• 제목/요약/키워드: Air vent

검색결과 162건 처리시간 0.031초

분류식 하수관거로의 전환시 유입하수의 성상 변화 및 선회와류식 SBR공법의 처리 특성 (Change in Influent Concentration of Domestic Wastewater from Separated Sewer and Biological Nitrogen and Phosphorus Removal of a Full Scale Air-vent SBR)

  • 이장희;강호
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.63-70
    • /
    • 2012
  • This study was carried out to investigate change in influent concentration of domestic wastewater flowed from a newly constructed separate sewer system (SSS) and biological nutrients removal efficiency of a full scale Air-vent sequential batch reactor (SBR, $600m^3/d$). The average concentration of $BOD_5$, SS, T-N and T-P from SSS were 246.5 mg/L, 231.6 mg/L, 42.974 mg/L, 5.360 mg/L, respectively which corresponds to 2.2times, 1.2times, 1.8times and 2.1times higher than those from the conventional combined sewer system (CSS). The removal efficiency of $BOD_5$, SS, T-N, and T-P for the Air-vent SBR operated with influent from SSS averaged 99.1%, 99.0%, 91.2%, and 93.5%, respectively. Especially the respective nitrogen and phosphorus removal was 15% greater than that of the SBR operated with influent from CSS. Simultaneous nitrification and denitrification (SND) was observed in an aerobic reactor(II) as a result of DO concentration gradient developed along the depth by the Air-vent system. In order to achieve T-N removal greater than 90%, the C/N ratio should be over 6.0 and the difference between $BOD_5$ loading and nitrogen loading rate be over 100 kg/day (0.130 kg $T-N/m^3{\cdot}d$). Even with high influent T-P concentration of 5.360 mg/L from SSS (compared with 2.465 mg/L from CSS) T-P removal achieved 93.5% which was 15.5% higher than that of the SBR with influent from CSS. This is probably due to high influent $BOD_5$ concentration from SSS that could provide soluble carbon source to release phosphorus at anaerobic condition. In order to achieve T-P removal greater than 90%, the difference between $BOD_5$ loading and phosphorus loading rate should be over 100 kg /day (0.130 kg $T-N/m^3{\cdot}d$).

모델링 기반의 선회와류식 SBR 공법이 적용된 하수처리장 및 마을하수도 동절기 총인 개선방안 연구 (Analysis on Retrofit Method to Improve TP treatment efficiency in Air-vent SBR process installed MWTP and RCSTP during winter based on Modeling)

  • 이현섭;임지열;길경익
    • 한국습지학회지
    • /
    • 제21권4호
    • /
    • pp.251-256
    • /
    • 2019
  • 상수원의 상류 및 인근 지역의 경우, 개발 제한으로 인해 상대적으로 하수도 보급률이 낮은 지역이 많다. 이는 지속적으로 상수원 오염에 영향 미치며 이를 방지하기 위한 방안으로 하수도 보급 및 기존 시설의 개선 등의 방안이 제시되고 있다. 본 연구에서는 안동댐과 임하댐 상류에 위치하고 있으며, 선회와류식 SBR공법이 도입된 A하수처리장 모델링을 통해 동절기 마을하수도 방류수 수질 개선 방안을 마련하기 위한 연구를 실시하였다. 5년(2012년 ~ 2016년)간의 운전자료를 바탕으로 모델 구축·검증을 실시하였다. 모델링 결과, SRT 조절을 통해 동절기 방류수 수질 개선이 가능할 것으로 분석되었으며, 각 방류수 수질 기준 별 개선 효과는 BOD 1.8%, COD 54.5%, SS 4.3%, T-N 0.8%, T-P 7.7%로 나타났다. 본 연구를 통해 도출된 동절기 하수처리장 방류수 수질 개선을 위한 방안은 유사한 공법이 도입된 하수처리장 및 마을하수도의 운영 개선방안으로 활용될 수 있을 것으로 판단된다.

방진고무사출성형의 적정설계 (Optimum Design of Rubber Injection Molding Process for the Preparation of Anti-vibration Rubber)

  • 임광희
    • Korean Chemical Engineering Research
    • /
    • 제48권4호
    • /
    • pp.490-498
    • /
    • 2010
  • K사의 방진고무 사출성형에 있어서 애로사항인 토크로드부시(torque rod bush)의 캐비티 가장자리(edge) 구간에서의 에어트랩(air-trap) 발생 및 다이내믹 댐퍼(dynamic damper)에 있어서 사출시 미성형(short shot) 발생 등의 문제점을 해결하기 위하여, 상용 CAE 프로그램인 MOLDFLOW(Ver. 5.2)를 이용한 전산모사를 수행하여 적정금형설계를 도출하고 적정작업조건을 구축하였다. 그 결과 방진고무 중에서 토크로드부시의 사출성형에서의 에어트랩 발생 등의 공정문제를 최적 캐비티 가장자리 경사각 및 게이트 수를 조절함으로써 캐비티 가장자리에서의 유동선단(flow-front)의 유동정체를 방지하고 유동을 원활하게 하여 해결하였다. 한편 다이내믹 댐퍼의 사출시 충전(filling) 단계에서의 캐비티 비충전으로 인한 미성형 불량은 에어벤트(air-vent) 구를 에어트랩 발생 빈도가 매우 높은 유동선단 상향류와 하향류의 두 흐름이 만나는 지점에 설치함으로써 미성형 불량을 해결하였다. 또한 게이트 위치를 댐퍼 상단에서 중단으로 변경하거나 게이트 수를 증가시킨 경우에 미성형 불량이 K사의 경우보다 개선되었다.

사각 컵 배터리 케이스 바닥 벤트 성형을 위한 단조 금형 설계 (Forging Die Design for Vent Forming of Square Cup Battery Case)

  • 이상훈;권순호;정훈;홍석무
    • 한국산학기술학회논문지
    • /
    • 제18권6호
    • /
    • pp.330-335
    • /
    • 2017
  • 최근 자동차 산업에서 전기 모터 연료 전지에 대한 수요가 급증했으며, 연료 전지 케이스로 사용되는 사각형 알루미늄 캔에 대한 수요 또한 증가하고 있다. 직사각형 배터리 케이스의 바닥에 있는 에어 벤트는 비정상적으로 높은 압력이 발생할 때 미리 압력을 방출하여 큰 폭발을 방지하는 역할을 한다. 직사각형 컵 배터리 케이스는 6 단계의 다단계 딥 드로잉으로 외형을 만들고 직사각형 배터리 케이스와 용접하여 벤트 부품을 제작해왔다. 그러나 본 연구에서는 직사각형 케이스의 바닥면에 공기 벤트 형상을 직접 추가 하는 연구를 수행하였다. 단조의 초기 형상으로는 사각 컵 다단식 딥 드로잉 성형 해석에서 추출한 두께와 형상을 이용한 유한 요소 해석 기법을 사용 하였다. 그 결과, 예측 정밀도가 향상되고, 배부름 및 파단 등의 결함을 미리 예측할 수 있었다. 초기 분석 결과를 토대로 두 가지 단조 형상이 후보로 제시되었고 성형 해석을 통해 최적의 단조 형상을 결정 하였다. 이러한 결과를 바탕으로 금형을 제작하고 실제 결과와 분석 결과를 비교하여 본 연구의 타당성을 검증하였다.

이중 바닥 온돌 시스템의 응용에 관한 이론적 분석 (Theoretical Analysis on the Applications of the Double-Floor Ondol System)

  • 최원기;이강영;이현근;서승직
    • 설비공학논문집
    • /
    • 제19권5호
    • /
    • pp.355-363
    • /
    • 2007
  • The Korean traditional 'Ondol' system has been a target for innovation to meet the requirements of sustainable domestic building and low carbon emission energy utilization. Simulation techniques provide designers and researchers with powerful tools to predict heating load and thermal behaviour of Ondol systems installed in various contexts. However, there are few studies on Ondol models, especially associated with multi-stories buildings of which type covers about 50% of Korean housing stock. In this study, we analyzed the double floor Ondol system on the multi-stories buildings using the ESP-r program. On the basis of the double floor Ondol system, we suggested the new modelling method that is composed of the Vent zone and Ondol zone. Using the this model, sensitivity analysis was carried out to refine the applicability of the model taking account of control conditions, constructions, air change and air flow network method and CFD analysis using the FLUENT. The air layer has enough temperature to use in heating zone. It is suggested that the simplicity of the model will allow building designers and mechanical engineers easily to implement scenario-based assessments of design options as well as control strategies. Later, we will simulate the real buildings and analyze the air distributions using the Fluent according to the various conditions.

바닥의 위치가 Vortex Vent의 배기성능에 미치는 영향 (Effect of the Floor on the Ventilation Performance of the Vortex Vent)

  • 이진원;임영복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.154-158
    • /
    • 2009
  • The vortex ventilation system (VV) which uses a rotating finned swirler installed coaxially with the exhaust duct is a very effective local ventilator. VV can enhance the capture depth by a factor of 3-5 compared to the conventional exhaust hood, in the absence of any solid walls nearby. In real situations there may exist ceiling, side wall and floor, all of which can affect the flow field and suction performance by way of the no-slip condition on the walls. 3D CFD simulation was performed in order to see the effect of the floor on the capture performance of the VV. The presence of floor reduced suction flow velocity, and increased the critical rotational speed which is the rotational speed required for stable vortex formation. Flow velocity profile along the axis could be well approximated by a universal functional form when the distance from the exhaust inlet is non-dimensionalized by the distance to the floor. Capture depth, define by the distance from the exhaust inlet to a point of velocity decreased to 10% of that at the inlet, is reduced by about 10% when the floor distance is 6 times the exhaust hood diameter.

  • PDF

카본블랙 제조공정의 안전성 향상에 관한 연구 (A Study on the Safety Improvement of Carbon Black Manufacturing Process)

  • 주종율;정필훈;이성은
    • 대한안전경영과학회지
    • /
    • 제25권4호
    • /
    • pp.153-161
    • /
    • 2023
  • Carbon black is a material in the form of fine black powder obtained by incomplete combustion or pyrolysis of hydrocarbons, and is composed of 90-99% carbon, and the rest is composed of hydrogen and oxygen. In the event of an emergency during the manufacture of carbon black, the generated tail gas should be safely discharged through an emergency line to prevent fire, explosion, and environmental pollution accidents caused by the tail gas. If the pressure continues to rise, the pressure control valve shall operate and the rupture plate shall be ruptured sequentially and the tail gas shall be discharged to the vent stack through the emergency line. As an emergency emission system, even if some untreated substances in the tail gas are released into the atmosphere, they are lighter than air, so it is safe to discharge them to a safe place through the Vent Stack. If the gas pressure is rising or worse, it is discharged from the Vent Stackine, and discharging fuel.

지붕 환기팬이 설치된 단동 플라스틱 온실에서 개선된 측창형태가 하우스 내 온도 및 참외 수량에 미치는 영향 (Effects of an Improved Side Vent on Yield of Oriental Melon and Temperature in Single-span Plastic Greenhouse with Roof Ventilation Fans)

  • 유인호;조명환;류희룡;신영안
    • 생물환경조절학회지
    • /
    • 제26권4호
    • /
    • pp.283-290
    • /
    • 2017
  • 본 연구에서는 저온기에 참외재배 단동 플라스틱 온실에서 지붕 환기팬을 이용하여 환기할 때 작물에 스트레스를 적게 주면서 바깥 공기를 하우스 내부로 균일하게 유입할 수 있는 방법으로 하우스 전체길이에 대해 측창안쪽부분에 비닐을 부착하는 방법을 개발하였다. 지면으로부터 측창이 최대한 열렸을 때 높이의 10cm 아래까지 비닐을 설치하였다. 측창 개선에 의한 온실 환경 개선 및 참외 수량증대 효과를 검증하기 위하여 개선 측창형태와 관행의 측창형태를 비교하였다. 2017년 2월 25일 까지는 두 시험구 모두 환기를 하지 않았는데, 2월 중순 하우스 내 기온이 $40^{\circ}C$를 넘어섰다. 따라서 2월 중순부터는 하우스 환기를 시작해야 할 것으로 판단된다. 대조구에서의 기온이 4월 하순부터 $30^{\circ}C$를 넘어섰다. 그러므로 측창 안쪽에 부착한 비닐을 4월 하순, 늦어도 5월 상순에는 제거해야 할 것으로 판단된다. 4월 중순에 처리구에서의 지온은 생육 적온 범위인 $20^{\circ}C$를 넘어선데 비해 대조구에서는 여전히 $20^{\circ}C$보다 낮게 나타났다. 4월 하순이 되어서야 대조구의 지온도 $20^{\circ}C$를 넘어서는 것으로 나타났다. 전기사용량은 처리구 47.2kWh, 대조구 48.3kWh로 처리 간에 큰 차이를 보이지 않았다. 처리구에서의 참외 상품수량은 5,094kg으로 대조구 4,113kg에 비해 23.9% 많았다. 상품과율은 처리구 73.5%, 대조구 73.9%로 차이가 없었다.

직화구이 음식점 방지시설의 오염물질 저감 효과 평가 - 전기집진방식을 중심으로 - (Evaluation of Removal Efficiency in Emission Pollutants by Air Pollution Prevention Facilities from Meat Grilled Restaurants - Focus on the Electrostatic Precipitator -)

  • 서장원;김영일;이희선;김지훈;김영두;신진호
    • 한국입자에어로졸학회지
    • /
    • 제17권4호
    • /
    • pp.115-123
    • /
    • 2021
  • The emission gas from meat grilled restaurants has unpleasant odor and sticky particulate matters (PM) in form of oil mist. This affects the residents living nearby. In oder to decrease the odor and PM, electrostatic precipitators (ESP) were installed at several restaurants by support of Seoul metropolitan government and emission characteristics of PM and odor were investigated. The removal efficiency of odor and PM at before- and after-ESP was that total hydrocarbon (THC), NH3, H2S, acetaldehyde, butyraldehyde were not much decreased. Total suspended particles (TSP) emitted from the vent was below the value of 7 mg/m3 regardless of the concentration of before-ESP and removal efficiency was in the range of 64 ~ 86%. The ratio of PM1.0 to PM10 of emission gas was over 0.9. So it was revealed that most PM of emission gas was PM1.0. The PM concentration in the air of the street near the vent was higher than another street due to the emission gas and the PM of indoor air of restaurant grilling meats was measured very high compared to outdoor air. So it needs more powerful ventilation of indoor air.

알루미늄합금 다이캐스트 주조기술 고도화(I);주조방안 선정 기술 (High Casting Technology for Aluminium Alloy Die Casting (I))

  • 김억수;이광학
    • 한국주조공학회지
    • /
    • 제18권3호
    • /
    • pp.211-221
    • /
    • 1998
  • 주조방안이란 주형(금형)에 공동부를 어떻게 설계하고 공동부의 어떤 위치에 어떻게 탕도, 탕구 등을 설계할 것인지, 또 over-flow 및 air-vent는 어떻게 설계하여 가스뽑기 및 용탕을 공동부에 원활히 충진시켜 완전한 제품을 얻을 수 있을까에 대한 제반적인 주조방법의 계획이다. 즉, 용탕을 공동부에 충진시키는 시스템이며, 주조상에 발생하는 제문제 및 주조제품의 품질에 가장 큰 영향을 미치는 요소 중의 하나이다. 따라서 만약 주조방안 시스템이 부적절하여 불량률이 높은 경우에는 대폭적인 금형수정이나 경우에 따라서는 불가피하게 금형을 신작해야 하는 큰 문제도 야기될 수 있다. 또한 기본적인 품질문제로 탕회, 탕경, 크랙 등의 외관불량과 기동 등의 내부결함, 내압불량등도 유발될 수 있다. 그러나 이러한 불량대책으로 쉽게 주조방안을 수정하는 것은 주조 시스템 자체가 변해버리기 때문에 피해야 하며 다른 대책을 선행하여 해결할 수 없었을 때 최종적으로 신중히 검토 후 주조방안을 수정하는 것이 바람직하다. 따라서, 본고에서는 Al합금 다이캐스트 주조기술에 있어 주조품질을 결정하는 중요한 요소인 주조방안의 효과적인 설계를 위한 주조기 선정, 금형분할면 선정, 탕구계의 설계와 탕구선정, over-flow 및 air-vent설계, 수축여유 및 금형냉각방안 선정기술에 대한 기본적 방안을 제시하고 실제 주조방안의 대표적인 사례를 소개하고자 한다.

  • PDF