• 제목/요약/키워드: Air-flow volume

검색결과 608건 처리시간 0.026초

A Study on the Characteristics of Two-Phase Flow by Driven Bubbles in a Liquid Bath

  • Oh, Yool-Kwon;Seo, Dong-Pyo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권1호
    • /
    • pp.44-50
    • /
    • 2005
  • In the present study, the characteristics of upward bubble flow were experimentally investigated in a liquid bath. An electro-conductivity probe was used to measure local volume fraction and bubble frequency. Since the gas was concentrated at the near the nozzle, the flow parameters were high near the nozzle. In general their axial and radial values tended to decrease with increasing distance. For visualization of flow characteristics, a Particle Image Velocimetry (PIV) and a thermo-vision camera were used in the present study. The experimental results showed that heat transfer from bubble surface to water was largely completed within z = 10 mm from the nozzle, and then the temperature of bubble surface reached that of water rapidly. Due to the centrifugal force, the flow was more developed near the wall than at bubble-water plume. Vortex flow in the bottom region was relatively weaker than that in the upper region.

COMBUSTION CHARACTERISTICS OF INHOMOGENEOUS METHANE-AIR MIXTURE IN A CONSTANT VOLUME COMBUSTION CHAMBER

  • Choi, S.H.;Jeon, C.H.;Chang, Y.J.
    • International Journal of Automotive Technology
    • /
    • 제5권3호
    • /
    • pp.181-188
    • /
    • 2004
  • A cylindrical constant-volume combustion chamber was used to investigate the flow characteristics at the spark electrode gap and the combustion characteristics of an inhomogeneous charge methane-air mixture under several parameters such as stratified pattern, initial charge pressure, ignition time and the excess air ratio of the initial charge mixture. Flow characteristics including mean velocity and turbulence intensity were analyzed by a hot-wire anemometer. The combustion pressure development, measured by a piezo-electric pressure transducer, was used to investigate the effect of initial charge pressure, excess air ratio and ignition times on combustion pressure and combustion duration. It was found that the mean velocity and turbulence intensity had the maximum value around 200-300 ms and then decreased gradually to near-zero value at 3000 ms. For the stratified patterns, the combustion rate under the rich injection (RI) condition was the fastest. Under the initial charge conditions, the second mixture was accompanied by an increase in the combustion rate, and that the higher the mass which is added in the second stage injection, the faster the combustion rate.

인공호흡시 호흡기류 계측 센서의 정확도 평가 (Accuracy Evaluation of Respiratory Air Flow Transducer for Artificial Ventilation)

  • 이인광;박미정;김경옥;신은영;손호선;차은종;김경아
    • 한국방사선학회논문지
    • /
    • 제9권7호
    • /
    • pp.425-431
    • /
    • 2015
  • 응급상황에서 중환자에게 시행되는 인공호흡 과정 중 호흡기류를 측정할 수 있도록 개발된 센서의 계측 정확도를 평가하였다. 호흡기류 센서의 압력-기류 특성식을 산출하였으며, 인공호흡시에 인가되는 호흡기류신호와 유사한 6가지 파형을 표준기류생성시스템으로 생성하여 호흡기류 센서에 가하면서 기류신호를 측정하였다. 이 기류신호로부터 일회호흡용적과 최대기류값을 산출하였으며, 이를 표준기류생성시스템에 부착되어 있고 물리적으로 오차가 없는 선형변위센서로부터 측정한 용적신호에서 산출한 표준값과 비교하였다. 일회호흡용적의 상대오차는 3% 이내이었으며, 최대기류값은 약 5% 정도로서 충분히 정확한 기류 계측이 가능함을 확인하였다. 따라서 실제 응급상황에서 호흡기류 센서로 적용하여 응급 중환자의 호흡신호와 호흡주기별 진단변수들을 실시간으로 모니터링 할 수 있는 시스템에 활용 가능할 것으로 사료된다.

상용 CFD코드를 이용한 공조기 입구형상의 설계 (Inlet Shape Design of Air Handling Unit Using Commercial CFD Code)

  • 최영석;주종일;주원구
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.448-453
    • /
    • 2001
  • A commercial CFD code is used to compute the 3-D viscous flow field within the inlet flow concentrator of the newly developed AHU(Air Handling Unit). To improve the performance of the AHU, the inlet air needs to be gradually accelerated to the fan's annular velocity without causing turbulence or flow separation. Three major geometric parameters were selected to specify the inlet shape of the AHU. Several numerical calculations are carried out to determine the influence of the geometric parameters on the performance of the AHU. The performance of the AHU could be measured by the inlet and outlet flow uniformity and the total pressure loss through the inlet flow concentrator. The optimized nondimensionalized velocity profile through the inlet flow concentrator were used for the design of the AHU with the various volume flow rates.

  • PDF

그래뉼 타입 활성탄 필터의 100 나노 미만 다분산 초미세먼지 표면흡착 제거 효율 연구 (Filtration Efficiency of Granular Activated Carbons to Polydisperse Ultrafine Particles through the Surface Adsoprtion)

  • 조경일;강기원;신지윤;김창혁
    • 한국입자에어로졸학회지
    • /
    • 제18권3호
    • /
    • pp.79-86
    • /
    • 2022
  • Many commercial air purifiers currently have deployed granular activated carbon (GAC) filters for removing volatile organic compounds in the indoor air. GACs are generally used to remove gaseous contaminants in the air through adsorption by the inner surfaces of pores. In addition, airborne particles can be also filtered by the surface adsorption of the GACs, which can improve the life-time of the particulate filters. In this study, the filtration efficiency of GACs to ultrafine particles through surface adsorption was investigated at different volume flow rates by deploying a continuous particle filtration system. The polydisperse sodium chloride (NaCl) particles were generated by a set of an atomizer and a diffusion dryer, and then mixed with particle-free air at different volume flow rates. The penetration of ultrafine particles and pressure drop for each experimental condition were measured to figure out the effect of the volume flow rate on the surface adsoprtion of the GACs to particles, ~ 2 mm. The particle filtration efficiency of the GACs decreased as the volume flow rate increased from 4 to 14 lpm. However, the 5 times thicker GAC filter layer decreased the penetration of ultraparticles than a preious study. The filtration efficiency of the single granule was also higher than the previous result in the literature with smaller granule filter materials.

횡단유동으로 분사하는 이유체노즐의 기체-액체비에 따른 분무특성 (Characteristics of Air-assist Spray Injected into Cross-flow with Various Gas-liquid Ratio)

  • 조우진;이인철;이봉수;이효원;구자예
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.159-162
    • /
    • 2007
  • 아음속 유동 내에 수직으로 분사된 액체제트의 액적분열 분포 특성을 알아보기 위해 이유체 노즐을 사용하여 실험적으로 연구하였다. 노즐은 L/d=3의 외부혼합형으로 공기와 액체의 비를 0 ${\sim}$ 59.4%까지 변화시키면서 분사하였다. 분무형상의 변화를 이미지화 하였으며 분무의 궤적과 액주의 형상을 관찰하였다. 액체제트 분열의 단면분포 특성을 PDPA를 사용하여 측정하였며 SMD, 액적속도, 그리고 체적유속을 측정하였다. 그 결과 노즐로 공급되는 공기의 양이 많아질수록 Y/d방향의 관통거리는 증가하였고 액적의 미립화는 가속화되는 것을 관찰할 수 있었다.

  • PDF

시뮬레이션을 이용한 개별사무공간의 살균공조시스템 연구 (A Study of air Sterilization System in Personalized Office Using Simulation)

  • 최상곤
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.353-360
    • /
    • 2010
  • Recently H1N1(swine flu) and SARS has been infected widely in the world; we have to care about germs and virus in indoor air environment. The air sterilization system investigated in this study allows occupants to turn on/off and to control the incoming air speed and direction. To predict the performance of air sterilization system without real experiment, a simulation is considered to compare and analyze the performance of the air sterilization systems in a typical office space. Multiple system parameters including volume flow rate and velocity of supply air were varied and investigated during the simulation. The investigation result shows that difference (between simulation and experiment) was about 3.5% in case of minimum air flow rate and about 0.2% in case of maximum air flow rate. The results indicate that multi-zone simulation technique can be used to predict the performance of a sterilization system in personalized office.

공기 중 석면농도 분석시 관상어용 기포발생기를 개조한 장치와 기존의 상업용 시료 채취기와의 성능 비교 (Comparison of the Efficiency between a Remodeled Bubble Generating Pumps for an Aquarium Fish and the Existed Commercial Air Sampler for the Sampling of Ambient Air Asbestos)

  • 장봉기;탁현욱;송수진;조봉현;김영지;손부순;이종화
    • 한국산업보건학회지
    • /
    • 제24권4호
    • /
    • pp.492-500
    • /
    • 2014
  • Objectives: The purpose of this study is to estimate the applicability of regional sample collection of environmental samples. The concentration of asbestos fibers were analyzed with two devices. One was an existing commercial air sampling pump that has been proved to be accurate and exact, and the other is a remodeled pump for sample collection which was made from an electric bubble generator originally designed for aquarium fish. Samples were collected with the two devices under the same environmental conditions and collection equipment. A comparative analysis of the concentration of ambient asbestos fiber was then performed. Methods: Based on previous research, six farmhouses with asbestos fiber slate roofs known to have high concentrations of asbestos fiber were selected. Using the existing commercial air sampling pump and the remodeled electric bubble generator, four to seven samples were collected each day one meter downwind from the edge of the slate roof at high volume (about 4 L/min) and low volume (about 1.4 L/min). The analyzer responsible for sample quality control of asbestos fibers counted the number of asbestos fibers with a phase microscope. Results: The rates of flow change of the existed sampler and the remodeled pump at high volume were 0.82% and 0.17%, respectively. The rates of flow change at low volume were 3.83% and 1.09%, but there was not significant difference. The rates of flow change are within the error range (${\pm}5%$) of OSHA analyzing methods. For the high volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 6.270 fibers/L and for the remodeled one 5.527 fibers/L, not a significant difference. For the low volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 7.755 fibers/L and for the remodeled one 7.706 fibers/L, not a significant difference. The total area of the slate roof of the targeted farmhouse has an effect on the concentration of asbestos fibers in the air from the existing pump and the remodeled one (p<0.01). Conclusions: The sampling function between the existing commercial pump and the remodeled one shows little difference. Therefore, the remodeled pump is considered a pump with a good availability for collecting ambient air asbestos samples.

CFD 기법을 활용한 공기층에 의한 마찰항력 감소 현상 연구 (Study on the Skin-frictional Drag Reduction Phenomenon by Air Layer using CFD Technique)

  • 김희택;김형태;이동연
    • 대한조선학회논문집
    • /
    • 제56권4호
    • /
    • pp.361-372
    • /
    • 2019
  • The flow pattern of air layers and skin-friction drag reduction by air injection are investigated to find the suitable multiphase flow model using unstructured finite-volume CFD solver for the Reynolds-averaged Navier-Stokes equations. In the present computations, two different multiphase flow modeling approaches, such as the Volume of Fluid (VOF) and the Eulerian Multi-Phase (EMP), are adopted to investigate their performances in resolving the two-phase flow pattern and in estimating the frictional drag reduction. First of all, the formation pattern of air layers generated by air injection through a circular opening on the bottom of a flat plate are investigated. These results are then compared with those of MMkiharju's experimental results. Subsequently, the quantitative ratios of skin-friction drag reduction including the behavior of air layers, within turbulent boundary layers in large scale and at high Reynolds number conditions, are investigated under the same conditions as the model test that has been conducted in the US Navy's William B. Morgan Large Cavitation Channel (LCC). From these results, it is found that both VOF and EMP models have similar capability and accuracy in capturing the topology of ventilated air cavities so called'air pockets and branches'. However, EMP model is more favorable in predicting quantitatively the percentage of frictional drag reduction by air injection.

대기오염 입자의 인체 호흡기내 비대칭 국부침전 특성에 관한 연구 (Study on the Asymmetric Regional Deposition of Airborne Pollutant Particles in the Human Respiratory Tract)

  • 구재학;김종숭
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.551-560
    • /
    • 2003
  • Particle deposition in human lungs was investigated theoretically by using asymmetric five-lobe lung model. The volumes of each of the five lobes were different, thereby forming an asymmetric lung structure. The tidal volume and flow rate of each lobe were scaled according to lobar volume. The total and regional deposition with various breathing patterns were calculated by means of tracking volume segments and accounting for particle loss during inhalation and exhalation. The deposition fractions were obtained for each airway generation and lung lobe, and dominant deposition mechanisms were investigated for different size particles. Results show that the tidal volume and flow rate have a characteristic influence on particle deposition. The total deposition fraction increases with an increase in tidal volume for all particle sizes. However, flow rate has dichotomous effects: a higher flow rate results in a sharp increase in deposition for large size particles, but decreases deposition for small size particles. Deposition distribution within the lung shifts proximally with higher flow rate whereas deposition peak shifts to the deeper lung region with larger tidal volume. Deposition fraction in each lobe was proportional to its volume. Among the three main deposition mechanisms, diffusion was dominant for particles < 0.5 ${\mu}{\textrm}{m}$ whereas sedimentation and impaction were most influential for larger size particles. Impaction was particularly dominant for particles> 8 ${\mu}{\textrm}{m}$. The results may prove to be useful for estimating deposition dose of inhaled pollutant particles at various breathing conditions.