• Title/Summary/Keyword: Air-bag

Search Result 243, Processing Time 0.023 seconds

A Newly Designed Cervical Pillow Department of Rehabilitation Medicine (새로 디자인된 경부베개)

  • He, Jin-Gang
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.2
    • /
    • pp.1063-1073
    • /
    • 1999
  • Objective: Poor head and neck support during sleep can exacerbate the neck pain. Based on the ideal sleep posture and pillow suggested by Cyriax, we designed a new cervical pillow and compared the degree of pain reduction, quality of sleep and pillow satisfaction with a low hospital pillow and a high pillow. Method: The newly designed pillow has a built-in pressure-adjustable air bag in the cervical area and provides normal cervical lordotic curve in supine position and maintains cervical and thoracic vertebrae to form a horizontal line in side-lying position. Thiry-four patients with cervical pain used low hospital pillows for the first week of 3-week randomized crossover design study. They were subsequently randomly assigned to use each of the other two pillows for 1-week period. Outcomes were measured using Visual analog scale, Sleep questionaire, a pillow satisfaction scale. Result: Compared with other 2 types of pillow, Subjects using the newly desinged pillow showed much reduced pain intensity, increased duration of sleep and better satisfaction. Conclustion: We desinged a cervical pillow with built-in pressure adjustable air bag and it can significantly reduce pain intensity and improve quality of sleep in patients with cervical pain.

  • PDF

Development of Novel Assistive Device for Improving Usability of BVM (인공호흡기 사용성 향상을 위한 새로운 보조기구 개발)

  • Jeon, Gang-Hyun;Park, Yong-Jai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.420-426
    • /
    • 2020
  • In this study, an assistive device for BVM (Bag Valve Mask) was developed. When emergencies occur, rescuers must perform artificial respiration within four minutes utilizing suitable BVM. If not, the patient can suffer serious damage within their brain and body systems. The rescuer must execute artificial respiration until the patient arrives at the hospital. In the process of artificial respiration, the rescuer can feel fatigued in their forearm muscles, particularly those who may have smaller hands or weaker muscle strength. Many products have been developed to solve these problems, but these products are difficult to market and commercialize because of their volume, size, and difficulty of use. In this paper, the BVM assistive device that has been previously manufactured was improved, and an attempt was made to devise a new method that reduces the burden on the user. The BVM assistive device can be divided into three-parts: a head part for compressing the air bag, which can control the amount of air; the body part for coupling with BVM; and finally, the handle that can rotate for better use on various postures of patients. Throughout the experiment, the assistive device could inject an equal amount of air into the patients. As a result, the rescuer could feel less fatigue and inject a suitable amount of air to emergency patients during artificial respiration.

Determination of Airborne Formaldehyde Using the Gas Chromatograph-Pulsed Discharge Electron Capture Detector (GC-PDECD를 이용한 공기 중 포름알데하이드의 분석)

  • 김희갑;박미진;김만구
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.117-123
    • /
    • 2002
  • A gas chromatographic method for the determination of airborne formaldehyde was established. In order to be highly detectable with the electron capture detector, formaldehyde was derivatized to its pentafluorobenzyl oxime form by reacting with O- (2,3,4,5,6- pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) at pH of 4.6 and temperature of 50$^{\circ}C$ for 1 hour. Air samples were collected into a Tedlar$\^$(R)/ bag followed by transferring into water contained in two impingers in series. Collection efficiency in the front trap was higher than 90%. Measurement of selected indoor and outdoor air samples showed higher formaldehyde concentrations in indoor air environments and the importance of ventilation for reducing indoor pollution.

Finite Element Analysis of Diaphragm Type Air Springs considering the Variation of Fiber Angles (섬유의 적층각을 고려한 다이아프램형 공기 스프링의 유한요소 해석)

  • Lee, Hyeoun-Guk;Kim, Se-Ho;Heo, Hun;Kim, Jin-Yeong;Chung, Su-Gyo
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.04a
    • /
    • pp.29-33
    • /
    • 1999
  • this paper concerned with the stress analysis of a diaphragm-type air spring which consists of rubber linings nylon reinforced rubber composite. The analysis is carried out with a finite element method developed to consider the orthotropic properties geometric non-linearity and contact between an air bag and a bead ring The material properties are evaluated with the Halpio-Tsai equations and the rule of mixture. The analysis results demonstrate the variation of the outer diameter the fold height and the vertical force with different models to the design a proper diaphragm air springs.

  • PDF

A Study on the Pressure drop Variance of Pulse interval, injection distance in Pulse Air Jet Type Bag Filter (충격기류식 여과집진장치의 펄스간격 밀 분사거리에 따른 압력손실변화에 관한 기초 연구)

  • Seo, Jeong Min;Choe, Geum Chan;Park, Jeong Ho
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.223-232
    • /
    • 2004
  • The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to $50mmH_2O$ varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/㎥ and 1g/㎥, the pressure $drop(\DeltaP)$ was stable 60 to 90minutes after operation. For the higher concentration of 3g/㎥, as $\DeltaP$ continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 1l0mm, when inlet dust concentration is 0.5g/㎥ or 1g/㎥, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/㎥ and 3g/㎥ has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.

A Case of Severe Asthma Complicated with Pneumoperitoneum and Pneumomediastinum During AMBU Ventilation (AMBU(Air Mask Bag Unit) 환기로 복강기종과 종격동기흉이 합병된 중증 천식 1예)

  • Cho, Hoon;Choi, Byoung-Moon;Jung, Ho-Kyoung;Park, Ja-Young;Jang, Byoung-II;SunWoo, Mi-Ok;Seo, Chan-Hee;Sung, Han-Dong;Sin, Mi-Jeong;Hwang, Soon-Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.585-589
    • /
    • 2001
  • Pneumoperitoneum, Pneumomediastinum, subcutaneous emphysema and a pneumothorax are some of the mechanical complications of bronchial asthma. The incidence of pneumoperitoneum during an attack of acute asthma is rare. The pathogenesis is free gas track from the overdistended alveoli, through the bronchovascular sheaths to the mediastinum. If the high pressure is maintained, air can escape retroperitoneally into the abdomen and burst into the peritoneal cavity. A 43-year-old woman was admitted due to a severe asthma attack. She was required endotracheal intubation and AMBU(air mask bag unit) ventilation. Immediately after these procedures, pneumoperitonewn, pnewnomediastinwn, and subcutaneous emphysema developed. She was treated with mechanical ventilation and medical therapy. The pneumoperitonewn was resolved after 27days. Here, we report this case with the review of the relevant literature.

  • PDF

Evaluation of Indoor Air Improvement of Matrix Using Activated clay as Adsorption Material (활성백토를 흡착재로 활용한 경화체의 실내 공기 개선 평가)

  • Jeong, Hyun-Su;Kim, Yeon-Ho;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.189-190
    • /
    • 2020
  • The importance of indoor air quality management has recently been highlighted due to environmental problems such as indoor air pollution. Among indoor air pollutants, carbon dioxide occurs in cooking, heating, burning, and causes forgetfulness, dementia and amnesia. Radon, which occurs in building materials, soil and ground, is a type 1 carcinogen that causes lung cancer in the body through breathing. These substances can be released from the room through ventilation, but there is a limit to reducing the amount of indoor activity due to reduced ventilation conditions due to increased indoor activity time. However, these substances can be removed from the gas by adsorption. The purpose of this study was to identify the properties of granular active and powdered active white soil and mix them to make cement-based active white soil adsorbent matrix for carbon dioxide, fine dust and radon gas adsorption, and to evaluate indoor air improvements according to the mixing scale. The results of the experiment showed that active carbon dioxide adsorption performance increased for carbon dioxide and radon as the exchange rate increased through physical adsorption. In particular, the higher the replacement rate of the granular active bag, the better adsorption performance was shown.

  • PDF

A Study on the Performance of Mechanical Crash Sensors (기계식 충돌 센서의 성능 해석)

  • Kim, K.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.1
    • /
    • pp.136-142
    • /
    • 1995
  • An analysis model is proposed for the performance prediction of typical ball and tube type mechanical crash sensors based upon mass-spring-viscous gas damping idealization. Also a construction of mechanical crash pulse generator is suggested as an experimental tool for calibration and verification of model predictions. A sensor tuning procedure for a particular set of crash pulses is suggested based upon the analysis model and the experimental tools.

  • PDF

Experimental Study for Pressure Drop Characteristics of Membrane Laminated Bag Filtration System (박막여과포 집진장치의 압력손실 성능 특성 실험)

  • 박현설;송창병;박영옥;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.467-468
    • /
    • 1999
  • 여과집진장치는 기존의 집진장치 중에서 집진효율이 가장 우수하나, 여과집진에서 필연적으로 발생하는 높은 압력손실과 탈진에 따른 여과포의 마모, 그리고 고온조건에서의 성능저하 등은 여과집진장치의 광범위한 적용을 저해하는 요인으로 작용해왔다. 탈진에 따른 여과포의 손상을 막고, 먼지입자의 표면여과를 극대화시키는 방법으로 기존의 여과포에 박막을 입히는 방법이 많은 연구자들에 의해 개발되어 왔다.(중략)

  • PDF

Change of Total Bacteria, Lactic bacteria and Textural Parameters during Kimchi Preservation (김치저장중 총세균.유산균 및 물성변화에 관한 연구)

  • 임국이
    • Journal of the Korean Home Economics Association
    • /
    • v.25 no.4
    • /
    • pp.57-62
    • /
    • 1987
  • To obtain basic data for the decvelopment of Kimchi preservation method, optimal ripening Kimchi was air-packaged with polyethylene bag, and followed by the microbiological, firmness and sensory evaluations during storage at 5$^{\circ}C$. 1. Total aerobic count increased in the beginning of storage and then decreased slowly as the number of total Lactic bacteria(anaerobe) in creased. 2. Textural parameters were remarkably changed according to the elapse of storage period. 3. Sensory evaluation showed that the score was decreased considerably 10 days after storage.

  • PDF