• 제목/요약/키워드: Air-Conditioning system

검색결과 3,317건 처리시간 0.027초

체계중심병원설계를 위한 공조실 면적 계획에 관한 연구 (A Study on Area Planning of Air Conditioning Room for Hospital Design Focused on System)

  • 김은석;양내원
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권4호
    • /
    • pp.27-35
    • /
    • 2019
  • Purpose: As the improvement in quality of medical environment and the spatial consideration for the prevention of infection in the hospital have become increasingly important in the recent years, specific and practical planning for air conditioning room's area has become a major issue accordingly. However, the air conditioning room tends to be discussed focusing on technical factors such as air conditioning systems that are irrelevant to building plans, while discussions of most departments related to the medical functions have actively taken placed. Therefore, this study aims to investigate the factors influencing the planning for the air conditioning room area, and through subsequent analysis of the area of the air conditioning room, to propose a way to improve effective planning for the air conditioning room area. Methods: This study examines the case hospitals that fall into two types: each floor supply system and concentrated supply system, and compares and analyzes the air conditioning room area-related factors and the characteristics of changes in the interior of air conditioning room before and after remodeling through air conditioning floor plan of those case hospitals. Results: The air conditioning room can be classified into the net area of the functional space such as duct passages, and the public area such as aisle space, and of those the public area is an important factor in calculating the area of the air conditioning room. The public area of the air-conditioning room should not be planned considering only the spaces for mobile passage or maintenance activities, but should be planned taking into account internal changes such as expansion and replacement of equipment in the future from the beginning. Implications: When planning a medical facility, it is used as basic data for the planning of the air conditioning room area, which is a significant fixed factor in the initial setting.

체계중심병원설계를 위한 공조조닝 설정의 건축 계획에 관한 연구 (A Study on Architectural Planning of Establishing Air-Conditioning Zoning for Hospital Design Focused on System)

  • 김은석;양내원
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권3호
    • /
    • pp.29-38
    • /
    • 2018
  • Purpose: Space planning to cope with the changing function of the hospital is essential in hospital architecture. In order to do so, it is vital that the paradigm shifts from hospital design focused on purpose toward hospital design focused on system. Not only space planning but also air-conditioning plan, which is most closely related to the operation and maintenance of hospital facilities; and the environment of hospital users, should be able to respond to changes with ease. Thus this study is to provide fundamental data of the air-conditioning plan for the hospital design focused on system by analyzing the concept and characteristics of the air-conditioning plan in the recent hospital architecture planning. Results: As a result of this study, in the air conditioning plan for the hospital architecture planning, the most important are the location relation among the departments the air handling unit room and the air handling unit manage and the air conditioning zoning setting according to the air conditioning system. Therefore, for the hospital architecture planning focused on system, it is necessary to establish the air conditioning setting that can accommodate changeable environment of departments and accordingly the appropriate area range of the air conditioning zoning and the plan for the location of the air handling unit should be considered. Implications: Thereby aims to provide fundamental data on air handling unit zoning planning in the hospital architecture planning.

복합 열원 공조시스템의 최적 제어 알고리즘 (Optimal Control Algorithm for the Dual Source Chiller Air Conditioning System)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.881-888
    • /
    • 2004
  • Control algorithms for a dual source chiller air conditioning system were developed. These are control algorithms for the supply air temperature control, the supply header chilled water temperature control, the chiller chilled water temperature control, and the cooling tower water temperature control. These algorithms were analyzed by using a dynamic simulation program. Simulation results showed the energy savings and the satisfactory controls of an absorption and centrifugal chiller air conditioning system. Therefore, control algorithms developed for this study may effectively be used for the improved controls of the dual source chiller air conditioning system.

Partial Fault Detection of an Air-conditioning System by using a Moving Average Neural Network

  • Han, Do-Young;Lee, Han-Hong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권3호
    • /
    • pp.125-131
    • /
    • 2003
  • The fault detection and diagnosis technology may be applied in order to decrease the energy consumption and the maintenance cost of the air-conditioning system. In this paper, two fault detection methods were considered. One is a generic neural network, and the other is an moving average neural network. In order to compare the performance of fault detection results from these methods, two different types of faults in an air-conditioning system were applied. These are the condenser 30% fouling and the evaporator fan 25% slowdown. Test results showed that the moving average neural network was more effective for the detection of partial faults in the air-conditioning system.

개별환경제어(PEM)시스템의 열적 특성 및 성능개선에 관한 연구 (The Experimental Study on Thermal Characteristics of PEM(Personal Environment Module) System)

  • 조성환;장철용;태춘섭
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.439-447
    • /
    • 2000
  • The PEM(Personal Environment Module) system is an individual air conditioning system developed in order to improve thermal comfort in office buildings. In this study, thermal characteristics of a PEM system have measured experimentally and compared with UFAC(Under Floor hir Conditioning) system in the EC(Environment Chamber) constructed in KIER. Results showed that the PEM system was better than UFAC system for thermal comfort and energy conservation.

  • PDF

데이터 전처리기법을 적용한 신경망 알고리즘의 냉방기 부분고장 검출 (Partial Fault Detection of Air-conditioning System by Neural Network Algorithm using Data Preprocessing Method)

  • 한도영;이한홍;윤태훈
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.560-566
    • /
    • 2002
  • The fault detection and diagnosis technology may be applied in order to decrease the energy consumption and the maintenance cost of the air-conditioning system. In this study, two different types of faults in the air-conditioning system, such as the condenser fouling and the evaporator fan slowdown, were considered. The neural network algorithm combined with data preprocessor was developed and applied to detect the faults of the real system. Test results show that this method is very effective to detect the faults in the air-conditioning system. Therefore, this developed method can be used for the development of the air-conditioner fault detection system.

Evaluation of Indoor Environmental Factors in Office Building with Underfloor Air-Conditioning (UFAC) System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.36-45
    • /
    • 2001
  • During the last decade, an increasing interest in Underfloor Air-Conditioning (UFAC) systems has emerged. The purpose of this paper is to evaluate the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. The physical measurements and the Interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation (POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey .

  • PDF

HFC152a 대체냉매를 이용한 자동차 냉방장치의 성능 최적화에 관한 연구 (Study of Performance Optimization as an Alternative Refrigerant HFC152a in a Mobile Air Conditioning System)

  • 이대웅
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.321-327
    • /
    • 2015
  • This study presents an HFC152a refrigerant air conditioner as an alternative to HFC134a, which is currently used in mobile air conditioning systems. Cool-down performance tests of an HFC152a air conditioning system were conducted and compared to a baseline HFC134a air conditioner. The experimental set-up consisted of a belt-driven compressor, a sub-cooled type condenser, an evaporator, and a block-type thermal expansion valve (TXV). A drop-in test was carried out on the mobile air conditioning system under various vehicle running speeds in a climate-controlled wind tunnel (CWT). Additionally, to optimize the HFC152a air conditioning system, the effects of the TXVs on the performance were studied. The results show that compared to the HFC134a air conditioning system, the refrigerant charge quantity was reduced by approximately 20%, the discharge pressure was reduced by about 350~430 kPa, and the air discharge temperature at vehicle running conditions was $0.5{\sim}1.5^{\circ}C$ lower. In addition, good compressor durability was expected due to the lower compression ratio.

Simulation of the Air Conditioning System Using Fuzzy Logic Control

  • Mongkolwongrojn, M.;Sarawit, W.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2270-2273
    • /
    • 2003
  • Fuzzy logic control has been widely implemented in air conditioning and ventilation systems which has uncertainty or high robust system. Since the dynamic behaviors of the systems contain complexity and uncertainty in its parameters , several fuzzy logic controllers had been implemented to control room temperature in the field of air conditioning system. In this paper, the fuzzy logic control has been developed to control room temperature and humidity in the precision air conditioning systems. The nonlinear mathematical model was formulated using energy and continuity equations. MATLAB was used to simulate the fuzzy logic control of the multi-variable air conditioning systems. The simulation results show that fuzzy logic controller can reduce the steady-state errors of the room temperature and relative humidity in multivariable air conditioning systems. The offset are less than 0.5 degree Celsius and 3 percent in relative humidity respectively under random step disturbance in heating load and moisture load respectively

  • PDF