• Title/Summary/Keyword: Air vent

Search Result 162, Processing Time 0.024 seconds

CFD Analysis on the Internal Air Flow Control in a Wax Spin Coater of Silicon Wafer Polishing Station (실리콘 웨이퍼 연마장비용 왁스 스핀코팅장치의 내부기류 제어에 관한 전산유동해석)

  • Kim, Kyoung-Jin;Kim, Dong-Joo;Park, Joong-Youn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • In this paper, the air flow induced by the rotating flat disk is numerically investigated in a hope to better understand the air flow structures inside the wax spin coater for a silicon wafer polishing station. Due to the complex inner geometry of actual spin coater such as the casing around the rotating ceramic block and servo motor, recirculation of air flow is inevitably found on the coating target if the internal space of spin coater is closed at the bottom and it could be the possible source of contamination on the wax coating. By numerical flow simulation, we found that it is necessary to install the air vent at the bottom and to apply the sufficient air suction in order to control the path of air flow and to eliminate the air recirculation zone above the spinning surface of coating target.

The Milling Characteristics of Cutting Type Rice Milling Machine Depending on the Number of a Cutting Roller's Air Vent and Blowing Velocity (절삭식 정미기의 절삭롤러 통풍구 수와 송풍속도에 따른 정백특성)

  • Cho, Byeong Hyo;Kang, Sin Hyeong;Won, Jin Ho;Lee, Hee Sook;Kang, Tae Hwan;Lee, Dong Il;Han, Chung Su
    • Food Engineering Progress
    • /
    • v.21 no.2
    • /
    • pp.110-115
    • /
    • 2017
  • This study aimed to identify milling characteristics depending on the number of a cutting roller's air vent and blowing velocity to remove rice bran by the cutting type milling machine which can minimize the conventional milling process. The level of whiteness was found to be $38{\pm}0.5$ in all the conditions, showing consistent whiteness levels during milling. The rice temperatures turned out to be 15.4 and $14.6^{\circ}C$ which were rather low-level under the conditions of the cutting roller with 3 vents and blowing velocities of 35 and 40 m/s respectively. Cracked rice ratio was 2.13% under the conditions of the cutting roller with 3 vents and a blowing velocity of 35 m/s. Broken rice ratio showed the range of 0.762-0.869%, reflecting a low level. Turbidity after milling was decreased, as blowing velocity became faster. Energy consumption for milled rice production was decreased, as blowing velocity became faster. The optimum milling condition for cutting type milling machine depending on air vent number of cutting roller and blowing velocity was found to be 3 vents and 35 m/s.

Prediction of Flow Pattern inside a Power Condenser by Computer Modelling (전산모델에 의한 응축기내에서의 기체유동현상의 예측)

  • Seoul, Kwang Won;Lee, Sang Yong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.3
    • /
    • pp.238-248
    • /
    • 1988
  • The flow pattern inside the power condenser is generally known to be very complicated due to the phase change and turbulence effects as well as the effect of condenser geometry. In the present study, the flow pattern inside the power condenser was numerically simulated with a personal computer. The widely known CHAMPION 2/E/FIX(Concentration, Heat and Momentum Program Instruction Outfit, 2D/Elliptic/Fixed grid) computer code was modified for this purpose. The flow was asssumed to be two-dimensional and steady-state, and the tube bank was considered to be homogeneous porous medium. Simple turbulent diffusion coefficients based on the appropriate experiments were obtained for the computation. Through this analytical approach, the flow pattern could be predicted fairly well. The computational results also show that the location of the air vent plays an important key role in determining the efficiency of the condenser.

  • PDF

Sorbent Thermal Desorption/Gas Chromatography/Mass Selective Detection Method for Determination of Gaseous Polycyclic Aromatic Hydrocarbons in Indoor Air

  • Dai, Shugui;Zhang, Lin;Zhu, Tan
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.753-758
    • /
    • 1995
  • Thermal desorption/gas chromatography/mass selective detection method using Tenax cartridges for the determination of gaseous polycyclic aromatic hydrocarbons(PAH) is described. Glass fiber filter can collect only PAH in particulate. Gaseous PAH may penetrate the filter. Glass cartridge packed Tenax-GC was uses fur adsorption of gaseous PAH. The air of inhalation zone was collected fur 2-10 hours. Cartridges were thermally desorbed in the reverse direction to sample flow. The desorption conditions were as follows; desorption temperature; $300^{\circ}C$; desorption time; 20min; column head pressure; 30psi; inlet split vent; closed during desorption.

  • PDF

Evaluation of Air Quality Inside Passenger Car with Operating Air Quality System (공기질 조절장치 작동 승용차 내부의 공기질 평가)

  • 조완근;박건호
    • Journal of Environmental Science International
    • /
    • v.7 no.5
    • /
    • pp.573-580
    • /
    • 1998
  • This study examined the carbon dioxide ($CO_2$) pollution inside vehicles under low ventilation condition and evaluated the Air Quality System (AQS) for in-vehicle air quality using two techniques. The low ventilation condition is not recommended in order to keep oxygen-rich condition inside vehicles. Under the low ventilation condition, the in-vehicle $CO_2$ concentrations exceeded 1,000 ppm, the air qualify guidelines in the United States, Western Europe, and Japan, indicating more oxygen deficiency inside vehicles. On the contrary, with the AQS-on condition, the in-vehicle $CO_2$ concentrations were less than 1,000 ppm fer most of the driving time, indicating that the AQS could solve the problem of $CO_2$ accumulation inside vehicles under the low ventilation condition. The AQS test conducted by comparing carbon monoxide (CO) and volatile organic compound (VOC) concentrations inside two vehicles indicated that the AQS effectively decreased the in-vehicle concentrations by 21 to 36%, as compared to medium ventilation condition with the windows closed, the vent opened, and air conditioning on. In addition, The AQS test conducted by comparing the interior and exterior concentrations indicated that the AQS effectively decreased the in-vehicle concentrations by 18 to 31%, as compared to medium ventilation condition.

  • PDF

Design Improvement of Vent System for Korean Utility Helicopter's Anti-Explosion Fuel Tank (한국형 기동헬기 내폭발성 만족을 위한 연료 벤트 시스템 설계개선)

  • Kim, Joung-Hun;Kim, Chang-Young;Chang, Joong-Jin;Lee, Mal-Young;Shim, Dai-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.1
    • /
    • pp.76-81
    • /
    • 2014
  • Military helicopter is exposed to the enemy gun firing due to the low altitude flight of contour flight, hovering & nap of the Earth flight, therefore it has the high possibility to be exploded by the gun firing. Recently the Anti-ballistic requirement is required to get the high level of safety from gun firing in required operational capability. The first military utility helicopter of SURION has the Anti-ballistic requirement and explosion proof. In order to meet the requirement, OBIGGS is adopted for the first time in KUH. It is proven that Anti-Explosion capability is satisfied to requirement for improving vent system which was insufficiently designed in development period and related to Anti-explosion.

Development of the Hydraulic Inspection Method for Irrigation Pipeline Systems (관수로 시스템 수리진단 기법 개발)

  • Kim, Young-Hwa;Park, Ji-Sung;Cheong, Byong-Ho
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.251-254
    • /
    • 2003
  • For improving the flow capacity of pipeline system the hydraulic inspection method was developed conducting on-site with survey of pipeline facility such as diversion work, air vent, etc. and pipe network analysis. The pipe network analysis method determine pipe diameter with trial and error. The validity of the hydraulic inspection method proved adapting on S-district pipeline system.

  • PDF

Effect of Different Height of Side Vents on Microclimate in a Single-Span Greenhouse during Natural Ventilation (측창 개폐 높이에 따른 자연환기 단동온실의 미기상환경 비교 분석)

  • Kim, Seong-Heon;Kim, Hyung-Kweon;Lee, Si-Young;Kwon, Jin-Kyung
    • Journal of Bio-Environment Control
    • /
    • v.31 no.2
    • /
    • pp.90-97
    • /
    • 2022
  • This study was carried out to investigate the effect of side vent heights on temperature and relative humidity inside and outside the single-span plastic greenhouse (W: 7 m, L: 40 m H: 3.9 m) during natural ventilation. Four different heights (120, 100, 80, 60 cm) of the side vent were used as an experimental condition. Variations of temperature and relative humidity inside and outside the greenhouse and the differences between heights were compared by using one-way ANOVA. In the daytime, the difference in temperature between inside and outside the greenhouse was dropped from 14.0℃ to 7.1℃ as the side vent height increased. The temperature difference in the nighttime was less than 0.2℃ regardless of the height. One-way ANOVA on the temperature difference between heights presented that the statistical significance was founded between all of the combinations of height in the daytime. The difference in relative humidity between inside and outside the greenhouse was grown from -13.8% to -22.2% with a decrease in the side vent height. The humidity difference in the nighttime was less than 1% regardless of the height. One-way ANOVA on the humidity difference revealed that most of the side vent heights showed significance in the daytime but between 100 and 80 cm was not significant. It seemed because the external air became cooler during the experiment with a height of 80 cm. Conclusively, this study empirically demonstrated that the higher side vents resulted in the decrease of differences in temperature and relative humidity between inside and outside the greenhouse, and also the effect of side vent height was statistically significant. This study may be helpful for deciding the height of the side vent effective for controlling temperature and relative humidity in a single-span greenhouse during natural ventilation.

Methane Recovery and Carbon Dioxide Stripping by MEA Solution the Autocirculation Bubble Lift Column Reactor (내부순환식 기포탑 반응기 상에서 MEA (monoethanolamine) 용액에 의한 이산화탄소 분리 및 메탄회수)

  • Lee, In-Hwa;Kim, Sun-Yil;Park, Ju-Young
    • Applied Chemistry for Engineering
    • /
    • v.18 no.3
    • /
    • pp.239-244
    • /
    • 2007
  • For the simultaneous methane recovery and $CO_2$-stripping, we have been developed dual vent auto circulation bubble lift column reactor, and evaluate optimum conditions for monoethanolamine (MEA) solutions as a $CO_2$ absorbent. At the 5 wt% MEA solution, we investigated the pH change during $CO_2$-stripping and absorption reaction, $CO_2$-stripping rate with reaction time, methane recovery efficiency for various inflow rates of air, $CO_2$-stripping rate for flow liquid over flow height, and $CO_2$-stripping dependency on the temperature of absolvent solutions. The suggested optimum conditions for $CO_2$ recovery with MEA in the dual vent auto circulation bubble lift column reactor were 40 mm over flow liquid height, 1.5 L/min of air inflow rate, and $25^{\circ}C$ of absorbent solution temperature.