• Title/Summary/Keyword: Air to water

Search Result 6,158, Processing Time 0.033 seconds

The Concentrations of Endocrine Disrupter (PCBs and DDE) in the Serumand Their Predictors of Exposure in Korean Women (일부 한국 성인 여성들의 혈중 내분비계 장애물질 농도 및 그 노출요인의 연구)

  • 민선영;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.127-137
    • /
    • 2001
  • Polychlorinated biphenyls(PCBs) are halogenated aromatic compounds with the empirical formula $C_{12}$ $H_{10-n}$C $l_{n}$(n=1~10), and are a mixture of possible 209 different chlorinated congeners. PCBs were widely used as dielectric fluids for capacitors and transformers, plasticizers, lubricant inks and paint addirives. Once released into the environment, PCBs persist for years because they are so resistant to degradation. In addition to their persistence in the environment, PCBs in ecological food chains undergo biomagnification because of their high degree of lipophilicity. In 1970s, the worldwide production of PCBs was ceased and the import of PCBs was prohibited since 1983 in Korea. In spite of these actions, many PCBs seems to be still in use. The environmental load of PCBs will continue to be recycled through air, land, water, and the biosphere for decades to come. This study was conducted to measure the concentrations of PCBs in the serum samples of 112 women by GC/MSD and GC/ECD. The main results of this study were as follows. 1. PCBs were detected in all samples. The mean $\pm$SD levels of PCBs in the serum were 3.613$\pm$0.759 ppb, and median were 3.828 ppb. 2. The correlation coefficients of the concentrations of 13 PCB congeners were from minimum, 0.7913 to maximum, 0.9985, and all was significant(p=0.0001). The correlation coefficient between the concentrations of PCBs and p,p'-DDE was 0.9641(p=0.0001). 3. There was a positive association between age and PCBs' concentrations (simple linear regression ; $R^2$=0.86, $\beta$=0.08023, p<0.001). 4. There was a positive association between total lipids in the serum and PCBs' concentrations (simple linear regression ; $R^2$=0.7058, $\beta$=0.00486, p<0.001). 5. For possible predictors of PCBs and p,p' -DDE levels in the serum, age adjusted model (Y=$\beta$$_{0}$+$\beta$$_1$age+ $B_2$X) was applied. For BMI, major residential area, wether to eat caught fish by angling, where to eat caught fish by angling(by parents in the past), fish consumption, meat consumption, meat consumption, and dairy consumption, there was no association. For total conception frequency and lactation frequency and lactation period, there was negative association.ion.

  • PDF

Development of the PC Based Color Fish Finder (퍼스널 컴퓨터를 이용한 칼라 어군탐지기의 개발에 관한 연구)

  • 신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.3
    • /
    • pp.247-255
    • /
    • 1995
  • This paper describes a personal computer(PC) based color fish finder to improve some problem of the commercial one. The commercial fish finder has no function of the echo data logging and replaying. The authors developed two types of the PC based color fish finder. One is a master type composed of a PC, a digital input-output board, and analog to digital converting (A/D) board and an ultrasonic transceiver unit, the other is a slave type composed of a PC and an A/D board. To test the performances of the master type experiments were carried out in air and in a water tank. It is found that the designed master type fish finder displays very well an eight-colored echogram by one dot resolution to the left side of the PC monitor. Also, the depth of echo signal was corresponds very well to the range from the transducer to a target. The sampling interval of echo signal is about 0.1m and the time of A/D conversion is 30 $\mu$sec. On the other hand, to test the performances of the slave type a raw data of echo signals from a data logger was supplied directly or via RF transceivers to the slave type one. From this experiment, it is confirmed the slave type is useful to replay the echo signal from the data logger or a telesounder.

  • PDF

Development of Deterioration Prediction Model and Reliability Model for the Cyclic Freeze-Thaw of Concrete Structures (콘크리트구조물의 반복적 동결융해에 대한 수치 해석적 열화 예측 및 신뢰성 모델 개발)

  • Cho, Tae-Jun;Kim, Lee-Hyeon;Cho, Hyo-Nam
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.13-22
    • /
    • 2008
  • The initiation and growth processes of cyclic ice body in porous systems are affected by the thermo-physical and mass transport properties, as well as gradients of temperature and chemical potentials. Furthermore, the diffusivity of deicing chemicals shows significantly higher value under cyclic freeze-thaw conditions. Consequently, the disintegration of concrete structures is aggravated at marine environments, higher altitudes, and northern areas. However, the properties of cyclic freeze-thaw with crack growth and the deterioration by the accumulated damages are hard to identify in tests. In order to predict the accumulated damages by cyclic freeze-thaw, a regression analysis by the response surface method (RSM) is used. The important parameters for cyclic freeze-thawdeterioration of concrete structures, such as water to cement ratio, entrained air pores, and the number of cycles of freezing and thawing, are used to compose the limit state function. The regression equation fitted to the important deterioration criteria, such as accumulated plastic deformation, relative dynamic modulus, or equivalent plastic deformations, were used as the probabilistic evaluations of performance for the degraded structural resistance. The predicted results of relative dynamic modulus and residual strains after 300 cycles of freeze-thaw show very good agreements with the experimental results. The RSM result can be used to predict the probability of occurrence for designer specified critical values. Therefore, it is possible to evaluate the life cycle management of concrete structures considering the accumulated damages due to the cyclic freeze-thaw using the proposed prediction method.

Characteristics of Geomorphological Surface and Analysis of Deposits in Fluvial Terraces at Upper Reach of Soyang River (소양강 상류 하안단구의 지형면 특성과 퇴적물 분석)

  • 이광률
    • Journal of the Korean Geographical Society
    • /
    • v.39 no.1
    • /
    • pp.27-44
    • /
    • 2004
  • Upper reach of Soyang River at the northernmost area around Taebaek Mountains in South korea is profitable area to understand paleo-environment during the Quaternary such as tectonic process and climate change in the Korean Peninsula. This study explained paleo-environment affect to channel development by geomorphic distribution and characteristics of terrace surfaces, and analysis of deposits at 58 fluvial terraces in upper reach of Soyang River. Fluvial terraces were classified from T1 to T6. Most terraces are distributed on the point bar in meandering channel and one side along river valley. Terraces tend to decrease in number and superficial dissection rate to be higher and channel slope to be steeper if it takes long time from T1 to 6. The paleo-channel of Soyang River is supposed to be stronger meandering in period of T2 than T3. The weathering rind of gravel is generally thicker in older terrace, however, differs by contents of water and air in deposits. Based on the data of stratigraphy, grain size analysis, pollen analysis and rubification index in deposit, formation age of T5 terrace in Soyang River are estimated in MIS(Marine Oxygen Isotope Stage) 10, and T2 terrace are estimated in MIS 6.

A Study for the Development of BoreanNursing TheoT : A Humanistic Approach based on Shinhyung,- Naekyungpyun in Dongeuibogam (한국 간호이론 정립을 위한 연구 I-동의보감을 중심으로 본 인간관-)

  • 신경림
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.1
    • /
    • pp.141-155
    • /
    • 1997
  • The universe has its order of yang and yin : all creation are continuously generated, grow and die, which is the results of the harmonious operation by yang and yin. Among all creation, the human is one of the samjae(three bases of the world, which are heaved earth, and man) and he is from the combined sukhi(a superior khi) of yang and yin. And human life itself is basically a condensed jonghyul (life blood) and at the same time it is only a transient joining of sadae(the four elements of earth, air, fire and water). Yang and yin, the two axes of the world, therefore. are the most crucial and fundamental concept to explain the generation and extinction of alt creation, to understand people in time and space. to find out the reality of human life as an organism, and, at last, to observe the state of human health. If so, what is the most essential idea in yang and yin\ulcorner It is taegeuk(chungkhi) or tao(of one yang and one yin). If the property of heaven and earth is kongon, taegeuk is a khi and tao a principle. And it can be said that a human body is merely a union of hyung and khi, that human life is an essence of sambo, jeongkhishin, that human health is a harmoninzed coordination of yang and yin because it is from the combined sukhi of yang and yin. Hyung. a vessel for sambo, jeongkhishin, is at the bottom and shin is on the top : the personality and the disposition of individuals differ according to their working. Thus. on the basis of the above discussion. the following can be offered as some suggestions for Korean Nursing Theory. Though human beings are part of Nature, they are the most eminent microcosm among all creation. So, as a subjet for nursing, a person should be understood with khijok kyoryu rather than with logical thinking, then mutual trust between the patient and the nurse can be established. The health of a person depends on the harmony of yang and yin. To be healthy, a person should consider harmonization with Nature(including his surroundings) as well as a balanced human relationships in society. Moreover, it is crucial for each person to obtain hoshim as a method of mind control rather than to only treat the symptoms of disease.

  • PDF

A Study on the Effect of Moisture Content of Wood upon the Absorption on Zinc Chloride Solution (침지처리법에(浸漬處理法)있어서 목재함수량(木材含水量)이 염화아연 흡수율(吸收率)에 미치는 영향(影響))

  • Shim, Chong-Supp;Shin, Dong-So
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.133-134
    • /
    • 1982
  • This experiment has been made to investigate the absorption of watersoluble zinc chloride by Pinus densiflora S. et Z. at different moisture content, under soaking process, to decide the optimum content condition for the maximum absorption of zinc chloride by the wood tested and to investigate the concentration of zinc chloride affecting each moisture content of wood. Material was cut in the Dept. of Forest, College of Agr. S.N.U. Suwon, Korea. Sample was divided into sap and heartwood group and cut $2{\times}2{\times}2\;cm$ in size, having exact three dimensions, using the part of D.B.H. The numbers of sample were 20 pieces for each moisture content condition for both sap and heartwood. Especially, the samples were protected from exposure to keep moisture content in green condition. The ranges of moisture content tested were as the table 3 and 4. The conclusions were as follows: 1. With 3% zinc chloride solution, the rate of absorption decreased with the time increased, if the air seasoned Korean red pine (Pinus densiflora S. et Z.) was treated in steeping process. Initial absorption for 30 minutes was more than 50% of total absorpon for 24 hours. 2. Rate of absorption was same under the green condition, while rate of absorption under the moisture content 7 to 30% varied. 3. Although it was not quite proportional change in the absorption with the difference of moisture content, the great change in the absorption occured by seasoning. With exception sap green condition, sapwood twice more permeable than the heartwood in the oven dried condition and it has been observed the nearly same amount of absorption at the moisture content of 7%, 10% and 15% respectively in heartwood. 4. It was better from water in wood from view-point of absorption of zinc chloride solution, but it was difficult practically to obtain the smallest moisture content, and then it was decided that values of allowable moisture content, on the basis of mean absorption, were 15% to 20% in the sapwood, and in the heartwood, 10% to 15%. The mean absorption for each moisture content in the sap and the heartwood were as following. 5. In general, the concentration of zinc chloride after steeping was nearly same between moisture content and sap and heartwood respectively.

  • PDF

A Study on the Crease Recovery Behavior of Core-spun Yarn Woven Fabrics (코어방적사직물의 구김회복거동에 관한 연구)

  • Kwon Ok-Kyung;Sung Su-Kwang;Kim Hyo-Dae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.13 no.3 s.31
    • /
    • pp.259-267
    • /
    • 1989
  • In this paper, the fabric specimen undergoes repeated laundering under given condition. After this cyclic laundering was applied, the crease recoveries of the specimen were measured using shirley crease revovery tester in order to evaluate the effect of factors at given condition during crease deformation. 5 samples of grey plain cloth were desized, alkali-scoured, bleached, whased with water, and air-dried. All tests were made on samples preconditioned to $65\%\;RH\;and\;20^{\circ}C$. The experimental results were analysed statistically to relate crease recoveries and the properties of smaples, recovery periods (time) of crease. Furthermore, the crease recoveries of core-spun yarn woven fabrics were discussed in comparison with those values for $100\%$ combed cotton yarn woven fabric and $65\%$ polyester $35\%$ carded cotton blended yarn woven fabric. The results obtained are as follows; 1. Regardless of materials, remarkable decrease are observed in crease recoveries about 1-5 cycles of the repeated laundering, but slack decrease are observed in crease recoveries after 5 cycle of the re-peated laundering. 2. Crease recoveries ($\alpha$) of core-spun yarn woven fabrics are relate to recovery periods (t) of crease as follows; log$\alpha$=0.01415 log t+2.1168 ($r^2=0.94$) 3. Core-spun yarn woven fabrics were superior to $100\%$ combed cotton yarn woven fabrics and $65\%$ polyester $35\%$ carded cotton blended yarn woven fabric in crease recoveries. 4. Crease recoveries ($\alpha$) of core-spun yarn woven fabrics are relate to cover factor (CF), thickness (T) at pressure 0.5 $gf/cm^2$, weight (W) as follows; log$\alpha$=-0.3482 log CF-0.4924 log T-0.4727 W+2.4243 ($r^2=0.88$) 5. Crease recoveries ($\alpha$) of core-spun yarn woven fabrics are relate to 2HB/B, 2HB/W, $\sqrt[3]{B/W}$, WC/T which are concerning to formation of weared clothes and bending Iran formation behavior as follows: log $\alpha$=0.0091 2HB/B+0.4667 2HB/W+0.0185 $\sqrt[3]{B/W}$+0.0114 WC/T+1.8433 ($r^2=0.86$)

  • PDF

A Study on the Fire Prevention Activities and Suppression Measures of Utility-Pipe Conduit (지하공동구 화재예방활동 및 진압대책에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.63-68
    • /
    • 2010
  • Utility-Pipe Conduit is, Housing and city effectively accommodate what they absolutely need power, communications, gas, pipeline, water supply, drainage, energy facilities etc, according to expansion of urban infrastructure are derived, several ways to solve problems in, collection facilities in place are maintained and managed facility. If Utility-Pipe Conduit is damaged, as well as national security, because their impact on society as a whole, by introducing large vulnerability in the fire prevention activities and suppression measures and disaster for our situation by introducing measures, comprehensive analysis of the fire risk, it shall establish fire prevention activities and suppression through analysis of Utility-Pipe Conduit design, institutional issues, the problem of fire protection facilities, fire spread phenomenon etc. Because of Utility-Pipe Conduit is an enclosed place, so incomplete combustion due to lack of oxygen supply that there are problem such dark smoke, carbon monoxide etc, toxic combustion products and heat generation and visual impairment is an issue difficult to enter. As well as fire prevention activities, the fire In light of the particularity of the under ground than above ground fire, so this phenomenon is weak fire fighting that fire to become effective fire fighting tactics, basically it is necessary difficulty softening, non-burn softening and prevent combustion expansion of the cable is installed on the Utility-Pipe Conduit, having to considering the specificity of the response command system and relevant organizations to establish an on-site, Structural identification and other information gathering required to record of Response agencies, keep air conditioning system 24 hours and strengthening Virtual Total Training of Response agen

A Feasibility Study for a Stratospheric Long-endurance Hybrid Unmanned Aerial Vehicle using a Regenerative Fuel Cell System

  • Cho, Seong-Hyun;Cha, Moon-Yong;Kim, Minjin;Sohn, Young-Jun;Yang, Tae-Hyun;Lee, Won-Yong
    • Journal of Electrochemical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.41-51
    • /
    • 2016
  • In the stratosphere, the air is stable and a photovoltaic (PV) system can produce more solar energy compared to in the atmosphere. If unmanned aerial vehicles (UAVs) fly in the stratosphere, the flight stability and efficiency of the mission are improved. On the other hand, the weakened lift force of the UAV due to the rarefied atmosphere can require more power for lift according to the weight and/or wing area of the UAV. To solve this problem, it is necessary to minimize the weight of the aircraft and improve the performance of the power system. A regenerative fuel cell (RFC) consisting of a fuel cell (FC) and water electrolysis (WE) combined PV power system has been investigated as a good alterative because of its higher specific energy. The WE system produces hydrogen and oxygen, providing extra energy beyond the energy generated by the PV system in the daytime, and then saves the gases in tanks. The FC system supplies the required power to the UAV at night, so the additional fuel supply to the UAV is not needed anymore. The specific energy of RFC systems is higher than that of Li-ion battery systems, so they have less weight than batteries that supply the same energy to the UAV. In this paper, for a stratospheric long-endurance hybrid UAV based on an RFC system, three major design factors (UAV weight, wing area and performance of WE) affecting the ability of long-term flight were determined and a simulation-based feasibility study was performed. The effects of the three design factors were analyzed as the flight time increased, and acceptable values of the factors for long endurance were found. As a result, the long-endurance of the target UAV was possible when the values were under 350 kg, above 150 m2 and under 80 kWh/kg H2.

Pressure Loss across Tube Bundles in Two-phase Flow (2상 유동 내 관군에서의 압력 손실)

  • Sim, Woo Gun;Banzragch, Dagdan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.181-189
    • /
    • 2016
  • An analytical model was developed by Sim to estimate the two-phase damping ratio for upward two-phase flow perpendicular to horizontal tube bundles. The parameters of two-phase flow, such as void fraction and pressure loss evaluated in the model, were calculated based on existing experimental formulations. However, it is necessary to implement a few improvements in the formulations for the case of tube bundles. For the purpose of the improved formulation, we need more information about the two-phase parameters, which can be found through experimental test. An experiment is performed with a typical normal square array of cylinders subjected to the two-phase flow of air-water in the tube bundles, to calculate the two-phase Euler number and the two-phase friction multiplier. The pitch-to-diameter ratio is 1.35 and the diameter of cylinder is 18mm. Pressure loss along the flow direction in the tube bundles is measured with a pressure transducer and data acquisition system to calculate the two-phase Euler number and the two-phase friction multiplier. The void fraction model by Feenstra et al. is used to estimate the void fraction of the two-phase flow in tube bundles. The experimental results of the two phase friction multiplier and two-phase Euler number for homogeneous and non-homogeneous two-phase flows are compared and evaluated against the analytical results given by Sim's model.