• Title/Summary/Keyword: Air-to-air heat exchanger

Search Result 971, Processing Time 0.035 seconds

500Ps급 상용차량 디젤엔진을 이용한 선박용 디젤엔진 개발 연구 (A Study for Development of a Marine Diesel Engine from a 500Ps Commercial Vehicle Diesel Engine)

  • 심한섭
    • 한국기계가공학회지
    • /
    • 제12권6호
    • /
    • pp.125-131
    • /
    • 2013
  • This study was carried out to develop a diesel engine for marine propulsion. This marine diesel engine was developed based on a 500Ps vehicle diesel engine. Many main parts, such as the intercooler, radiator, and engine controller were designed for the marine diesel engine. The intercooler was designed to be of sea water cooling type; inlet air is cooled by sea water. Engine coolant is cooled by sea water in the radiator too. The water cooling heat exchanger has high cooling performance. In the cooling system, consists of the intercooler and the radiator, the sea water passes through the intercooler and then the radiator, in sequence. This process is very effective compared to the reverse method in which sea water passes through the radiator and then the intercooler, in sequence. The control performance of the engine controller and the fuel injection rate were improved using an engine speed controller. This system was tested on an engine dynamometer and an exhaust gas analyzer using the marine diesel engine test method. Test results show that the 500Ps marine diesel engine satisfied the IMO NOx regulations; Tier II.

Performance evaluation of bubble pump used on solar water heating system

  • Xuesong, Li;Park, Gi-Tae;Kim, Pil-Hwan;Chung, Han-Shik;Jeong, Hyo-Min
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.416-422
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and their relationship with the solar radiation intensity. The theory analysis of design bubble pump has been given and the experiment result analysis has been included in the paper.

  • PDF

이중효용 흡수식 냉온수기 동특성 모델 개발 및 실험결과 비교 (Development of a Dynamic Model for Double-Effect LiBr-$H_2O$ Absorption Chillers and Comparison with Experimental Data.)

  • 신영기;서정아;조현욱;남상철;정진희
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.109-114
    • /
    • 2008
  • A dynamic model has been developed to simulate dynamic operation of a real double-effect absorption chiller. Dynamic behavior of working fluids in main components was modeled in first-order nonlinear differential equations based on heat and mass balances. Mass transport mechanisms among the main components were modeled by valve throttling, 'U' tube overflow and solution sub-cooling. The nonlinear dynamic equations coupled with the subroutines to calculate thermodynamic properties of working fluids were solved by a numerical method. The dynamic performance of the model was compared with the test data of a commercial medium chiller. The model showed a good agreement with the test data except for the first 5,000 seconds during which different flow rates of the weak solution caused some discrepancy. It was found that the chiller dynamics is governed by the inlet temperatures of the cooling water and the chilled water when the heat input to the chiller is relatively constant.

  • PDF

전산유동해석을 통한 화장로의 에너지 효율개선 및 실증연구 (Energy Efficiency Improvement and Field Scale Study of Crematory using Computation Fluid Dynamics)

  • 원용태;이승목
    • 공업화학
    • /
    • 제30권1호
    • /
    • pp.95-101
    • /
    • 2019
  • 한국의 2016년 화장률은 82.7%로 1994년의 20.5%보다 4배나 높았다. 화장률이 점차 증가함에 따라 화장시설이 부족해지면서 화장률이 높아질수록 화장시설의 증설이 요구되고 있으며, 또한 화장로의 장기간 작동에 따라 많은 양의 연료가 사용되고 있다. 이러한 문제를 해결하기 위해 본 연구에서는 화장로의 열효율 특성을 최적화하고, 증가하는 화장에 대한 요구에 대응하는 화장 시스템을 제안한다. 본 논문의 목적은 전산 유체 역학(computational fluid dynamics, CFD)을 사용하여 시뮬레이션을 수행함으로써 열전달 계수를 포함한 열흐름 특성을 조사하는 것이다. CFD 모델은 화장시설에 대한 현장 실험으로 검증되었다. 시뮬레이션 결과, 주 연소기에서 연료 소비가 거의 25% 감소하고 체류 시간이 증가했다. 시뮬레이션을 토대로 개량된 연소기, 열교환기, 2차 연소 공기 시스템, 내화 및 단열재를 사용하여 개선된 화장로를 구성하였다. 현장실험 결과 에너지 소비가 약 54.4%로 줄어들었으며 연소 시간이 거의 20 min 단축되었다.

태양열을 이용한 일이중 겸용 흡수식 냉온수기 동적성능 모사연구 (A Study of Dynamic Simulation of a Hybrid Absorption Chiller Utilizing Solar Power)

  • 신영기;서정아;우성민;김효상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.967-972
    • /
    • 2009
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism were modeled. And solar radiation and the solar collector also were also modeled along with its control design. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the issues of the excessive circulation flowrate and the mismatch between available solar power and cooling load discourages the use of the single mode, but the dual use of gas and solar power is recommendable in view of controllability and enhanced COP.

  • PDF

열적으로 성충화된 횡단류에 분류된 제트의 난류확산 거동 (II) (Turbulent Dispersion Behavior of a Jet issued into Thermally Stratified Cross Flows (II))

  • 김상기;김경천
    • 대한기계학회논문집B
    • /
    • 제23권11호
    • /
    • pp.1434-1443
    • /
    • 1999
  • The turbulent fluctuations of temperature and two components of velocity have been measured with hot- and cold-wires in the Thermally Stratified Wind Tunnel(TSWT). Using the fin-tube heat exchanger type heaters and the neural network control algorithm, both stable ($dT/dz=109.4^{\circ}C$) and unstable ($dT/dz=-49.1^{\circ}C$) stratifications were realized. An ambient air jet was issued normally into the cross flow($U_{\infty}=1.0 m/s$) from a round nozzle(d = 6 mm) flushed at the bottom waII of the wind tunnel with the velocity ratio of $5.8(U_{jet}/U_{\infty})$. The characteristics of turbulent dispersion in the cross flow jet are found to change drastically depending on the thermal stratification. Especially, in the unstable condition, the vertical velocity fluctuation increases very rapidly at downstream of jet. The fluctuation velocity spectra and velocity-temperature cospectra along the jet centerline were obtained and compared. In the case of stable stratification, the heat flux cospectra changes Its sign from a certain point at the far field because of the restratification phenomenon. It is inferred that the main reason in the difference between the vertical heat fluxes is caused by the different length scales of the large eddy motions. The turbulent kinetic energy and scalar dissipation rates were estimated using partially non-isotropic and isotropic turbulent approximation. In the unstable case, the turbulent energy dissipation decreases more rapidly with the downstream distance than in the stable case.

4톤급 지게차 냉각홴 소음 저감에 관한 실험적 연구 (An Experimental Study on the Noise Reduction of Cooling Fans for Four-ton Forklift Machines)

  • 최대식;김석우;염태영;이승배
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2021
  • This paper presents research on methods for the reduction of forklifts' noise level for the increased comfort and safety of its operator. A cooling fan with a high air volume flow rate installed in the forklift acts as an important design parameter which efficiently cools the heat exchanger system, helping to transfer internal heat from the engine room to the outdoors with both transmitted and diffracted opening noises. The cooling fan contributes significantly to both the forklift's emitted sound power and the operator room's noise level, thereby necessitating research on the forklift's reduction of acoustic power level and transmission. A noise analysis for various fan models with a biomimetic design based on eagle-wing geometry was conducted. In addition to the acoustic power generation, the aerodynamic performance of the cooling blade is also strongly influenced by the design of airfoil distribution, thereby requiring optimization. The cooling fans were fabricated and installed in the forklift in order to check the efficacy of the forklift engine's cooling, and the final version of the fan was measured for its ability to lower acoustic power level and cool the engine room. This study explains the aerodynamic and acoustic features of the designed fans with the use of BEM analysis and forklift test results.

사이클 해석을 통한 GHP 성능 예측 (Prediction of GHP Performance Using Cycle Analysis)

  • 차우호;최송;정백영;김병순;전시문
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권1호
    • /
    • pp.15-21
    • /
    • 2015
  • 가스 엔진 히트 펌프는 가스 엔진의 축동력으로 압축기를 구동하는 시스템으로 전력을 거의 사용하지 않고, 엔진 폐열을 활용하기 때문에 하절기와 동절기에 전력 Peak 를 억제하는 공조기로 주목을 받고 있는 제품이다. 제품 개발 시 시스템 성능 예측이 중요하므로 이를 위해 초기 설정한 운전점에서 열교환기 및 압축기의 특성을 반영하여 반복 계산을 수행하면 최종적인 운전점을 도출할 수 있고, 가스 엔진의 성능 데이터를 활용하면 가스 엔진 히트 펌프의 정확한 효율을 예측할 수 있다. 난방 성능을 예측할 때에는 엔진 폐열이 시스템에 공급되기 때문에 외부 열을 흡입하는 구간과 엔진 폐열을 흡입하는 구간을 동시에 고려해야 예측의 정확도를 높일 수 있다. 25 마력 가스 엔진 히트 펌프의 성능을 예측한 값은 실제 측정한 값과 비교하였을 경우 5% 정도의 오차가 발생하며 향후 성능 예측 모델을 구성되는 부품 특성을 반영하면 오차의 폭이 감소될 것으로 예상된다.

LNG 연소 및 스팀생산을 위한 3 MWth 급 매체순환연소 시스템의 기본설계 및 민감도 분석 (Basic Design and Sensitivity Analysis of 3 MWth Chemical Looping Combustion System for LNG Combustion and Steam Generation)

  • 류호정;남형석;황병욱;김하나;원유섭;김대욱;김동원;이규화;백점인
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.374-387
    • /
    • 2021
  • Basic design of 3 MWth chemical looping combustion system for LNG combustion and steam generation was conducted based on the mass and energy balance and the previous reactivity test results of oxygen carrier particles. Process configuration including fast fluidized bed (air reactor), loop seal and bubbling fluidized bed (fuel reactor) was confirmed and their dimensions were determined by mass balance. Then, the external fluidized bed heat exchanger (FBHE) was adopted based on the energy balance to extract heat from the system. The optimum reactor design and operating condition was confirmed with sensitivity analysis by modifying system configuration based on the mass and energy balance.

휨 변경 최소화 근접 냉각 금형을 통한 고성능 고효율 플라스틱 축류팬 개발 (Development of high performance and efficiency plastic axial fan by proximity cooling mold to minimize warpage)

  • 신광호;김미애;채보혜;박상옥;김용대
    • Design & Manufacturing
    • /
    • 제13권1호
    • /
    • pp.61-67
    • /
    • 2019
  • The cooling unit of the industrial showcase consists of a compressor, a condenser and an evaporator. An axial fan is used to circulate the air to improve the efficiency of the heat exchanger. In the past, aluminum fans have been used, which have problems such as low performance, efficiency, high failure rate, and high noise. This study is to develop high performance, high efficiency plastic fan replacing aluminum fan. A major factor in determining the performance and noise of an axial fan is the angle and cross-sectional shape of the blade, which is suitable for raising the lift force, thereby controlling the vortex, which is the main cause of noise and performance degradation. In order to produce a high efficiency injection molded fan, it is necessary to develop a mold that minimizes the deformation of the injection process for the designed shape. In this study, we developed a high efficiency, low noise plastic injection fan with more than 11% performance improvement and noise reduction compared to conventional aluminum fan.