• 제목/요약/키워드: Airborne microbes

검색결과 27건 처리시간 0.027초

병원내 감염에 영향을 미치는 공기오염 상태에 대한 조사 연구 (A Study on Airborne Microbes Contamination that Influences on Nosocomial Infection)

  • 최영희;박정호;윤혜상;문영숙
    • 대한간호학회지
    • /
    • 제12권1호
    • /
    • pp.39-52
    • /
    • 1982
  • Nosocomial infection is important in the management of the nursing care and has been found to be related with the airborne microbes contamination. The purpose of this study is to identify the differences of the airborne microbes between hospitals, nursing units, days and times and to identify the difference in the types of microorganisms between hospitals, nursing units, days and times. This study was conducted from May 25, to July 10, 1981, according to R. Koch's methods for quantative samplings of airborne microbes and the results of this study were reviewed in a statistical method. The following conclusions were obtained: 1. There was a significant difference in the types of airborne microbes between 8 hospitals (F=5.0491, p<0.01) 2. There was a significant difference in the types of airborne microbes between surgical, medical, nursery, 1.C.U., operating theatre and outpatient nursing unit. (F=2.1764, p<0.05) 3. There was not a significant difference in the types of airborne microbes between Monday, Thursday and Saturday (F= 1.6365, p>0.05) 4. There was a significant difference in the types of airborne microbes between AM 7 : 00, AM 11:00 and PM 3 : 00. (F=7.2951, p<0.01) 5. 4061 colonies were divided into more 48 types and the classification was as follows. gram positive cocci (2024 colonies) 49.3% gram positive bacillus (1211 colonies) 29.8% gram negative bacillus (577 colonies) 14.2% fungus(200colonies) 4.9% gram negative cocci (41 colonies) 1.0% other's(8 colonies) 0.3% 6. There was a significant difference of airborne microbes between 8 hospitals. (F=7.7943, P<0.01) 7. There was not a significant difference of airborne microbes between 6 nursing units. (F= 1.8461, P>0.05) outpatient nursing unit : 12.6 colonies surgical nursing unit. 10.4 colonies Medical nursing unit : 9.8 colonies nursery nursing unit : 9.4 colonies operating theatre nursing unit:8.2 colonies Intensive care nursing unit : 7.8 colonies 8. There was not a significant difference of airborne microbes between Monday, Thursday and Saturday. (F=1.4371, p>0.05). Saturday : 11.0 colonies Monday : 9.1 colonies Thursday : 9.1 colonies 9. There was a significant difference of airborne microbes between A. M. 7 ; 00, A. M. 11 : 00 and P .M. 3:00 (F=7.6658, p<0.05) P. M. 3 : 00 : 12.2 colonies A. M. 11 : 00 : 10.0 colonies A. M. 7 : 00 : 7.1 colonies.

  • PDF

종합병원내 부유 미생물 농도 및 환경 요인과의 상관성 조사 (Investigation on Concentrations and Correlations of Airborne Microbes and Environmental Factors in the General Hospital)

  • 이창래;김기연;김치년;박동욱;노재훈
    • 한국산업보건학회지
    • /
    • 제15권1호
    • /
    • pp.45-51
    • /
    • 2005
  • This survey was performed to measure concentrations of airborne microbes, utilizing the six-stage cascade air sampler, according to the sampling site and time in the general hospital and to evaluate the degree of correlations between airborne microbes and environmental factors. Besides the main lobby, airborne microbes and environmental factors were not significantly different between the forenoon(9:00-10:00 AM) and afternoon(2:00-3:00 PM). Concentrations of airborne bacteria and fungi were 404 and $156CFU/m^3$ in the main lobby, 188 and $56CFU/m^3$ in the intensive care unit, 323 and $96CFU/m^3$ in the ward, 239 and $127CFU/m^3$ in the laboratory, and 139 and $33CFU/m^3$ in the newborn baby room, respectively. As a result, the level of airborne microbes was significantly highest in the main lobby and lowest in the newborn baby room(p<0.05). Outdoor airborne microbes concentrations were significantly lower than those of the sampling sites in the general hospital except for the newborn baby room(p>0.05). It was observed that temperature, relative humidity and carbon dioxide in the general hospital had generally positive correlation with airborne microbes. However, there was no correlation between the odor index level and airborne microbes.

일부 병원 실내에서의 공기중 미생물 오염에 관한 연구 (A Study on Airborne Microorganism in Hospital)

  • 정선회;백남원
    • 한국산업보건학회지
    • /
    • 제8권2호
    • /
    • pp.231-241
    • /
    • 1998
  • To assess biological indoor air quality in hospital, concentrations of viable airborne microbes were determined at intensive care unit(ICU), patient room (PR), outpatient waiting room(OPWR) in hospitals of large(1000 beds), middle(500 beds), small(100 beds) hospitals, respectively. Gram positive bacteria, gram negative bacteria, fungi were sampled using suctional sampling method by RCS sampler (Reuter centrifugal air sampler) and RCS GK-A agar plate. In gram positive bacteria groups, CNS(Coagulase Negative Staphylococcus), Micrococcus, Lactobacillus, S. aureus, Enterococcus, St. viridans identified. In gram negative bacteria groups, A. baumannii, Kl. peumoniae and E. coli were identified, and Penicillium was identified in fugi groups. Results of the study were as follows. 1. The highest concentrations of airborne microbes was $971CFU/m^3$ at 5:00 PM in small hospital patient room, and average concentrations of airborne microbes in large, middle and small hospitals were $282CFU/m^3$, $289CFU/m^3$ and $625CFU/m^3$, respectively. Average concentrations of airborne microbes in office(control) was $90CFU/m^3$. Thus, the small hospital showed the worst condition. 2. Representatives of 8 different genera were identified in 150 samples. The most frequently isolated organisms were Staphylococcus (73.0%), Micrococcus (20.7%) and Lactobacillus (4.7%), respectively. Pathogenic microbes isolated were A. baumannii, E. coli, Enterococcus, Kl. peumoniae, S. aureus, St. viridans and Penicillium as fungi. In office, no pathogenic microbes were identified. Average concentrations of airborne pathogenic microbes in large, middle and small hospital were $5CFU/m^3$ (2%), $11CFU/m^3$ (4%) and $12CFU/m^3$ (2%), respectively. Thus, condition in a large hospital was better than those in a middle and a small hospital.

  • PDF

일지역 신경외과 중환자실내의 통행량에 따른 낙하균 분석 (A Study of Airborne Microbes in the NSICU According to Number of Persons Who Pass through Every Hour)

  • 박형숙;강인순;김진화;어현주
    • 기본간호학회지
    • /
    • 제11권1호
    • /
    • pp.41-48
    • /
    • 2004
  • Purpose: The purpose of this study was to analyze the colony count of airborne microbes contamination every hour in the Neurosurgical Intensive Care Unit (NSICU) in order to identify the relationship of colony count to person-visits. Method: Data were collected during from 11:00 a.m. September 5 to 11:00 a.m. September 6, 2002. This study used blood agar & nutrient agar and handtally counter (USA) for collection of airborne microbes and number of person-visits. Data was analyzed using the SPSSWIN 10.0 with means, Pearson correlation coefficient, and simple regression. Result: The result of this study are as follows. Total colony count of airborne microbes for 24 hours in the NSICU was 4,609. Total number of person-visits to the NSICU was 15,347. The highest scores fur the total colony count in different areas of the NSICU was the rear door, followed by the preparation room, and the front entrance, while the lowest count was in the isolation rooms. There was a statistically significant relationship between colony count and number of person-visits to the NSICU. The most frequently airborne microbes in the NSICU were Micrococcus, CNS, Staphylococcus Micrococcus, Aureus. Conclusion: These findings indicate that the number of person-visits in hospitals influences total colony count of airborne microbes. This study contributes to assessment of biological indoor air quality in hospital and in the development of an NSICU care plan.

  • PDF

전기 영동을 이용한 공기 중 미생물 분리 (Dielectrophoretic separator for Airborne Microbes)

  • 문희성;남윤우;박재찬;정효일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1683-1684
    • /
    • 2008
  • For direct detection of microbes in air, samples have to be collected but environmental particles such as dust are also trapped in such samples. Therefore the isolation of target bacteria from non-biological materials of similar size is of great importance in the identification of such organisms. Dielectrophoresis is an emerging technique that can rapidly separate cells in microfluidics. In this paper we proposed a new method for the separation of airborne microbes using condensation and dielectrophoresis. This system could be used as a continuous flow through separation system for various particles and utilized as a pretreatment technique for microbe detection.

  • PDF

일부 학교급식소 조리실의 위생관리에 관한 조사연구 (A Survey on the Sanitary Condition of Kitchens in School Food-service Programs)

  • 김종규
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.87-93
    • /
    • 2003
  • A survey including an inspection was conducted to assess the sanitary condition of kitchens in the school food-service programs and to prepare background data for improving the safety of school meals. The survey was carried out over a two-month period (September-October, 2001). A self-administered questionnaire recommended by the Korea Ministry of Education & Human Resources Development (MOEHRD) was offered to a random sample of dieticians of twenty-five elementary schools in one region of Korea about food, sanitation, and safety inspection of their kitchens. Air temperature, relative humidity, and airborne microbes in the kitchens were monitored during preparation, cooking, and service. The inspection results showed their sanitary rendition met the level B of the recommendation of the Korea MOEHRD. The range of air temperature of the kitchens was 21.4~22.4$^{\circ}C$. and the range of relative humidity was 62.4~69.6%. The microbiological evaluation of kitchen samples indicated aerobic plate count levels from 22..5 to 26.5 CFU/15 minutes. Although the results of inspection show that the levels of sanitary condition of kitchens in the schools were good, they are not satisfactory for safe food-servile because the temperature and humidity levels are high. This study indicates that the school kitchens should be monitored and strict inspection is necessary. The legal standards for school food-service should include standards for kitchen air temperature, relative humidity, and airborne microbes.

Levels of Bioaerosols in Cattle Sheds and Nearby Farmers' Houses in Korea

  • Kang, Jung-Hwan;Jo, Wan-Kuen
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제23권E1호
    • /
    • pp.1-9
    • /
    • 2007
  • In Korea, there is only a limited amount of information currently available on the levels of airborne bacteria and fungi of cattle sheds, although certain portions of people are potentially exposed to these bioaerosols in cattle sheds. Accordingly, the current study measured them inside cattle sheds, inside and outside farmers' houses near the sheds, and/or inside residential houses far away from the sheds during winter, 2004 and summer, 2005. The airborne bacteria and fungi were detected in most samples in the cattle farmers' houses as well as in the cattle sheds. Aspergillus, Cladosporium, and Penicillium, which have been associated with adverse health effects, were three most prevalent fungal genera, and they took most of the total fungi (more than 69%). The microbial concentrations measured inside the cattle sheds were comparable to those in other reports. Nevertheless, the present arithmetic and geometric mean (GM) microbial concentrations exceeded the Korean guideline for total airborne bacteria at medical facilities ($800\;CFU\;m^{-3}$), the current GM residential indoor concentrations at houses, and the residential indoor levels reported in other countries. The present findings suggest the need for a strategy to reduce Korean cattle farmers' exposure to these microorganisms. In contrast to the microbes, it is suggested that the cattle shed is not an important microenvironment for $PM_{10}$ exposure. Two characteristics examined in this study (seasonal variation and summer survey period, i.e., temperature and humidity) were all important for the cattle farmers' occupational exposure to airborne microbes. The lack of constancy between highest and lowest concentrations of bioaerosols over the survey period further suggests the necessity of performing a long-term survey to better examine farmer exposure levels and their variability.

대학급식소 작업시설과 환경의 미생물 오염도 분석 및 작업환경 실태조사 (Investigation of Microbial Contamination and Working Environment in University Foodservices)

  • 박순희;문혜경
    • 대한영양사협회학술지
    • /
    • 제23권2호
    • /
    • pp.180-191
    • /
    • 2017
  • The purpose of this study was to identity the probability of cross-contamination from the environment. For this, we examined foodservices at 20 universities/colleges for microbiological analysis of their working facilities and environment as well as their preventive equipment against cross-contamination. Seventy percent of the 20 foodservices were found to maintain one unified working area, which suggests high probability of contamination of food/utensils/equipment in the cooking area by pre-preparation or dish washing. According to the microbiological analysis, the hygiene acceptance ratio of working facilities in the clean zone was 70%, which was higher than the average 45% hygiene acceptance ratio of working facilities in the contamination operating zone. There was a significant difference in the total plate count (P<0.001) and coliform count (P<0.01), which demonstrates that work tables in the clean zone were in a good state compared to those in the contamination operating zone. In the contamination operating zone, refrigerator shelves had a high probability of cross-contamination. Regarding the floor surface and airborne microbes, cooking areas which should be maintained as clean zones had higher cross-contamination probability than those in the contamination operating zone. So corrective actions such as cleaning and sanitizing, keeping dry floors, lowered temperature and humidity, shoe disinfecting facilities, and checking concentrations, are necessary to manage floor surfaces and airborne microbes in the cooking area.

미생물을 이용한 일부 병원, 가정 및 일반 대기질의 평가 (Assessment of Indoor and Outdoor Air Quality through Determination of Microorganism)

  • 하권철;백남원
    • 한국산업보건학회지
    • /
    • 제1권1호
    • /
    • pp.73-81
    • /
    • 1991
  • To assess biological air quality, concentrations of viable airborne microbes were determined in hospital home and outdoor air from August 25 to October 18, 1990. Bacteria, fungi and thermophilic bacteria were sampled using gravitational and suctional sampling method. In bacteria groups, the Staphylococcus spp. was identified by microscopic examination and biochemical tests. Results of the study are as follows. 1. Results using the gravitational sampling method indicated that average numbers of airborne microbes in hospital home and outdoor air were 21.5, 12.2 and 17.6 CFU/plate, respectively. These levels are well within an appropriate standard of 50 CFU/plate suggested by Endo. 2. Results using the suctional sampling method indicated that total airborne microbe concentrations in hospital, home and outdoor air were 1,998, 1,363 and $1,880CFU/m^3$, respectively. All of the results were within the recommended remedial action level, $10,000CFU/m^3$ of the American Conference of Governmental Industrial Hygienists(ACGIH). 3. Concentration of thermophilic bacteria in hospital and outdoor air were 79 and $111CFU/m^3$, respectively. Thermophilic bacteria were not detected in the home air. These results were within the remedial action level, $500CFU/m^3$. 4. Concentrations of Gram negative bacilli in holpital home and outdoor air were 20.3, 23.6 and $16.8CFU/m^3$, respectively. all were within the remedial action level, $500CFU/m^3$, recommended by ACGIH. 5. Concentrations of Staphylococcus spp. in hospital, home and outdoor air were 34.8, 14.7, and $22.4CFU/m^3$. respectively. all were within the remedial action level, $75CFU/m^3$, recommended by ACGIH. The percentages of Staphylococcus spp. in total bacteria in hospital, home and outdoor air were 19.0, 10.2 and 14.5%, respectively.

  • PDF

노래방과 컴퓨터 게임방 내의 실내공기오염에 관한 연구 (A Study on the Indoor Air Pollution of Singing Room and PC Room)

  • 이주상;원정일;이철민;김윤신
    • 환경위생공학
    • /
    • 제17권3호
    • /
    • pp.67-74
    • /
    • 2002
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. Since most people spend a large majority of their time indoors, indoor air may affect human health more than outdoor air. This outline survey was carried out to investigate the extent of indoor air pollution in singing room and PC room. The concentrations of major indoor air pollutants(carbon dioxide, total suspended particulate, airborne microbes) and Thermocircumstance(temperature, relative humidity, intensity of illumination) were observed from October 1 to 31, 2001. As results of the survey, the mom values of thermocircumstance in singing room and PC room were $22.1^{\circ}C$ of temperature, 37.1% of humidity, 75 Lux of intensity of illumination and $22.0^{\circ}C$ of temperature, 52.6% of humidity, 135 Lux of intensity of illumination, respectively. The mean concentrations of carbon dioxide were 1589 ppm in singing room and 615 ppm in PC room, respectively The concentrations of carbon dioxide in singing room were higher than the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs. The mean concentrations of total suspended particulate were $0.33{\;}mg/\textrm{m}^3$ in singing room and $0.57{\;}mg/\textrm{m}^3$ in PC room respectively. The mean concentrations of airborne microbe were $16{\;}CFU/\textrm{m}^3$ in singing room and $12{\;}CFU/\textrm{m}^3$ in PC room, respectively.