• Title/Summary/Keyword: Air-conditioning system

Search Result 3,317, Processing Time 0.027 seconds

Study on the Collector Efficiency of an Air Heater in a Solar Air Conditioning System (태양열 이용 냉난방 공조시스템 중 공기식 집열기의 집열효율에 관한 연구)

  • Kim, B.C.;Shin, H.J.;Choi, K.H.;Kum, J.S.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.1-8
    • /
    • 2000
  • The suggested year round solar air conditioning system has been developed for cooling and heating. In particular, this system focused on cooling and dehumidification and it could reduce a peak time owing to the use of air conditioners in summer. This study was performed to find out how much heating loads could be saved and furthermore whether this suggested system would be possible to do heating without a switch of system in real situations. Through model house experiments, the following conclusions were obtained. 1) The collector efficiency was 36% at maximum, but more improved structure of suggested collector could increase its efficiency. 2) The temperature of outlet air was about $30^{\circ}C$ and it could reduce heating loads. 3) Measured temperature and calculated one agreed well within ${\pm}1.5^{\circ}C$.

  • PDF

Study on the Performance Characteristics with the Height of a Regenerator and Dehumidifier for Liquid Desiccant Dehumidification System (액체식 제습시스템을 위한 재생기와 제습기의 높이에 따른 성능특성에 관한 연구)

  • 이수동;박문수;정진은;최영석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.7
    • /
    • pp.630-638
    • /
    • 2004
  • Liquid desiccant dehumidification systems have the ability to provide efficient humidity and temperature control while saving the electrical energy requirement for air conditioning as compared to a conventional system. The dehumidifier and the regenerator form the heart of this system. The latent part of the cooling load is overcome using liquid desiccant. The model regenerator has been designed to study the absorption characteristic of the aqueous triethylene glycol (TEG) solution which is in the flow range from 20 to 50 LPM. Also, this system designed that was able to change the height of the regenerator and dehumidifier. Because the effect of performance have different result according the height. The effect of performance factors of the regenerator with inlet solution flow rate, air flow rate, solution concentration, solution temperature, brine temperature, air temperature and inlet air relative humidity have been analyzed. Data obtained are useful for design guidance and performance analysis of the hybrid air conditioning system.

A Study on the Improvement of a Cooling System by the Increment of Room Humidity without Reheating Process (실내 습도 증가를 이용한 무재열 냉방시스템 개선에 관한 연구)

  • Lee Hung Joo;Kim Yong Ku
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.6
    • /
    • pp.613-619
    • /
    • 1987
  • In a room air conditioning cooling system, if the room-sensible-heat-factor as plotted on a Psychrometric Chart intersects the saturation curve below the apparatus leaving air dewpoint, reheat must be used to maintain the design room air conditions. However, if the design room humidity is permitted to be raised to some degree, the cooling system will not require reheat as a new room-sensible-heat-factor line is developed between the apparatus leaving air dew-Point and the adjusted design room air conddition point. The advantages to this are the cost of reheat equipment and operation can be avoided. The cycle of this system can be shown on a Psychrometric Chart to plot the design condition points.

  • PDF

On the Characteristics of the Low Velocity Displacement Air-Conditioning System (저속치환 공조시스템의 특성에 대한 연구)

  • Lee, Kye-Cheul;Kim, Dong-Kyu;Kim, Kyoung-Gu;Kwon, Young-Pil
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.493-498
    • /
    • 2001
  • In the low velocity displacement air-conditioning system, the conditioned air is supplied from the diffuser placed on the wall near the floor and vented near the ceiling. This system has some advantages upon the traditional mixing system; the air quality near the people is improved by the displacing action of the system and the energy may be saved by neglecting the cooling or heating load for the upper space of the space above the people. This study is to examine the temperature and velocity distributions in the room and near the diffuser. It is found that the temperature is stratified uniformly all over the room space to show the displacing function of the system.

  • PDF

Cooling Performance of Several $CO_2/propane$ Mixtures in an Air-Conditioning System (이산화탄소/프로판 혼합냉매의 냉방성능 특성)

  • Kim, Ju-Hyok;Kim, Min-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.47-54
    • /
    • 2006
  • [ $CO_2$ ] and propane mixtures were chosen as promising alternative refrigerants and their performance potentials were evaluated experimentally in an air-conditioning system. Pure $CO_2$ and 85/15, 75/25 and 60/40 binary blends by the charged mass percentage of $CO_2/propane$ were selected as working fluids. The effect of the inlet temperature of the secondary fluids and degree of superheat on the cooling performance was tested and discussed. The charging amounts of refrigerants were adjusted to make the system show the maximum COP. Comparisons among different refrigerants were carried out on the same compressor speed basis for a given operating condition. In addition, the temperature gliding effect of zeotropic mixtures on the system performance were analyzed based on the drop-in test results.

Experimental Study of the Superheat and Control of the Refrigerant Flow-Rate in the Evaporator of a Multi-type Air-Conditioning System (멀티형 공조시스템의 증발기 과열도에 관한 실험적 연구 및 냉매유량 제어)

  • 김태섭;홍금식;손현철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.221-221
    • /
    • 2000
  • The heat exchange part in a modern multi-type air-conditioning system employs multiple-pass heat exchangers. The heat-transfer performance of an each pass in such an exchanger depends strongly on the length of the two-phase region and the mass flow of the refrigerant. The total length and diameters of the pipes, the exit conditions, and the arrangement of each pass as well as the geometrical shape of the distributor at the branching sections are considered to be major factors affecting the heat-transfer performance. The refrigerant commonly used in these systems is HCFC-22. The two objectives of this paper are to investigate the characteristics of the refrigerant flow rate and the superheat in the evaporator of a multi-type air-conditioning system for a single or simultaneous operating conditions and to control the superheat and the refrigerant flow rate of the evaporator.

  • PDF

Comparative Study on Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air-Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 비교연구)

  • Kim, Hyung-Tae;Song, Gen-Soo;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun;Kwon, Oh-Myung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1249-1255
    • /
    • 2011
  • In modern large-scale semiconductor manufacturing clean rooms, the energy consumed by the outdoor air-conditioning system during heating, humidification, cooling, and dehumidification of the incoming outdoor air represents about 45% of the total air-conditioning load required to maintain a clean-room environment. In particular, the energy required for humidification of the outdoor air in winter is very high. Therefore, evaluation and comparison of the energy consumption in key humidification systems, viz., steam-humidification and water-spray-humidification systems, used in outdoor air-conditioning systems would be useful to reduce the outdoor air-conditioning load in clean rooms. In the present study, an experiment with an outdoor air flow of 1000 $m^3$/h was conducted to compare the air-conditioning process and energy consumption in outdoor air-conditioning systems with electrodeboiler steam humidifiers and air-washer water spray humidification systems. The experimental results showed that the water-spray-humidification-type outdoor air-conditioning system consumed less electrical power than did the steam-humidification-type system and was more energy efficient during winter.