• 제목/요약/키워드: Air-distribution rate

검색결과 542건 처리시간 0.032초

불균일한 풍속분포에 따른 응축기의 열전달 성능 변화 (Heat Transfer Performance Variation of Condenser due to Non-uniform Air Flow)

  • 이원종;정지환
    • 설비공학논문집
    • /
    • 제26권4호
    • /
    • pp.193-198
    • /
    • 2014
  • Heat transfer performance variation of a condenser caused by non-uniform distribution of air flow was investigated using a numerical simulation method. A heat exchanger used for a outdoor unit of a commercial heat pump system and represented by a numerical model was selected. Non-uniform profile of air-velocity was constructed by measuring the air velocity at various locations of the outdoor unit. Simulation was conducted for various refrigerant circuits and air flow conditions. Simulation results show that the heat transfer capacity was reduced depending on the air-flow rate and the refrigerant circuit configuration. It is also shown that the capacity reduction rate is increased as the average air velocity decreases.

200 t/d급 MHI 석탄 가스화기의 석탄 및 공기 배분에 따른 가스화 특성 평가 (Influence of coal and air flow rate distribution on gasification characteristics in 200 t/d scale MHI coal gasifier)

  • 도윤영;예인수;김봉근;류창국
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.93-96
    • /
    • 2015
  • Commercial coal gasifiers typically use entrained flow type reactors, but have unique features in terms of reactor shape, gasifying agent, coal feeding type, ash/slag discharge, and reaction stages. The MHI gasifier is characterized as air-blow dry-feed entrained reactor, which incorporates a short combustion stage at the bottom and a tall gasification stage above. This study investigates the flow and reaction characteristics inside a MHI gasifier by using computational fluid dynamics (CFD) in order to understand its design and operation features. For its pilot-scale system at 200 ton/day capacity, the distribution of coal and air supply between the two reaction stages was varied. It was found that the syngas composition and carbon conversion rate were not significantly influenced by the changes in the distribution of coal and air supply. However, the temperature, velocity and flow pattern changed sensitively to the changes in the distribution of coal and air supply. The results suggest that one key factor to determine the operational ranges of coal and air supply would be the temperature and flow pattern along the narrower wall between the two reaction stages.

  • PDF

공기 변화량 분포를 이용한 효율적인 인버터타입 압축기 시스템 (Efficient Inverter Type Compressor System using the Distribution of the Air Flow Rate)

  • 심재용;김용철;노영빈;정회경
    • 한국정보통신학회논문지
    • /
    • 제19권10호
    • /
    • pp.2396-2402
    • /
    • 2015
  • 공기압축기는 공장 및 설비 가동에 사용되는 필수 장비로써 미국 산업용 전기의 약 30%를 소비하고 있으며, 소비전력 절감을 위해 고급화된 기술 방안들이 제시되고 있다. 압축공기 변화량의 진폭변동이 작을 경우 시스템 안정성이 증가하며, 소비전력을 절감시켜 효율적인 에너지 시스템 설계를 가능하게 한다. 일반적으로 통계적 분석에서는 데이터의 분포를 정규분포, 로그정규분포, 감마분포 등을 이용하여 나타내지만, 압축공기 변화량을 나타내는 데이터처럼 긴 꼬리를 가지는 경우, 한 가지의 분포를 적용하는 것은 적합하지 않을 수 있다. 이에 따라, 본 논문에서는 압축공기의 변화량과 관련된 데이터를 두 개의 영역으로 나눈 혼합분포함수를 적용하여 평균전력 절감 가능성을 제시하였다. 이는 압축공기 변화량이 충분히 큰 수를 초과하는 영역에서는 가우시안 분포보다는 일반 파레토 분포가 더 정확한 퀀타일 값을 추정하는 데에 적합하기 때문이다.

다중 유로에서 과열도의 불균형에 따른 증발기의 성능 특성에 관한 연구 (The Effect of Non-uniform Superheat on the Performance of a Multi-path Evaporator)

  • 최종민;김용찬
    • 설비공학논문집
    • /
    • 제15권12호
    • /
    • pp.1043-1048
    • /
    • 2003
  • An experimental investigation was executed to determine the capacity degradation due to non-uniform refrigerant distribution in a multi-path evaporator. In addition, the possibility of recovering the capacity reduction by controlling the refrigerant distribution among refrigerant paths was assessed. The finned-tube evaporator, which had a three-path and three-depth-row, was tested by controlling inlet quality, exit pressure, and exit superheat for each refrigerant path. The capacity reduction due to superheat unbalance between each path was as much as 30%, even when the overall evaporator superheat was kept at a target value of 5.6$^{\circ}C$. It may indicate that the internal heat transfer within the evaporator assembly caused the partial capacity drop. For the evaporator having air mal-distributions, the maximum capacity reduction was found to be 8.7%. A 4.5% capacity recovery was obtained by controlling refrigerant distribution to obtain the target superheat at the outlet of each path.

2016년 여름철 폭염 시기 대구의 기온공간분포 특성 (Spatial Distribution of Air Temperature during an Extreme Heat Period in Daegu Metropolitan Area in 2016)

  • 김지혜;김해동
    • 한국환경과학회지
    • /
    • 제26권9호
    • /
    • pp.1023-1029
    • /
    • 2017
  • We studied the distribution of air temperature using the high density urban climate observation network data of Daegu. The observation system was established in February 2013. We used a total of 38 air temperature observation points (23 thermometers and 18 AWSs). From the distribution of monthly averaged air temperatures, air temperatures at the center of Daegu were higher than in the suburbs. The daily minimum air temperature was more than or equal to $25^{\circ}C$ and the daily maximum air temperature was more than or equal to $35^{\circ}C$ at the elementary school near the center of Daegu. Also, we compared the time elements, which are characterized by the diurnal variation of surface air temperature. The warming and cooling rates in rural areas were faster than in urban areas. This is mainly due to the difference in surface heat capacity. These results indicate the influence of urbanization on the formation of the daily minimum temperature in Daegu.

벽면으로 둘러싸인 제트 유동장에서의 마일드연소 및 오염물질 배출특성에 관한 전산해석 연구 (Computational Study of the Mild Combustion and Pollutant Emission Characteristics in Wall-confined Jet)

  • 송금미;오창보
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.263-266
    • /
    • 2012
  • The characteristics of mild combustion and pollutant emission were investigated computationally with supplied air stream temperature and dilution rate in jet flame. The air was diluted with main combustion products. As dilution rate increased at fixed air temperature, the temperature distribution of burner inside was uniformed and the maximum mole fraction of CO and NO was decreased. In addition, emission indices for NO, CO, and $CO_2$ were compared with air temperature and dilution rate.

  • PDF

Heat Generation Model of Angular Contact Ball Bearing with Oil-Air Lubrication

  • Na, Hee-Hyeong;Rhim, Yoon-Chul
    • KSTLE International Journal
    • /
    • 제1권1호
    • /
    • pp.63-68
    • /
    • 2000
  • Angular contact ball bearings are mainly used in the spindle, which requires high speed and stiffness. The heat generation is studied by experiments and simulations using a pair of angular contact ball bearings. The temperature variation of inner and outer races and the temperature increment distribution are measured by using thermocouples for the rotational speed, preload, viscosity of lubricant. The measured values from experiments are used to estimate the heat conduction rate. The method of oil-air lubrication is used for the experiment. The amount of conduction heat transfer to the test spindle and the convection heat transfer coefficients long the spindle are computed by using inverse method with temperature increment distribution. Total heat generation rate is estimated with the heat partition rate which is calculated from temperatures of inner and outer races. In addition, the empirical factor of oil-air lubrication method for Palmgren's heat generation model is suggested. The empirical friction coefficients, which are obtained from the experiments, depend on the preload condition, and can give us more accurate estimation of the heat generation in ball bearings.

  • PDF

전력공조시스템의 $CO_2$ 배출특성에 관한 연구 (A Study on the Characteristics of $CO_2$ Emissions for an Electric Powered Air Conditioning System)

  • 장영근;김석현
    • 설비공학논문집
    • /
    • 제14권5호
    • /
    • pp.433-440
    • /
    • 2002
  • Simulations were carried out to investigate the characteristics of $CO_2$ emissions for an electric powered air conditioning system. The $CO_2$ emissions were evaluated for various simulation parameters such as a power source distribution rate, power plant efficiency, power supply efficiency and system performance (COP). It was found that the $CO_2$ emissions were remarkably decreased by increasing the COP of the electric powered air conditioning system with storage tank. The $CO_2$emission per unit refrigeration capacity is 0.6 kg/RTh. And also, as the COP increase by 0.1, the $CO_2$ emissions decrease by 7.2%.

지중 및 보조루프의 2차 유체 유량 분배비를 통한 하이브리드 지열히트펌프의 성능 최적화 연구 (Performance Optimization of a Hybrid Ground Source Heat Pump According to Secondary Flow Distribution Ratio between the Ground and the Supplemental Loop)

  • 이주성;박홍희;김원욱;김용찬
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.102-110
    • /
    • 2012
  • The objective of this study is to improve the performance of a hybrid ground source heat pump (HGSHP) by optimizing the flow distribution ratio of secondary fluid flow rate between a ground loop and a supplemental loop. Initially, a conventional ground source heat pump (GSHP) was tested to determine an optimum flow rate of the secondary fluid. Based on the selected optimum value, the HGSHP was also tested by varying the flow distribution ratio of the secondary fluid flow rate between the ground loop and the supplemental loop, such as 9:1, 7:3, 5:5, and 3:7. The results showed that the optimum flow distribution ratio of the secondary fluid flow rate was 7:3. The COP of the HGSHP was improved by 19% over the GSHP at a flow distribution ratio of 7:3 and an entering water temperature of $40^{\circ}C$.

튜브 전기로를 이용한 TiO2 나노입자의 합성 및 특성 분석 (Synthesis and Analysis of Nanosized TiO2 Particles Using a Tube Furnace)

  • 배귀남;현정은;이태규;정종수
    • 한국대기환경학회지
    • /
    • 제20권3호
    • /
    • pp.411-419
    • /
    • 2004
  • Titania particles are widely used as a photocatalyst to treat various contaminants in air and water. Titania particles were formed by vapor-phase oxidation of titanium tetraisopropoxide (TTIP) in a tube furnace between 773 and 1,273 K. The effect of process variables such as furnace temperature, flow rate of carrier air, and flow rate of sheath air on powder size and phase characteristics was investigated using a scanning mobility particle sizer (SMPS), transmission electron microscopy (TEM) and X-ray diffraction (XRD). The size distribution of synthesized titania particles was characterized with mode diameter and peak concentration. The mode diameter ranging from 20 to 80 nm decreased with increasing flow rates of sheath air and carrier air, and increased with increasing furnace temperature. The peak concentration increased with increasing flow rates of sheath air and carrier air The best synthetic condition for high production rate can be derived from the experimental data set represented by mode diameter and peak concentration. The crystal structure of synthesized titania particles was found to be anatase phase, ensuring high photocatalytic potential.