• Title/Summary/Keyword: Airflow limitation

Search Result 51, Processing Time 0.027 seconds

Association of Airflow Limitation and COPD Composite Index with Peripheral Oxygen Saturation in Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환자에서 기류제한 및 COPD 복합지수와 말초산소포화도의 연관성)

  • Jong Seong Lee;Jae Hoon Shin;Jin Ee Baek;Hyerim Son;Byung-soon Choi
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.57-66
    • /
    • 2024
  • Objective: Chronic obstructive pulmonary disease (COPD) is characterized by progressive airflow obstruction that is only partly reversible, inflammation in the airways, and systemic effects. This study aimed to investigate the association between low peripheral oxygen saturation levels (SpO2), and composite indices predicting death in male patients with (COPD). Method: A total of 140 participants with post-bronchodilator FEV1/FVC ratio less than 0.7 were included. Three composite indices (ADO, DOSE, BODEx) were calculated using six variables such as age (A), airflow obstruction (O), body mass index (B), dyspnea (D), exacerbation history (E or Ex), and smoking status (S). Severity of airflow limitation was classified according to Global Initiative for Obstructive Lung Disease (GOLD) guidelines. SpO2 was measured by pulse oximetry, and anemia and iron deficiency were assessed based on blood hemoglobin levels and serum markers such as ferritin, transferrin saturation, or soluble transferrin receptor. Results: Participants with low SpO2 (<95%) showed significantly lower levels of %FEV1 predicted (p=0.020) and %FEV1/FVC ratio (p=0.002) compared to those with normal SpO2 levels. The mMRC dyspnea scale (p<0.001) and GOLD grade (p=0.002) showed a significant increase in the low SpO2 group. Receiver Operating Characteristic analysis revealed higher area under the curve for %FEV1 (p=0.020), %FEV1/FVC(p=0.002), mMRC dyspnea scale (p=0.001), GOLD grade (p=0.010), ADO (p=0.004), DOSE (p=0.002), and BODEx (p=0.011) in the low SpO2 group. Conclusion: These results suggest that low SpO2 levels are related to increased airflow limitation and the composite indices of COPD.

Prevalence of Combined Bronchial Asthma with COPD in Patients with Moderate to Severe Air flow Limitation (중등증 및 중증의 만성 기류 장애 환자에서 만성폐쇄성폐질환과 기관지 천식의 합병률)

  • Rhee, Yang Keun;In, Byeong Hyun;Lee, Yang Deok;Lee, Yong Chul;Lee, Heung Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.4
    • /
    • pp.386-394
    • /
    • 2003
  • Background : ATS(American Thoracic Society) defined new guidelines for COPD(chronic obstructive lung disease) in April 2001, following the results of the global initiative for chronic obstructive lung disease. The most important concept of COPD is an airflow limitation which is not fully reversible compared to bronchial asthma(BA). The criteria for COPD are postbronchodilator $FEV_1$ less than 80% of the predicted value and an $FEV_1$ per FVC ratio less than 70%. The global initiative for asthma(GINA) study defined asthma, which included immune-mediated chronic airway inflammatory airway disease, and found that airflow limitation was wide spread, variable and often completely reversible. Taken together COPD and BA may be combined in airflow limitation. This study was designed to evaluate the prevalence of BA in patients with COPD of moderate to severe airflow limitation. Methods : COPD was diagnosed by symptoms and spirometry according to ATS guidelines. Enrolled subjects were examined for peak flow meters(PFM), sputum eosinophils and eosinophil cationic protein(ECP) levels, serum total IgE with allergy skin prick test, and methacholine bronchial provocation test(MBPT). Results : About 27% of COPD patients with moderate to severe airflow limitation were combined with BA. There was significantly decreased response to PFM in severe COPD. However, there was no significant relationship between BA and COPD according to the degree of severity. The BA combined with COPD group showed significantly high eosinophil counts and ECP level in induced sputum. However, neutrophil counts in induced sputum showed significant elevation in the pure COPD group. Conclusion : Twenty-seven percent of COPD patients with moderate to severe ventilation disorder were combined with BA, but there were no significant differences according to the degree of severity.

Nutritional Management in Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 환자의 영양관리)

  • Lee, Kwan-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.2
    • /
    • pp.133-142
    • /
    • 2004
  • Chronic obstructive pulmonary disease(COPD) is characterized by a not entirely reversible limitation in the airflow. An airflow limitation is progressive and associated with an abnormal inflammatory response of the lung to gases and harmful particles. In COPD, the weight loss is commonly observed and there is a negative impact on the respiratory as well as skeletal muscle function. The pathophysiological mechanisms that result in weight loss in COPD are not fully understood. However, the mechanisms of weight loss in COPD may be the result of an increased energy expenditure unbalanced by an adequate dietary intake. The commonly occurring weight loss and muscle wasting in COPD patients adversely affect the respiratory and peripheral muscle function, the exercise capacity, the health status, and even the survival rates. Therefore, it is very valuable to include management strategies that the increase energy balance in order to increase the weight and fat free mass. A Better understanding of the molecular and cellular pathological mechanisms of COPD can improve the many new directions for both the basic and clinical investigations. The Nutritional supply is an important components of a multidisciplinary pulmonary rehabilitation program. Future studies combining an exercise program, the role of anabolic steroids, nutritional individualization, a more targeted nutritional therapy, and the development of new drugs including anti-cytokines is needed for the effective management of COPD.

  • PDF

Numerical Analysis of Flow Uniformity in Selective Catalytic Reduction (SCR) Process Using Computational Fluid Dynamics (CFD)

  • Shon, Byung-Hyun
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.295-306
    • /
    • 2022
  • The NOx removal performance of the SCR process depends on various factors such as catalytic factors (catalyst composition, shape, space velocity, etc.), temperature and flow rate distribution of the exhaust gas. Among them, the uniformity of the flow flowing into the catalyst bed plays the most important role. In this study, the flow characteristics in the SCR reactor in the design stage were simulated using a three-dimensional numerical analysis technique to confirm the uniformity of the airflow. Due to the limitation of the installation space, the shape of the inlet duct was compared with the two types of inlet duct shape because there were many curved sections of the inlet duct and the duct size margin was not large. The effect of inlet duct shape, guide vane or mixer installation, and venturi shape change on SCR reactor internal flow, airflow uniformity, and space utilization rate of ammonia concentration were studied. It was found that the uniformity of the airflow reaching the catalyst layer was greatly improved when an inlet duct with a shape that could suppress drift was applied and guide vanes were installed in the curved part of the inlet duct to properly distribute the process gas. In addition, the space utilization rate was greatly improved when the duct at the rear of the nozzle was applied as a venturi type rather than a mixer for uniform distribution of ammonia gas.

Change of Lung Volumes in Chronic Obstructive Pulmonary Disease Patients with Improvement of Airflow Limitation after Treatment (치료 후 기류제한이 호전된 만성폐쇄성폐질환 환자에서 폐용적의 변화)

  • Park, Hun Pyo;Park, Soon Hyo;Lee, Sang Won;Seo, Yong Woo;Lee, Jeong Eun;Seo, Chang Kyun;Kwak, Jin Ho;Jeon, Young June;Lee, Mi Young;Chung, In Sung;Kim, Kyung Chan;Choi, Won-Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.2
    • /
    • pp.143-147
    • /
    • 2004
  • Background : It is important to predict the exercise capacity and dyspnea, as measurements of lung volume, in patients with COPD. However, lung volume changes in response to an improvement in airflow limitation have not been explored in detail. In the present study, it is hypothesized that lung volume responses might not be accurately predicted by flow responses in patients with moderate to severe airflow limitations. Methods : To evaluate lung volume responses, baseline and follow up, flow and lung volumes were measured in moderate to severe COPD patients. The flow response was defined by an improvement in the $FEV_1$ of more than 12.3%; lung volume changes were analyzed in 17 patients for the flow response. Results : The mean age of the subjects was 66 years; 76% were men. The mean baseline $FEV_1$, $FEV_1$/FVC and RV were 0.98L (44.2% predicted), 47.5% and 4.65 L (241.5%), respectively. The mean follow up duration was 80 days. The mean differences in the $FEV_1$, FVC, TLC and RV were 0.27 L, 0.39 L, -0.69 L and -1.04 L, respectively, during the follow up periods. There was no correlation between the delta $FEV_1$ and delta RV values(r=0.072, p=0.738). Conclusion : To appropriately evaluate the lung function in patients with moderate to severe airflow limitations; serial lung volume measurements would be helpful.

Effect of a New Spirometric Reference Equation on the Interpretation of Spirometric Patterns and Disease Severity (폐활량측정법의 새로운 정상예측식이 폐활량측정법 장애 양상 및 질병 중증도 해석에 미치는 영향)

  • Oh, Yeon-Mok;Hong, Sang-Bum;Shim, Tae Sun;Lim, Chae-Man;Koh, Younsuck;Kim, Woo Sung;Kim, Dong-Soon;Kim, Won Dong;Kim, Young Sam;Lee, Sang Do
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.2
    • /
    • pp.215-220
    • /
    • 2006
  • Background : A spirometric reference equation was recently developed for the general population in Korea. The applicability of the new Korean equation to clinical practice was examined by comparing it with the Morris equation, which is one of the most popular reference equations used for interpreting the spirometric patterns and for grading the disease severity in Korea. Methods : Spirometry was performed on 926 men and 694 women, aged 20 years or older, in November 2004 at the Asan Medical Center, Seoul, Korea. The subjects' age, gender, height, weight, and spirometric values ($FEV_1$ [forced expiratory volume in one second], FVC [forced vital capacity], and $FEV_1/FVC$) were obtained. The spirometric patterns and disease severity were evaluated using both equations, and the results of the Korean equation were compared with the Morris equation. The spirometric patterns were defined as normal, restrictive, obstructive, and undetermined according to the level of $FEV_1/FVC$ and FVC. The disease severity was defined according to the level of $FEV_1$ level for subjects with an airflow limitation, and according to the FVC level for those subjects without an airflow limitation. Results : Spirometric patterns were differently interpreted in 22.5% (208/926) of the men and 24.8% (172/694) of the women after the application of the Korean equation compared with the Morris equation. Of the subjects with airflow limitation, disease severity was differently graded in 30.2% (114/378) of the men and 39.4% (37/94) of the women after the application of the Korean equation. Of the subjects without airflow limitation, disease severity was differently graded in 27.9% (153/548) of the men and 30.2% (181/600) of the women after the application of the Korean equation. Conclusion : Achange in the reference equation for spirometry could have an effect on the interpretation of spirometric patterns and on the grading of disease severity.

Contributors of the Severity of Airflow Limitation in COPD Patients

  • Hong, Yoon-Ki;Chae, Eun-Jin;Seo, Joon-Beom;Lee, Ji-Hyun;Kim, Eun-Kyung;Lee, Young-Kyung;Kim, Tae-Hyung;Kim, Woo-Jin;Lee, Jin-Hwa;Lee, Sang-Min;Lee, Sang-Yeub;Lim, Seong-Yong;Shin, Tae-Rim;Yoon, Ho-Il;Sheen, Seung-Soo;Ra, Seung-Won;Lee, Jae-Seung;Huh, Jin-Won;Lee, Sang-Do;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • Background: Although airway obstruction in chronic obstructive pulmonary disease (COPD) is due to pathologic processes in both the airways and the lung parenchyma, the contribution of these processes, as well as other factors, have not yet been evaluated quantitatively. We therefore quantitatively evaluated the factors contributing to airflow limitation in patients with COPD. Methods: The 213 COPD patients were aged >45 years, had smoked >10 pack-years of cigarettes, and had a post-bronchodilator forced expiratory volume in one second ($FEV_1$)/forced vital capacity (FVC) <0.7. All patients were evaluated by medical interviews, physical examination, spirometry, bronchodilator reversibility tests, lung volume, and 6-minute walk tests. In addition, volumetric computed tomography (CT) was performed to evaluate airway wall thickness, emphysema severity, and mean lung density ratio at full expiration and inspiration. Multiple linear regression analysis was performed to identify the variables independently associated with $FEV_1$ - the index of the severity of airflow limitation. Results: Multiple linear regression analysis showed that CT measurements of mean lung density ratio (standardized coefficient ${\beta}$=-0.46; p<0.001), emphysema severity (volume fraction of the lung less than -950 HU at full inspiration; ${\beta}$=-0.24; p<0.001), and airway wall thickness (mean wall area %; ${\beta}$=-0.19, p=0.001), as well as current smoking status (${\beta}$=-0.14; p=0.009) were independent contributors to $FEV_1$. Conclusion: Mean lung density ratio, emphysema severity, and airway wall thickness evaluated by volumetric CT and smoking status could independently contribute to the severity of airflow limitation in patients with COPD.

The detection of collapsible airways contributing to airflow limitation (기류 제한에 영향을 미치는 허탈성 기도의 분석)

  • Kim, Yun Seong;Park, Byung Gyu;Lee, Kyong In;Son, Seok Man;Lee, Hyo Jin;Lee, Min Ki;Son, Choon Hee;Park, Soon Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.558-570
    • /
    • 1996
  • Background : The detection of Collapsible airways has important therapeutic implications in chronic airway disease and bronchial asthma. The distinction of a purely collapsible airways disease from that of asthma is important because the treatment of the dormer may include the use of pursed lip breathing or nasal positive pressure ventilation whereas in the latter, pharmacologic approaches are used. One form of irreversible airflow limitation is collapsible airways, which has been shown to be a Component of asthma or to emphysema, it can be assessed by the volume difference between what exits the lung as determined by a spirometer and the volume compressed as measured by the plethysmography. Method : To investigate whether volume difference between slow and forced vital Capacity(SVC-FVC) by spirometry may be used as a surrogate index of airway collapse, we examined pulmonary function parameters before and after bronchodilator agent inhalation by spirometry and body plethysmography in 20 cases of patients with evidence of airflow limitation(chronic obstructive pulmonary disease 12 cases, stable bronchial asthma 7 cases, combined chronic obstructive pulmonary disease with asthma 1 case) and 20 cases of normal subjects without evidence of airflow limitation referred to the Pusan National University Hospital pulmonary function laboratory from January 1995 to July 1995 prospectively. Results : 1) Average and standard deviation of age, height, weight of patients with airflow limitation was $58.3{\pm}7.24$(yr), $166{\pm}8.0$(cm), $59.0{\pm}9.9$(kg) and those of normal subjects was $56.3{\pm}12.47$(yr), $165.9{\pm}6.9$(cm), $64.4{\pm}10.4$(kg), respectively. The differences of physical characteristics of both group were not significant statistically and male to female ratio was 14:6 in both groups. 2) The difference between slow vital capacity and forced vital capacity was $395{\pm}317ml$ in patients group and $154{\pm}176ml$ in normal group and there was statistically significance between two groups(p<0.05). Sensitivity and specificity were most higher when the cut-off value was 208ml. 3) After bronchodilator inhalation, reversible airway obstructions were shown in 16 cases of patients group, 7 cases of control group(p<0.05) by spirometry or body plethysmography d the differences of slow vital capacity and forced vital capacity in bronchodilator response group and nonresponse group were $300.4{\pm}306ml$, $144.7{\pm}180ml$ and this difference was statistically significant. 4) The difference between slow vital capacity and forced vital capacity before bronchodilator inhalation was correlated with airway resistance before bronchodilator(r=0.307 p=0.05), and the difference between slow vital capacity and forced vital capacity after bronchodilator was correlated with difference between slow vital capacity and forced vital capacity(r=0.559 p=0.0002), thoracic gas volume(r=0.488 p=0.002) before bronchodilator and airway resistance(r=0.583 p=0.0001), thoracic gas volume(r=0.375 p=0.0170) after bronchodilator, respectively. 5) The difference between slow vital capacity and forced vital capacity in smokers and nonsmokers was $257.5{\pm}303ml$, $277.5{\pm}276ml$, respectively and this difference did not reach statistical significance(p>0.05). Conclusion : The difference between slow vital capacity and forced vital capacity by spirometry may be useful for the detection of collapsible airway and may help decision making of therapeutic plans.

  • PDF

Iron deficiency in Retired Workers exposed to Mineral dust with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환을 동반한 광물성분진 노출 이직근로자의 철 결핍)

  • Lee, Jong Seong;Shin, Jae Hoon;Baek, Jin Ee;Jeong, Ji Yeong;Kim, Hyeong Geun;Choi, Byung-Soon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.1
    • /
    • pp.42-49
    • /
    • 2019
  • Objective: Chronic obstructive pulmonary disease(COPD) is characterized by persistent airflow limitations associated with chronic inflammatory response due to noxious particles or gases in the lung. Iron deficiency is associated with chronic inflammation, such as COPD. The aim of this study was to evaluate the relationship among iron deficiency, iron homeostasis, and inflammation in retired miners with COPD. Methods: The serum levels of ferritin, soluble transferrin receptor(sTfR), and transferrin saturation(TSat) as biomarkers for iron deficiency and high-sensitivity C-reactive protein(hsCRP) as a biomarker for inflammation and hepcidin as a biomarker for iron homeostasis were measured in 93 male subjects. Iron deficiency was defined as any one or more of (1) sTfR>28.1 nmol/L, (2) TSat<16%, and (3) ferritin< $12{\mu}g/L$. Results: Iron deficiency was found 28% of the study subjects. Median levels of serum hsCRP was significantly increased related to airflow limitation of COPD(GOLD 1, $0.09{\mu}g/dL$ vs. GOLD 2, $0.17{\mu}g/dL$ vs. GOLD $3{\leq}$, $0.30{\mu}g/dL$, p=0.010), and was positively correlated with hepcidin(p=0.009). Mean level of serum hepcidin was lower in COPD subjects with iron deficiency(p=0.004) and serum levels of hepcidin was negatively correlated with %$FEV_1$ predicted(p=0.030). Conclusions: These results suggest that high serum levels of hepcidin are related to severe airflow limitation or inflammation and can decrease iron availability, regardless of iron status.

A Study on the Optimal Orifice Location for Air flow Measurement in an Air Duct Leakage Tester (덕트누기시험기용 풍량측정 오리피스의 최적위치 선정에 관한 연구)

  • Lee Seung-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.186-191
    • /
    • 2006
  • In this study, five experiments were carried out, with an orifice located downstream of a fan in case I where upstream duct length is 6 D, and that in the downstream is 4 D and different downstream distance to the fan in the rest, so as to determine the optimal location of the orifice and reduce the duct length of airflow measurement device. The resulting flow rate-pressure drop correlations were found to satisfy the limitation of SMACNA standard, which specified an error of $\pm7.5\%$ based on the real flow rate. Also, the best one of five. cases was achieved with the orifice located midway of the orifice duct four times its diameter long.