• Title/Summary/Keyword: AirQ+

Search Result 297, Processing Time 0.029 seconds

The effect of inlet air temperature for the cooling of the military electronic chip on the thermal conductive board (공기온도가 열전도성 기판 위에 탑재된 군용 전자칩 냉각에 미치는 영향)

  • 이진호
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.195-206
    • /
    • 2002
  • The conjugate heat transfer from the simulated module in a horizontal channel with the variation of inlet air temperature is experimentally investigated. The aim of this study is to estimate temperature difference between a module and inlet air. This study is performed with the variation of parameters that are inlet air temperature(Ti=25~$55^{\circ}C), thermal resistance( $R_c$=0.05, 4.11, 158 K/W), inlet air velocity(Vi=0.1~1.5m/s), and input power(Q=3, 7 W). The results show that the effect of inlet air temperature is little, at the case of using conductive board. And input power was most effective parameter on the temperature difference between module and Inlet air.

A Study on the Characteristics of Heat Exchanger using Heat Pipe for various Working Condition (운전조건에 따른 히트파이프를 이용한 열교환기의 특성에 관한 연구)

  • Lee, Y.S.;Jang, Y.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.155-165
    • /
    • 1990
  • The purpose of this research is to study the characteristics of heat exchanger using heat pipe under various working conditions by a finite element analysis and experiment. The results are as follows. 1) In this study, h = $Max^B$ is used for the convective heat transfer coefficient and A = 2.761 and B = 0.701 $Mmax^{(-0.0626)}$ were obtained as the results of experiment. 2) For several different working conditions, (Q/Qb) is predicted by varying the values of L/Lt and Re/Rc. The maximum value of (Q/Qb) is achieved when Re/Rc = 1 and Le/Lc = 0.5. 3) The comparison between calculated value and experimental data showed agreement within 5% error. Therefore the method may be used to predict the performance of heat exchanger using heat pipe for similar geometric conditions. 4) For Re/Re/Rc of 0.2-0.3, the minimum thermal resistance exists when Le/Lt is 0.4-0.65.

  • PDF

The Study about Cooling Effect of a Heated module in a Horizontal Channel with a Variation of Channel Height (수평채널 밑면에 부착된 단일 발열모듈에서 채널높이의 변화에 따른 냉각특성 연구)

  • 이진호;유갑종;장준영;김병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.348-355
    • /
    • 2001
  • The coupled conduction and convection heat transfer from a protruding heated module in a horizontal channel with a variation of channel height is experimentally investigated. The input power to the module is 3, 7W and thermal resistance of module support is 0.06 , 1.03 and 158K/W. the Reynolds number ranged from 350 to 4500 corresponding to the inlet velocity(0.4~1.3 m/s) and channel height(11~35 mm). The results were obtained that the decrease of thermal resistance of module support reduces the module temperature by redistributing the heat flux and the overall thermal resistance of the module. In the study the effect of channel height is very significant in the adiabatic condition, but negligible in the conjugate condition. Finally, correlations for Nusselt number and $Q_B$/Q with a variation of Reynolds number were developed respectively.

  • PDF

Development of an Interior Permanent Magnet Synchronous Motor and Drive for 42V Electric Air-conditioner System in Vehicles (42V 전동식 에어컨 시스템용 영구자석 매입형 동기 전동기 및 드라이버 개발)

  • Lee ji-Young;Hong Jung-Pyo;Lee Geun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.6
    • /
    • pp.269-277
    • /
    • 2005
  • In this paper, designs of an Interior Permanent Magnet Synchronous Motor (IPMSM) and its motor driver for 42V automotive air condition system are introduced. The characteristics of the IPMSM are predicted by using d-q equivalent circuit having the parameters, such as current phase angle, d-q axis inductances, core loss resistance, etc. The experimental and analysis results of the prototype are compared to show validity of the analysis method, and to give analyzed characteristics in detail. As the result, an improved IPMSM is designed to widen the operating speed limit of prototype; a cost effective AC drive are considered at the same time.

A Comparative Study for Odor Control Regulations (악취관리제도의 국가간 비교연구)

  • 양성봉;김석만
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.79-87
    • /
    • 2000
  • This study analyzed the regulations concerning odor management or control in Korea, Japan, and developed countries such as USA and Germany. The Korean restriction standards and measurement methods for offensive odor substances are very similar to the Japanese standards and methods promulgated in 1976. Japan promulgated the odor control act and the specific measurement methods of the offensive odor substances in 1973. In Japan, currently, the local governments can establish their own odor restriction areas and proclaim their own standards suitable for their situations. Also, Japan has more strict regulations and more offensive odor substances to be monitored than Korea. The restriction standards of odor in German is quite similar to the permissible limits and standards of air pollutants at emission sources in Korea. Many states in USA are adopting their own restriction standards and measurement methods, e.q., the ambient air pollution standards, organic functionstest methods by dilation, and establishment and addition of air pollution control equipment at emission sources. Finally, this study analyzed the problems of the regulations, standards, and measurement methods concerning the Korean offensive odor management. Since the direct organic fuctions measurement(DOFMM) method is depending upon the personal sensitives of odor substances, the measurement odor value can be equivocal. That is, the odor measurement value by an examines can differ from that by the other examines. Also, there can be conflicts with the measured odor values depending upon the applied measurement methods, e.q., the DOFMM, the dilation method, and the instrumental analysis method.

  • PDF

Digital Twin and Visual Object Tracking using Deep Reinforcement Learning (심층 강화학습을 이용한 디지털트윈 및 시각적 객체 추적)

  • Park, Jin Hyeok;Farkhodov, Khurshedjon;Choi, Piljoo;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.2
    • /
    • pp.145-156
    • /
    • 2022
  • Nowadays, the complexity of object tracking models among hardware applications has become a more in-demand duty to complete in various indeterminable environment tracking situations with multifunctional algorithm skills. In this paper, we propose a virtual city environment using AirSim (Aerial Informatics and Robotics Simulation - AirSim, CityEnvironment) and use the DQN (Deep Q-Learning) model of deep reinforcement learning model in the virtual environment. The proposed object tracking DQN network observes the environment using a deep reinforcement learning model that receives continuous images taken by a virtual environment simulation system as input to control the operation of a virtual drone. The deep reinforcement learning model is pre-trained using various existing continuous image sets. Since the existing various continuous image sets are image data of real environments and objects, it is implemented in 3D to track virtual environments and moving objects in them.

Thermal Decomposition Characteristics of Azo compounds (아조(Azo)화합물 열분해특성)

  • Kim, Kwan-Eung
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.39-44
    • /
    • 2002
  • This study was investigated the thermal decomposition characteristics of azo type sponge blowing agent azodicarbonamide(ADCA) using differential scanning calorimeter(DSC). The experimental results showed that the exothermic onset $temperatures(T_{o})$ for ADCA were about $201{\sim}206^{\circ}C$ and evolution heats(Q) were about $144{\sim}150cal/g$. The exothermic onset $temperatures(T_{o})$, exothermic maximum $temperature(T_{m})$ and exothermic final $temperature(T_{f})$ were decreased by decreasing particle size of ADCA and evolution heats(Q) were increased with it. $T_{o}$ and Q for $6.1{\sim}7.2{\mu}m$ ADCA were increased by increasing heating rate at constant sample weight and activation energy was about 37.29kcal/mol. A positive gas pressure was employed in the elucidation of the decomposition behavior of ADCA because it sublimes during linear heating at atmospheric pressure. $T_{o}$ and Q of ADCA tended to increase with a pressure in air or nitrogen. In the case of azo dye, experimental results showed that $T_{o}$ were about $280{\sim}420^{\circ}C$ and Q were about $2{\sim}30cal/g$.

A Study on the Heat Flux Meter Location for the Performance Test of a Refrigerator Vacuum Insulation Panel (냉장고 진공단열재 성능진단을 위한 열유속계 위치에 관한 연구)

  • Ha, Ji Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.471-476
    • /
    • 2013
  • The present study has been carried out to elucidate the optimal method for the performance test of a refrigerator vacuum insulation panel (VIP), by using numerical heat transfer analysis. Three locations of heat flux meter have been tested, for deriving the best test method to clarify the normal or the abnormal condition of the vacuum insulation panel in a refrigerator. The first location of the heat flux sensor is at the same place as the heater, the second one is at the nearby side location of the heater and the third one is at the opposite side location of heater in the refrigerator. The heat flux and $1/q^{{\prime}{\prime}^2}$ or $q^{{\prime}{\prime}^4}$ were calculated for the cases with the normal VIP, and with the abnormal VIP, and their differences analyzed. From the present study, the first and the second method had a mere difference characteristics of heat flux and $1/q^{{\prime}{\prime}^2}$ or $q^{{\prime}{\prime}^4}$, between the cases with the normal or the abnormal VIP. The magnitude of the heat flux after 300sec had a great difference between the cases with the normal or abnormal VIP for the third method, and it could be considered the most optimal method to test the performance of a refrigerator vacuum insulation panel.

Improved Heat Transfer Coefficient in Heat Exchanger by the Use of Specialized Heating Surface (전열면의 특수표면화에 의한 열기기의 효율향상에 관하여)

  • Yim, Chang-Soon
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.8 no.3
    • /
    • pp.131-150
    • /
    • 1979
  • Recently only a few correlations between various factors due to the different grades of surface roughness for the nucleate pool boiling have been proposed. The main purpose of this work is to test the validity of these types of correlations between related factors to nucleate pool boiling phenomena. The boiling experiments using distilled water were carried out at the heat flux ranging from $7.4\times10^4\;to\;2.4\times10^5kcal/m^2h$ on the sintered porous metal surface with the cavity diameter of 10, n, 40, 70, $100{\mu}$, respectively, at the atmospheric pressure, To determine the bubble sizes, number of nucleation sites, delay and growth time, frequency of bubble emission and rising velocities of bubbles, the high speed motion picture technique was employed. In the correlation $f{\propto}D_b^n$, where f denotes frequency of bubble emission and $D_b$ departure diameter, n, the power factor of $D_b$, have been found to be from -2 to -10/3. The correlation C in the correlation between heat flux q and density of nucleation sites $\frac{N}{A}$, $q=C(\frac{N}{A})^n$, was appeared to be more crucial than the power factor n. The correlation of the heat flux q to the temperature difference ${\Delta}T$ and the density of nucleation sites$\frac{N}{A}$, was proposed to be $$q-460{\Delta}T^{\frac{5}{4}}=K{\Delta}T{\frac{5}{3}}(\frac{N}{A})^{\frac{2}{3}}$$. The values of heat transfer coefficient obtained in this experiments for the porous sintered metal surface appeared to be very high in comparison with the formerly obtained results for the other surfaces.

  • PDF

Chamber to Chamber Variations of a Cylindrical Ionization Chamber for the Calibration of an $^{192}Ir$ Brachytherapy Source Based on an Absorbed Dose to Water Standards (물흡수선량 표준에 기반한 $^{192}Ir$ 근접치료 선원 교정 시 원통형 이온함의 이온함 간 변화)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Kim, Chan-Hyeong;Min, Chul-Hee;Shin, Dong-Oh;Choi, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.7-13
    • /
    • 2009
  • This work is for the preliminary study for the calibration of an $^{192}Ir$ brachytherapy source based on an absorbed dose to water standards. In order to calibrate brachytherapy sources based on absorbed dose to water standards using a clyndirical ionization chamber, the beam quality correction factor $k_{Q,Q_0}$ is needed. In this study $k_{Q,Q_0}s$ were determined by both Monte carlo simulation and semiexperimental methods because of the realistic difficulties to use primary standards to measure an absolute dose at a specified distance. The 5 different serial numbers of the PTW30013 chamber type were selected for this study. While chamber to chamber variations ran up to maximum 4.0% with the generic $k^{gen}_{Q,Q_0}$, the chamber to chamber variations were within a maximum deviation of 0.5% with the individual $k^{ind}_{Q,Q_0}$. The results show why and how important ionization chambers must be calibrated individually for the calibration of $^{192}Ir$ brachytherapy sources based on absorbed dose to water standards. We hope that in the near future users will be able to calibrate the brachytherapy sources in terms of an absorbed dose to water, the quantity of interest in the treatment, instead of an air kerma strength just as the calibration in the high energy photon and electron beam.

  • PDF