장력 감김으로 부착된 가로방향 휜-미니채널의 공기측 열전달 특성 (Air Side Heat Transfer Charactieristics of Tension Wound Transverse Fin with Minichannel)

  • 김종수;임용빈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.701-706
    • /
    • 2005
  • Pipes, tubes. and tubular sections with external transverse high fins have been used extensively for heating cooling, and degumidifying air and other gases. This work was performed to investigate an air side heat transfer charactieristics of minichannel with tension wound transverse fin. This estimate was confirmed conversion heat capacity the air side surface area enlargement and heat transfer charactieristics performed available inlet tube side hot water mass flux or outlet tube side air frontal air velocity. The most suitable tension wound transverse finned minichannel was measured extremely low in air side pressure drop and fin effectiveness $3.3\~4.4$. The pressure drop $0.9\~2.8Pa$ was ranged frontal air velocity $0.5\~1.2m/s$. It is also appeared that heat transfer in air side could be better conversion heat area which has been increased $330\%$ of heat capacity compared with the bare tube.

열전모듈을 이용한 에어컨의 방열부 냉각특성에 대한 연구 (Cooling Characteristics at Hot Side of the Thermoelectric Module for an Air Conditioner)

  • 김서영;강병하;장혁재;김석현
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.214-220
    • /
    • 2002
  • A small air conditioner using thermoelectric module has been designed and built. Three types of cooling methods, such as air cooling, closed-loop water cooling, and evaporative cooling, for hot side of thermoelectric module have been investigated. Among three types of cooling method, the evaporative cooling method is seen to be the most effective to achieve the steady state operation of a thermoelectric air conditioner The system performance with evaporative cooling method are also studied in detail for several oprating parameters, such as input power to the thermoelectric module, water or air flow rate at the hot side, and air flow rate at the cold side. The results obtained indicate that the cooling capacity of a system is increased with an increase in the input power to the thermoelectric module while the system COP is decreased. It is also found that the optimal air flow rate as well as water flow rate at the hot side is needed for the best system performance at a liven operating condition. Both the system COP and cooling capacity are increased as the air flow rate at cold side is increased.

데이터센터의 외기도입 냉방시스템 적용에 따른 경제성 평가 (Economic Evaluation of Air-side Economizer System for Data Center)

  • 박성현;서장후
    • 설비공학논문집
    • /
    • 제26권4호
    • /
    • pp.145-150
    • /
    • 2014
  • Many studies are being conducted with the aim of reducing the energy consumption in data centers, which are one of the highest consumers of energy. The use of an air-side economizer system that uses external air during intermediate and winter seasons is being considered for reducing the energy consumption of air conditioners. In this study, using the energy simulation, we evaluated the energy performance of a central chilled water cooling system and air-side economizer system in domestic data centers. Further, the cost-effectiveness of the air-side economizer was analyzed through Life-Cycle Cost Analysis. The results showed that with the use of air-side economizer systems, the energy costs increased as the applied filter grade increased; however, unlike existing central chilled water systems, it would break even within 2 years.

Impact of Air-side Economizer Control Considering Air Quality Index on Variable Air Volume System Performance

  • Cho, Sang-Hyeon;Park, Joon-Young;Jeong, Jae-Weon
    • 국제초고층학회논문집
    • /
    • 제6권1호
    • /
    • pp.101-111
    • /
    • 2017
  • The objective of this study is to determine the effectiveness of a modified air-side economizer in improving indoor air quality (IAQ). An air-side economizer, which uses all outdoor air for cooling, affects the building's IAQ depending on the outside air quality and can significantly affect the occupants' health, leading to respiratory and heart disease. The Air Quality Index (AQI), developed by the US Environmental Protection Agency (US EPA), measures air contaminants that adversely affect human beings: PM10, PM2.5, SO2, NO2, O3, and CO. In this study, AQI is applied as a control for the operation of an air-side economizer. The simulation is analyzed, comparing the results between the differential enthalpy economizer and AQI-modified economizer. The results confirm that an AQI-modified economizer has a positive effect on IAQ. Compared to the operating differential enthalpy economizer, energy increase in an operating AQI-modified economizer is 0.65% in Shanghai and 0.8% in Seoul.

증발기의 설계조건에서 공기측 열전달계수 및 압력강하 산출 (Evaluation of Air-side Heat Transfer and Friction Characteristics on Design Conditions of Evaporator)

  • 김창덕;이진호
    • 설비공학논문집
    • /
    • 제15권12호
    • /
    • pp.1007-1017
    • /
    • 2003
  • An experimental study on the air-side pressure drop and heat transfer coefficient of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side heat transfer coefficients in the literature is not based on a consistent approach. This paper focuses on new method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry and wet surface heat transfer estimation in fin-tube heat exchanger having refrigerant on the tube-side. Results are presented as plots of friction f-factor and Colburn j -factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of 150∼250 kg/$m^2$s with air flows at velocity ranges from 0.3 m/s to 0.8 m/s.

응축기의 설계조건에서 공기측 열전달계수 및 압력강하 산출 (Evaluation of Air-side Heat Transfer and Friction Characteristics on Design Conditions of Condenser)

  • 김창덕;전창덕;이진호
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.220-229
    • /
    • 2003
  • An experimental study on the air-side pressure drop and heat transfer coefficient of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side heat transfer coefficients in the literature is not based on a consistent approach. This paper focuses on new method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry surface heat transfer estimation in fin-tube heat exchanger having refrigerant on the tube-side. Results are presented as plots of friction f-factor and Colburn j -factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of 150~250 kg/$m^2$s with air flows at velocity ranges from 0.6 m/s to 1.6 m/s.

외기 온도 변화가 핀-관 열교환기의 공기측 열전달계수와 마찰계수에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of the Air Temperature on the Air-Side Heat-Transfer Coefficient and the Friction Factor of a Fin-and-Tube Heat Exchanger)

  • 김내현;조홍기
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.149-158
    • /
    • 2017
  • In general, the air-side j and f factors of evaporators or condensers are obtained through single-design tests performed under air-dry and wet-bulb temperatures. Considering that the indoor or outdoor air temperatures vary significantly during the operation of an air conditioner, it is necessary to confirm that the experimentally-obtained j and f factors are widely applicable under variable air conditions. In this study, a series of tests were conducted on a two-row slit-finned heat exchanger to confirm the applicability. The results showed that, for the dry-surface condition, the changes of the tube-side water temperature, water-flow rate, and air temperature had virtually no effect on the air-side j and f factors. For the wet condition, however, the f factor was significantly affected by these changes; contrarily, the j factor is relatively independent regarding this change. The formulation of the possible reasoning is in consideration of the condensation behavior underneath the tube. The wet-surface j and f factors are larger than those of the dry surface, with a larger amount for the f factor.

층류 확산화염에서의 매연과 질소산화물의 배출특성 : 공기측/연료측 희석제 첨가에 따른 영향 (Soot and NOx Emissions in Laminar Diffusion Flames: Effects of Air-Side versus Fuel-Side Diluent Addition)

  • 이종호;엄재호;박철웅;전충환;장영준
    • 대한기계학회논문집B
    • /
    • 제27권5호
    • /
    • pp.596-603
    • /
    • 2003
  • Present study has been conducted to see the relative effects of adding N: to fuel-side and air-side on flame structure, soot formation and NOx emissions. Experiments were carried out to ascertain to what degree chemical kinetics and/or molecular transport effects can explain the differences in soot formation and NOx emission by studying laminar diffusion flames. Direct photograph was taken to see the flame structure. CARS techniques was used to get the flame temperature profiles. And spatial distribution of soot could be obtained by PLII method. CHEMKIN code was also used to estimate the global residence time to predict NOx emissions at each condition. Results from these studies indicate that fuel-side dilution is more effective than air-side dilution in view of NOx emissions. However, air-side dilution shows greater effectiveness over fuel-side dilution in soot formation. And turbulent mixing and heat transfer problems were thought to be considered in practical applications.

자동차 사이드미러의 유동 해석을 통한 융합연구 (A Convergence Study through Flow Analysis of Automotive Side Mirror)

  • 오범석;조재웅
    • 한국융합학회논문지
    • /
    • 제10권9호
    • /
    • pp.161-166
    • /
    • 2019
  • 본 연구에서는 A, B, C 3가지 자동차 사이드미러 모델들에 있어서의 공기 저항으로 인한 유동을 분석을 함으로서 다양한 사이드미러들 주위에서의 흐름을 연구한다. 모델 A는 사각형 모양의 사이드미러이고, 모델 B는 삼각형 모양의 사이드미러, 모델 C은 타원형 모양의 사이드미러이다. 자동차의 사이드미러의 설계를 변경함으로서 운전 시 좀 더 사이드미러의 공기저항을 줄여서 약간의 자동차의 동력을 감소시킬 수 있다. 해석 결과로서, 사이드미러에 대한 공기저항의 압력이 클수록 공기 유동속도가 큰 것을 볼 수 있었다. 그러므로 공기저항의 압력이 작을수록 유동속도가 작고 공기가 더 잘 유통된다고 판단된다. 그러므로 Model B가 가장 좋은 Model이라는 것을 확인할 수 있다. 본 연구결과를 토대로 얻은 자동차 사이드 미러의 설계데이터를 활용함으로서 실생활에서의 자동차 운전시에 그 미적 감각을 나타낼 수 있다.

고층건물 풍상면과 풍하면의 기온차 (A Study on Air Temperature Difference between Windward and Leeward Side at High-rise Buildings)

  • 김일;최화;어금항;구희영;정해연;김문성;이규석
    • 한국환경복원기술학회지
    • /
    • 제15권1호
    • /
    • pp.63-71
    • /
    • 2012
  • To investigate the air temperature difference between windward and leeward side at high-rise building area, the air temperature and relative humidity data were observed for 10 minute interval from July 9, 2011 to November 30, 2011. The observed data were compared, analyzed and examined to illustrate air temperature between windward side (H Apartment) and Leeward side (W Apartment). The diurnal and seasonal variation of air temperature difference between windward and leeward site were also investigated. After the analysis, the overheat of windward side by $0.4^{\circ}C$ irrespective short distance of two observation positions. It was also lower than those of surrounding air temperature observing stations. It is mainly due to the air temperature decreasing effects of leeward side of high rise buildings.