• 제목/요약/키워드: Air unit

검색결과 1,591건 처리시간 0.032초

실외기 토출 유량 증대를 위한 Shroud 형상 및 휀 위치 최적 설계 (Optimization of Shroud Shape and Fan Location for Increasing Exhaust Flow Rate of Air Conditioner Outdoor Unit)

  • 유기정;김유일;이관수;차우호
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.599-605
    • /
    • 2009
  • This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit by investigating the effects of fan location and shroud shape. To determine optimal design parameters, we investigated the exhaust flow rate by changing shroud height, fan height, fan guide height, and fan width. The 3rd order central composite design was performed to select three most important parameters affecting the exhaust flow rate. According to the result of response surface method, the exhaust flow rate of the optimum model increased by 6.25% compared to that of the base model.

신경망 이용 공조기 고장검출 및 진단 (Fault Detection and Diagnosis for an Air-Handling Unit Using Artificial Neural Networks)

  • 이원용;경남호
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1288-1296
    • /
    • 2001
  • A scheme for on-line fault detection and diagnosis of an air-handling unit is presented. The fault detection scheme uses residuals which are generated by comparing each measurement with analytical redundancies computed from the reference models. In this paper, artificial neural networks (ANNs) are used to estimate analytical redundancy and to classify faults. The Lebenburg-Marquardt algorithm is used to train feed forward ANNs that provide estimates of continuous states and diagnosis results. The simulation result demonstrated that the ANNs can effectively detect and diagnose faults in the highly non-linear and complex HVAC systems.

  • PDF

차륜형 대공포의 냉방기 최적화 설계 (Optimized Design of Air Controlling System in Air Defense Gun Systems of Wheeled Vehicle)

  • 전기현;이부환;이동희
    • 대한기계학회논문집B
    • /
    • 제37권11호
    • /
    • pp.1047-1051
    • /
    • 2013
  • 최신의 전투장갑차들은 통합형 공조장치를 선호하는 경향이 있음에도 불구하고 분리형 공조장치에 대한 필요성이 제기되고 있다. 본 연구에서는 특수목적용 장갑차량 및 군용규격이 요구되는 장갑차량의 냉방, 난방장치에 대한 연구로 상용 Fluent 를 이용한 유동해석을 통해 덕트 및 최적화 배치를 구현하였으며 실차을 통한 시험 수행으로 해석결과를 검증하고, 선정된 냉방 및 난방기의 유효성을 확인하였다. 기존 차량의 변경 모델이나 계열차량의 경우, 현재 선정된 모델의 부분 변경으로 가능하며, 차륜형 장갑차용으로 선정된 현재 모델의 유효성을 본 연구를 통해서 입증되었다.

피니싱 툴 유니트의 에어 임펠러 설계에 관한 연구 (A Study on the Design for the Air Impeller of a Finishing Tool Unit)

  • 최현진;강익수;이승용;장은실;박선명;최성대
    • 한국CDE학회논문집
    • /
    • 제20권3호
    • /
    • pp.312-319
    • /
    • 2015
  • The grinding and furbishing process as the finishing process for molds include the works such as the grinding, buffing, lapping and polishing among others. A finishing tool unit is applied to this finishing process for the burr, lapping, polishing and others of molds. A finishing tool unit can carry out the flexible machining, depending on the machining allowance for objects to be cut on the basis of the instrumental driving mechanism which enables the up, down, left and right floating, which is applied in link with the dedicated cutters and robot machining systems. This study selected the shape to increase the rotatory force of an impeller when air is discharged during the driving of a finishing tool unit, and reflected it to the impeller designing. In addition, the study analyzed each flow velocity and pressure distribution per air pressurization value and finally analyzed the rotating torque to suggest the optimal conditions in designing impellers.

인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구 (Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

사무공간의 통합유니트 구축에 관한 연구 (A Study on the Development of the Workspace Integrated Units)

  • 김선숙;이선우;김지현;양인호;김광우;김광우
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.704-713
    • /
    • 2005
  • The purpose of this study is to suggest the concept of an integrated unit and to develop integrated units considering the layout of luminaires and diffusers in workspace. An integrated unit can be defined as a planning unit which satisfies the environment comfort criteria of workspace. Integrating process of each unit was proposed by considering the current workspace planning process. Luminaire and diffuser types are classified by surveying the workspace of the domestic and foreign office buildings. Several lighting units and air-conditioning units were developed by visual and thermal simulation, and integrated units for various architectural module which satisfies the visual and thermal comfort criteria were drawn from those units.

냉기의 가치평가 및 냉방비 배분방법론 제안 (Suggestion of the Worth Evaluation of Cool Air and the Allocation Methodology of Cooling Cost)

  • 김덕진
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.201-208
    • /
    • 2009
  • Our government will make a plan regulating the cooling limit temperature of the summer season to 26 degree and the heating limit temperature of the winter season to 20 degree for energy saving. Where, the key point of this politic pursuit can be the charge system on heating and cooling cost. We have suggested new cost allocation methodology as a worth evaluation method in the precedent study, and preformed the worth evaluation and cost allocation on four kind of warm air produced from a heating system as an example. In this study, we applied the suggested method to four kind of cool air, and preformed the worth evaluation and cost allocation on each cool air. As a result, similarly to the precedent study, the more energy a customer saved, the more cooling unit cost decreased, and the more energy a customer consumed, the more cooling unit cost increased. From this analysis, we hope that the suggested methodology can offer a theoretical basis to the energy charge policy of government, and induce the spontaneous energy saving of consumers.

궤도차량 엔진용 공기정화기 검증에 관한 연구 (A Study on the Verification of Air Cleaning Unit for Engine of Tracked Vehicle)

  • 이일랑;김상부
    • 한국산업융합학회 논문집
    • /
    • 제23권3호
    • /
    • pp.445-452
    • /
    • 2020
  • The air cleaning unit of K00 IFV(or Infantry Fighting Vehicle) has important roles to make sure the engine of the vehicle works precisely as filtering foreign substances in the air such as dust and sands. The entire components including scavenge fan which is one of the important inner part of the air cleaning unit are developed so that we can produce it domestically and don't need to import it from P⁎⁎ Co., the original maker in United Kingdom. This paper introduces a few verification processes including cleaning efficiency and reliability. As this core unit has developed successfully the improvement of military strength and logistics support can be expected. And design capability, manufacturing skills, maintenance ability of tracked weapon system will be increased thanks to the accumulated technical knowledge obtained from this developing project. Foreign currency savings and reducing operational cost can be expected as well in military industry.

Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner

  • Lee, Keon-ho;Cho, Dong-woo;Kim, Hyemi;Song, Young-hak
    • Architectural research
    • /
    • 제19권4호
    • /
    • pp.101-108
    • /
    • 2017
  • The use of the air conditioner is increasing due to the rise of the outdoor temperature during summer, and the problems of the fire and the cooling performance deterioration are caused due to lack of maintenance of the outdoor unit. In particular, overall performance of cooling system and efficiency in outdoor units have been degraded due to an intake of high-temperature outdoor air thereby increasing cooling energy and operating cost. Thus, this study aimed to increase efficiency of outdoor units by evaporating and cooling intake air through mist spray at the intake port surface in the outdoor unit. The measurements results showed that total power consumption of misting outdoor unit compared to that of conventional outdoor units was reduced by 21% approximately, and total power consumption of the entire system including pump was reduced by 16.7%. In addition, the operating cost including water use was reduced by 13.5% approximately. In summary, if a mist-spray nozzle kit is installed in air-cooled outdoor units, the reduction in the usage of cooling energy and operating cost will be achieved without replacement of existing cooling systems or a large scale of repairs.

에어컨 실외기 토출그릴 형상 최적화 (A Study on the Optimization of Discharge Grille of Outdoor Unit of Air Conditioner)

  • 최석호;오세기;김현종;진근호;오시영;김병순
    • 설비공학논문집
    • /
    • 제23권11호
    • /
    • pp.726-732
    • /
    • 2011
  • The aerodynamic and aeroacoustic performance of discharge grille of outdoor unit of air-conditioner was investigated in this study. Discharge grille is one of outdoor unit's important parts to affect the flow rate and Overall Sound Pressure Level(OSPL). New type of discharge grille was suggested based on the results of numerical simulation. To simulate the flow pattern near the propeller fan, commercial flow solver FLUENT was used. Sliding mesh method was used for rotating propeller fan and initial condition for unsteady model was calculated by Multiple Reference Frame(MRF) method. To minimize the interaction noise between fan blade wake and discharge grille, new discharge grille has radial rib which is aligned with trailing edge of fan blade. And inclined radial rib was adopted for reducing flow rate drop in discharge grille. The optimization of inclined angle of radial grille was performed experimentally.