluated with the model. In addition, the saturation degree of ammonia in air was defined and used to evaluate the effect of each experimental factor on the removal rate. As pH (8.9 to 11.9) or temperature (20 to 50 oC) was increased, the overall removal rate constants in all cases were appeared to be increased. Our presented model shows that the degrees of saturation were about the same (0.45) in all cases when the airflow condition remains the same. This result indicates that the effect of pH and temperature were directly taken into consideration in the model equation. As the airflow increases, the overall removal rate constants were increased in all cases as expected. However, the saturation degree was exponentially decreased with increasing the airflow rate in the air phase (or above-surface) aeration. In the subsurface aeration the saturation degree remains a constant value of 0.65 even though the airflow rate was increased. These results indicate that the degree of saturation is affected mainly by the turbulence of the aqueous solution and remains the same above a certain airflow rate.

빌딩 내의 공기유동량 예측을 위한 누입 및 환기모델의 개발 (Development of an Infiltration and Ventilation Model for Predicting Airflow Rates within Buildings)

  • 조석호
    • 한국환경과학회지
    • /
    • 제23권2호
    • /
    • pp.207-218
    • /
    • 2014
  • A ventilation model was developed for predicting the air change per hour(ACH) in buildings and the airflow rates between zones of a multi-room building. In this model, the important parameters used in the calculation of airflow are wind velocity, wind direction, terrain effect, shielding effect by surrounding buildings, the effect of the window type and insect screening, etc. Also, the resulting set of mass balance equations required for the process of calculation of airflow rates are solved using a Conte-De Boor method. When this model was applied to the building which had been tested by Chandra et al.(1983), the comparison of predicted results by this study with measured results by Chandra et al. indicated that their variations were within -10%~+12%. Also, this model was applied to a building with five zones. As a result, when the wind velocity and direction did not change, terrain characteristics influenced the largest and window types influenced the least on building ventilation among terrain characteristics, local shieldings, and window types. Except for easterly and westerly winds, the ACH increased depending on wind velocity. The wind direction had influence on the airflow rates and directions through openings in building. Thus, this model can be available for predicting the airflow rates within buildings, and the results of this study can be useful for the quantification of airflow that is essential to the research of indoor air quality(temperature, humidity, or contaminant concentration) as well as to the design of building with high energy efficiency.

벼의 저온건조 시뮬레이션 (Low Temperature Drying Simulation of Rough Rice)

  • 김훈;한재웅
    • Journal of Biosystems Engineering
    • /
    • 제34권5호
    • /
    • pp.351-357
    • /
    • 2009
  • This study was conducted to verify the simulation model through the drying test, and investigate effect of factors, such as temperature of drying air, airflow rate, and velocity of the airflow, on the drying. The low temperature drying simulation model was developed based on the circulation dry simulation model presented by Keum et al. (1987), and by modifying low temperature thin layer drying model, equilibrium moisture content model, latent heat of vaporization model, and crack ratio prediction model. The heat pump and experimental dryer with a capacity of 150kg were used for the test. The RMSE between the predicted and measured value was 0.27% (drying temperature), 0.15% (crack ratio), and 2.08% (relative humidity), so the relevance of the model was verified. In addition, the effect of drying temperature, airflow rate, and velocity of the airflow on the drying was examined. The experimental results showed that the crack ratio at drying temperature of $25{\sim}40^{\circ}C$ was allowable. Moreover, at below $30^{\circ}C$, variation of the crack ratio was slight, but drying time was delayed. Given these results, the drying temperature of over $30^{\circ}C$ was effective. As the airflow rate increased, required energy dramatically increased. Whereas drying rate slowly increased, so loss of drying efficiency was caused. Considering these results, the dryer needed to be designed and adjusted to lower than $30\;m^3/min{\cdot}ton$. As velocity of the airflow increased, required drying energy increased when the velocity of the airflow was over $5\;m^3$/hr, while crack ratio and drying rate showed little variation.

Analysis of Supply Airflow Control by a Stratified Thermal Model in a VAV System

  • Kim, Seo-Young;Moon, Jeong-Woo;Cho, Hyung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.46-56
    • /
    • 2001
  • The present study concerns the numerical simulation of a supply airflow control in a variable air volume (VAY) system. A stratified thermal model (multi-zone model) is suggested to predict a local thermal response of an air-conditioned space. The effects of various thermal parameters such as the cooling system capacity, the thermal mass of an air-conditioned space, the time delay of thermal effect, and the building envelope heat transmission are investigated. Further, the influence of control parameters such as the supply air temperature, the PI control factor and the thermostat location on a VAV system is quantitatively delineated. The results obtained show that the previous homogeneous lumped thermal model (single zone model) may overestimate the time taken to the set point temperature. It is also found that there exist the appropriate ranges of the control parameters for the optimal airflow control of the VAV system.

  • PDF

열교환기 휜에서의 착상 거동 (Behavior of frost formed on heat exchanger fins)

  • 김정수;이관수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2334-2339
    • /
    • 2008
  • This paper proposes an improved mathematical model for predicting the frosting behavior on a two-dimensional fin considering the heat conduction of heat exchanger fins under frosting conditions. The model consists of laminar flow equation in airflow, diffusion equation of water vapor for frost layer, and heat conduction equation in fin, and these are coupled together. In this model, the change in three-dimensional airside airflow caused by frost growth is accounted for. The fin surface temperature increased toward the fin tip due to the fin heat conduction. On the contrary, the temperature gradient in the airflow direction(x-dir.) is small throughout the entire fin. The frost thickness in the direction perpendicular to airflow, i.e. z-dir., decreases exponentially toward the fin tip due to non-uniform temperature distribution. The rate of decrease of heat transfer in the airflow direction is high compared to that in the z-direction due to more decrease in the sensible and latent heat rate in x-direction.

  • PDF

식물공장 기류해석을 위한 디지털트윈 개발 및 실증 (Development and Validation of Digital Twin for Analysis of Plant Factory Airflow)

  • 정진립;원보영;유호동;김탁곤;강대현;홍경진
    • 한국시뮬레이션학회논문지
    • /
    • 제31권1호
    • /
    • pp.29-41
    • /
    • 2022
  • 이상기후로 인한 불안정한 식량 수급을 해결하기 위한 대안 중 하나로 식물공장의 필요성이 증대되고 있다. 식물공장 내 기류는 재배작물의 증산작용과 열교환에 중요한 인자 중 하나로 인식되고 있다. 한편, 디지털트윈(Digital Twin: DT)은 실체계를 가상세계에 복제한 것으로 실체계만으로 불가능한 다양한 서비스를 제공하는 수단으로 주목받고 있다. 본 연구에서는 디지털트윈 개념을 실제 운용중인 식물공장 기류해석에 적용하여 다양한 상황에 기류를 예측할 수 있는 기류 예측 DT 모델 개발을 목표로 하였다. 이를 위해 먼저 기류 해석용 디지털트윈 수학적 형식론을 제시하고, 이를 기반으로 실제 운용중인 식물공장의 기류예측 모델링에 필요한 정보들을 명세한다. 이어서 식물공장 내 형상을 CAD로 구현하고 유동해석을 위한 전산유체역학(CFD) 구성요소들을 결합하여 DT 모델을 개발하였다. 마지막으로 DT 모델의 시뮬레이션 해석 결과를 식물공장에서 수집한 실제 기류값과 비교하는 모델의 실증 및 기계학습 기반 보정을 통해 정확도가 높은 기류 예측용 DT 모델을 완성하였다.

대기 안정도와 지표면 온도가 미세규모 국지 흐름에 미치는 영향: 수문지역을 대상으로 (Effects of Atmospheric Stability and Surface Temperature on Microscale Local Airflow in a Hydrological Suburban Area)

  • 박수진;김도용;김재진
    • 대기
    • /
    • 제23권1호
    • /
    • pp.13-21
    • /
    • 2013
  • In this study, the effects of atmospheric stability and surface temperature on the microscale local airflow are investigated in a hydrological suburban area using a computational fluid dynamics (CFD) model. The model domain includes the river and industrial complex for analyzing the effect of water system and topography on local airflow. The surface boundary condition is constructed using a geographic information system (GIS) data in order to more accurately build topography and buildings. In the control experiment, it is shown that the topography and buildings mainly determine the microscale airflow (wind speed and wind direction). The sensitivity experiments of atmospheric stability (neutral, stable, and unstable conditions) represent the slight changes in wind speed with the increase in vertical temperature gradient. The differential heating of ground and water surfaces influences on the local meteorological factors such as air temperature, heat flow, and airflow. These results consequentially suggest that the meteorological impact assessment is accompanied by the changes of background land and atmospheric conditions. It is also demonstrated that the numerical experiments with very high spatial resolution can be useful for understanding microscale local meteorology.

벼 상온통풍건조의 최소풍량비에 관한 연구 (Minimum Specific Airflow Rate Requirements for Natural Air Drying of Rough Rice in Korea)

  • 금동혁;박선태
    • Journal of Biosystems Engineering
    • /
    • 제21권1호
    • /
    • pp.60-71
    • /
    • 1996
  • The purposes of this study were to develop a simulation model and to determine minimum specific airflow rate requirements for natural air drying of rough rice in Korea. A simulation model was developed considering energy and mass balances within grain bed, drying and rewetting rates, and hysterisis effect between sorption and desorption isotherms. As the results of validation test, the moisture contents predicted by the model agreed very well with the actual data. The criteria for determining minimum specific airflow rate requirements was that the top loom layer in the bin be dried to a moisture content below 16 percent wet basis with less than 0.5% drymatter decomposition. The minimum specific airflow rate requirements in 13 locations of Korea were presented based on the worst one among the past 7 to 13-year weather data. These requirements were also presented for all the combinations of three harvest dates and four harvest moisture contents. Specific airflow rate requirements seemed to be half by each 2 percent reduction in moisture content from 24 percent. As harvest date was delayed by 10 days from October 1, these requirements were reduced by about 20 to 40 percent.

  • PDF

자동차 디퓨저의 형상에 따른 공기흐름의 해석 (Analysis of Airflow due to the Configuration of Automotive Diffuser)

  • 최계광;조재웅
    • 한국기계가공학회지
    • /
    • 제19권11호
    • /
    • pp.16-22
    • /
    • 2020
  • This study was aimed at analyzing the velocity and pressure changes in the airflow corresponding to different configurations of a diffuser for three types of cars. According to the flow results of the three automotive models, in model 3, the vortex was formed slightly upward on the outlet plane, whereas in models 1 and 2, the vortex was generated lower than that in model 3. The values of the pressure distribution in model 3 were larger than those for models 1 and 2 on the planes located at the same distance from the end of the rear part. The maximum turbulent kinetic energies in models 1 and 2 occurred at a location lower than that in model 3. The shape corresponding to the airflow that enhanced the driving performance was determined through the flow analysis.

공기식 집열창 시스템이 설치된 건물의 동적부하 해석 (Time Dependent Thermal Load Analysis of the Building with an Airflow Window System)

  • 조성환;박상동
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.82-95
    • /
    • 1992
  • It has been known that the application of an airflow window system reduces the energy consumption compared with conventional double pane window in a building. But how to analyze thermal load in a building with an airflow window system has not been well known. so two kinds of method (Mode 1 and Mode 2) to analyze time dependent thermal load of the building with an airflow window system are presented in this study. The results of load analysis about the model building(total area : $4521m^2$, 3 floors) by Mode 2 show that the maximum cooling and heating load in a building with an airflow window system are decreased about 12-17% and about 19.5% than with double pane glass window, and yearly energy consumption with an airflow window system is saved about about 20% than with double pane glass window.

  • PDF