• Title/Summary/Keyword: Air to water

Search Result 6,150, Processing Time 0.035 seconds

Thickening of Bulking Sludge using DAF (Dissolved Air Flotation) (DAF(Dissolved Air Flotation)를 이용한 팽화 슬러지 농축)

  • Kim Dong-Seog;Park Young-Seek
    • Journal of Environmental Science International
    • /
    • v.15 no.1
    • /
    • pp.77-84
    • /
    • 2006
  • An effective technique of sludge separation is required for excess sludge of sewage or wastewater plant. The separation of bulking sludge of paper manufacturing plant was studied using DAF(Dissolved Air Flotation) system. The effects of parameters such as nozzle type, A/S(air/solid) ratio. pressure, injection time of pressured water and saturation time were examined. The results showed that the best nozzle type was flat which had small orifice hole, The optimum A/S ratio and pressure were $7.070\times10^{-3}$(recycle ratio of pressured water $20\%$) and 5atm, respectively. Injection times of pressurized water around 20-25 sesc and flotation time of 30 min appeared to be optimal for the DAF operation. The order of performance of packing was 18 mm > 22 mm > 32 mm.

A Study on the Ozoflotation Process for Drinking Water Treatment (Ozoflotation 공정의 정수처리 적용에 관한 연구)

  • Kang, Tae Hee;Oh, Byung Soo;Lee, Hoon;Byun, Kyu Sik;Kwon, Soon Buhm;Sohn, Byeong Yong;Ahn, Hyo Won;Kang, Joon-Wun
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.528-534
    • /
    • 2005
  • Ozone, a powerful oxidant, is widely used to remove microorganisms, pesticides, taste and odor compounds effectively. Dissolved air flotation (OAF) has been known as an economical process for treating algae and low turbid water quality. An ozoflotation system, combining ozone and OAF processes, has a merit which can operate the ozonation and flotation process simultaneously in a single compartment. This study investigated the application of the ozoflotation process for advanced water treatment by carrying out the pilot-plant experiment. During the test, ozone microbubbles were generated through a OAF pump and many kinds of parameters were evaluated under several conditions, such as raw water flow rate and ozone dose. As a result of the test, the optimum operating conditions of ozoflotation were decided to be 1.2 mg/L ozone dose and about 34 minute Hydraulic retention time (HRT). Finally, it could be demonstrated that the ozoflotation system can effectively improve the drinking water quality.

Interfacial Wave Characteristics for Countercurrent Stratified Air-Water Flow in a Horizontal Pipe

  • Chung, Heung-June;Chun, Se-Young;Chung, Moon-Ki;No, Hee-Cheon
    • Nuclear Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.379-389
    • /
    • 1996
  • To experimentally investigate the several wave patterns for the horizontal countercurrent stratified air-water flow, a series of systematic experimental studies have been performed. The experiments are carried out in a horizontal pipe with 4m in length and 102mm in inner diameter. The oater and air superficial velocities vary from 0.0004 to 0.0204 and from 0 to 6m/s, respectively. The instantaneous water thickness is measured by parallel-wire conductance probes, and the wave field is recorded by high speed video camera. Also, to evaluate the wave effect on interfacial friction factor, the pressure drop is measured. Statistical data anal)sis is accomplished in order to obtain the fundamental wave parameters such as un amplitude, length and velocity, and spatial growth factor. By using these statistical parameters, the wave regime boundaries can be verified.

  • PDF

An Analysis of the Water Supply System with Pressurizing Tank (가압탱크를 이용한 급수시스템의 해석 및 최적화 연구)

  • Lee, T.W.;Kim, T.H.;Choi, D.H.;Kim, S.D.;Kim, J.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.93-102
    • /
    • 1994
  • It is the goal of this study to provide the essential data for design and operation of optimum water supply system. Experimental and theoretical analyses have been conducted for various parameters, for example, volume and air percent of pressurizing tank, pump speed and pressure range inside tank, etc. Pressure inside tank with time, flow rate, energy consumption rate and pump operation time have been obtained for design and operating parameters to optimize the components and to establish the operating method of system, and therefore to contribute to the development of technology from a point of view of the improvement of quality, the enhancement of system efficiency and the reduction of construction cost.

  • PDF

Effect of Storage Conditions on the Color and the Mechanical Properties of Fabrics dyed with Natural Dyes (천연염색 직물의 환경조건에 따른 변.퇴색 및 물성변화에 관한 연구)

  • 이미식;홍문경;김의경;배순화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.3
    • /
    • pp.617-628
    • /
    • 2001
  • Cotton and silk fabrics dyed with brazilein(Caesalpinia Sappan), berberine (Phellodendron Amurense), and shikonin(Lithospermum Erythrorhizon) were stored in the air, in the water, and under the ground for about one year. The change of the color, the flexibility, and the breaking strength were measured at the intervals of few weeks. The results are as follows; 1. The color of the fabrics changed most extensively in the fabrics that were under the ground, then in the order of the ones that were in the water, and in the air. The color of the fabrics changed to the achromatic color over the time. 2. The flexibility change among the dyes was similar. All the fabrics became stiff under the ground and in the water over the storage time. 3. In general, cotton and silk fabrics dyed with berberine showed better strength retention than the fabrics dyed with other substances. 4. The strength retention of cotton fabrics was high in the order of the fabrics which were in the air, in the water, and under the ground. Only minuscule change occurred in the strength of the cotton fabrics. The strength of the fabrics that were in the water and under the ground decreased remarkably after 30 weeks and 20 weeks respectively. 5. The strength retention of silk fabrics was high in the order of the fabrics which were in the air, under the ground, and in the water. In the air, the strength on silk fabrics decreased rapidly after 30 weeks. In the water, the strength of silk fabrics decreased more rapidly than that of the cotton fabrics. Under the ground, the strength retention of silk was higher than that of cotton.

  • PDF

Study Characteristics in Packed Tower of Liquid Desiccant Solar Cooling System Using Counter Flow Configuration

  • Rahmanto, R. Hengki;Choi, K.H.;Agung, B.;Sukmaji, I.C.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.168-174
    • /
    • 2009
  • High water vapour content in air can cause a number of problems as for human or surrounding materials. For human a high water vapour can create physiological stress, discomfort, and also can encourage ill health. While, the cause for the environment is can accelerate the corrosion of metals, accelerate the growth of spores and mould, can reduce the electrical resistance of insulators and etc. Desiccant systems have been proposed as energy saving alternatives to vapor compression air conditioning for handling especially the latent load and also sensible load. Use of liquid desiccants offers several design and performance advantages over solid desiccants, especially when solar energy is used for regeneration. The liquid desiccants contact the gas inside the packed tower of liquid desiccant solar cooling system and the heat transfer and mass transfer will occur. This thesis is trying to study the characteristics inside the packed tower of dehumidifier systems. This characteristics consist of mass transfer rate, heat transfers rate, human comfort and energy that consume by the system. Those characteristics were affected by air flow rates, air temperature and humidity, and desiccant temperature and all that variation will influence the performance of the systems. The results of this thesis later on can be used to determine the best performance of the systems.

  • PDF

Prediction of Climate-induced Water Temperature using Nonlinear Air-water Temperature Relationship for Aquatic Environments (지구기후모형 기온변화에 따른 미래 하천생태환경에서의 수온 예측)

  • Lee, Khil-Ha
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.877-888
    • /
    • 2016
  • To project the effects of climate-induced change on aquatic environments, it is necessary to determine the thermal constraints affecting different fish species and to acquire time series of the current and projected water temperature (WT). Assuming that a nonlinear regression between the WT at individual stations and the ambient air temperature (AT) at nearby weather stations could represent the best relationship of air-water temperature, This study estimates future WT using a general circulation model (GCM). In addition, assuming that the grid-averaged observations of AT correspond to the AT output from GCM simulation, this study constructed a regression curve between the observations of the local WT and the concurrent GCM-simulated surface AT. Because of its low spatial resolution, downscaling is unavoidable. The projected WT under global warming scenario A2 (B2) shows an increase of about $1.6^{\circ}C$ ($0.9^{\circ}C$) for the period 2080-2100. The maximum/minimum WT shows an amount of change similar to that of the mean values. This study will provide guidelines for decision-makers and engineers in climate-induced river environment and ecosystem management.

A Study on Improved Heating Performance of an Apartment Housing Unit (공동주택 세대별 난방 성능 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.69-74
    • /
    • 2016
  • Most hot water heating valves for apartments are constant-flow types, which limit the flow rate through an individual household for even distribution of heating water to other households. The constant-flow type is implemented by an on-off control. As a result, heating water is supplied intermittently and hence, indoor air temperature also fluctuates. Returning water temperature is also high, which reduces energy efficiency. To implement continuous feedback control, the indoor temperature dynamics was simulated to fit a measured temperature history by a state-of-the-art physical model. From the model, it was found that the most important disturbance is outdoor temperature and its effect on indoor temperature lasts about an hour. To cope with the slow response and the significant disturbance, a prediction control with proportional feedback is proposed. The control was found to be successful in implementing continuous heating water flow and improved indoor temperature control.

Development for Inserted Type Coling System in Computer (컴퓨터 내장형 냉각시스템 개발)

  • Lee, Hyeon-Yong;Im, Seon-Jong
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.11a
    • /
    • pp.399-404
    • /
    • 2009
  • The research for computer cooling system has been researched briskly at home and abroad. Most of computer cooling systems are the air cooling method using cooling fan. The air cooling system are most widely used for low cost and easy installation but have limits in cooling. The water cooling system are good for cooling efficiency but bad for installation. This paper presents the developing for cooling system to be inserted in computer using thermoelectric module.

  • PDF

Operation and Diagnosis of DAF Water Treatment Plant at Highly Turbid Raw Water (고탁도시 DAF 정수장의 운영 및 진단)

  • Kwon, Soon-Buhm;Ahn, Hyo-Won;Kang, Jun-gu;Son, Byong-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.191-200
    • /
    • 2004
  • DAF process has been designed considering raw water quality characteristics in Korea. Although direct filtration is usually operated, DAF is operated when the freshwater blooms occut or raw water turbidity become high. Pre-sedimentation iS prepared in case when raw water turbidity is very high by rainstorms. A main feature of this plant is that the operation mode can be changed (controlled) based on the characteristics of raw water to optimize the effluent quality and the operation costs. Treatment capacity (surface loading rate) and efficiency of DAF was found to be better than conventional sedimentation process. Moreover, low-density particles (algae and alum flocs) are easily separated while it is difficult to remove in sedimentation. One of the main concerns in adoption of DAF (Dissolved Air-Flotation) process is a high raw water turbidity problem. That is, DAF is not adequate for raw water, which is more turbid than 100NTU. In order to avoid this problem, pre-sedimentation basins are prepared in DAF plant to decrease the turbidity of DAF influent. For simulation of the actual operation, bench and full-scale tests were performed for highly turbid water conditions. Consequently, DAF process coupled with sedimentation is suggested that pre-sedimentation with optimum coagulation prior to DAF would be appropriate.