• 제목/요약/키워드: Airborne pollutants

검색결과 69건 처리시간 0.026초

대구 안심연료단지 환경오염물질 노출 평가(II) - TSP, PM10, PM2.5 및 중금속 농도분포 및 노출특성 - (Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(II) - Concentration distribution and exposure characteristics of TSP, PM10, PM2.5, and heavy metals -)

  • 정종현;피영규;이준정;오인보;손병현;이형돈;윤미라;김근배;유승도;민영선;이관;임현술
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.380-391
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter pollution and its effect on health of residents living near Ansim Briquette Fuel Complex and its vicinities. Also, this study measured and analyzed the concentration of TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals which influences on the environmental and respiratory disease in Ansim Briquette Fuel Complex, Daegu, Korea. Methods: In this study, we analyzed various environmental pollutants such as particulate matter and heavy metals from Ansim Briquette Fuel Complex that adversely affected local residents's health. In particular, we verified the concentration distribution and characteristics of exposure for TSP, $PM_{10}$, and $PM_{2.5}$ among particulate matters, and heavy metals(Cd, Cr, Cu, Mn, Ni, Pb, Fe, Zn, and Mg). In that regard, the official test method on air pollution in Korea for analysis of particulate matter and heavy metal in atmosphere were conducted. The large capacity air sampling method by the official test method on air pollution in Korea were applied for sampling of heavy metals in atmosphere. In addition, we evaluated the concentration of seasonal environmental pollutants for each point of residence in Ansim Briquette Fuel Complex and surrounding area. The sampling measured periods for air pollutants were from August 11, 2013 to February 21, 2014. Furthermore, we measured and analyzed the seasonal concentrations(summer, autumn and winter). Results: The average concentration for TSP, $PM_{10}$, and $PM_{2.5}$ by direct influence area at Ansim Briquette Fuel Complex were 1.7, 1.4 and 1.9 times higher than reference region. In analysis results of seasonal concentrations for particulate matter in four direct influence and reference area, concentration levels for winter were generally somewhat higher than concentrations for summer and autumn. The average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were $0.0008{\pm}0.0004{\mu}g/Sm^3$, $0.0141{\pm}0.0163{\mu}g/Sm^3$, $0.0248{\pm}0.0059{\mu}g/Sm^3$, $0.0026{\pm}0.0011{\mu}g/Sm^3$, $0.0272{\pm}0.0084{\mu}g/Sm^3$, $0.4855{\pm}0.1862{\mu}g/Sm^3$, and $0.3068{\pm}0.0631{\mu}g/Sm^3$, respectively. In particularly, the average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were 1.9, 3.6, 2.1, 1.9, 1.4, 2.6, and 1.2 times higher than reference area, respectively. The continuous monitoring and management were required for some heavy metals such as Cr and Ni. Moreover, the average concentration in winter for particulate matter in direct influence area at Ansim Briquette Fuel Complex were generally higher than concentrations in summer and autumn. Also, average concentrations for TSP, $PM_{10}$, and $PM_{2.5}$ were from 1.5 to 2.0 times, 1.2 to 1.8 times, and 1.1 to 2.3 times higher than reference area, respectively. In results for seasonal atmospheric environment, TSP, $PM_{10}$, $PM_{2.5}$, and heavy metal concentrations in direct influence area were higher than reference area. Especially, the concentrations in C station were a high level in comparison with other area. Conclusions: In the results, some particulate matters and heavy metals were relatively high concentration, in order to understand the environmental pollution level and health effect in surrounding area at Ansim Briquette Fuel Complex. The concentration of some heavy metals emitted from direct influence area at Ansim Briquette Fuel Complex were relatively higher than reference area. In particular, average concentration for heavy metals in this study were higher than average concentrations in air quality monitoring station for heavy metal for 7 years in Deagu metropolitan region. Especially, the residents near Ansim Briquette Fuel Complex may be exposed to the pollutants(TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals, etc) emitted from the factories in Ansim Briquette Fuel Complex.

성남시 대기정유분새중 호흡성 분여에서 중금속의 농도 및 입경분포 (The Heavy Metals and Size Distribution of Respirable Suspended Particulate Matter at Sungnam City)

  • 권우택;유영식
    • 환경위생공학
    • /
    • 제9권1호
    • /
    • pp.53-61
    • /
    • 1994
  • Sungnam city, as a major satellite town, is located in the southeast of Seoul. Atmospheric conditions are so stable that air pollutants from various emissions are tend to resist change because Sungnam city is located in the Namhansansung valley. The industrial distribution of Sungnam city are composed of various manufactories such as foods, fibers, chemicals, machinery and electronics etc. The heavy metal concentrations and size distribution are the most important parameters influencing among the way in which respirable suspended particulate matter interact with the human respiratory system. Respirable suspended particulate matter was collected on glass fiber filters from April 1993 to February 1994 according to particle size using Anderson sampler during 10 days per month at Sungnam city. 6 heavy metals, Fe, Zn, Pb Mn, Cu and Cd, were analyzed by particle size with atomic absorption spectrophotometry . The results could be summarized as follows: 1. The annual arithmetic mean concentration of total suspended particulate was 116.3$\mu $g/m$^{3}$ m', seasonal variation was the highest in spring season(196.5$\mu $g/m$^{3}$) and the lowest in Summer Season(72.9$\mu $g/m$^{3}$). 2. The ratio of airborne particulate concentrations respirable to nonrepairable( Res/Non- Res) of annual arithmetic mean value was 5.8'1, seasonal variation was highest in the spring season(6.3 : 1) and lowest in the summer season(4.6 : 1). 3. During the spring season the shape of the size distribution was trimodal which showed peaks at 3 size groups, which were below of 0.43$\mu $m, 3.3∼4.7$\mu $m and above of 11.0$\mu $g/m$^{3}$ respectively. 4. Respirable suspended particulate matter concentrations of Zn, Pb Cu and Cd were the highest in below of 0.43$\mu $m as follows; 0.517$\mu $g/m$^{3}$, 0.411 $\mu $g/m$^{3}$, 0.062$\mu $g/m$^{3}$ and 0.0310$\mu $g/m$^{3}$ , respectively, Fe and Mn were the highest in the particle size range of 4.7 ∼ 7.0$\mu $m as follows; 2.504$\mu $g/m$^{3}$ and 0.095$\mu $g/m$^{3}$, respectively. 5. The Pt Cd, Zn, Cu, Fe and Mn concentrations of annual arithmetic mean value respirable to non- respirable( Res/Non- Res ) were 33.65, 19.27, 17.74, 10.54, 3.20 and 5.20, respectively.

  • PDF

일반 인구집단에 대한 대기중 총먼지의 생물학적 노출지표로서 요중 1-hydroxypyrene 및 2-naphthol의 유용성 (Urinary 1-Hydroxypyrene and 2-Naphthol as a Biological Exposure Markers of Total Suspended Particulate in the General Population)

  • 강종원;김헌;강대희;이철호;조수헌
    • Journal of Preventive Medicine and Public Health
    • /
    • 제33권3호
    • /
    • pp.306-312
    • /
    • 2000
  • Background : Polycyclic aromatic hydrocarbons (PAH) are well known environmental pollutants. The measurement of PAH in ambient air is not commonly used, because it is quite difficult to perform and is unreliable. Using biomarkers of PAH can be an alternative approach to this problem. The PAH in ambient air is absorbed in particulate matter. Total suspended particulate(TSP) or particulate matter of less than $10{\mu}m$ in diameter (PM10) can be easily measured. Therefore, TSP or PM10 can be used as a surrogate measurements of ambient air PAH. Objectives : We investigated whether the urinary concentration of two biomarkers of PAH, 1-hydroxypyrene (1-OHP) and 2-naphthol, could reflect the total suspended particulate in the general population. Methods : In order to exclude the effects of occupational exposure and smoking, first grade middle school students were included in this study. Four middle schools within a one kilometer boundary of ambient air monitoring stations were selected. Total suspended particulate was regarded as the marker of airborne PAH. Diet and smoking data were collected by self administered questionnaires, and spot urine samples were collected. Urinary 1-OHP and 2-naphthol were analyzed by high performance liquid chromatography. Results : The correlation between urinary 1-OHP, 2-naphthol and passive smoking was not statistically significant. The correlation between urinary 1-OHP and TSP indices was not statistically significant. The correlations between urinary 2-naphthol and TSP of two lag days, one lag day, and zero lag days were statistically significant. The statistical significance of two lag days was the strongest (p=0.001), one lag day was the next (p=0.0275), and zero lag days was the weakest (p=0.0349). Conclusion : Our results imply that the urinary concentration of 2-naphthol can be applied as a PAH exposure marker for the general population with low PAH exposure.

  • PDF

장기관측자료를 이용한 DOAS와 점측정 분석시스템의 바이어스 구조에 대한 평가 (Compatibility of DOAS and Conventional Point Monitoring System Through an Evaluation of Bias Structures Using Long-term Measurement Data in Seoul)

  • 김기현;김민영
    • 한국대기환경학회지
    • /
    • 제17권5호
    • /
    • pp.395-405
    • /
    • 2001
  • To make an assessment of the compatibility between DOAS and conventional point monitoring system (MCSAM-2: MS2), we investigated the concentrations of three criteria pollutants which include S $O_2$, N $O_2$, and $O_3$from a national monitoring station in Seoul during the periods of June 1999~August 2000. The average concentration values for the whole study period derived from hourly concentration data sets of those three species indicated that the mean differences between the two methods can be approximated as 18%. When the bias structure of two systems was evaluated through the computation of percent difference(PD) between the two such as ( $C_{DOAS}$- $C_{conventional}$ $C_{DOAS}$*100, differences between the two systems appeared to be quite systematic among different compounds. While the mode of bias peaked at 0~20% or 20~40% in terms of PD values, the cause of such positive bias mainly arised from generally enhanced concentration values of DOAS system. The structure of bias among different species was further assessed through linear regression analysis. Results of the analysis indicated that the dominant portions of differences observed from two monitoring systems can be accounted for by the systematic differences in their spanning and zeroing systems. S $O_2$(MS2)=0.6385 S $O_2$(DOAS)+2.0985($r^2$=0.7894) N $O_2$(MS2)=0.6548 N $O_2$(DOAS)+7.437($r^2$=0.7687) $O_3$(MS2)=1.0359 $O_3$(DOAS)-7.7885($r^2$=0.7944) The findings of slope values at around 0.64~0.65 from two species suggest that DOAS should respond more sensitively in upper bound concentration range. The offset values apart from zero indicate that more deliberate comparison needs to be made between these monitoring systems. However, based on the existence of strong correlations from at least 8,000 data points for each species of comparison, we were able to conclude that the compatibility of two monitoring systems is highly significant. With the improvement of calibration techniques for the DOAS system. its applicability for routine monitoring of airborne pollutant species is expected to be quite extendable.

  • PDF

백서 기관 점막의$SO_2$ 노출 후 회복과정의 조직학적 관찰 및 laminin의 발현에 관한 연구 (The Histologic Findings and the Expression of Laminin in the Mucosa of the Rat Trachea During)

  • 이형석;태경;조석현;한장희;정진석
    • 대한기관식도과학회지
    • /
    • 제8권1호
    • /
    • pp.29-34
    • /
    • 2002
  • Background and Objectives : Sulfur dioxide gas is one of the major airborne Pollutants noxious to human in industrialized countries. The most vulnerable areas in the human respiratory system were the trachea and main bronchi and a gradient of decreasing damage was observed in the peripheral tracheobronchial tree. Induced functional alteration was increased mucosal permeability, and morphological changes were epithelial sloughing, intracellular edema, mitochondrial swelling, widened intercellular spaces, and ciliary cytoplamic extrusions. The laminins are a family of extracellular matrix glycoproteins localized in the basement membrane. Their primary role is cell-matrix attachment, but many additional biologic activities, including Promoting cell growth and migration, tumor growth and metastasis, wound repair, and graft survival, have been demonstrated. Materials and Methods : Histologic changes and expression of laminin in tracheal mucosa sacrificed at 1 day, 2 day, 3 day, 1 week, 2 weeks, and 3 weeks after continued SO2 exposure of 250 ppm for 30 minutes a day(to 7week) were studied in rats. In this study, mild immune reaction for laminin was noted at the apical cytoplasm of epithelial cells and basement membrane one day after a 7 week $SO_2$ exposure. The cilia and nucleoi of epithelial cells were normal and no immune reaction was noted in Goblet cells. The lamina propria of the tracheal tissue was infiltrated by monocytes and lymphocytes. Results : At 24 hours after exposure, all tracheal cells except Goblet cells revealed a mild immune reaction for laminin. No immune reactions were noted in the basement membrane. At 72 hours after exposure, mild or moderate immune reactions for laminin was seen in the tracheal cell cytoplasm. Irregular faint immune reaction for laminin was noted in the basement membrane. At 1 week after exposure, strong immune reaction for laminin was detected over all tracheal cells, and the basement membrane was seen clearly. At 2~3 weeks after exposure, strong immune reaction for laminin was seen in all tracheal epithelial cells except Goblet cells and a mild immune reaction was partly revealed in the basement membrane. Conclusion : Our study suggests that 502 produces histologic damage on the tracheal mucosa. Longer duration after exposure of $SO_2$ makes more progressive healing on the tracheal mucosa and increased immunoreactivity for laminin.

  • PDF

일개 실내수영장의 공기 중 염소 및 트리할로메탄의 노출평가 및 환기 효율 평가 (Assessment for Inhalation Exposure to Trihalomethanes (THMs) and Chroline and Efficiency of Ventilation for an Indoor Swimming Pool)

  • 박해동;박현희;신정아;김태호
    • 한국환경보건학회지
    • /
    • 제36권5호
    • /
    • pp.402-410
    • /
    • 2010
  • The objectives of this study were to evaluate the air quality surrounding an indoor swimming pool, to estimate the cancer risk based on the airborne exposure to trihalomethanes (THMs), and to examine the ventilation efficiency by Computational Fluid Dynamics (CFD). Chlorine and THMs were measured poolside, and in the staff room and reception area. The indoor swimming pool was modeled using the Airpak program, with ventilation drawings and actual survey data. Temperature, flow and mean age of the air were analyzed. Levels of chlorine poolside, and in the staff room, and reception area were $203\;{\mu}g/m^3$, $5\;{\mu}g/m^3$, and $10\;{\mu}g/m^3$, respectively. Chloroform was the dominant THM in all sampling sites and mean concentrations were $16.30\;{\mu}g/m^3$, $0.51\;{\mu}g/m^3$, and $0.06\;{\mu}g/m^3$ poolside, in the staff room and reception area, respectively. Bromodichloromethane and Dibromochloromethane levels were respectively estimated as $10.3\;{\mu}g/m^3$ and $1.7\;{\mu}g/m^3$ poolside, $1.3\;{\mu}g/m^3$ and $0.1\;{\mu}g/m^3$ in the staff room, and were not detected in the reception area. The cancer risks from inhalation exposure to THMs were estimated between $3.37{\times}10^{-7}$ and $1.84{\times}10^{-5}$. A short circulation phenomenon was observed from the supply air vents to the exhaust air vents located in the ceiling. A high temperature layer was formed within one meter of the ceiling, and a low temperature layer was formed under this layer due to the low velocity and high temperature of the supply air, and the improper locations of the supply air vents and exhaust air vents. The stagnation was evident at the above adult pool and the mean age of the air was 22 minutes. Disinfection by-products in the indoor swimming pool were present in higher concentrations than in the outdoor air. In order to increase the removal of pollutants, adjustment was required of the supply air volume and the supply/exhaust position.

솔잎추출물을 혼입한 시멘트 경화체의 항균류 저항 특성 (Antimicrobial Properties of Cement Matrix using Pine Needle Extract)

  • 김호진;정현의;임동현;한송이;박선규
    • 한국건설순환자원학회논문집
    • /
    • 제10권1호
    • /
    • pp.117-123
    • /
    • 2022
  • 현대인은 대부분의 시간을 실내에서 보내고 있기 때문에 실내 공기질에 대한 관심이 높아지는 추세이다. 실내 공기의 주요 오염원으로는 인간의 활동, 건축자재, 생활용품, 외부로부터 오염된 대기의 유입 등을 들 수 있다. 실내 공기질 관리법에서는 실내공기 오염물질로 미세먼지, 총 부유세균, 곰팡이, 이산화탄소 등 17종을 규정하고 있다. 현대인의 실내 환경은 세균과 곰팡이균의 생육환경이 흡사하기 때문에 일상생활에서 세균과 곰팡이에 항상 노출된다. 특히 많은 사람이 모이는 다중이용시설의 경우에는 세균감염의 위험이 더 크다고 할 수 있다. 한편 솔잎은 예전부터 항균효과가 뛰어난 것으로 알려져 있으며, 한약재, 식용 등 쓰임새가 다양하다. 그 외에 의약, 식품 및 염색제 관련 산업에서는 적극적으로 활용하고 있으며, 최근에는 건축자재로 이용하기 위한 시도도 이루어지고 있는 실정이다. 솔잎의 항균효과에 관한 연구는 상당히 많이 이루어지고 있으며, 다양한 항균 성분을 가지고 있다. 따라서 본 연구는 솔잎 추출물의 항세균, 항곰팡이 효과를 확인하였으며, 이를 토대로 솔잎 추출물을 혼입한 시멘트 경화체를 제작해 솔잎 추출물의 혼입 비율별 세균과 곰팡이에 대한 항균 활성 효과를 연구하였다. 솔잎 추출물은 황색포도상구균과 대장균에 대해 항세균 효과를 나타났으며, 검정 곰팡이에 대해 생육환경을 저해하는 것이 나타났다. 솔잎 추출물을 혼입한 시멘트 경화체는 황색포도상구균과 대장균에 대해서 항균 활성 효과를 나타냈다. 그러나 검정 곰팡이에 대해서 항균 활성 효과를 나타내지 않았다. 결과적으로, 솔잎추출물을 혼입한 시멘트 경화체는 병원균 억제에는 효과적이지만 곰팡이에 대해서는 효과가 없는 것으로 판단되며, 솔잎추출물을 항균재료 사용하기 위해서는 곰팡이의 생육을 저해하는 요인에 대한 추가적인 연구가 필요할 것으로 판단된다.

2005년 동아시아 지역에서 발생한 모래폭풍과 먼지침전(황사)의 관측 (On the Observation of Sandstorms and Associated Episodes of Airborne Dustfalls in the East Asian Region in 2005)

  • 김학성;정용승
    • 한국지구과학회지
    • /
    • 제30권2호
    • /
    • pp.196-209
    • /
    • 2009
  • 2005년 1월부터 12월까지 지속적으로 몽골과 중국 북부의 사막과 건조지대에서 모래폭풍의 발생, 이동 그리고 한국에서 먼지침전(황사)을 모니터링하였다. NOAA 위성의 AVHRR(Advanced Very High Resolution Radiometer) 관측 자료를 직접 수신하여 false colour 합성영상을 만들어 모래폭풍의 발생과 이동 사례를 중점 분석하였다. 또한 모래폭풍 발원지의 풍하측에 위치한 한국 중부의 청원에서 PM10 농도가 $190{\mu}g\;m^{-3}$ 이상인 황사 사례에 대한 PM10, PM2.5농도와 시정 그리고 $O_3,\;NO_2,\;CO,\;SO_2$ 농도의 변동을 분석하였다. 2005년에는 발원지에 적설과 강력한 고기압, 저기압의 이동이 미흡하여 강한 모래폭풍의 발생이 적었고 한국에서도 황사의 발생 빈도가 1997-2005년의 평균과 비교하여 적었다. 한국에는 2005년 총 7회, 11일간의 황사 사례가 발생하였다. 여름에는 발원지가 습하고 바람이 약해 모래폭풍의 발생이 적었으며, 한국에서도 황사의 발생이 없었다. 발원지에서 발생한 모래폭풍이 중국의 대도시와 산업지대를 거치지 않고 한국으로 직접 이동할 경우, 먼지침전에 따른 PM2.5 농도는 PM10 농도의 20% 이하였다. 그러나 모래폭풍이 중국 동부의 산업지역을 거쳐 한국으로 이동할 경우 인위적 대기오염 물질이 함께 유입되어 PM2.5 농도가 증가하여 PM10농도의 25%이상을 나타내었다. 또한 2005년에는 사막에서 날아온 모래 먼지의 PM10농도가 $190{\mu}g\;m^{-3}$ 이하여서 황사로는 미흡한 5개 이상 사례를 관측 및 분석하였다.

만성기침환자에서 비강최대흡기유속 측정의 의의 (Clinical Significance of Nasal Peak Inspiratory Flow Rate in Patients with Chronic Cough)

  • 안창혁;이병훈;박용범;최재철;지현석;박성진;강순복;김재열;박인원;최병휘;허성호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권5호
    • /
    • pp.654-661
    • /
    • 1999
  • 연구배경 : 만성기침환자에 있어서 비폐색과 같은 주관적인 상기도 증상을 객관적인 지표로 나타내어 비교할 수 있게 하기 위해, 최근 비교적 높은 재현성을 보이는 것으로 보고된 비강최대흡기유속을 측정하여 만성기침환자들에서 비폐색을 객관적으로 측정해보고자 하였다. 방 법 : 정상인 7명에서 하루 2회씩 3일 동안 휴대용 폐활량 측정기를 이용하여 비강최대흡기유속과 폐기능검사를 시행하였다. 이들 7명을 포함한 총 32명의 정상인들과 만성기침환자 32명을 선별하여 최초 첫 방문 시에 비강최대흡기유속과 폐기능검사를 시행하였다. 결 과 : 정상인 7명에 대해서는 비교적 일관된 비강최대흡기 유속과 $FEV_1$ 및 FVC를 얻을 수 있었다. 만성기침환자는 남자 14명, 여자 18명으로 총 32명이었으며 나이는 $41.4{\pm}15.9$세였으며, 정상인은 남자 22명, 여자 10명으로 총 32명이었으며 나이는 $39.8{\pm}18.6$세였다. 만성기침환자군과 정상인군 사이의 연령 및 폐기능검사 상의 차이는 없었다. 만성기침환자들에서 비강최대흡기유속은 $2.25{\pm}0.68\;L/sec$, 정상인들에서는 $2.75{\pm}1.00\;L/sec$로 만성기침환자에서 의미 있게 낮았다(p=0.02). 만성기침환자들 중, 후비루종후군환자들이 27명으로 가장 많았으며, 비강최대흡기유속은 $2.18{\pm}0.66\;L/sec$로 정상인 $2.75{\pm}1.00\;L/sec$ 보다 더욱 의미 있게 낮았다(p=0.006). 결 론 : 비강최대흡기유속은 만성기침환자들에 있어서 주관적인 비폐색 증상을 객관적으로 보여주는 지표이다. 비강최대흡기유속은 비교적 재현성 있는 지표이며, 정상인에 비해서 만성기침환자, 특히 원인 질환이 후비루 증후군인 환자들에서 특히 감소되었다. 하지만, 양군간의 값이 중복되는 범위가 많아서 진단 및 감별진단의 지표로서의 가치는 좀 더 많은 대상에 대한 연구에 의하여 확인되어야 할 것으로 생각된다.

  • PDF