• Title/Summary/Keyword: Air-Water two-phase flow performance

Search Result 51, Processing Time 0.022 seconds

Air Influx Characteristics of Turbo Pumps (공기 유입시의 터보펌프 특성)

  • Kim, You-Taek;Nam, Cheong-Do;Kang, Ho-Keun;Lee, Young-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.43-48
    • /
    • 2004
  • A screw-type centrifugal pump was manufactured to carry solids primarily and its impeller has a wide flow passage. However, the effect of flow passage shape on delay of the choke due to entrained air has not been clarified yet. Moreover, because its impeller has a particular shape, only few studies have tried to clarify the pump performance and details of internal flow pattern of that pump. For that reason, we carried out the pump performance experiment under air-water two-phase flow condition with different impeller tip clearances, pump rotational speeds and void fractions by using a small screw-type centrifugal pump designed to acquire basic data. In a general centrifugal pump, it was reported that loss of pump head from single-phase flow to the choke due to air entrainment new the best efficiency point was large. However, the loss near the best efficient point in a screw-type centrifugal pump became less than that in a general centrifugal pump.

  • PDF

CFD Analysis on Two-phase Flow Behavior of Liquid Water in Cathode Channel of PEM Fuel Cell (PEM 연료전지 공기극 유로에서 물의 가동에 대한 CFD 해석)

  • Kim, Hyun-Il;Nam, Jin-Hyun;Shin, Dong-Hoon;Chung, Tae-Yong;Kim, Young-Gyu
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.8-15
    • /
    • 2007
  • Liquid water in flow channel is an important factor that limits the steady and transient performance of PEM fuel cells. A computational fluid dynamics study based on the volume-of-fluid [VOF] multi-phase model was conducted to understand the two-phase flow behavior of liquid water in cathode gas channels. The liquid water transport in $180^{\circ}{\Delta}$ bends was investigated, where the effects of surface characteristics (hydrophilic and hydrophobic surfaces], channel geometries (rectangular and chamfered corners], and air velocity in channel were discussed. The two-phase flow behavior of liquid water with hydrophilic channel surface and that with hydrophobic surface was found very different; liquid water preferentially flows along the corners of flow channel in hydrophilic channels while it flows in rather spherical shape in hydrophobic channels. The results showed that liquid water transport was generally enhanced when hydrophobic channel with rounded corners was used. However, the surface characteristics and channel geometries became less important when air velocity was increased over 10m/s. This study is believed to provide a useful guideline for design optimization of flow patterns or channel configurations of PEM fuel cells.

  • PDF

Flow regime transition criteria for vertical downward two-phase flow in rectangular channel

  • Chalgeri, Vikrant Siddharudh;Jeong, Ji Hwan
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.546-553
    • /
    • 2022
  • Narrow rectangular channels are employed in nuclear research reactors that use plate-type nuclear fuels, high heat-flux compact heat exchangers, and high-performance micro-electronics cooling systems. Two-phase flow in narrow rectangular channels is important, and it needs to be better understood because it is considerably different than that in round tubes. In this study, mechanistic models were developed for the flow regime transition criteria for various flow regimes in co-current air-water two-phase flow for vertical downward flow inside a narrow rectangular channel. The newly developed criteria were compared to a flow regime map of downward air-water two-phase flow inside a narrow rectangular channel with a 2.35-mm gap width under ambient temperature and pressure conditions. Overall, the proposed model showed good agreement with the experimental data.

Effect of Main Operating Conditions on Cathode Flooding Characteristics in a PEM Unit Fuel Cell (고분자전해질형 단위 연료전지의 주요 작동 조건이 공기극 플러딩 현상에 미치는 영향)

  • Min Kyoung-Doug;Kim Han-Sang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.5 s.248
    • /
    • pp.489-495
    • /
    • 2006
  • Proton exchange membrane (PEM) should be sufficiently hydrated with a careful consideration of heat and water management. Water management has been a critical operation issue for better understanding the operation and optimizing the performance of a PEM fuel cell. The flooding on cathode side resulting from excess water can limit the fuel cell performance. In this study, the visual cell was designed and fabricated fur the visualization of liquid water droplet dynamics related to cathode flooding in flow channels. The experiment was carried out to observe the formation, growth and removal of water droplets using CCD imaging system. Effects of operating conditions such as cell temperature, air flow rate and air relative humidity on cathode flooding characteristics were mainly investigated. Based on this study, we can get the basic insight into flooding phenomena and its two-phase flow nature. It is expected that data obtained can be effectively used fur the setup and validation of two-phase PEM fuel cell models considering cathode flooding.

IDENTIFICATION OF TWO-DIMENSIONAL VOID PROFILE IN A LARGE SLAB GEOMETRY USING AN IMPEDANCE MEASUREMENT METHOD

  • Euh, D.J.;Kim, S.;Kim, B.D.;Park, W.M.;Kim, K.D.;Bae, J.H.;Lee, J.Y.;Yun, B.J.
    • Nuclear Engineering and Technology
    • /
    • v.45 no.5
    • /
    • pp.613-624
    • /
    • 2013
  • Multi-dimensional two-phase phenomena occur in many industrial applications, particularly in a nuclear reactor during steady operation or a transient period. Appropriate modeling of complicated behavior induced by a multi-dimensional flow is important for the reactor safety analysis results. SPACE, a safety analysis code for thermal hydraulic systems which is currently being developed, was designed to have the capacity of multi-dimensional two-phase thermo-dynamic phenomena induced in the various phases of a nuclear system. To validate the performance of SPACE, a two-dimensional two-phase flow test was performed with slab geometry of the test section having a scale of $1.43m{\times}1.43m{\times}0.11m$. The test section has three inlet and three outlet nozzles on the bottom and top gap walls, respectively, and two outlet nozzles installed directly on the surface of the slab. Various kinds of two-dimensional air/water flows were simulated by selecting combinations of the inlet and outlet nozzles. In this study, two-dimensional two-phase void fraction profiles were quantified by measuring the local gap impedance at 225 points. The flow conditions cover various flow regimes by controlling the flow rate at the inlet boundary. For each selected inlet and outlet nozzle combination, the water flow rate ranged from 2 to 20 kg/s, and the air flow rate ranged from 2.0 to 20 g/s, which corresponds to 0.4 to 4 m/s and 0.2 to 2.3 m/s of the superficial liquid and gas velocities based on the inlet port area, respectively.

Effects of Entrained Air on the Characteristics of a Small Screw-type Centrifugal Pump (공기 흡입이 소형 스크류식 원심펌프의 특성에 미치는 영향)

  • Kim, You-Taek;Tanaka, Kazuhiro;Lee, Young-Ho;Matsumoto, Yoichiro
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.37-44
    • /
    • 1999
  • In a screw-type centrifugal pump, the pump head deteriorates from single-phase flow to the choke due to an increased air entrainment at a wide tip clearance compared to that of a narrow tip clearance. Moreover, at a narrow tip clearance, the pump head became partially higher in a two-phase flow than that of a single-phase flow near the best efficiency point in low void fraction region. Therefore, we observed the internal flow pattern by using a stroboscope and we measured the mean size of bubbles from the images obtained with a high speed camera. Then, we investigated the influences of the mean size of bubbles, tip clearances and flow patterns on pump performance.

  • PDF

Numerical Simulation and Experimental Study on an Ejector System for VOC Recovery (VOC 회수를 위한 이젝터 시스템에 관한 수치모사 및 실험적 연구)

  • Kim, Hyun-Dong;Lee, Dong-Yeop;Kim, Yoon-Kee;Jeong, Won-Taek;Ahn, Joo-Ha;Kim, Kyung-Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.2
    • /
    • pp.54-60
    • /
    • 2011
  • This paper is a basic study on volatile organic compounds(VOC) recovery system in a crude oil carrier. VOC is easily evaporated in cargo tankers during loading and transportation of crude oil, causes serious environmental contamination and a huge economic loss. An ejector system is designed to mix VOC gas into crude oil flow to reduce VOC concentration. Detail two-phase flow inside the ejector is simulated using a commercial CFD code. To verify the numerical prediction, a scale-down experiment is conducted. Instead of crude oil and VOC, water and air are used as the working fluids. Flow characteristics and main parameters are obtained by two-phase flow visualization and PIV measurements. Air volume flow rate induced by the ejector is compared with respect to the volume flow rate of water using experimental and numerical results. Overall performance of the two-phase ejector predicted by the CFD simulation agrees well with that of the experiment.

A Study on the Break-down Characteristics of a Screw-type Centrifugal Pump due to Air Entrainment (공기흡입에 의한 스크류식 원심펌프의 양수불능 특성에 관한 연구)

  • Kim, You-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.3 s.20
    • /
    • pp.58-63
    • /
    • 2003
  • The performance of turbo pump drops rapidly and it gets into break-down when the void fraction reaches above the threshold value because the impeller flow passage is choked up with air bubbles. Phenomenological understanding of break-down and pumping recovery mechanisms under air-water two-phase flow conditions are therefore important for pump designers and essential assignment for researchers. In this paper, we investigated the characteristics of break-down and pumping recovery due to entrained air occurring inside a screw-type centrifugal pump which has a wide flow passage mainly through the findings of suction and discharge pressures, rotational speed, flow rate measurements and visualization.

Evaluation of Bubble Size Models for the Prediction of Bubbly Flow with CFD Code (CFD 코드의 기포류 유동 예측을 위한 기포크기모델 평가)

  • Bak, Jin-yeong;Yun, Byong-jo
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.69-75
    • /
    • 2016
  • Bubble size is a key parameter for an accurate prediction of bubble behaviours in the multi-dimensional two-phase flow. In the current STAR CCM+ CFD code, a mechanistic bubble size model $S{\gamma}$ is available for the prediction of bubble size in the flow channel. As another model, Yun model is developed based on DEBORA that is subcooled boiling data in high pressure. In this study, numerical simulation for the gas-liquid two-phase flow was conducted to validate and confirm the performance of $S{\gamma}$ model and Yun model, using the commercial CFD code STAR CCM+ ver. 10.02. For this, local bubble models was evaluated against the air-water data from DEDALE experiments (1995) and Hibiki et al. (2001) in the vertical pipe. All numerical results of $S{\gamma}$ model predicted reasonably the two-phase flow parameters and Yun model is needed to be improved for the prediction of air-water flow under low pressure condition.