• Title/Summary/Keyword: Airborne Survey

Search Result 133, Processing Time 0.025 seconds

Potential Use of Airborne Synthetic Aperture Radar to Monitor Agricultural Land Uses: A Case Study in Thailand

  • Wanpiyarat, V.;Buapradubkul, D.;Chutirattanaphan, S.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.44-46
    • /
    • 2003
  • In 1996, Thailand's participation in the Pacific Rim as a part of NASA's Mission to Planet Earth (MTPE) Program, was titled 'AIRSAR Thailand Project'. In this project the Department of Land Development utilized Topographic SAR (TOPSAR) which had multi-frequencies: C band, L band, and P band with multi-polarization: HH, VV, and HV as well as C band VV DEM. Satellite data such as LANDSAT TM was also utilized for optimal use. Results of AIRSAR image processing including data fusion among difference wavelength bands and polarization revealed the quality of AIRSAR that best suit for detection of agricultural land uses. The HH-L band AIRSAR was proven to be useful to distinguish among crop types when combined with appropriate data. The HH, VV, and HV-P band enhanced surface characteristics of swamp forest and wetland. In addition, TOPSAR has its great advantage for identification of salt farms and shrimp ponds.

  • PDF

Mineral Resources Potential Mapping using GIS-based Data Integration

  • Lee Hong-Jin;Chi Kwang-Hoon;Park Maeng-Eon
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.662-663
    • /
    • 2004
  • In general, mineral resources prospect is performed in several methods including geological survey, geological structure analysis, geochemical exploration, airborne geophysical exploration and remote sensing, but data collected through these methods are usually not integrated for analysis but used separately. Therefore we compared various data integration techniques and generated final mineral resources potentiality map.

  • PDF

Exposure assessment of Polynuclear aromatichydrocarbons(PAHs) for heat treat workers using Metalworking fluids (금속가공유 취급 근로자의 다핵방향족탄화수소 노출 평가)

  • Joo, Kui Don;Kim, Eun A;Choi, Seong Bong;Kim, Myeong Ock
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.71-80
    • /
    • 2007
  • The purpose of this study was to assess the ambient level of Polynuclear aromatic hydrocarbons(PAHs), oil mist of the metalworking fluids(MWFs), especially in heat treat industry and non heat treat industry. And we assessed the relationship of the pattern of exposed PAHs with oil mist during survey day. The study population of heat treat industries contained 98 workers, non-heat treat industry contained 40 workers. Personal samples were taken for ambient monitoring of PAHs and oil mist. PAHs was to analyze the relationship of airborne oil mist. The geometric mean of airborne total PAHs was $3.44{\mu}g/m^3$ in heat treat industry and $0.13{\mu}g/m^3$ in non heat treat industry, Pyrene and Benzo(a)pyrene was detected from heat treat industry and Naphthalene in heat treat industry was significantly detected higher than in non heat treat industry. The geometric mean of airborne oil mist was $0.19{\mu}g/m^3$ in heat treat industry and $0.70{\mu}g/m^3$ in non-heat treat industry. The correlation between oil mist and total PAHs was shown below, total PAHs in workers of non heat treat industry and heat treat industry were not significantly correlated with oil mist

Holistic inversion of frequency-domain airborne electromagnetic data with minimal prior information (최소 사전정보틀 이용한 주파수 영역 항공 전자탐사 자료의 HOLISTIC 역산)

  • Brodie, Ross;Sambridge, Malcolm
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.8-16
    • /
    • 2009
  • The holistic inversion approach for frequency domain airborne electromagnetic data has previously been employed to simultaneously calibrate, process and invert raw frequency-domain data where prior information was available. Analternative formulation has been developed, which is suitable in the case where explicit prior information is not available. It incorporates: a multi-layer vertically-smooth conductivity model; a simplified bias parameterisation; horizontal smoothing with respect to elevation; and cluster computer parallelisation. Without using any prior data, an inversion of 8.0 million data for 3.4 million parameters yields results that are consistent with independently derived calibration parameters, downhole logs and groundwater elevation data. We conclude that the success of the holistic inversion method is not dependent on a sophisticated conceptual model or the direct inclusion of survey-area specific prior information. In addition, acquisition costs could potentially be reduced by employing the holistic approach which largely eliminates the need for high altitude zero-level measurements.

Characterization of Airborne Bioaerosol Concentration in Public Facilities (다중이용시설내 공기중 바이오에어로졸 농도분포 특성에 관한 연구)

  • Lee, Cheol Min;Kim, Yun Sin;Lee, Tae Hyeong;Park, Won Seok;Hong, Seung Cheol
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.215-222
    • /
    • 2004
  • This study was conducted to evaluate the characterization of airborne bioaerosol in public facilities in Seoul. A total of 17 public facilities were investigated from December, 2002 to February, 2003. As results of the survey, the mean concentrations of bacteria and fungi in indoor air of public facilities were $378.08\pm296.33$ CFU/㎥ by RCS and $106.38\pm171.63$ CFU/㎥ and $347.46\pm335.32$ CFU/㎥ and $95.23\pm62.61$ CFU/㎥, by Six-stage cascade air sampler respectively. The mean concentrations of bacteria in indoor air (by ventilation method) were $517.14\pm343.93$ CFU/㎥ of natural ventilation and $215,83\pm100.71$ CFU/㎥ of mechanical ventilation. The mean concentrations of fungi in indoor air (by ventilation method) were $83.14\pm79.16$ CFU/㎥ of natural ventilation and $133.50\pm248.07$ CFU/㎥ of mechanical ventilation. The mean concentrations of bacteria in indoor air were 449.44 CFU/㎥ for the ground and $217.50\pm103.68$ CFU/㎥ for the underground. The mean concentrations of fungi in indoor air were $63.89\pm77.66$ CFU/㎥ for the ground and $202.00\pm290.08$ CFU/㎥ for the underground.

Development of Shoreline Extraction Algorithm using Airborne LiDAR Data (LiDAR 데이터를 이용한 해안선 추출 알고리즘 개발)

  • Wie Gwang-Jae;Jeong Jae-Wook
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.2
    • /
    • pp.209-215
    • /
    • 2006
  • Shoreline changes its shapes and attribution dynamically by natural, unnatural acts and is the most information for country. These shorelines can apply to framework data of MGIS (Marine Geographic Information System), and they are getting important to implement a phase of monitoring around coastal areas. This study proposed an algorithm automatically extracting shorelines to use a new developed LiDAR (Light Detection And Ranging) data which is applying in ocean and coastal areas. Then, in result, it was compared to shorelines which is derived from ground survey. In result, it shows stable shorelines in various coast areas such as nature, artificial coast. Additionally, and a possibility of shoreline extraction through LiDAR data.

An Investigation on Concentration of Airborne Microbes in a Hospital (병원내 공기중 미생물의 농도에 관한 조사연구)

  • 최종태;김윤신
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 1993
  • A survey was conducted to measure concentration of airborne microbe in a hospital using RSC air sampler during October~November 1991.The result was as follows: 1) In an agar strip GK-A media for total counts of microbial particles. The highest count were 1384 CFU/m$^3$ in the main lobby, followed by 912 CFU/m$^3$, in the obstetric room, 688 CFU/m$^3$ in 1CU. By gram staining, the distribution for organisms in the air were shown 74.1% in gram possitive cocci followed by 16.8%, in gram possitive bacilli 6.7% in gram negative bacilli and 4.7% in yeast, but low organism was detected in recovery room with 194 CFU/m$^3$. 2) In agar strip S media for Staphylococci the count at the main lobby was detected in the recovery room with 92 CFU/m$^3$, Tests of coagulase were negative Staphylococci with 78%, and positive Staphylococci with 22%. The Staphylococci were highly resistance to penicillin, ampicillin and sensitive to amikacin, cefazolin, gentamycin and chloramphenicol. 3) In agar strip C media for coliform bacteria the colony counts at the main lobby was 139 CFU/m$^3$ and treatment room was 190 CFU/m$^3$, most frequently isolated microorganisms were non fermentative bacilli. 4) In agar strip HS media for yeast and molds. Most frequently colony counts 17~76 CFU/m$^3$, 0.5% lactophenol cotton blue stains were shown unidentified 77.2%, 8.1%, in Penicillium 8.1% in Aspergillus, and 3.8% in mucor.

  • PDF

A Survey of Characterization Airborne Bio-aerosol Concentration in Public Facilities

  • Kim, Yoon-Shin;Roh, Young-Man;Hong, Seung-Cheol;Lee, Choel-Min;Jun, Hyung-Jin;Kim, Jong-Choel;Song, Min-Kyung
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.273-278
    • /
    • 2005
  • This study was performed to investigate the characteristics of distribution for airborne bio aerosol in 11 public facilities in Seoul from June to July. The collected samples are total suspended bacteria in indoor and outdoor Anderson six stage air sampler by the IAQ standard method of Ministry of Environment in Korea. The concentration of total suspended bacteria in the theater higher than IAQ standards. As the results of the survey, the most high indoor air mean concentration of bacteria $1273CFU/m^3$ was theater and the most high outdoor air mean concentration of bacteria $^229 CFU/m3$was Kindergarten. The mean concentration of bacteria in the theater was higher than the IAQ standards established by the Ministry of Environment, Republic of Korea. Moreover, this study was for investigation a part of indoor air pollution condition in public facilities. It means that this study can't represent fDr all of public facilities. Therefore, we suggest that long and middle term country plan for management of IAQ should be established through long-term and continuous investigation of IAQ condition. Also above consideration in mind, it is suggest that the research for source contribution of the results on these need further study.

  • PDF

Generation of Large-scale and High-resolution DEMs over Antarctica through a LIDAR survey

  • Lee, Im-Pyeong;Ahn, Yushin;Csatho, Bea;Schenk, Toni;Shin, Sung-Woong;Yoon, Tae-Hun
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1374-1376
    • /
    • 2003
  • NASA, NSF and USGS jointly conducted a LIDAR survey over several sites in the Antarctic Dry Valleys and its vicinity, acquiring numerous surface points by NASA's Airborne Topographic Mapper (ATM) conical laser scanning altimetry system. The data set have high blunder ratio, and the conical scanning pattern resulted large variation of the point densities. Hence, to reduce the undesirable effects due to these characteristics and process the huge number of points with reasonable time and resources, we developed a novel approach to generate large-scale and high-resolution DEMs in robust, efficient and nearly automatic manners. Based on this approach we produced DEMs and then verified them with reference data.

  • PDF

A Survey on the Sanitary Condition of Kitchens of School Lunch Program

  • Kim, Jong-Gyu
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.174-176
    • /
    • 2003
  • A survey was conducted to investigate the sanitary condition of school kitchens in one region of Korea. A self-administered questionnaire recommended by the Korea Ministry of Education & Human Resources Development (MOEHRD) was offered to a random sample of dieticians of twenty-five elementary schools for food, sanitation and safety inspection of their kitchens. Air temperature, relative humidity, and airborne microbes in the kitchens were monitored during food preparation, processing and service. The inspection results showed their sanitary condition met the level B of the recommendation of the Korea MOEHRD. The range of air temperature of the kitchens was 21.4∼22.4$^{\circ}C$, and the range of relative humidity was 62.4∼69.6%. The microbiological evaluation of kitchen samples indicated aerobic plate count levels from 22.5 to 26.5 CFU/15 min. These results indicate that the levels of sanitary condition of kitchens in the schools were not satisfactory for safe foodservice although the inspection showed good results. This study suggests that the school kitchens should be monitored and strict inspection is necessary.

  • PDF