• Title/Summary/Keyword: Airborne bacteria

Search Result 123, Processing Time 0.026 seconds

Dielectrophoretic separator for Airborne Microbes (전기 영동을 이용한 공기 중 미생물 분리)

  • Moon, Hui-Sung;Nam, Yun-Woo;Park, Jae-Chan;Jung, Hyo-Il
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1683-1684
    • /
    • 2008
  • For direct detection of microbes in air, samples have to be collected but environmental particles such as dust are also trapped in such samples. Therefore the isolation of target bacteria from non-biological materials of similar size is of great importance in the identification of such organisms. Dielectrophoresis is an emerging technique that can rapidly separate cells in microfluidics. In this paper we proposed a new method for the separation of airborne microbes using condensation and dielectrophoresis. This system could be used as a continuous flow through separation system for various particles and utilized as a pretreatment technique for microbe detection.

  • PDF

Microbiological Quality Assessment of Kimbap According to Preparation and Cooking Condition and Identification of Critical Control Points in the Processes (김밥 조리조건에 따른 미생물 품질 평가와 중요관리점의 관찰)

  • 김종규
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.2
    • /
    • pp.66-73
    • /
    • 2004
  • This study was performed to assess the microbiological quality of kimbap (rice balls rolled in laver) prepared in two conditions (normal condition or clean, sanitized condition) and to support a practical application to identify critical control points (CCPs) in the preparation and cooking processes of kimbap. Kimbap, raw materials of kimbap, utensils (knives, cutting board, and kimbal which is made of bamboo), and hands of food handlers were examined microbiologically. Airborne microbes in the kitchens were also evaluated. Escherichia coli, Salmonella and Staphylococcus aureus were not detected in all samples. The aerobic bacteria and coliform bacteria levels of all samples in clean, sanitized condition were much lower than those in normal condition. More aerobic bacteria and coliform bacteria were counted in unheated raw materials of kimbap than in heated raw materials. In both conditions, the levels of airborne microbes of the kitchens were satisfactory. The aerobic bacteria and coliform bacteria of kimbap prepared in clean, sanitized condition were one hundredth levels of those of kimbap prepared in normal condition. However, fecal coliforms were detected even in the kimbap prepared in clean, sanitized condition. The results indicate that microbiological contamination of kimbap may be mainly originated from the contaminated unheated raw materials, utensils, and hands of food handlers, and also possible cross-contamination during preparation. The CCPs for kimbap preparation and cooking were handling of unheated raw materials, cleaning and sanitizing utensils, and hand washing of food handlers.

A Study on the Removal Efficiency of Harmful Pollutants in the Cooking Chamber (조리실내의 유해오염물질 제거율에 관한 연구)

  • Kwon, Woo-Taeg;Lee, Woo-Sik
    • Culinary science and hospitality research
    • /
    • v.22 no.8
    • /
    • pp.149-156
    • /
    • 2016
  • The purpose of this study is to reduce the contaminants (total volatile organic compounds (TVOCs), fine particle, odor and total airborne bacteria) during cooking process in cooking chamber, and to decrease the health damage in indoor space that has bad work environment. In order to solve the shortcomings of existing air purifiers and remove all kinds of pollutants effectively, this study focused on the development of indoor air purifiers which are made of bar type. Bio-ceramics filter which combines activated carbon and loess. The air cleaners developed with 4 measuring items including TVOCs, particulate matter, complex odor and total airborne bacteria were measured comparing their pre-service test to their post-service test after a period of time. The measured results showed higher removal efficiency of 91.02% as the concentration of TVOCs was reduced from $2,500{\mu}g/m^3$ to $223{\mu}g/m^3$. Second, the particulate matter removal ratio was 97.51% efficient with average concentration of $26.68{\mu}g/m^3$. Third, the odor showed 95.20% reduction as air dilution ratio averaged out at 144. Last, total airborne bacteria was eliminated by over 94% showing the changeable concentration from $787{\sim}814CFU/m^3$ to $47{\sim}40CFU/m^3$. In addition, the removal rate of harmful pollutants is excellent, and it is expected that the environment of the existing poor cooking room will be greatly improved by using the developed air purifier in combination with the ventilation device and the stove hood.

Seasonal Monitoring of Airborne Microbial Concentrations in Kindergartens (유치원의 실내환경에서 공기중 미생물 수의 계절적 변화)

  • Hwang, Gwang-Hwan;Lee, A-Mi;Sin, Hyeon-Jin;Kim, Jong-Seol
    • Korean Journal of Microbiology
    • /
    • v.39 no.4
    • /
    • pp.253-259
    • /
    • 2003
  • To assess microbiological indoor air quality in kindergartens, concentrations of viable airborne microorganisms were seasonally determined at three kindergartens in Ulsan from April, 2002 to January, 2003. Sampling was performed with an impaction-type air sampler and three different media. The numbers of bacteria grown on Staphylococcus medium were between 84 and 4,150 MPN/m3 with an average of 827 MPN/m3, and those on standard method agar ranged from 50 to 2,636 MPN/m3 with an average of 580 MPN/m3. The bacterial concentrations were highest in summer, followed by fall, spring, and winter, and were significantly correlated with indoor temperature. Among the colonies, 45.6~61.0% were observed as Gram-positive cocci and 8.5~20.6% were Gramnegative rods. Micrococcus species were the dominant organisms. The numbers of fungi ranged from 0 to 1,888 MPN/m3(661 MPN/m3 average) based on colony counts with dichloran rose bengal chloramphenicol agar. On average, the fungal concentrations were highest in summer and lowest in winter. Penicillium species and Aspergillus species were identified from the colonies. The obtained data can be utilized as a step to set a guideline for bioaerosols in indoor environment of schools.

Microbial Metagenome of Airborne Particulate Matter: Methodology, Characteristics, and Influencing Parameters (대기입자상물질의미생물메타게놈: 분석방법, 특성및영향인자)

  • Kang, Sookyung;Cho, Kyung-Suk
    • Microbiology and Biotechnology Letters
    • /
    • v.50 no.2
    • /
    • pp.165-192
    • /
    • 2022
  • The microbial metagenome characteristics of bioaerosols and particulate matter (PM) in the outdoor atmospheric environment and the effects of climate and environmental factors on the metagenome were analyzed. The concentrations of bacteria and fungi in bioaerosols and PM were determined by sampling different regions with different environmental properties. A variety of culture-independent methods were used to analyze the microbial metagenome in aerosols and PM samples. In addition, the effects of meteorological and environmental factors on the diversity and metagenomes of bacteria and fungi were investigated. The survival, growth, and dispersal of the microorganisms in the atmosphere were markedly affected by local weather conditions and the air pollutant concentration. The concentration of airborne microorganisms increased as the temperature increased, but their concentration decreased in summer, due to the effects of high temperatures and strong ultraviolet rays. Humidity and microbial concentration were positively correlated, but when the humidity was too high, the dispersion of airborne microorganisms was inhibited. These comprehensive data on the microbial metagenome in bioaerosols and PM may be used to understand the roles and functions of microorganisms in the atmosphere, and to develop strategies and abatement techniques to address the environmental and public health problems caused by these microorganisms.

A Study of Dominant Microorganisms in Waste Handling Industries (폐기물 취급 업종에서 우점하는 미생물에 대한 평가)

  • Park, Hae Dong;Park, Hyunhee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.84-94
    • /
    • 2013
  • Objectives: The objective of this study is to identify the composition of dominant microorganisms in waste handling industries. Methods: We collected airborne bacteria and fungi by agar plate impaction method in recyclable waste sorting industry, food recycling industry, landfill and incineration. Isolated dominant microorganisms were identified by VITEK system or morphological analysis. Results: We isolated totally 330 microorganisms in the process and outdoor. Bacillus was the most dominant genus in the all industries, and Sphingomonas, Acinetobacter, Staphylococcus, and Proteus was dominant bacterial genus. The dominant genus of fungi was Penicillium, Aspergillus, and Cladosporium in each industries. Enterobacter, Pseudomonas, Klebsiella, and Proteus was identified as the dominant gram negative bacteria. The ratio of bacteria being biosafety levels(class 1 or 2) was 58.3~77.8%. Conclusions: This study has investigated the dominant microorganisms in the waste handling industries. The genus of dominant microorganisms was similar among the industries but the composition was different. We used biosafety levels as qualitative method, but further studies are needed about specific process of qualitative evaluation methods.

Indoor Environment and Human Factors Affecting the Concentrations of Airborne Bacteria (실내공기중의 박테리아 농도에 영향을 미치는 요인 분석)

  • 김창수;신동천;이경원;문지영;양지연
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.381-382
    • /
    • 2001
  • Bioaerosol은 인공적으로 생성되거나, 혹은 자연적으로 발생하는 생물학적 기원(biological origin)을 가진 물질로 정의한다. 실내공기 중에서 이러한 Bioaerosol 발생의 중요한 원인으로는 실외에서 유입되는 경우와 건물의 HVAC 시스템에 의한 경우, 실내에 거주하고 있는 사람이나 동물에 의한 경우가 대표적이다. 특히 이 세 가지 오염원 중에서 실내 거주자와 동물이 가장 중요한 역할을 하는 것으로 보고되고 있다(Pastuszka 등, 2000). (중략)

  • PDF

Development of Source Profiles and Estimation of Source Contribution for Hazardous Air Pollutants by the Principal Component Analysis in Indoor Air

  • Kim, Yoon-Shin;Hong, Seoung-Cheol;Lee, Cheol-Min;Kim, Jong-Cheol;Jeon, Hyung-Jin;Song, Kyoung-Min;Roh, Young-Man
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.254-258
    • /
    • 2005
  • The purpose of this study is to characterize the indoor-outdoor relationship of airborne pollutants and recognize probable sources in inside and outside individual apartments in Seoul metropolitan. Simultaneous air monitoring in inside and outside of the 16 Korean Apartments classified into 2groups: less than 1 year old and more than 4 years old from October, 2004 to February, 2005were sampled f3r airborne pollutants(volatile organic compounds, formaldehyde, respiratory particles, carbon dioxide and bacteria) using the Korean Indoor Air Quality Official Method. The concentrations of $CO_2$, TVOCs, HCHO, bacteria and PM10 in the less than 1 year old apartments were determined to be $773.6{\pm}422.3ppm$, $4,393.8{\pm}2,758.2{\mu}g/m^3$, $98.0{\pm}56.4{\mu}g/m^3$, $254.0{\pm}186.3CFU/m^3$ and $31.7{\pm}14.8{\mu}g/m^3$, respectively, Also, the concentrations of those in the more than 4 years old apartments were determined to be $798.9{\pm}266.5ppm$, $792.7{\pm}398.3{\mu}g/m^3$, $70.0{\pm}30.7{\mu}g/m^3$, $245.6{\pm}122.0CFU/m^3$, $49.7f28.7{\pm}g/m^3$, respectively. The average ratios of the indoor and outdoor concentrations of $CO_2$, TVOCs, HCHO, bacteria and PM10 were 2.2, 3.6, 3.1, 3.9 and 1.4, respectively. These results of this analysis is suggested that $CO_2$, TVOCs, HCHO, bacteria and PM10 in indoor air are both emitted from source within the apartment environment and partly come from outdoor air. With the above considerations in mind, it is suggested that the research for source contribution of indoor air pollutants should be expanded and the detailed interpretation of the results on these needed further study(using principal component analysis(PCA).

  • PDF

Cultural Conditions for Mass Production of Antagonistic Bacillus subtills CAP134 (길항균 Bacillus subtillis CAP134의 대량생산을 위한 배양조건)

  • 박흥섭;조정일
    • Korean Journal of Organic Agriculture
    • /
    • v.5 no.1
    • /
    • pp.87-99
    • /
    • 1996
  • Cultural conditions for mass production of the antagonistic bacteria, Bacillus subtills CAP134 against pathogens causing major airborne diseases to apple tree, effect of temperature, pH, carbon and nitrogen source in the culture broth were investigated. The bacterial growth was most vigorous when the temperature and pH of the culture broth was 30~$35^{\circ}$C, and 7, respectively. As for carbon source, dextrose was best followed in order by dextrose(monosaccharides)>sucrose(disaccharides)$\geq$saccharose(di-saccharides)>starch (polysaccharides). Among different sugars, bacterial growth was favored by in the order of brown, black and white sugars, indicating that the bacterial growth might be promoted by the minor elements presented as impurities in the less purified sugars. As for nitrogen source, organic forms were better to bacterial growth than inorganic forms, that is polypeptone was best followed in order by soy sauce, soybeen milk and inoganic nitrogens. Differences in bacterial growth among different forms of inorganic nitrogen were negligible.

  • PDF

A Study on the Diffusion and Removal of Airborne Microorganism Pollution in Multistoried Apartment by the Multi-Zone Simulation (멀티존 시뮬레이션에 의한 공동주택의 미생물 오염원 확산과 제거에 관한 연구)

  • Hong, Jin-Kwan;Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.291-298
    • /
    • 2007
  • The purpose of this study is to evaluate the efficacy of multizone simulation that enables to grasp of details about microbial contaminant problem in an multistoried apartment. We used actual indoor test data to figure up microbial contaminant level as initial value for the multizone simulation and estimated the various effects of indoor occupant infected with germs such as bacteria and fungus and the performance of air sterilization by using multizone simulation in substitute for infeasible experimental approach. The results show that natural ventilation make ourselves generally useful for removing indoor microbial contaminants. The results also show that the performance of air sterilization reach the maximum in the case of using mechanical ventilation and UVGI air sterilizer. The conclusion is that this multizone simulation is useful tool for actual design method for immune building systems.