• 제목/요약/키워드: Air-Gap Formation

검색결과 36건 처리시간 0.022초

주형/주물 접촉면에서의 접촉열저항을 고려한 상변화문제에 관한 연구 (Numerical Analysis for Stefan Problem in Mold-Casting with Air-Gap Resistance)

  • 여문수;손병진;이관수
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.348-355
    • /
    • 1992
  • Casting structures and properties are determined by the solidification speed in the metal mold. The heat transfer characteristics of the interface between the mold and the casting is one of the major factors that control the solidification speed. According to Sully's research, the thermal resistance exists due to the air-gap formation at the mold-casting interface during the freezing process and the interface heat transfer coefficient is used to describe the degree of it. In this study, one-dimensional Stefan problem with air-gap resistance in the cylindrical geometry is considered and heat transfer characteristics is numerically examined. The temperature distribution and solidification speed are obtained by using the modified variable time step method. And the effects of the major parameters such as mold geometry, thermal conductivity, heat transfer coefficient and initial temperature of casting on the thermal characteristics are investigated.

공기층 저항을 고려한 사각형 주형내에서의 2차원 상변화문제에 관한 연구 (A Study on the Two-Dimensional Phase Change Problem in a Rectangular Mold with Air-Gap Resistance to Heat Flow)

  • 여문수;손병진;김우승
    • 대한기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.1205-1215
    • /
    • 1992
  • 본 연구에서는 1차원 상변화문제를 확장하여 사각형 주형내에서의 접촉열저항 을 고려한 2차원 상변화문제를 해석하고자 한다.즉 고상/액상 경계면인 상변화면을 추적하기 위하여 온도수식법(temperature formulation method)을 적용시 나타나는 복 잡성을 극복하기 위하여 제시된 엔탈피법을 이용하여 순수물질의 경우 뿐만 아니라 2상영역이 존재하는 합금에서의 온도분포, 상변화면의 이동속도 및 총응고에 소요되는 시간등의 열적특성을 해석하며, 또한 이러한 열적특성에 영향을 미치는 매개변수를 도출하고자 주형의 형상, 주형 외벽에서의 열전달계수, 접촉 열전달계수, 주형의 열전 도계수 및 주물의 초기온도등의 변화에 따른 효과를 고찰한다.

엔탈피법을 이용한 원통형 몰드내에서의 상변화과정에 관한 연구 (A study on the phase change in the cylindrical mold by the enthalpy method)

  • 여문수;최상경;김문철
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.891-897
    • /
    • 1999
  • The heat transfer characteristics at the interface between the mold and the casting is one of the major factors for the solidification speed which determines the casting structures. The thermal resistance exists due to air gap formation at the mold/casting interface during the freezing process. In this study one dimensional Stefan problem with the air-gap resistance in the cylindrical mold is considered and the heat transfer characteristics is numerically examined by using the enthalpy method which is convenient in solving the Stefan problem with mushy zone. The present results agreed very well with those of previous papers. The effects of major parameters such as thermal conductivity, heat transfer coefficient of mold, on the thermal characteristics are investigated.

  • PDF

폭발볼트의 구속환경에 따른 분리메커니즘 연구 (Study of Separation Mechanism According to the Constraint Condition of Explosive Bolts)

  • 정동희;이영우
    • 한국추진공학회지
    • /
    • 제20권2호
    • /
    • pp.67-74
    • /
    • 2016
  • 폭발볼트는 고폭약를 사용하는 분리장치의 하나로서 폭발볼트의 내부에서 형성되는 폭압 및 충격파에 의해 분리된다. 이러한 메커니즘을 갖는 폭발볼트는 분리시 생성되는 충격파 및 파편형성 최소화되도록 설계되어야 할 것이다. 본 연구에서는 폭발볼트 및 볼트를 구속하는 구속물과의 거리(Air gap)을 변수로 두어 분리시험을 수행하였다. 이때 Air gap 따른 분리유무 및 분리 형상을 확인 하였고, 가속도 센서를 이용하여 구속물의 전달되는 Pyro-shock를 측정하였다. 또한 ANSYS Autodyn 프로그램을 이용하여 폭발볼트의 분리거동을 해석하였다. 실험 및 해석으로부터 폭발볼트와 구속물 사이의 Air gap 크기에 따른 폭발볼트의 분리거동에 미치는 영향을 확인하였고 특정 볼트에 한해서 최적의 폭발볼트의 구속환경을 설정하였다.

Surface Treatment of Air Gap Membrane Distillation (AGMD) Condensation Plates: Techniques and Influences on Module Performance

  • Harianto, Rachel Ananda;Aryapratama, Rio;Lee, Seockheon;Jo, Wonjin;Lee, Heon Ju
    • Applied Science and Convergence Technology
    • /
    • 제23권5호
    • /
    • pp.248-253
    • /
    • 2014
  • Air Gap Membrane Distillation (AGMD) is one of several technologies that can be used to solve problems fresh water availability. AGMD exhibits several advantages, including low conductive heat loss and higher thermal efficiency, due to the presence of an air gap between the membrane and condensation wall. A previous study by Bhardwaj found that the condensation surface properties (materials and contact angle) affected the total collected fresh water in the solar distillation process. However, the process condition differences between solar distillation and AGMD might result in different condensation phenomena. In contrast, N. Miljkovic showed that a hydrophobic surface has higher condensation heat transfer. Moreover, to the best of our knowledge, there is no study that investigates the effect of condensation surface properties in AGMD to overall process performance (i.e. flux and thermal efficiency). Thus, in this study, we treated the AGMD condensation surface to make it hydrophobic or hydrophilic. The condensation surface could be made hydrophilic by immersing and boiling plate in deionized (DI) water, which caused the formation of hydrophilic aluminum hydroxide (AlOOH) nanostructures. Afterwards, the treated plate was coated using hexamethyldisiloxane (HMDSO) through plasma-enhanced chemical vapor deposition (PECVD). The result indicated that condensation surface properties do not affect the permeate flux or thermal efficiency significantly. In general, the permeate flux and thermal efficiency for the treated plates were lower than those of the non-treated plate (pristine). However, at a 1 mm and 3 mm air gap, the treated plate outperformed the non-treated plate (pristine) in terms of permeate flux. Therefore, although surface wettability effect was not significant, it still provided a little influence.

Fabrication of Electrochemical Sensor with Tunable Electrode Distance

  • Yi, Yu-Heon;Park, Je-Kyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제5권1호
    • /
    • pp.30-37
    • /
    • 2005
  • We present an air bridge type electrode system with tunable electrode distance for detecting electroactive biomolecules. It is known that the narrower gap between electrode fingers, the higher sensitivity in IDA (interdigitated array) electrode. In previous researches on IDA electrode, narrower patterning required much precise and expensive equipment as the gap goes down to nanometer scale. In this paper, an improved method is suggested to replace nano gap pattering with downsizing electrode distance and showed that the patterning can be replaced by thickness control using metal deposition methods, such as electroplating or metal sputtering. The air bridge type electrode was completed by the following procedures: gold patterning for lower electrode, copper electroplating, gold deposition for upper electrode, photoresist patterning for gold film support, and copper etching for space formation. The thickness of copper electroplating is the distance between upper and lower electrodes. Because the growth rate of electroplating is $0.5{\mu}m\;min^{-1}$, the distance is tunable up to hundreds of nanometers. Completed electrodes on the same wafer had $5{\mu}m$ electrode distance. The gaps between fingers are 10, 20, 30, and $40{\mu}m$ and the widths of fingers are 10, 20, 30, 40, and $50{\mu}m$. The air bridge type electrode system showed better sensitivity than planar electrode.

Dependence of Ozone Generation in a Micro Dielectric Barrier Discharge on Dielectric Material and Micro Gap Length

  • Sakoda, Tatsuya;Sung, Youl-Moon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권5호
    • /
    • pp.201-206
    • /
    • 2004
  • In order to investigate the optimum conditions for the effective ozone formation in a dielectric barrier discharge, measurements of ozone concentration were carried out for various conditions such as the gap length, the dielectric material and the operating gas. It was found that the optimum discharge conditions differed exceedingly in the types of operating gases and dielectric materials. In dry air, dielectric material with low dielectric constant and thermal conductivity, which might contribute to the restriction of the gas temperature rise in the discharge region, proved effective in obtaining both high ozone yield and concentration. The optimum gap length was considered to be in the range of 600-800 mm. In oxygen, using a quartz glass disk as a dielectric material, the required condition to obtain the high ozone yield and concentration was expanded.

Effects of cementless fixation of implant prosthesis: A finite element study

  • Lee, Hyeonjong;Park, Soyeon;Kwon, Kung-Rock;Noh, Gunwoo
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.341-349
    • /
    • 2019
  • PURPOSE. A novel retentive type of implant prosthesis that does not require the use of cement or screw holes has been introduced; however, there are few reports examining the biomechanical aspects of this novel implant. This study aimed to evaluate the biomechanical features of cementless fixation (CLF) implant prostheses. MATERIALS AND METHODS. The test groups of three variations of CLF implant prostheses and a control group of conventional cement-retained (CR) prosthesis were designed three-dimensionally for finite element analysis. The test groups were divided according to the abutment shape and the relining strategy on the inner surface of the implant crown as follows; resin-air hole-full (RAF), resin-air hole (RA), and resin-no air hole (RNA). The von Mises stress and principal stress were used to evaluate the stress values and distributions of the implant components. Contact open values were calculated to analyze the gap formation of the contact surfaces at the abutment-resin and abutment-implant interfaces. The micro-strain values were evaluated for the surrounding bone. RESULTS. Values reflecting the maximum stress on the abutment were as follows (in MPa): RAF, 25.6; RA, 23.4; RNA, 20.0; and CR, 15.8. The value of gap formation was measured from 0.88 to 1.19 ㎛ at the abutment-resin interface and 24.4 to 24.7 ㎛ at the abutment-implant interface. The strain distribution was similar in all cases. CONCLUSION. CLF had no disadvantages in terms of the biomechanical features compared with conventional CR implant prosthesis and could be successfully applied for implant prosthesis.

정적 연소실 내에서의 2유체 가솔린 분사기의 착화 특성에 대한 실험적 연구 (An experimental study on the ignition characteristics of an air-assisted gasoline injector in a constant volume combustion chamber)

  • 이용표;김승수
    • 오토저널
    • /
    • 제14권4호
    • /
    • pp.31-38
    • /
    • 1992
  • The objective of this study is to determine the ignition feasibility of a single shot, air-assisted gasoline fuel injector operated in a constant volume combustion chamber under atmospheric condition. A number of parameters has been selected for this experiments, such as dwelling time, spark gap position(r,z), spark electrode geometry, supplied air and fuel masses and spray cone deflector angle. On-site visual inspection of the instantaneous flame glow was chosen as one way to judge the successful ignition. In addition, chamber pressure and occasional photography were mobilized as for data recording. It was clearly observed that there was an entrainment air-fuel mixture toward spray axis from the spray formation and its development later on. The optimum ignition conditions were found for those parameters given above.

  • PDF

연소효율 개선을 위한 스월제트의 난류유동 특성에 관한 연구 (A Study on the Turbulent Flow Characteristics of Swirl Jets for Improvement of Combustion Efficiency)

  • 고동국;윤석주
    • 한국분무공학회지
    • /
    • 제19권2호
    • /
    • pp.75-81
    • /
    • 2014
  • Swirl flow in the gun type burner has a decisive effect on the stabilization of the flame, improvement of the combustion efficiency, and also a reduction of NOx. This swirl flow is created by the spinner which is inside the airtube that guide the combustion air. Gun type burner has generally the inner devices composed nozzle adapter, spark gap ignitor, and spinner. These inner components change the air flow behavior passing through air tube. Meanwhile, turbulent characteristics of this air flow are important to understand the combustion phenomena in the gun type burner, because the mixture of fuel and air are depended on. However, nearly all of the studies have been analyzed the turbulent flow of simplified combustion formation without the inner devices. So, this study conducted the measurement using by hot-wire anemometer and analyzed turbulent flow characteristics of the swirl flow discharged from the air tube with inner devices. Turbulence characteristics come up in this study were turbulence intensity, kinetic energy and shear stress of the air flow with the change of the distance of axial direction from the exit of the air tube.