• 제목/요약/키워드: Air-guide

검색결과 291건 처리시간 0.027초

평면형 구조와 Halbach 자석배열 선형모터를 이용한 리니어 XY 스테이지의 설계 (Design of Linear XY Stage using Planar Configuration and Linear Motors with Halbach Magnet Array)

  • 김기현;이문구
    • 한국생산제조학회지
    • /
    • 제19권4호
    • /
    • pp.553-561
    • /
    • 2010
  • In flat panel display or semiconductor industries, they install the equipments with fine line width and high throughput for fabrication and inspection. The equipments are required to have the linear stage which can position the work-piece with high speed, fine resolution on wide range of motion. In this paper, a precision planar linear XY stage is proposed. The stage has a symmetric planar window configuration and is guided by air-bearings on granite plate. The symmetric planar window configuration makes the stage has robustness against dynamic and thermal disturbances. The air-bearings let the stage move smooth on straight guide bar and flat granite surface. The stage is actuated by linear motor with Halbach magnet array (HMA). HMA generates more confined magnetic flux than conventional array. The linear motors are optimized by using sequential quadratic programming (SQP) with the several constraints that are thermal dissipation, required power, force ripple and so on. The planar linear XY stage with the symmetric planar configuration and the linear motors is implemented and then the performance such as force ripple, resolution and stroke are evaluated.

자동차 Defrost 노즐 유동의 설계인자에 대한 수치적 연구 (Numerical Study of the Design Factors for Flow Analysis of the Automotive Defrost Nozzle)

  • 박원규;배인호
    • 한국자동차공학회논문집
    • /
    • 제11권1호
    • /
    • pp.217-224
    • /
    • 2003
  • The frost and mist in the windshield disturb the sight of driver and passengers especially in winter. This possibly leads to safety problems. In order to export automobiles to the countries of North America, the safety regulation requires the frost of selected area should be completely melted in 30 minutes. The defrost pattern and time for melting of frost are fully dependent on the flow and temperature field near the windshield. Furthermore, the flow and temperature field near the windshield are dependent on the air discharged from defrost nozzle. The present work has been done for understanding the flow features of the discharged air and internal flow within the nozzle duct. The three dimensional Navier-Stokes code was used for performing the generic A/C duct flow analysis. The present results were nearly coincided with experimental data. To perform the parametric study of the effectiveness of the number of guide vanes, the discharge angle and the location of nozzle were changed. The ratio of volume flow rate through defrost nozzle and side exit were compared to investigate the influence of parameters on the effectiveness of defrost nozzle. The velocity profiles and flow patterns of the defrost nozzle duct were also analyzed.

신재생에너지 설비 설계방안 개발 및 시뮬레이션 사례 연구 (Development of a Renewable Energy Facility Design and Its Simulation Case Study)

  • 신영기;김은주;김태형
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.464-470
    • /
    • 2013
  • Economic feasibility was conducted regarding the regulation that dictates obligatory installation of renewable energy facilities in small proportion. A concern is how to allocate the capacities of candidate facilities (solar collectors, PV cells and geothermal heat pumps) with minimum cost, and meet the obligatory energy supply proportion. A design rule has been developed, with which a designer can tune his or her design strategy between installation cost and LCC. This was derived mainly from documents regarding the KEMCO installation guide. It was concluded that PV was the cheapest, with respect to installation cost, but a geothermal heat pump was the most recommended, when LCC was also taken into account. The proposed design result was also confirmed, by simulation results obtained from Energy Plus.

굴절률 기반 토양 수분 센서 (Refractive index-based soil moisture sensor)

  • 심은선;화수빈;장익훈;나준희;김민회
    • 센서학회지
    • /
    • 제30권6호
    • /
    • pp.415-419
    • /
    • 2021
  • We developed a highly accurate, yet inexpensive, refractive index (RI)-based soil moisture sensor. To detect the RI, a light guide was set with a light-emitting diode and photodiode. When the air fills the space between the soil particles, most of the incident light is reflected at the interface between the waveguide and the air because of the large RI difference. As the moisture of the soil increases, the macroscopic soil RI increases. This allows incident light to pass through the interface. The intensity of the light reaching the photodiode was simulated according to the change in the soil RI. Using the simulation results, we designed and manufactured a curved glass waveguide. We evaluated the performance of the RI-based soil sensor by comparing it with a commercially available, high-cost and high-performance time-domain reflectometer (TDR). Our sensor was 96% accurate, surpassing the costly TDR sensor.

Research on the Coupling Coordination Relationship between Regional Information Technology Level and Economic Development

  • Li, Jin-yang;kim, Hyung-Ho;Yang, Jun-Won
    • International journal of advanced smart convergence
    • /
    • 제11권2호
    • /
    • pp.153-162
    • /
    • 2022
  • The impact of the information technology industry on economic development is becoming increasingly important. In this study, we take China's provincial-level regions from 2015 to 2020 as the research object, comprehensively evaluates the level of their information technology systems by the entropy weight method, and then measures the coupling coordination relationship between the information technology system and the economic development system by the coupling coordination degree model. As a result, we found that the income of the information technology industry, the investment of talents and science research have the most important influence on the level of the information technology system. During the research period, with increasing values, the coupling degree of the two systems was at a high level. Affected by development strategies, diffusion effects and industrial relocation, the coupling degree in the central and western regions has shown a rapid growth trend. The coordination degree of the two systems is relatively low, and 83.9% of the provinces are in the medium-low coordination stage. The information technology industry has obviously promoted economic development. Besides, relevant policies should be introduced to effectively support and guide the high-quality development of the information technology industry and promote the high-level coordinated development of the two systems.

병영시설의 태양열급탕시스템에 관한 연구 (A Study on the Solar Water Heating System in the Military Facilities)

  • 김두천;서진석
    • 대한설비공학회지:설비저널
    • /
    • 제11권4호
    • /
    • pp.6-18
    • /
    • 1982
  • The performance of two typical types of solar hot water heating system was tested in Seoul. Types of systems studied are single-tank internal external heat exchanger system and single-tank internal heat exchanger system. Comparing to experimental results, a transient system simulation program was made to analyze the performance of the selected system. The climate data, Standard Weather Year for Seoul, required for the simulation was provided. Computer simulations were used to estimate the effect of significant parameters upon system performance. The followings are obtained. 1. In the domestic solar water Heating system, the value $20-40kg/m^2\;h$ for flow rate through the collector is much better than the recommended value $72kg/m^2\;h$ in the solar heating system. 2. The effectiveness of collector heat exchanger and storage tank size are found to have only a small effect upon system performance. 3. The hot water draw pattern has a significant effect on system performance. A higher system efficiency achieved when draw-off occurred around noon than when it occurred around early morning. Using the above results, the reference solar hot water system which provides $300\ell$ of hot water per day, was selected as a guide for designer. And simplified graphical method was developed based on the modified f-chart method to determine required collector area. When the system design parameters of the proposed system differs from the reference system, required collector area can be calculated from area adjustment factors.

  • PDF

원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구 (A Study on Construction and Application of Nuclear Grade ESF ACS Simulator)

  • 이숙경;김광신;손순환;송규민;이계우;박정서;홍순준;강선행
    • 방사성폐기물학회지
    • /
    • 제8권4호
    • /
    • pp.319-327
    • /
    • 2010
  • 공학적 안전설비 공기정화계통과 관련된 실험 수행을 위해 원자력등급 ESF 공기정화계통 시뮬레이터를 설계, 제작, 검증하였다. 영광 5,6호기 주제어실 공기정화계통의 공급자 정보, 도면 등을 기준으로 실사를 통해 치수를 확인하여 3D CAD 모델을 작성하였다. 모델과 현장 계통의 실측 유량을 기준으로 CFD 분석을 수행하였다. 공기정화계통으로 유입되는 공기는 $30^{\circ}C$, 유동형태는 균일한 것으로 가정하고, 검사 기록지에 의한 주제어실 ESF 공기정화계통의 유량이 12,986 CFM이고, $610{\times}610mm^2$의 HEPA 필터가 9개 설치되어 있으므로 HEPA 필터 단면를 지나는 유속은 1.83 m/s이다. 주제어실 공기정화계통 모델링시 공기 유동이 흐르지 않는 필터 테두리 지지대를 고려하여 현장과 유사한 유동현상을 모사하였다. 약 8 m/s로 기록된 활성탄 흡착기 하단의 공기유동은 별도의 분석을 통해 7 m/s 이상의 유속이 모사되도록 CFD 분석하였다. 연료건물 비상배기계통 및 비상노심냉각계통 기기실 배기정화계통의 공기정화계통에 대해서도 CFD 분석한 결과, 시뮬레이터의 유속을 조절하면 세가지 ESF 공기정화계통을 모두 모사할 수 있음을 확인하였다. CFD 분석 후 시뮬레이터를 원자력등급으로 제작하였고, 본 실험에 착수하기 전에 공기유동 분포도실험을 통해 시뮬레이터의 신뢰도를 검증하였다. 검증결과 중급 필터를 장착한 상태에서 시뮬레이터의 필터 지지대 부분을 제외한 내부에서 공기유동이 고르게 분포함을 확인하였고, 제작된 시뮬레이터는 Reg. Guide 1.52(Rev.3) 개정 내용 확인을 위한 실험에 사용되었다.

터널구간 운행시 KTX HVAC-여압장치 작동에 따른 $CO_2$와 PM10 변화연구 (A Study on $CO_2$ and PM10 Changes by Operation of KTX HVAC-Pressurization Equipment in Tunnel Sections)

  • 소진섭;유성연
    • 한국철도학회논문집
    • /
    • 제10권6호
    • /
    • pp.723-729
    • /
    • 2007
  • 환경부는 2006년 12월에 ${\ulcorner}$대중교통수단 실내공기질 관리 가이드라인${\lrcorner}$을 마련하였다. 관리항목으로 이산화탄소$(CO_2)$와 미세먼지(PM10)에 대해 각각 Level 1(평상시)과 Level 2(혼잡시)고 가이드라인을 제시하였다. 이에 따라 현재는 법적 기준이 아니지만, 열차와 전동차에 대해 실내공기질 관리가 필요하게 되었다. KTX는 터널 진입시 발생하는 고압의 압력파로 인한 이명현상을 방지하기 위해 여압장치가 설치되어 있다. 외부 신선공기는 플랩의 작동에 의해 공기 순환이 이루어진다. 본 연구는 2008년까지 진행되고 있는 코레일 기본연구과제로, 2006년 7월에 KTX가 운행하는 경부선(서울-부산)과 호남선(용산-목포)을 대상으로 실내공기청정도를 측정하였다. 터널구간에서 KTX 여압장치 작동에 따른 실내공기질 변화를 측정하고, KTX ATESS 레코더 기록파일과 비교 분석하였다. 측정결과 미세먼지 농도는 환경부 가이드라인에 매우 양호하였고, 이산화탄소 농도는 터널 일부구간으로 옥산-오탄, 고등-휴대, 개착-일직 터널에서 변화가 있지만, KTX 객실 공기청정도는 환경부에서 제시하고 있는 가이드라인에 만족한 수준으로 나타났다.

New Cooling System Design of BLDC Motor for Electric Vehicle Using Computation Fluid Dynamics Modeling

  • Vu, Duc Thuan;Hwang, Pyung
    • Tribology and Lubricants
    • /
    • 제29권5호
    • /
    • pp.318-323
    • /
    • 2013
  • Overheating in electrical motors results in detrimental effects such as degradation of the insulation materials, demagnetization of magnets, increases in Joule losses, and decreases in motor efficiency and lifetime. Thus, it is important to find ways to dissipate heat from the motor and to keep the motor operating at its most efficient temperature. In this study, a new design to guide air flow through a given brushless direct current (BLDC) motor is developed and the design is analyzed, specifically by using computational fluid dynamics (CFD) simulations. The results showed that the temperature distribution in the three proposed models is lower than that in the original model, although the speed of the cooling fan in the original model reaches a very high value of $15{\times}10^3$ rpm. The results also showed that CFD can be effectively used to simulate the heat transfer of BLDC motors.

Twist Friction Driver의 이송특성에 관한 연구 (A Study on the Feed Characteristics of Twist Friction Driver)

  • 정준휘;이응석;안동율
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.934-939
    • /
    • 2004
  • This paper propose a study on the Feed Characteristics of Twist Friction Driver. We are using Twist Friction Driving mechanism system. The system consists of Twist Friction Driver elements such as driving shaft, driven roller, Spring for pre-load, Air bearing guide, Servo motor, and measuring devices such as Encoder of Servo motor, Laser interferometer, LVDT . The Twist Friction driver is mechanically simple and very quiet at high speed, and has low pre-load. So The Twist Friction driver can materialize an ultra precision feed-resolution. The feed characteristics of the driver is determined by slip and angular error, backlash.

  • PDF