• 제목/요약/키워드: Air-Compressor

검색결과 1,026건 처리시간 0.022초

낮은 증발온도에서 운전되는 가변속 롤러형 베인 압축기의 성능특성에 관한 분석 (Analysis on the performance characteristics of a variable-speed, roller-type vane compressor operating at low evaporating temperature)

  • 김봉훈
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.193-204
    • /
    • 1999
  • Performance of a variable-speed, roller-type vane compressor was evaluated at low evaporating temperature. First, an experimental investigation was conducted to examine the performance variation as functions of both outdoor temperature and rotating speed. For this purpose, a typical heat pump was implemented as a test apparatus to measure mass flow rate and power input. Secondly, computational investigations corresponding to the heat pump test conditions were performed to predict compressor performance using ORNL Map-Based compressor model. Results obtained from the heat-pump experiments showed that both mass flow rate and power consumption were sensitively dependent on both evaporating temperature and compressor speed as was predicted from the computational results. From the comparisons of both experimental and computational results, it was well recognized that the ORNL model was subjected to larger error in the accuracy of prediction as outdoor temperature decreased. When the outdoor temperature was above $-5^{\cire}C$, errors of predicted values corresponding to both mass flow rate and power consumption were estimated as $\pm$10% and $\pm$ 15%, respectively. Finally, it is suggested that the ORNL model needs to be re-evaluated if compressor map data tested below $-5^{\cire}C$(in evaporating temperature) are available.

  • PDF

구름 피스톤 이용 회전식 압축기 진동 해석 연구 (Vibration Analysis of a Rolling Piston Type Rotary Compressor)

  • 한형석;황선웅;이은섭
    • 한국정밀공학회지
    • /
    • 제20권6호
    • /
    • pp.205-213
    • /
    • 2003
  • This paper is concerned with a roiling piston type rotary compressor for air conditioning use. Vibration of the compressor is analyzed numerically and experimentally. Multibody dynamic analysis methods to predict the vibration is given. The compressor is modeled as a system composed of bodies, joints, and force elements. Experimental results are also shown to be compared with simulation results. A sensitivity study using different variables that affect the compressor vibration is also carried out. It is found that the mass of weight balancer plays an important role in acceleration.

분리형 인버터 에어컨의 운전조건에 따른 성능 연구 (A study on the performance of a split system inverter air-conditioner at different operation conditions)

  • 김만회
    • 대한기계학회논문집B
    • /
    • 제22권1호
    • /
    • pp.113-121
    • /
    • 1998
  • The performance evaluation of a residential split system inverter air-conditioner has been conducted analytically and experimentally at different system operating conditions. A simulation program for modelling an air-conditioning system which consists of a compressor, a condenser, a capillary tube, an evaporator and related attachments was developed on the basis of the Oak Ridge heat pump design model, MARK III. The accuracy of the simulation results for the compressor frequencies of 32, 68 and 79 Hz for the residential split system inverter air-conditioner has been estimated by comparing calculation results to the experimental data and parametric study has been performed to investigate the effect of design parameters and operation conditions on the system performance.

왕복동식 공기압축기의 소음 발생원 분석 연구 (Noise Source Evaluation for Reciprocating Type Air Compressor)

  • 이광길;최승주
    • 한국안전학회지
    • /
    • 제26권4호
    • /
    • pp.20-26
    • /
    • 2011
  • This paper is to investigate noise source for reciprocating type air compressors. The reciprocating type air compressors are widely used in the small and medium sized enterprise and many employees are affected and irritated by their noise during working. The investigation and analysis of the noise source were made according to the ISO 1680/1 and MIL-STD 7410-1 and noise evaluation of each part of compressors was made. Noise emitted from the intake and exhaust valve and the air receiver tank were dominant compared with those from other parts of compressor. Noise from the motor and the revolution of crank mechanism was negligible relatively with the noise sources as mentioned above.

AE 원신호 파형분석에 의한 에어컨 컴프레서의 상태 진단 (Condition Diagnosis of Air-conditioner Compressor by Waveform Analysis of AE Raw Signal)

  • 이감규;강익수;강명창;김정석
    • 한국정밀공학회지
    • /
    • 제21권11호
    • /
    • pp.125-129
    • /
    • 2004
  • For the diagnosis of compressor abnormal condition in air-conditioner, AE signal which is derived from wear condition, compressed air and assembly error is analyzed experimentally. The burst and continuous type AE signal occurred by metal contact and compressed air and AE raw signal of compressors were directly acquired in production line. After extracting samples according to waveforms, Early Life Test(ELT) is conducted and classified to normal and abnormal waveform. The efficient parameters of waveform pattern are investigated in time and frequency domain and the diagnosis algorithm of air-conditioner by Neural Network estimation is suggested.

공기압축기의 인터쿨러 선정을 위한 열교환기의 형상별 성능해석 (Comparison of Various Heat Exchanger Performances in order for Air Compressor Intercooler Application)

  • 유상훈;박상구;윤정필;정지환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.73-81
    • /
    • 2008
  • Intercooling and aftercooling are required in order to operate air compressor, these are conducted through air-cooled or water-cooled heat exchangers. This study aims to find more suitable type of heat exchanger as a water-cooled intercooler of air compressor. Comparative performance evaluation among fin-tube heat exchanger and shell-and-tube (S&T) heat exchanger having various tubes such as circular tube, spiral tube, and internally finned tube was conducted. Thermal-hydraulic performance of each heat exchanger type is evaluated in terms of temperature drop and pressure drop. The comparisons show that shell-and-tube heat exchangers may have similar and larger heat transfer capacity to the fin-tube heat exchanger if tube diameter is reduced and multiple pass is adopted. For these cases, however, compressed air pressure drop in shell-and-tube heat exchanger become much larger than that in fin-tube heat exchanger.

PWM 방식과 인버터 방식의 압축기를 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(냉난방 특성) (Experimental Study on Performance Evaluation of System Air-Conditioner using Compressor of PWM or Inverter Method (Cooling and Heating Characteristics))

  • 전용호;김대훈;허삼행;권영철;문제명;홍주태
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.738-743
    • /
    • 2003
  • In the present study, the heating and cooling characteristics of system air-conditioner using a PWM compressor or a BLDC inverter compressor are investigated by the psychometric calorimeter using air enthalpy method. Cooling and heating capacities, power inputs and COPs are measured at the low, moderate, high loads under the cooling and heating standard conditions. At cooling conditions, the capacity of the PWM system is larger than that of the inverter case. Due to large power input, however, low COPs are measured under total load ranges. At heating conditions, the capacity of the PWM method is a little larger than that of the inverter case, except high load range. Since power input is low, large COPs are measured at moderate and high load ranges, which are different from cooling data. This shows that the PW system compared with the inverter case has good energy consumption efficiency at moderate and high load ranges except low load range. And when the system A/C is operated under the cooling and heating standard conditions, COPs are nearly uniform at total load ranges.

웨이브 와셔 스프링의 강성치에 관한 연구 (A Study on the Stiffness of Wave Washer Spring)

  • 이수종;왕지석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권3호
    • /
    • pp.74-81
    • /
    • 1996
  • The wave washer springs are widely used in non-return valves of fluid, especially in air check valves to confirm the rapid shut-off of valve propers. The stiffness of wave washer springs used in suction and exhaust valves of reciprocating air compressor play an important role on efficiency of the compressor. If the stiffness of the spring is too high, the pressure differences necessary to open the valves become high and the volumetric efficiency of cylinder decreasse. If the stiffness of the spring too low, the valve can not be closed rapidly and the inverse flow of air can take place. So, the optimum stiffness of valve spring is very important and it will be very helpful that the stiffness of wave washer springs to be used in suction and exhaust valves can be calculated in design stage of air compressor. In this paper the formula for calculating the spring constant of wave washer spring is introduced using bending and torsion theory of frames. The experiments are also carried out to measure the spring constants of several samples. It is proven that the calculated spring constants of wave washer springs are coincided well with measured values and that the formula presented in this paper for calculating the spring constants of wave washer spring is very useful for design of valves used in reciprocating air compressor.

  • PDF

선회스크롤의 편심질량을 고려한 스크롤압축기의 성능해석 (Performance analysis of scroll compressor considering eccentric mass of orbiting scroll)

  • 박승철;이진갑
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.605-614
    • /
    • 1999
  • Orbiting scroll mass center is different from the basic circle's for the normal involute profile. As for the orbiting scroll balanced conditions, the dynamic modeling are set up. The influences on sealing, reaction forces between the moving elements and forces from the moving elements to the compressor frame are analyzed in this paper. The simulation and experiment results are presented.

  • PDF

The Influence of the Vane on the Lubrication Characteristics Between the Vane and the Rolling Piston of a Rotary Compressor

  • Cho, Ihn-Sung;Jung, Jae-Youn
    • Journal of Mechanical Science and Technology
    • /
    • 제20권12호
    • /
    • pp.2242-2249
    • /
    • 2006
  • The rolling piston type rotary compressor has been widely used for refrigeration and air-conditioning systems due to its compactness and high-speed operation. The present analysis is part of a research program directed toward maximizing the advantages of refrigerant compressors. The study of lubrication characteristics in the critical sliding component is essential for the design of refrigerant compressors. Therefore, theoretical investigation of the lubrication characteristics of a rotary compressor being used for refrigeration and air-conditioning systems was investigated. The Newton-Raphson method was used for a partial elastohydrodynamic lubrication analysis between the vane and the rolling piston of a rotary compressor. The results demonstrated that the vane thickness and the center line position of the vane significantly influenced the friction force and the energy loss between the vane and the rolling piston.