• Title/Summary/Keyword: Airborne concentration

Search Result 409, Processing Time 0.023 seconds

Size Characterization of Urban Airborne Particles Using Sedimentation/Steric Field-Flow Fractionation (Sd/StFFF)

  • Lee, Jae-Yong;Lee, Seung-Ho;Min, Young-Hong;Hyun, Dae-Yeung
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.8
    • /
    • pp.1172-1176
    • /
    • 2003
  • This study aims to investigate the applicability of Sd/StFFF and to develop a method for size characterization of urban airborne particles, focusing primarily on particles larger than about 1 mm. It was found that the airborne concentration vary with time, although no particular seasonal trend was observed. When averaged over time, the airborne concentration was the lowest in the park areas with 99 ㎍/m³. The apartment, industrial, and central city area showed similar levels of the airborne concentrations with 166, 170, and 171 ㎍/m³, respectively. The housing area showed the highest airborne concentration with 201 μg/m³ among all tested areas. A power-programmed Sd/StFFF was used for size analysis of airborne particles with the initial field strength of 300 rpm, $t_a$ = 4, $t_i$ = -16, p = 8, and the flow rate of 7 mL/min. It was found that urban airborne samples were mostly populated by particles having diameters between about 5 to 20 ㎛, although all have broad size distributions ranging up to about 50 ㎛. Under the Sd/StFFF condition used in this study, no significant differences were found in size distributions among the airborne particles collected at different urban sites, and also among those collected at different times.

Airborne Fungi Concentrations and Related Factors in the Home (가정 내 부유 진균의 농도와 관련 요인)

  • Cho, YongMin;Ryu, SeungHun;Choi, Min Seok;Seo, SungChul;Choung, Ji Tae;Choi, Jae Wook
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.5
    • /
    • pp.438-446
    • /
    • 2013
  • Objectives: This study was performed in order to determine airborne fungi levels in homes and find related factors that may affect airborne fungi concentration. Methods: Fifty homes were study subjects for measuring airborne fungi. For sampling airborne fungi, the impaction method on agar plates was used and samples were counted as colony forming units per cubic meter of air ($CFU/m^3$). In addition, information regarding housing characteristics and atopic disease in each home were collected via questionnaire. Results: The geometric means (GM) of airborne fungi concentrations in fifty living rooms and bedrooms were 68.03 and 62.93 $CFU/m^3$, respectively. The GM of airborne fungi concentration in atopy homes was 78.42 $CFU/m^3$. This was higher than non-atopy homes' 54.34 $CFU/m^3$ (p-value=0.051). In the results of the multiple regression analysis, outdoor airborne fungal concentration proved a strong effective factor on indoor airborne fungal concentration. Also, construction year, floor area of house, indoor smoking and frequency of ventilation were factors that showed a significant association with indoor airborne fungi concentration. Conclusions: The results of this study show that some housing and living characteristics may affect the development and increase of airborne fungi. In addition, exposure to airborne fungi may be a risk factor for the prevalence of childhood atopic diseases.

Distribution Characteristics of Airborne Fungi in a Partial Area of Seoul City (서울시 일부 지역의 대기 중 부유 진균의 분포 특성)

  • Kim, Ki-Youn;Kim, Dae-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.5
    • /
    • pp.407-414
    • /
    • 2012
  • Objectives: This study was performed to assess based on field investigation the distribution characteristics of airborne fungi in an area of Seongdong-gu, Seoul. Methods: Three sites, a living area, forest and traffic site, were selected for evaluation of monthly level of outdoor airborne fungi. An on-site survey was executed between January 2009 and December 2009. During the experimental period, air sampling was performed every month in the afternoon (2:00 pm-5:00 pm) using a cascade impactor. Results: Outdoor airborne fungi measured in Seoul, Korea over one year showed a concentration range from 850CFU $m^{-3}$ to 15,200CFU $m^{-3}$. The mean respirable fraction of outdoor airborne fungi was 67% compared to total concentration. Regardless of measurement site, there was no significant concentration difference in outdoor airborne fungi between periods of yellow dust and non-yellow dust (p>0.05). There was no significant correlation relationship between outdoor airborne fungi and atmospheric factors such as temperature and relative humidity. The predominant genera of airborne fungi identified were Aspergillus, Cladosporium, Paecilomyces and Penicillium. Conclusion: Monthly levels of outdoor airborne fungi were highest in April and November and lowest in August. In seasonal concentration distribution, the autumn showed the highest level of outdoor airborne fungi, followed by spring, summer and winter. In regional concentration distribution, the highest level of outdoor airborne fungi was generally found in the forest, followed by the living area and traffic site.

The Association of Lead Biomarkers of Lead Workers with Airborne Lead Concentration in Lead Industries (납 사업장의 공기 중 납 농도 및 납 노출 근로자들의 납 관련 생물학적 노출 지표의 관련성에 관한 조사)

  • Kim, Nam-Soo;Kim, Jin-Ho;Jang, Bong-Ki;Kim, Hwa-Sung;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.43-52
    • /
    • 2007
  • This study was designed to investigate the difference of airborne lead concentration by type of lead industries and type of lead exposure and to evaluate their association with lead biomarkers of lead workers in 11 lead using industries. Total of 182 lead workers (male: 167, female: 15) from 11 lead industries were participated for this study from March, 2004 to August, 2005. Airborne lead concentration were measured by representative personal sampling of workers in each unit workplace and applied same concentration value to the workers in the same unit workplace who did not measure their airborne lead with personal air sampling. Tibia lead, blood lead, zinc protoporphyrin in whole blood, ${\delta}$-aminolevulinic acid in urine, hemoglobin and hematocrit were selected as study variables of indices of lead exposure. Information about type of lead exposure (fume or non-fume other), age, work duration, smoking & drinking habit were also collected. Significant differences were seen in the means of zinc protoporphyrin, blood lead and tibia lead in lead workers by different airborne lead concentration in workplace. While blood lead and tibia lead in lead workers were significantly higher in secondary smelting than other types of lead industries, zinc protoporphyrin, ${\delta}$-aminolevulinic acid in urine and airborne lead concentration were significantly higher in litharge manufacturing. While the mean blood lead was significantly higher in the lead workers working in fume type unit workplace than those of non-fume lead workers, the mean airborne lead concentration of fume workers was significantly lower than non-fume lead workers. In the multiple regression analysis of airborne lead concentration and the type of lead exposure on tibia lead and lead exposure indices after adjustment of related covariates, airborne lead concentration was statistically significantly associated with blood lead and tibia lead, but the type of lead exposure was only associated with blood lead. To verify the causal association of airborne lead concentration on blood lead and tibia lead, further studies are needed.

Method Development for Estimating Concentration of Airborne Fungi Using a Thermal Imaging Camera (열화상 카메라를 이용한 공기 중 부유 진균 농도 추정방법 개발에 관한 연구)

  • Kim, Ki Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.465-471
    • /
    • 2015
  • Objectives: An objective of this study is to apply a thermal image camera which shows various color according to temperature of indoor surface for estimating concentration of airborne fungi. Materials and Methods: While wall temperature were monitored by applying the thermal image camera, airborne bacteria as well as air temperature and relative humidity have been measured in lecture room and toilet of university for seven months. Results: Based on the results obtained from this study, the ranges of temperature and airborne fungi concentration were $20{\sim}24^{\circ}C$ and $20{\sim}400cfu/m^3 $ for red image, $17.5{\sim}20^{\circ}C$ and $35{\sim}150cfu/m^3$ for orange image, $15.5{\sim}17.5^{\circ}C$ and $25{\sim}650cfu/m^3$ for sky-blue image, and $13.5{\sim}15.5^{\circ}C$ and $50{\sim}200cfu/m^3$ for blue image, respectively. The color of indoor surface taken shot by thermal image camera showed consistent trend with temperature of indoor surface. There is, however, little correlation between color of indoor surface and airborne fungi concentration(p>0.05). Among environmental factors, relative humidity in indoor air showed a significant relationship with airborne fungi concentration(p<0.05). Conclusions: The more measurement data for proving statistically an association between color of indoor surface and airborne fungi concentration should be provided to easily estimate indoor level of airborne fungi.

Relationship between airborne pollen concentrations and meteorological parameters in Ulsan, Korea

  • Jung, In-Yong;Choi, Kee-Ryong
    • Journal of Ecology and Environment
    • /
    • v.36 no.1
    • /
    • pp.65-71
    • /
    • 2013
  • The concentration of airborne pollen is related to meteorological parameters. The main purpose of this study was to determine the correlation between airborne pollen and meteorological parameters in Ulsan based on sampling from 2010 to 2011. The primary factors of interest were differences in the pollen scattering start date, end date, and peak date, and the fluctuations in pollen concentration. The meteorological parameters that affected the start and peak dates of the pollen season were as follows. For Pinus and Alnus, the dates were correlated with sunshine and an increase in temperature, whereas for Quercus, the dates were correlated with increasing temperature. During the pollen season, Alnus peaked when the temperature was highest and Pinus peaked when the relative humidity was lowest. The concentration of airborne pollen was correlated with meteorological parameters during the sampling period as follows: Pinus, Alnus, and Humulus pollen concentrations were positively correlated with increasing temperature and negatively correlated with rainfall and relative humidity; Humulus pollen concentration was positively correlated with sunshine; and Quercus and Humulus pollen concentrations were positively correlated with wind speed.

Size Distribution and Concentration of Airborne Fungi in the Public Facilities (다중이용시설 내부에 분포하는 부유 진균의 입경별 농도 특성)

  • Park, Jae-Beom;Kim, Ki-Youn;Jang, Gyu-Yeob;Kim, Chin-Yon;Lee, Kyung-Jong
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.36-45
    • /
    • 2006
  • The aim of this study is to examine size-based concentration and genera of airborne fungi distributed in public facilities such as hospital, kindergarten, day-care center and postpartum nurse center and to provide fundamental data in order to prevent respiratory diseases caused by exposure to airborne fungi. Culturable total and respirable concentrations of airborne fungi averaged to $382\;cfu/m^3\;and\;292\;cfu/m^3$ in hospital, $536\;cfu/m^3\;and\;347\;cfu/m^3$ in kindergarten, $334\;cfu/m^3\;and\;266\;cfu/m^3$ in day-care center, and $371\;cfu/m^3\;and\;289\;cfu/m^3$ in postpartum nurse center, respectively. The ratio of respirable to total concentration of airborne fungi in the investigated public facilities was ranged from $55\%\;to\;70\%$ but there was no significant difference among them (p>0.05). The mean I/O ratio of culturable total and respirable concentrations were 0.56 and 0.64 in hospital, 0.72 and 0.91 in kindergarten, 0.33 and 0.45 in day-care center, and 0.63 and 0.73 in postpartum nurse center, respectively. Indoor concentration of airborne fungi did not correlated significantly with indoor temperature and relative humidity (p>0.05) but had a significant positive correlation with $CO_2$ concentration (p<0.01) and surrounding condition (p<0.05). Penicillium spp., Cladosporium spp., and Aspergillus spp. were estimated to over $95\%$ of total airborne fungi identified in the investigated public facilities.

Study of correlation between airborne benzene and urinary trans,trans-muconic acid in Petrochemical industry processes (공기 중 벤젠과 소변 중 뮤콘산과의 상관성 연구)

  • Joo, Kui Don;Lee, Jong Seong;Choi, Seong Bong;Shin, Jae Hoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.356-363
    • /
    • 2006
  • To investigate the exposure effect of benzene, we measured airborne benzene as external doses, uninary tt-muconic acid as an internal dose of benzene exposure and analyzed the relationship between tt-muconic acid concentration and benzene exposure. The study population of eight businesses included 157 workers(87 workers in field; exposure group, 70 workers in board; control group) who produce or use benzene in petrochemical industry. The concentrations of airborne benzene were evaluated by personal samples and urine was sampled at the pre and end shift. Urinary t,t-muconic acid as internal dose was to analyze the relationship with airborne benzene. The geometric means(GM) of airborne benzene was 0.0231 ppm(range ND-1.0471 ppm) in exposure group and 0.0147 ppm(range ND-0.3162 ppm) in control group. The geometric means(GM) of urinary t,t-muconic acid at end-shift was $196.8{\pm}2.23{\mu}g/g$ creatinine in exposure group and $149.2{\pm}2.08{\mu}g/g$ creatinine in control group. There was significant correlation between the airborne concentration of benzene and the urinary concentration of t,t-muconic acid( r=0.711, p<0.01). From the results of stepwise multiple regression analysis about t,t-muconic acid at end-shift, significant independents was airborne benzene. In this study, there were significant correlation between the urinary concentration of t,t-muconic acid and the airborne concentration of benzene. More extensive studies ruling out healthy worker effect is needed.

Comparison of Airborne Nanoparticle Concentrations between Carbon Nanotubes Growth Laboratories based on Containment of CVD (탄소나노튜브 성장 실험실에서 CVD 밀폐 여부에 따른 공기 중 나노입자 농도 비교)

  • Ha, Ju-Hyun;Shin, Yong-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.3
    • /
    • pp.184-191
    • /
    • 2010
  • Although the usage of nanomaterials including carbon nanotubes (CNTs) has increased in various fields, scientific researches on workers' exposures and controls of these materials are very limited. The purpose of this study was to compare the airborne nanoparticles concentrations from two university laboratories conducting experiments of CNTs growth based on containment of thermal chemical vapor deposition (CVD). Airborne nanoparticle concentrations in three metrics (surface area concentration, particle number concentration, and mass concentrations) were measured by task using three direct reading instruments. In a laboratory where CVD was not contained, the surface area concentration, number concentration and mass(PM$_1$) concentration of airborne nanoparticles were 1.5 to 3.5 times higher than those in the other laboratory where CVD was confined. The ratio of PM$_1$ concentration to total suspended particles(TSP) in the laboratory where CVD was not confined was about 4 times higher than that in the other laboratory. This indicates that CVD is a major source of airbone nanoparticles in the CNTs growth laboratories. In conclusion, researchers performing CNTs growth experiments in these laboratories were exposed to airborne nanoparticles levels higher than background levels, and their exposures in a laboratory with the unconfined CVD were higher than those in the other laboratory with the confined CVD. It is recommended that in the CNTs growth laboratories adequate controls including containment of CVD be implemented for minimizing researchers' exposures to airborne nanoparticles.

Distribution properties of seasonal airborne sea salt in the seashore (해안가의 계절별 비래염분량의 분포 특성)

  • Lee, Jong-Suk;Choi, Won-Sung;Moon, Han-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.237-240
    • /
    • 2004
  • When the concrete structures are in contact with seawater, concentration of chloride for estimating chloride diffusion coefficient can be defined as the chloride concentration of sea water. However, in case the concrete structures, constructed in the seashore, aren't directly in contact with seawater, it is difficult to establish the interface concentration of chloride. In addition, marine concrete structures are greatly affected by salt attack such as rebar corrosion, among the cause of salt attack, airborne sea salt is primary factor. Therefore, in this study, salt attack environment by airborne sea salt was investigated in terms of a seasonal distribution at 33 spots, 6 areas in the East, West, South coast for 1 year. Results indicated that in the South coast, the amount of the airborne sea salt is comparatively higher in summer. in the West coast. higher in winter. On the other hand, in the East coast, the amount of the airborne sea salt is rarely affected by a season.

  • PDF