• Title/Summary/Keyword: Air-cooled Heat Exchanger

Search Result 56, Processing Time 0.025 seconds

A Conceptual Study of an Air-cooled Heat Exchanger for an Integral Reactor (일체형 원자로의 공랭식 열교환기 개념 연구)

  • Moon, Joo Hyung;Kim, Woo Shik;Kim, Young In;Kim, Myoung Jun;Lee, Hee Joon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.49-54
    • /
    • 2016
  • A conceptual study of an air-cooled heat exchanger is conducted to achieve the long-term passive cooling of an integral reactor. A newly designed air-cooled heat exchanger is introduced in the present study and preliminary thermal sizing is demonstrated. This study mainly focuses on feasibility of an innovative air-cooled heat exchanger to extend the cooling period of the passive residual heat removal system(PRHRS) only in passive manners. A vertical shell-and-tube air-cooled heat exchanger is installed at the top of the emergency cooldown tank(ECT) to collect evaporated steam into condensate, which enables water inventory of the ECT to be kept. Finally, thermal sizing of an air-cooled heat exchanger is presented. The length and the number of tubes required, and also the height of a stack are calculated to remove the designated heat duty. The present study will contribute to an enhancement of the passive safety system of an integral reactor.

Comparison of Various Heat Exchanger Performances in order for Air Compressor Intercooler Application (공기압축기의 인터쿨러 선정을 위한 열교환기의 형상별 성능해석)

  • Yoo, Sang-Hoon;Park, Sang-Gu;Yoon, Jeong-Pil;Jeong, Ji-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.73-81
    • /
    • 2008
  • Intercooling and aftercooling are required in order to operate air compressor, these are conducted through air-cooled or water-cooled heat exchangers. This study aims to find more suitable type of heat exchanger as a water-cooled intercooler of air compressor. Comparative performance evaluation among fin-tube heat exchanger and shell-and-tube (S&T) heat exchanger having various tubes such as circular tube, spiral tube, and internally finned tube was conducted. Thermal-hydraulic performance of each heat exchanger type is evaluated in terms of temperature drop and pressure drop. The comparisons show that shell-and-tube heat exchangers may have similar and larger heat transfer capacity to the fin-tube heat exchanger if tube diameter is reduced and multiple pass is adopted. For these cases, however, compressed air pressure drop in shell-and-tube heat exchanger become much larger than that in fin-tube heat exchanger.

Advances In Air-Cooled Heat Exchanger Technology for Residential Air-Conditioning

  • Webb Ralph L.;Kim Nae-Hyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.4
    • /
    • pp.184-195
    • /
    • 2005
  • This paper describes the recent work on advanced technology concepts applied to air cooled heat exchangers for residential air-conditioning. The concepts include vortex generators for the air-side, micro-fin or flat tubes for the refrigerant-side. Advances in understanding of heat transfer mechanisms, predictive models are discussed.

Vibration Reduction of an Air Cooled Heat Exchanger with Axial Flow Fan (축류송풍기 부착형 공냉식 열교환기의 진동저감)

  • 정구충;최연선
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.6
    • /
    • pp.163-168
    • /
    • 2001
  • Vibration problems occurred in an air cooled heat exchanger with axial flow fan for a petrochemical plant were investigated. Experimental field test and theoretical verification were performed. To find the main cause of the high vibration of the fan at the air inlet of the axial fan, the frequency spectrum was measured. The natural frequency of the driving support of the heat exchanger was numerically calculated. Both of the measured and the natural frequency were approximately equal to the blade passing frequency. Because it was difficult to modify the structure of the driving support during the normal operation of the plant, the blade number of the fan was increased, which greatly reduced the vibration level of the heat exchanger.

  • PDF

Design of air-cooled waste heat removal system with string type direct contact heat exchanger and investigation of oil film instability

  • Moon, Jangsik;Jeong, Yong Hoon;Addad, Yacine
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.734-741
    • /
    • 2020
  • A new air-cooled waste heat removal system with a direct contact heat exchanger was designed for SMRs requiring 200 MW of waste heat removal. Conventional air-cooled systems use fin structure causing high thermal resistance; therefore, a large cooling tower is required. The new design replaces the fin structure with a vertical string type direct contact heat exchanger which has the most effective performance among tested heat exchangers in a previous study. The design results showed that the new system requires a cooling tower 50% smaller than that of the conventional system. However, droplet formation on a falling film along a string caused by Rayleigh-Plateau instability decreases heat removal performance of the new system. Analysis of Rayleigh-Plateau instability considering drag force on the falling film surface was developed. The analysis results showed that the instability can be prevented by providing thick string. The instability is prevented when the string radius exceeds the capillary length of liquid by a factor of 0.257 under stagnant air and 0.260 under 5 m/s air velocity.

Development of an Cross Flow Air-Cooled Plate Heat Exchanger (직교류 공랭식 판형열교환기의 성능평가)

  • Kim, Min-Sung;Lee, Jae-Hoon;Park, Seong-Ryong;Ra, Ho-Sang;Jeong, Jae-Hoon;Lim, Hyug
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.235-240
    • /
    • 2007
  • Performance of an air-cooled plate heat exchanger (PHE) was evaluated in this study. The PHE was manufactured in two types of single-wave and double-wave plates in parallel assembly. The heat exchanger aims to substitute open-loop cooling towers with closed-loop water circulation, which guarantees cleanliness and compactness. In this study, prototype single-wave and double-wave PHEs were designed and tested in a laboratory scale experiments. From the tests, the double-wave PHE shows approximately 50% enhanced heat transfer performance compared to the single-wave PHE. However, the double-wave PHE costs 30% additional pressure drop. For the commercialization, a wide channel design for air flow would be essential for performance and reliability.

  • PDF

Numerical Analysis on the Performance of a Outdoor Air Cooled Heat exchanger for Cooling Tower (외기이용 하이브리드 냉각탑 성능해석)

  • Kim, Sung-Il;Lee, Wook-Hyun;Lee, Kye-Jung;Chun, Won-Pyo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2322-2327
    • /
    • 2008
  • This paper is to provide analysis model that can be used to investigate the improvement in energy efficiency for cooling tower by using fresh air. Numerical analysis of Air-cooled heat exchanger for single-phase flow with variations of outdoor air temperature has been performed. A complete set of correlations of the heat transfer in both refrigerant and air sides was employed for predicting the heat transfer rate. The numerical results derived from the correlations were verified with experimental results. The energy consumption for a hybrid cooling tower has been compared for variation of a outdoor air temperature. The results showed that the hybrid cooling tower in low outdoor temperature offers a significant improvement in energy efficiency. The thermal analysis aids significantly in the solution of the design problem of hybrid cooling tower.

  • PDF

An Experimental Study on Understanding of Production Mechanism of a Mist from Fin Adhesion heat Exchanger (핀 부착 열교환기에서 습증기(mist)발생 메커니즘의 파악을 위한 실험적 고찰)

  • 최권삼
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.146-152
    • /
    • 2000
  • As an improvement in the standard of living and economic growth the demand for air conditioning equipment is increasing rapidly. Nowadays air conditioning equipments are being used for industry large building house and car. Thess equipments was concentrated on improving heat efficiency of economic aspects while they design heat exchanger for cooling and heating,. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore the user demand air of high class and quality. In this experimental study to acquire elementary data for development of heat exchanger which be able to supply air of high quality that is to say possess a restraint effect of mist generation. We estimate an effect on cooling plate kind supply air velocity supply air temperature cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

A Study on the Energy Saving of Cooling/Reheating System Using Heat Exchanger (열교환기를 사용한 냉각/재가열 장치의 에너지 절감에 관한 연구)

  • Kim, Jin-Hyuck;Yoo, Seong-Yeon;Choi, Yang-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.482-491
    • /
    • 2010
  • In conventional air-handling units, when the circulated air from the air-conditioned space pass through the cooling coil, the air is over-cooled to eliminate the moisture as well as to decrease the temperature. The purpose of this study is to estimate the thermal performance and energy saving of the cooling/reheating system using heat exchanger which can save both cooling energy and reheating energy by exchanging heat between the cooled air and reheated air. The energy balance equations to estimate the state of the air for each components were provided and the heat transfer rates and the energy saving rates for the system were calculated from the equations. The results showed that the energy saving was up to 40% under present conditions, and saving rates were significantly affected by the air velocity, inlet conditions and the effectiveness of heat exchanger.

Investigation on the Cooling Characteristics of a Regenerative Evaporation Water Cooler (재생증발식 수냉각기의 냉각성능 해석)

  • Choi Bong-Su;Hong Hi-Ki;Lee Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.393-401
    • /
    • 2006
  • The regenerative evaporation water cooler is devised and analysed in this study. The regenerative evaporation water cooler is composed of a sensible heat exchanger to cool the incoming air, followed by a latent heat exchanger to cool the water evaporatively with the cooled air flowing out of the sensible heat exchanger. By linearizing psychrometric characteristics, the heat and mass transfer in the regenerative evaporation water cooler is analyzed theoretically. The results show that the water can be cooled down even lower than the wet-bulb temperature of the inlet air. When the inlet air is $32^{\circ}C$ and 20% in relative humidity, and the inlet temperature of the water is $20^{\circ}C$, the regenerative evaporation water cooler provides a larger cooling capacity than the conventional evaporation water cooler if the effectiveness of the latent heat exchanger is higher than 0.6 and that of the sensible heat exchanger is higher than 0.5.