• Title/Summary/Keyword: Air-guide

Search Result 291, Processing Time 0.029 seconds

Effects of Baffle Location on the Performance of a Super Compact Condenser in an Automotive Air Conditioning System (자동차용 에어컨의 고밀도 응축기(SCC)에서 배플의 위치 변화에 따른 성능향상에 관한 연구)

  • 이명재;박복춘;백병준;염동석;한창섭
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.128-140
    • /
    • 1997
  • A new super compact condenser(SCC), which has been developed recently is especially suitable for an alternative refrigerant HFC-134a due to its high performance and compactness. The SCC is composed of two pipe headers, baffles, narrow multi-rectangular channels, and louvered fin arrays. Alternating inlet and outlet by the inserted baffles in pipe headers guide refrigerant to and from the narrow multi-rectangular channels. Since the flow rate and its lengh are changed depending on the number and location of baffles, the corresponding pressure drop and heat transfer rate are changed. The present study aims to theoretically and experimentally investigate the effects of baffle location and its number on the pressure drop and thermal performance of the SCC with 40 multi-rectangular channels. The results show that the present method provides an acceptable prediction of pressure drop and heat transfer rate for a 4 pass SCC. However, the model significantly under predicts the performance of a 3 pass SCC, which may be attributed to the phase separation of refrigerant flowing through header pipes. Pressure drop is more signifi- cantly influenced than heat transfer rate by the baffle location.

  • PDF

Improvement of Uncertainty for Gravimetric Flow Calibrator (10톤 용량의 중량식 교정장치에 대한 불확도 개선)

  • Lee, Dong-Keun;Park, Joo-Young;Lee, Haeng-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1042-1046
    • /
    • 2008
  • Both the weighing bridge and the diverter system is a important component in achieving a high accuracy liquid flow rate standard using a static gravimetric method. The weighing bridge is a tank which weighing collected flow with a load cells. The diverter is a moving device used to direct flow alternately along its normal course(by pass) or towards the weighing tank. The time needed for collection into the weighing tank is measured using a timer. So it is important to the diversion period is sufficiently fast and triggering point of timer which is determined the filling time. On this studies show that the measurement deviation of load cell and uncertainty of diverter system for changing diversion speed and triggering point was estimated in accordance with Guide to The Expression of Uncertainty in Measurement(ISO).

  • PDF

A Study on the Improvement of Assessment Criteria through Green Building Certification Cases for Apartment Houses (공동주택 친환경건축물인증 사례를 통한 평가항목 개선안 연구)

  • Kim, Myoung-Shin;Hwang, Jae-Woo;Park, Kyung-Soon;Son, Won-Tug
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.563-568
    • /
    • 2008
  • The Green Building Certification is issued through self-assessment of applicant, assessment of assessment members and deliberation committee members. These assessments are carried out based on a standard provided Ministry of land transport and maritime affairs and environment. However, opinion difference of assessment standards could be occurred due to diversity of understanding for a standard or subjectivity of committee member. In this paper, We discussed the primary cause of score difference after analyzed assessment standard for the site, transportation, energy and resources, ecological environment, indoor environment in five different Apartment Houses located in Seoul. At a result, score difference was at least 3 points in each section except indoor environment and total score difference of housing complex is by 10 points. To improve these problems, educational program should be activated and guide for assessment standard should be published.

  • PDF

A Study on a Concept and Basic Design of a Small-Scaled LSM for Ultra-High Speed Railway Transit (초고속열차용 축소모델 선형동기전동기의 개념 및 기본설계 연구)

  • Park, Chan-Bae;Lee, Hyung-Woo;Lee, Byung-Song;Park, Hyun-June
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.905-911
    • /
    • 2009
  • The viscosity drive method by the wheel which is widely used in the conventional railway systems needs a large friction force between the wheel and the guide-rail, which brings on a thrust force for a quick acceleration and a high-speed travelling. In addition, the viscosity drive method needs an increase of the vehicle weight for a large friction force. However, a maglev train is possible to be driven by the electro-magnet instead of the wheel, which produces a levitation and thrust force without any contact. In general, low-speed maglev train uses a linear induction motor(LIM) for propulsion that is operated under 300[km/h] due to the power-collecting and end-effect problems of LIM. In case of high-speed maglev train, a linear synchronous motor(LSM) is more suitable than LIM because of a high-efficiency and high-output properties. LSM has a driving principle as same as a conventional rotary synchronous motor(RSM), and the torque of RSM becomes the thrust force of LSM. A conventional LSM has relatively large air-gap compared with a conventional RSM. So, it must be achieved a design that is considered normal force by finite-asymmetric structure, end-effect on the entry and exit part, and support structure of a moving part. Therefore, in this research, authors accomplish a conceptualizing and basic design of a small-scaled LSM, and characteristics analysis using FEM.

  • PDF

Optimization of Membrane Separation System for Carbon Dioxide Recovery from Combustion Gases (연소기체로부터 이산화탄소 회수를 위한 막 분리 공정의 최적화)

  • Han, Myungwan;Kim, Miyoung;Kim, Beom-Sik
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.222-229
    • /
    • 2005
  • Five stage enriching membrane system for separating combustion gas (air 90%, $CO_2$ 10%) was proposed and simulated by using Aspen plus and Excel. The system recovers 90% $CO_2$ of the combustion gas and the purity of $CO_2$ recovered was more than 99%. Optimization yields a reduction in membrane area as well as operating and capital cost. Retentate concentration and permeate pressure of each stage were chosen as optimization variables. By analyzing the optimization results, we derived several design guide lines for the enriching membrane system.

A study on the Mathematical Tension Model for a Non-contact Transfer of a Moving Web in R2R e-Printing Systems (롤투롤 시스템에서의 비 접촉 이송 시스템을 위한 수학적 장력 모델에 관한 연구)

  • Lee, Chang-Woo;Kim, Ho-Joon;Kang, Hyun-Kyoo;Shin, Kee-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.9
    • /
    • pp.894-898
    • /
    • 2009
  • In a post printing section of roll to roll printing systems, scratch problem is the major defects. The functional qualities such as conductivity, mobility could deteriorate because of the scratch defect. In general, the scratch of the printed pattern on the flexible substrate was induced from a contact between rolls and printed pattern in the post printing section. In this paper, for non-contacting transfer of a moving web, a mathematical tension model has been developed considering strain due to air floatation and the proposed mode has been validated by numerical simulation. Additionally, the correlation between floatation height and speed compensation to control the tension and register are investigated. On the basis of the proposed model, a guide line of speed control in R2R printing system is presented to guarantee the non-contact between rolls and R2R printed pattern on the flexible substrate.

Developing the framework of level diagnosis for green data center (그린데이터센터의 수준진단 프레임워크 개발)

  • Ra, Jong-Hei;Lee, Sang-Hak
    • Journal of Digital Convergence
    • /
    • v.9 no.2
    • /
    • pp.141-152
    • /
    • 2011
  • The data center has become an increasingly important part of most business operations. An increasing demand for computation has led to increasing industry energy consumption. Therefore, higher-than-normal rates of energy efficiency have become a core issue in the life cycle of data center. In this paper, we proposed the framework of level diagnosis for green data centre that can be used to diagnose the levels of capability maturity model. This framework contains the 5 key areas such as construction, air-conditioning, electricity, information technology, organization and indicators that can be applied as basic level diagnosis guide for green data center.

Analysis and Design of a Magnetic Levitation Rail using the Repulsive Force of Permanent Magnets (영구자석의 반발력을 이용한 자기부상레일의 해석 및 설계)

  • 이강원;송창섭
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.1
    • /
    • pp.48-54
    • /
    • 1999
  • For the high speed linear motor and the transportation device at clean room, a magnetic levitation rail without contact using the repulsive force of permanent magnets was newly developed. The characteristics of repulsive and lateral forces of the magnetic levitating system using permanent magnet was studied and the devised magnetic levitating system was evaluated by analytical and experimental approaches. This system is composed of two fixed guide rails with the rare earth permanent magnet array and a moving unit which is attached two magnet pairs at each sides. Because this system was forcedly levitated by the face to face repulsive forces, levitating air gap length can be repulsive force of an auxiliary magnetic repulsion system on the center of moving unit.

  • PDF

A Systematic Categorization of Interior Environmental Design Elements for Improving Sustainability - With Particular Reference to Unit Plan Design Elements of High-rise Apartment - (지속가능한 실내환경디자인 요소의 체계적 분류 - 초고층 아파트 단위 주공간의 디자인요소를 중심으로 -)

  • Lee Eun-Jung;Park Young-Ki
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.3 s.56
    • /
    • pp.48-55
    • /
    • 2006
  • A sustainable building must produce an interior environment that is safe, healthy, comfortable and supportive of human performance and well-being. The medical human comfort: performance and productivity cost of unhealthy environment may cause much cost for healing. Research that buildings with daylight, fresh air, eco-materials and sustainable interior design are consistently rated as more comfortable and occupants performance, satisfaction and health. This study is to categorize systematically interior environmental design elements for improving sustainability with a view to developing an evaluation model of super high-rise apartment unit plans. With a literature survey and design guide lines concerning sustainable design elements, three hierarchical categorization levels of human, environment, energy and resources systems that consists of upper, middle, low design elements have been proposed. A total of 6 items have been suggested for middle level of categorization and 24 items for lower level. Finally a total of 107 design elements concerning the 24 items and their relationahips have been revealed. The needs for a systematic approach to interior environmental design for sustainability have been discussed.

Experimental Study on the Surface Pressure Characteristics of a Rear-Guider for the Various Design Factors of a Cross-Flow Fan (관류홴의 설계인자 변화에 따른 리어가이더의 표면압력 특성에 관한 실험적 연구)

  • Kim, J.K.
    • Journal of Power System Engineering
    • /
    • v.9 no.3
    • /
    • pp.50-57
    • /
    • 2005
  • A cross-flow fan is strongly influenced by the various design factors of a rear-guider and a stabilizer. The purpose of this paper is to investigate the effects of a rear-guider and a stabilizer on the surface pressure of a rear-guider in an indoor room air-conditioner using a cross-flow fan. The design factors considered in this paper are a rear-guider clearance, a stabilizer clearance, and a stabilizer setup angle, respectively. The operating condition of a cross-flow fan was controlled by changing the static pressure and flowrate using a fan tester. All surface pressures of a rear-guider are differently distributed according to the stabilizer setup angle, and show a zero value in the flow coefficient, ${\Phi}{\fallingdotseq}0.5$ only of a stabilizer setup angle, $45^{\circ}$. Especially, they show a big negative value in the expansion angle larger than $34^{\circ}$ regardless of a rear-guider clearance, a stabilizer clearance, and a stabilizer setup angle. On the other hand, surface pressures for various stabilizer cutoff clearances are better than those for various rear-guider clearances.

  • PDF