• 제목/요약/키워드: Air-borne

검색결과 235건 처리시간 0.026초

주변고정 장방형 평판에 있어서 임의점 가진에 의한 고체전파음의 예측 (An estimate of structure-borne sound by the excitation at an arbitrary point on the rectangular plate with fixed edges)

  • 김의간
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.21-34
    • /
    • 1988
  • Machinery enclosures are widely adopted to reduce the noise emission in various fields of application. Emitted noise, which is due to the vibration of enclosure's outer surface, is composed of two kinds of sound with different path of propagation. One is the "structure-borne sound", while the other is "air-borne sound". In order to get a most efficient machinery enclouser a prudent consideration upon the above structure-borne and air-borne sound is required, as the guiding principle of contermeasure for each noise is quite different. The controlling of input vibration and its isolation are major subjects for the structure-borne sound, and the specifications of absorbing members and damping panels are the major related matters for the air-borne sound. Hence, it seems very efficient to separate the total sounds into two categories with a great accuracy when one think of further reduction of noise from the existing enclosure, although its separating methods have not been made clear for many years. Author proposes an application method of experimental modal analysis to extract the structure-borne sound from the measured total radiation sound, as the air-borne sound is deduced by the vectorial difference between the measured total radiation sound and the calculated structure-borne sound. In order to calculate the correct structure-borne sound by the excitation at an arbitrary point on the enclosure structure, it is important to decide 1) how to estimate the enclosure's surface vibration velocity and 2) how to compute the radiation sound which is considered as the effect of vibration modes of enclosure surface. The former can be solved with total frequency response function calculated by the application of experimental modal analysis. The latter is to be solved by the author's new approaches for radiation sound computation by means of the Rayleigh's integral equation and the boundary-element method applied complex surface vibration velocity. As a first step, structure-borne sound by the excitation at an arbitry point on the rectangular plate with fixed edges, has been calculated to verified the reliability of the developed computation methods. The results of calculation show good agreements with those of the actual measurements.actual measurements.

  • PDF

차음구조물의 방사음향파워로부터 고체 및 공기전파음향파워의 정량적인 분리법 (A Quantitative Separation Method of Structure and Air Borne Sound Power from the Enclosure)

  • 김의간;강동림
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제16권5호
    • /
    • pp.85-96
    • /
    • 1992
  • Engine enclosures are widely adopted to reduce the noise emission in various fields of application. The radiated noise, which is due to the vibration of enclosure's outer surface, is composed of two kinds of sound power with different path of propagation. One is the 'structure-borne sound power' which stems from the engine's vibratory force applied to the structure of enclosure through the mounting parts of engine etc., while the other is the 'air-borne sound power' which is originated by the sound power radiated from the engine surface to the inner space of enclosure that should excite the vibration of enclosure from inside. In order to get a most efficient engine enclosure is required a profound consideration upon the above structure-borne and air-borne noise, since the guiding principle of countermeasure for each noise is quite different. The controlling of input vibration and its isolation are major subject for the structure-borne sound power and the specifications of absorbing member and damping panels are the major interests for the air-borne sound power. Hence it seems very efficient to separate the total sound power into two categories with a great accuracy when one think of further reduction of engine noise from the exciting enclosure, however, its separating methods have not been made clear for many years. Then author proposes a new practical separation method of two propagation path's contribution to the total radiation sound power for the enclosure under the engine operating condition.

  • PDF

CD-ROM 구동 시 발생소음 분석 및 저감 방안에 관한 연구 (A Study of Acoustic Noise Analysis and Reduction Method for Driving CD-ROM)

  • 이재승;차성운
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.904-907
    • /
    • 2002
  • Optical disk drive device is improved in rotating speed for faster data reading. In the case of CD-ROM, rotating speed is over 10000 rpm in the practical use. As a result of high rotating speed, unexpected effects as like increasing disk fluctuation and acoustic noise are raised by the air friction on the rotating disk and the eccentricity of rotating parts. The overall acoustic noise of running CD-ROM could be classified into two different characterized noise. The first is the structural-borne noise which is generated from vibrating solid body. By the reason, the signal of structural borne noise has very similar to the signal of surface vibrating one. It has dense noise energy at specific frequency region. The other is the air-borne noise which is generated from turbulence or vortex caused by friction between disk and air. The signal of air-borne noise has no dominant peak point at acoustic pressure-frequency domain. The noise energy is widely distributed while comparatively high and large frequency region. The structural-borne noise could be reduced by reducing vibration of structure and in addition it's target reducing frequency is narrow. However the air-borne noise reduction is effectively needed of enclosing method for the noise source located near the disk surface because it is difficult to define target frequency point. In this study, the acoustic noise at driving CD-ROM is classified by the sides of it's character and tried to reduce the overall acoustic noise.

  • PDF

대기 중 납의 RISK예측모형 개발 (The Development of Risk Predictive Model for Air-borne Lead in Blood)

  • 김종석
    • 한국환경보건학회지
    • /
    • 제19권3호
    • /
    • pp.46-51
    • /
    • 1993
  • In order to survery the risk of air-borne lead to human, the relation between air-borne lead level and blood lead level was examined by using of the kinetic model and statistical model. The results of this survey were as follows: 1. The pathways of lead intake were food and water, mainly. 2. Though blood lead level of Korean urbanire was higher than that of American or Japanese, it was not so severe as to influence human health. 3. The lead content in food and water was high, and so it is needed to confirm the cause of high content was whether second contamination by air pollution or not.

  • PDF

전달 경로 분석과 패널 기여도 분석을 이용한 휠로더의 실내소음 저감에 관한 연구 (Interior Noise Reduction of Wheel Loader Using Transfer Path Analysis and Panel Contribution Analysis)

  • 김보용;신창우;정원태;박성용;장한기;김성재;강연준
    • 한국소음진동공학회논문집
    • /
    • 제18권8호
    • /
    • pp.805-815
    • /
    • 2008
  • Transfer path analysis(TPA) and panel contribution analysis(PCA) have been used widely to reduce interior noise of mechanical systems. TPA enables us to decompose interior noise into air-borne and structure-borne noises and estimate the path contribution of noise sources. PCA is also used to identify the noise contribution of each sub-panel in vibro-acoustic systems. In this paper, TPA and PCA are applied to wheel loader, one of the heavy construction equipments. Firstly, TPA for air-borne noise is conducted to estimate the contribution of air-borne sources using pressure transfer function. Thereafter, TPA for structure -borne noise is employed to verify the results of air-borne source quantification through the synthesis of two results. Secondly, PCA is performed by both TPA using pressure transfer function between panels inside the cabin and boundry element method(BEM) for the cabin of wheel loader with various boundary conditions. As a results, it was found that TPA conducted by experiments and PCA accomplished by both experiments and BEM are very effective methods in analyzing the path and contribution of the noises for reducing an interior noise level in the wheel loader system.

Study on Noise Reduction of AV Projector

  • Kim, Sang-Hoon;Bok, Ki-So;Lee, Seung-Gyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1155-1158
    • /
    • 2007
  • To reduce acoustic noise level of an AV projector, primary noise sources of AV projector were analyzed. Based on the analyzed result, methods to control each source are presented and tried. Structure-borne noise can be controlled by anti vibration design of mounting system, and air-borne noise by reducing flow resisitvity.

  • PDF

철도차량 구조기인 소음의 저감에 관한 연구 (A Study on the Reduction of Structure-borne Noise in a Train)

  • 우관제;김석현
    • 한국철도학회논문집
    • /
    • 제11권6호
    • /
    • pp.519-523
    • /
    • 2008
  • 철도차량의 실내소음은 공기기인 소음과 구조기인 소음이 더해진 것이다. 본 논문에서는 개활지 주행중 실내소음을 지배한다고 알려져 있는 구조기인 소음에 대해 연구하였다. 구조기인 소음을 진동원, 전달경로 및 소음 발생부로 구분하여 실내소음을 줄이기 위한 방안에 대해 연구하였다.

실차에 대한 공기기인 소음경로분석법 적응 (Application of Air-Borne Noise Path Analysis to a real vehicle)

  • 김윤재;정원태;송문성;강연준;김홍빈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.699-702
    • /
    • 2006
  • Noise Path Analysis is commonly used method to analysis noise transmission characteristics of a system. To analysis transfer paths of a system, it is necessary to know operating forces at each transfer path. The method to find out operating forces is divided into two methods. The one is a direct method which measures operating forces directly and the other is an indirect method which estimates operating forces mathematically. However, the indirect method is more commonly used because of the difficulty of measurement. This paper is focused on the indirect method and air-borne noise of a vehicle. Noise Path Analysis for Air-Borne Noise is applied to a real vehicle.

  • PDF

함정 내 소음 평가를 위한 불확도 추정 기법 연구 (Study on the estimation of uncertainty for the air-borne noise measurements in a naval ship)

  • 김성용
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.396-402
    • /
    • 2014
  • 함정의 높은 함내소음은 승조원들 간의 의사전달을 방해하여 전투력 저하를 야기하고, 근무환경의 질을 떨어뜨리므로 함내소음 측정은 매우 중요한 관리 항목 중 하나이다. 그러므로 대부분의 신조함정은 인수 시운전 단계에서 함내소음을 측정하고 제시된 기준을 만족하도록 건조되고 있다. 함내소음 측정 결과로부터 기준 만족 여부를 판단하기 위해서는 측정 불확도를 고려하는 것이 반드시 필요하다. 본 논문에서는 함정 인수 시운전시의 함내소음 평가 방법을 소개하고, 함내소음을 평가하기 위한 불확도 추정 방법을 적용하였다. 신조 함정 7척에 적용한 결과, 함내 소음 불확도는 1dB 이하로 오차가 시운전 평가서 허용 오차(2dB) 내에 있음을 확인하였다. 현재 실험방법은 허용기준을 만족하고는 있지만 보다 신뢰성 있는 측정 결과를 위해 실험 방법 등의 개선으로 허용오차를 줄일 필요성이 있을 것으로 판단된다.

보육시설 급식실 실내 환경에서 분리된 식중독 미생물의 항생제 내성 특성 (Antibiotic Resistance of Food-Borne Pathogens Isolated from an Indoor Environment of a Lunchroom in a Child Care Center)

  • 김중범;김종찬
    • 한국환경보건학회지
    • /
    • 제38권5호
    • /
    • pp.415-423
    • /
    • 2012
  • Objectives: This study was performed in order to evaluate antibiotic resistance and analyze the multiple antibiotic resistance of food-borne pathogens isolated from indoor air and an air cleaner at a lunch room in a child care center. Methods: An antibiotic test of food-borne pathogens, including four Staphylococcus aureus and 23 Bacillus cereus was conducted through the disk diffusion method from Clinical and Laboratory Standard Institute. Results: All Staph. aureus was resistant to Ampicillin and Penicillin, while B. cereus was also resistant to Ampicillin, Cefepime and Penicillin. All isolates showed Vancomycin susceptibility but three out of four Staph. aureus and all B. cereus were resistant to Oxacillin. Staph. aureus and B. cereus presented two or more multiple antibiotic resistances. Conclusions: The results indicated that food-borne pathogens isolated from indoor air and an air cleaner at a lunch room in a child care center showed multiple antibiotic resistances. The repeated control of indoor environment quality is required and continuous surveillance of antibiotic resistant strains is demanded.