• Title/Summary/Keyword: Airflow Rate

Search Result 224, Processing Time 0.028 seconds

An Experimental Study On The Change Of Air Velocity With Respect To The Location And Size Of Regulators For Diagonal Ventilation System (Diagonal 환기 시스템에서 공기 조절기의 위치 및 크기에 따른 풍속 변화에 관한 실험적 연구)

  • Choi, Jong-Ak;Yoon, Chan-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.19 no.1
    • /
    • pp.11-18
    • /
    • 2009
  • Use of nuclear energy inevitably brings the problem of radioactive waste disposal. Repositories for disposing radioactive waste use underground space that is unconnected with the outside and the diagonal system, which allows the waste to be deposited. Ventilation if necessary because high-level radioactive waste generates heat. In this study, the air velocity through diagonal branches with regulators of different sizes and in different locations, was measured. The air velocity is determined by the size of the first and last regulators, regardless of the size of other regulators. In the diagonal system. Consequently, once the desired total airflow rate has been achieved by installing the appropriate first and last regulators, the other regulators fan be evenly installed to maintain the minimum air velocity needed.

Development of the Air Floating Conveyor System for the Large Glass Sheet (대평판 글라스 이송용 공기 부상 이송장치의 개발)

  • Lee, Tae Geol;Yu, Jin Sik;Jung, Hyo Jae;Kim, Jong-Hyeong;Kim, Joon Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.4
    • /
    • pp.635-642
    • /
    • 2013
  • We have prepared a DEMO conveyor device for conveying a large 8G class glass sheet using ahorizontal air-cushion system. This device consists of the body frame and the driving frame that are combined to realize a frame for conveying glass without any contact.The driving frame comprises an air flotation table (bed), drive roller supported at both ends, and ASU. Part of the ASU serves to control the airflow as the chamber consists of a porous pad and fan. Fiber filters replace the porous pad and axial fans serve as an air compressor. In addition, to determine the appropriate glass levitation from the air table, this study examined the design specifications of the applied filter (discharge speed of HEPA and ULPA filters, and flow rate) as well as the height of the and the proper supporting roller height (14mm). Then, after adjusting the position of the ASU and the number of ASUs required to configure the UNIT air floating C/V, we analyzed the height and flatness of the glass and derived the appropriate layout (1140-mm distance between ASUs).

Estimation of Air Flow Rate in Automotive Ventilated Seat (자동차 통풍 시트의 유량 평가)

  • Lee, Hyun-Hee;Kim, Tae-Kyung;Lee, Kwangju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.34-40
    • /
    • 2016
  • In ventilated seats for cars, air flow is generated by a fan and passed through a foam pad, foam filter, and seat cover. There is a significant loss of air flow in this process, and it is not easy to analyze the amount delivered to the driver. Another difficulty is the geometric complexity of the air flow passage inside the seats. In this paper, the air flow through a foam pad was analyzed. Proper modeling of the bumps in the ventilation mat was found to be important in the analysis. Air flow is lost when it passes through the porous pad foam, which was measured and used to correct the analysis results. The corrected analysis results were in a good agreement with the experimental results. The amount of air flow delivered to a driver was measured using an airflow cone. Only 35.7% of the air flow from the fan was delivered.

Study on Indoor Flow According to Vane Angle of Square Ceiling Type Louver Diffuser (사각 천장형 루버 디퓨저의 토출 각도에 따른 실내유동에 관한 연구)

  • Jang, Heon-Deock;Lee, Dae-Hui;Lee, Jin-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.683-687
    • /
    • 2012
  • The purpose of this paper is to numerically study the characteristics of the indoor air flow of a square ceiling type diffuser according to the vane angle and flow rate. The CFX of ANSYS 13.0 was used for the CFD tool. The size of the room is $6m(X){\times}6m(Y){\times}2.7m(Z)$. The exhaust diffuser was positioned diagonally to the supply diffuser. This diffuser was designed to have many holes, so the air supply had long throw patterns with low velocity decay. The characteristics of the indoor air flow was studied at volume flow rates of 5.1 CMM and 7.4 CMM, and a vane angle from $30^{\circ}$ to $60^{\circ}$, every $10^{\circ}$.

Simulation of Rough Rice Drying by Natural Air(II) : Factors Evaluation and Feasibility Study for Tropical Weather (자연공기(自然空氣)에 의(依)한 벼 건조(乾燥) 시뮤레이션(II) : 요인분석(要因分析) 및 열대기후하(熱帶氣候下)의 건조가능성(乾燥可能性) 조사(調査))

  • Chang, D.I.;Chung, D.S.
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.2
    • /
    • pp.270-277
    • /
    • 1984
  • The effects of factors of natural air drying were evaluated by the simulation model for rough rice drying. The factors were airflow rate, harvest date, initial moisture content and weather conditions. For simulation, the RICEDRY (Chang et al., 1983) was used. Then, the applicability of the model and the feasibility of rough rice drying by natural air were tested under the tropical weather conditions of Costa Rica.

  • PDF

THE ROLE OF GINSENG DRYING IN THE HARVEST AND POST-HARVEST PRODUCTION SYSTEM FOR AMERICAN GINSENG

  • Bailey W.G.;Dalfsen K.B. van;Guo Y.
    • Proceedings of the Ginseng society Conference
    • /
    • 1993.09a
    • /
    • pp.155-163
    • /
    • 1993
  • An American ginseng(Panax quillquefolium L) industry has emerged in British Columbia, Canada over the past ten years. Interest has grown very rapidly and with this development, attention is now moving away from field production issues and emphasis is being directed to enhancements in ginseng storage, drying and processing. There is a dearth of knowledge on these aspects even though they are crucial to international competitiveness. Enhancement dicatates the application of a systems approach to optimizing the harvest and post - harvest production system(crop digging, pre - washing cold storage. washing, drying and post - drying storage). Research in British Columbia to date has focussed on drying and storage issues and has resulted in the design of an enhanced commercial drying system. The role of dryer management, loading rates, airflow rates and pre - drying cold storage on American ginseng root drying rates and root quality were examined. From the dryer management experiments, there are distinct advantages to size sorting root to yield optimum drying rates. If unsorted root is used, efficiency is increased if the trays are systematically rotated. Loading rate experiments illustrate that increasing rates above those currently used in commercial dryers are possible without any sacrifice in quality. This has significant implications for commercial drying. Pre - drying cold storage is a most significant tool for managing drying operations. Over a period of six weeks, no discernable decrease in quality was found as a consequence of cold storage. Further, the moisture loss and the associated root surface changes(loss of surface soil in storage for example) provide new challenges for root quality management. Continued research and technological innovation will be crucial in addressing the demanding challenges of the future.

  • PDF

A Comparative Study on the Auxiliary Fan Pressure and the Ventilation Efficiency in Large-opening Limestone Mine Airways (대단면 석회석 광산 갱도 내 국부선풍기 승압력 및 통기효과 비교 연구)

  • Park, Dongjun;Kang, Hyeonho;Lee, Changwoo
    • Tunnel and Underground Space
    • /
    • v.27 no.1
    • /
    • pp.1-11
    • /
    • 2017
  • Most of the local limestone mines are developed as large-opening underground mines, while mine ventilation is heavily dependent on the natural ventilation and auxiliary systems, rather than the mechanical ventilation system using main fans. The current auxiliary ventilation system with fan and ducting requires optimization since enhanced deployment of diesel equipment demands higher airflow rate and the associated cost is expected to be too excessive for the local mine operators. This paper aims at optimizing the fan capacity for the working site ventilation through comparing the fan pressure in the mine airway and the ventilation efficiency of an axial-flow fan and a propeller fan developed in this study.

Impregnated Active Carbon-Shelf Life Studies and Its Evaluation Against Cyanogen Chloride with and without Canister

  • Singh, Beer;Saxena, Amit;Srivastava, Avanish Kumar;Dubey, Devendra Kumar;Gupta, Arvind Kumar
    • Carbon letters
    • /
    • v.8 no.4
    • /
    • pp.280-284
    • /
    • 2007
  • Samples of active carbon of $1150\;m^2/g$ surface area were impregnated with ammoniacal salts of copper, chromium and silver, with and without triethylenediamine. The samples of impregnated carbon were aged at $50^{\circ}C$, with and without 90% RH (relative humidity), for a little more than one year and chemically evaluated periodically. Initially copper (II) and chromium (VI) reduced very fast in the samples in humid atmosphere to the extent of 30% and 60% respectively in four months. These values were found to be unaffected by the presence of triethylenediamine (TEDA) indicating that the chemical did not retard the reduction process of chromium (VI) and copper (II). However, in the absence of humidity the reduction of the impregnants was significantly less (10-12%, w/w) in four months. It was quite evident; therefore, that the moisture was mainly responsible for the reduction of chromium (VI) and copper (II) species in impregnated carbons. The prolonged ageing of the samples with and without triethylenediamme after four months with and without humid atmosphere showed that the extent of reduction of chromium (VI) was very low, i.e. 5-10% and of copper (II) was 2-25%. Silver is not reduced due to carbon, as it remained unchanged in concentration on storage. The impregnated carbon samples (100 g) without triethylenediamine, which were aged at room temperature for 5 years in absence of humidity and unaged when evaluated against cyanogen chloride (CNCl) at a concentration of 4 mg/L and airflow rate of 30 lpm showed a high degree of protection (80- 110 minutes).

Comparison of Maximum Phonation Time Associated with the Changes in Vocal Intensity in Patients with Unilateral Vocal Fold Palsy and Sulcus Vocalis (성대마비와 성대구증의 강도 변화에 따른 최대발성지속시간 비교)

  • Choi, Se-Jin;Choi, Hong-Shik;Kim, Jae-Ock;Choi, Yae-Lin
    • Phonetics and Speech Sciences
    • /
    • v.4 no.1
    • /
    • pp.125-131
    • /
    • 2012
  • The patients with incomplete glottic closure have an important feature decreasing the maximum phonation time (MPT) because airflow rate or air leakage is greater than people without voice disorders. Also they can appear a problem in the intensity regulation. This study analyzed MPT difference based on the comfortable intensity and louder intensity and the correlation between MPT and respiration volume of unilateral vocal fold palsy (UVFP) and sulcus vocalis (SV) group. The twenty with UVFP, the 21 with SV, the 21 normal subjects measured MPT in /a/ vowel prolongation task with comfortable intensity and louder intensity and compared analysis by measuring FVC, $FEV_1$, $FEV_1/FVC$ to analyze the correlation between MPT and respiration volume. First, a comparison of MPT according to the intensity between groups is that MPT of the normal group was statistically significant long compared to the patient group in comfortable intensity, but MPT between groups was not statistically significant difference in the louder intensity. Second, an analysis of the correlation between MPT and respiration volume is that this was statistically significant correlation between MPT in comfortable intensity and MPT in louder intensity. But this did not show statistically significant correlation between intensity and respiration volume. This study can be supported the preceding study results deduced that shorting MPT of the patient group compared to the normal group was originated in the problem of laryngeal valving mechanism at the level of vocal folds rather than a problem of respiratory function. Also at the phonation by varying the intensity, the result can deduce that in the case of patient group, the length of MPT had been improved by increasing the glottal closure ratio in the louder intensity. These results can support the theoretical basis that should be applied to the clinicians by varying the intensity at the voice evaluation and voice therapy for the patients with the glottis incompetence.

The Effect of Transfer Modality, Temperature, and Application Time on Gastrocnemius Muscle Activation in Healthy People (한냉과 온열의 적용 시간과 전달 방식이 장딴지근의 근 활성도에 미치는 영향)

  • Lee, Young-Sin;Bae, Sea-Hyun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • PURPOSE: The purpose of this study was investigate the changes of gastrocnemius (GCM) muscle activity by applying different hot and cold therapeutic modalities. METHODS: A total of 20 healthy subjects were enrolled into the study. We selected transfer modalities that are frequently used in clinical settings: conduction, radiation, and convection. We performed hot pack, ice pack, and infrared therapy for 10, 20, and 30 minutes. After each application, a break was taken between each day. In addition, we performed cryotherapy for 3 min (airflow rate = $-6{\sim}-20^{\circ}C$). We measured muscle activity changes in the GCM muscle. RESULTS: For the conduction method, muscle activity significantly increased after ice pack therapy for 10 min and 20 min but decreased after hot pack therapy for 10 min and 20 min. For the radiation method, muscle activity significantly decreased after infrared therapy for 10 min and 20 min. For the convection method, muscle activity significantly increased after cryotherapy for 3 min and 10 min. There were no differences in the change of muscle activity in the conduction and radiation transfer method using heat. However, there were differences in the change of muscle activity in the conduction and convection transfer method with cold application. CONCLUSION: For a reduction in muscle activity, regardless of the transfer type, thermal application for 20 min would be effective. For an increase in muscle activity, cold pack application or cryotherapy for 20 min would be effective. This study could contribute toward therapeutic modality application in changing muscle activity.