국내 표준계사의 냉난방부하 특성 연구 (A Study on the Characteristics of Heating and Cooling Loads of Standard Chicken Houses in South Korea)

  • 권영철
    • 대한건축학회논문집:구조계
    • /
    • 제35권10호
    • /
    • pp.235-243
    • /
    • 2019
  • In South Korea, millions of poultry have died due to repeated heat waves every year. The purpose of this study is to analyze the characteristics of heating and cooling loads of chicken houses in Korea and to present an effective insulation and ventilation measures to minimize the damage of poultry due to summer heat wave and to save energy in chicken houses in winter. The heating and cooling loads of standard chicken house were calculated. As a result of the calculation of maximum heating load based on the minimum ventilation rate in winter, the outdoor air temperature requiring heating was $6{\sim}7^{\circ}C$ to keep the indoor air temperature of chicken houses as $24^{\circ}C$. The peak cooling load of chicken houses was mostly taken by the heat generated by chickens and the heat gain due to ventilation. The heat gain through building envelopes was as small as neglectable. Most of chicken houses is usually cooled by gigantic forced ventilation in summer in Korea. When the chicken houses are cooled by electric cooling machine such as cooler or air conditioner, it is more effective to keep minimum ventilation rate to reduce the maximum cooling load. To lower the temperature of supplying water to cooling pad, it is recommended to use the underground water below 10 meters from the ground if there is abundant underground water.

파형 단면을 가진 유하식 집열기의 열적 성능에 대한 이론 및 실험 연구(I) (An Analytical & experimental study on the thermal performance of trickle solar collector with Sinuous Cross-section)

  • 이종호;정모;백남춘;오정무
    • 대한설비공학회지:설비저널
    • /
    • 제12권4호
    • /
    • pp.240-251
    • /
    • 1983
  • The municipal government of Daejeon, Korea set up a plan to retrofit solar energy to the existing swimming pool. The pool was constructed in 1980, and meets the requirements of International standard. It will be used for the 1986 Asian Games and the 1988 Seoul Olymipics. The roof structure of the existing pool is to be modified to accomodate trickle solar collectors. In addition, various energy conserving ideas will be applied to the existing building structure. For the prevention of over heating of collectors on the roof, natural air convection scheme will be adopted within the collector system. Natural convection of passive type heating would be also adopted for the space heating of the pool when the system is idle. At present, the pool can be utilized only for two months a year without auxilairy heating. With oil heating, the energy cost would be too high for the normal operation. When this project completed in March 1984, it would be expected to be openable for seven months a year without a significan amount of auxiliary heating. In this project, two dimensional numerical analysis technic have been used to analyse the characterisitics of thermal performance of the swimming pool system. An experimental tat verification of the theoretical analysis have been also attempted.

  • PDF

지역난방 아파트에 대한 난방에너지 실측 및 시뮬레이션 (Measurement and Simulation of Heating Energy for Apartments with District Heating)

  • 이은주;이두영;홍희기;김영균
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.572-578
    • /
    • 2014
  • Heating energy was measured in an apartment housing unit with a district heating system, varying the kind of hot water distributors. Ondol coils passing through a living room raised the temperature of the room where the heating was turned off. Including this characteristic of Ondol heating into the modeling, we performed simulations and showed a verification by comparison with the results of measurements. As a result, a main flow control method, which changes hot water flow rate supplied to a housing unit according to the thermal load, can reduce the supplied flow rate and lower the return temperature, compared with a constant flow method. That can result in decreased heat loss in utility-pipe conduits even though the heating energy supplied is almost the same. An outdoor reset control that raises the temperature of the supplied hot water if the outdoor temperature falls has the effect of a quicker response in heating than the reduced flow rate and return temperature.

실내공기질을 고려한 공동주택의 하이브리드 환기 시스템의 운영에 관한 연구 (A Study on the Operational Strategy for Hybrid Ventilation System in Apartment unit focused on Indoor Air Quality)

  • 이용준;이승복;이경회
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.203-210
    • /
    • 2004
  • This dissertation identifies and investigates the possible control modes of hybrid ventilation system in applying to general apartments. It evaluates range of hybrid ventilation control modes in terms of indoor air quality, thermal comfort, and energy consumption in a living room and a kitchen of the $1000m^2$ apartment. The TRNSYS simulation program was used for evaluating the following four ventilation types : A ventilation mode relying on only infiltration for supplying air, A natural ventilation mode considering with weather condition, A hybrid ventilation (natural + mechanical ventilation) mode allowing minimum ventilation with no heat exchange, and a hybrid ventilation mode with heat exchange. This study shows the following results. As temperature being controlled by heating cooling equipments, there is without significant difference in thermal performance among ventilation types. Regarding Indoor Air quality, Indoor air contamination level of the hybrid ventilation case consistently keep the lower levels. The hybrid ventilation modes consume more energy by a 49% as compared to the A ventilation mode relying on only infiltration for supplying air. It is caused by the continuous ventilation for keeping good indoor air quality; the increase of energy consumption can be attributable to the increase of the heating energy. Therefore, the heat exchange between indoor and outdoor air is required during heating season in severe weather conditions. During the cooling seasons, Introducing natural ventilation can achieve energy saving by 40 ~ 45%. Thus, it can be an effective strategies for energy saving. Based on these results, a hybrid ventilation system can be suggested as an effective ventilation strategy for archiving high level of indoor air quality, thermal comfort, and energy consumption.

전기자동차의 난방용 면상 후막히터의 제조방법과 성능에 관한 실험적 연구 (An Experimental Study on the Manufacturing Method and Performance of Planar Thick Film Heaters for Electric Vehicle Heating)

  • 이채열;임종한;이재욱;박상희
    • 한국산업융합학회 논문집
    • /
    • 제27권3호
    • /
    • pp.685-692
    • /
    • 2024
  • Currently used heating elements are metal and non-metal heating elements, including various types of heaters, and resistance line heating elements have a problem of decreasing thermal efficiency over time, so to solve this problem, a planar heating element using high-purity carbon materials and oxidation-resistant inorganic compounds was applied. Through the manufacture of planar heating elements using CNT, ruthenium composite materials, and ruthenium oxide, physicochemical performance and capacity were increased, and instantaneous responsiveness was increased. Through thick film technology applicable to various base bodies, fine patterns were formed by the screening method in consideration of the fact that the performance of the heat source depends on the viscosity and pattern shape. The heating element was manufactured by thick film printing technology by mixing ruthenium oxide, CNT, Ag, etc. The characteristics of each paste were analyzed through viscosity measurement, and STS 430 was used as a base. Surface temperature and efficiency were measured by testing heaters manufactured for small wind tunnels and real-vehicle experiments. The surface temperature decreased as the air volume increased, and the optimal system boundary was found to be about 200 mm. Among the currently used heating elements, this paper manufactured a planar heating element using thick film technology to find out the relationship between air volume and temperature, and to study the surface temperature.

실내수영장의 에너지 소비요소별 에너지 절약효과에 관한 연구 (A Study on the Energy Conservation Effect of Each Energy Consumption Component In Indoor Swimming Pools)

  • 김영돈;권규동;여명석;김광우
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1092-1101
    • /
    • 2002
  • The objective of this study is to develop energy saving strategies for indoor swimming pools and to estimate the effect of each energy saving strategy. For this purpose, field measurements regarding pool water heating energy, domestic hot water heating energy are conducted and a base energy consumption model is implemented using the DOE-2.1E program. The results of the study reveal that 25% of the total pool water heating energy may be saved by using night time pool covers, 27% of the total domestic hot water heating energy may be saved by using a waste water heat recovery system (effic. 60%), and of the total ventilation energy may be saved using an exhaust air heat recovery system (effic. 60%).

냉각 파일런 분사를 이용한 스크램제트 연소기 내 혼합증대 (Mixing Augmentation with Cooled Pylon Injection in Scramjet Combustor)

  • 이상현
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.594-597
    • /
    • 2009
  • The mixing characteristics of pylon injection in a Scramjet combustor and effects of film cooling to protect pylon from air-heating. Three-dimensional Navier-Stokes equations with $k-{\omega}$ SST turbulence model were used. Fuel hydrogen and air were considered as coolants. There were remarkable improvements of penetration and mixing rate with the pylon injection. There also over-heating on the front surface of pylon without film cooling. The coolant injected parallel to the front surface of the pylon protect the pylon from over-heating.

  • PDF

대형 Community 건물의 연료전지 구동 복합열원 하이브리드 히트펌프 냉.난방 시스템 성능 해석 (The Study on the Performance of the Fuel Cell Driven Compound Source Hybrid Heat Pump Heating and Cooling System to Large Community Building)

  • 변재기;정동화;최영돈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.82-87
    • /
    • 2007
  • In the present study, the simulation on the annual performance evaluation of a renewable energy systems with fuel cell driven compound source hybrid heat pump systems is applied to the heating and cooling of large community building. The large community building has the economical advantage to apply heat pump cooling and heating systems the long period operation. If air and ground source hybrid heat pump systems are combined, COP of the system can be increased largely. Fuel cell driven compound source hybrid heat pump system can reduced the fuel cost as well as thermal storage tank sharply.

  • PDF

숙박업소 건물의 히트펌프 냉난방 시스템 적용을 위한 시뮬레이션 연구 (Study on the Simulation of Heat Pump Heating and Cooling Systems to Resident Building)

  • 최영돈;한성호;조성환;김주성;엄철준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.915-920
    • /
    • 2006
  • Recently available heat pump system by using air heat-source is not efficient. Because the mean temperature of korean winter season is low, economy of air heat-source heat pump descend, and COP is below 3.0. This paper was practiced the simulation on evaluation criteria for heat pump heating and cooling systems to resident building. As a result, heating and cooling composition heat pump system apply to the building needed to be provided heat source for 24 hours.

  • PDF

A Study on the Distortion Caused by Spot Heating with Air Cooling

  • Shin S. B.;Youn J. G.
    • International Journal of Korean Welding Society
    • /
    • 제5권1호
    • /
    • pp.35-43
    • /
    • 2005
  • This paper deals with the optimum condition for spot heating to correct the thin buckled panel caused by welding. Heat input models for each flame torch tip (500, 800, 2000) with standoff were establish using FEA to evaluate the temperature distribution of the heated plate and verified by experiment. With the heat input models developed for each torch tip, the effect of heating variables including ramp ratio(R) and standoff on the radial shrinkage and angular distortion was identified using FEA. Based on the results, the proper conditions of spot heating with air cooling were established. The amount and distribution of the radial shrinkage by spot heating were formulated as the function of heating variables and in-plane rigidity of the plate.

  • PDF