• Title/Summary/Keyword: Air to Air

Search Result 35,283, Processing Time 0.059 seconds

Experimental investigation of frictional resistance reduction with air layer on the hull bottom of a ship

  • Jang, Jinho;Choi, Soon Ho;Ahn, Sung-Mok;Kim, Booki;Seo, Jong Soo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.2
    • /
    • pp.363-379
    • /
    • 2014
  • In an effort to cope with recent high oil price and global warming, developments of air lubricated ships have been pursued to reduce greenhouse gas emissions and to save fuel costs by reducing the frictional resistance. In this study, reduction in the frictional resistance by air lubrication with air layers generated on the lower surface of a flat plate was investigated experimentally in the large water tunnel of SSMB. The generated air layers were observed, and changes in the local frictional drag were measured at various flow rates of injected air. The results indicated that air lubrication with air layers might be useful in reducing the frictional resistance at specific conditions of air injection. Accordingly, resistance and self-propulsion tests for a 66K DWT bulk carrier were carried out in the towing tank of SSMB to estimate the expected net power savings.

Estimation of PCDD/Fs Concentrations in Ambient Air Using Pine Needles as a Passive Air Sampler (PAS) (소나무 잎을 PAS로 이용하여 대기 중 PCDD/Fs 농도 추정)

  • Chun, Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.116-125
    • /
    • 2015
  • Objective: This study was carried out to use pine needles as a passive air sampler (PAS) for atmospheric polychlorinared dibenzo-p-dioxins/furans (PCDD/Fs). Methods: PCDD/Fs concentrations in ambient air ($C_a$, $pg/m^3$) and deposited pine needles ($C_p$, pg/g dry) were analyzed simultaneously from June 1 to December 31. Air samples were taken using two low volume PUF active air samplers with an overall average air volume of approximately $1,200Sm^3$. Pine needles were collected the end of December near the air sampler. PCDD/Fs was analyzed by HRGC/HRMs. Results: A good correlation was shown ($R^2=0.6357$, p=0.0001) between $C_a$ and $C_p$, but a better correlation ($R^2=0.7372$, p<0.0001) existed between the logarithm of octanol-air partitioning coefficient ($LogK_{oa}$) and Log($C_p/C_a$). The average PCDD/Fs sampling rates from air to pine needles were 0.045($0.018-0.185m^3/day-g\;dry$). Conclusion: It was found that pine needles can be used as PAS for atmospheric PCDD/Fs, and they are especially suitable for long time PAS compared to PUF disk PAS.

A Study on the Evaluation of Air Change Efficiency of Multi-Air-Conditioner with Ventilation System for Heating Season (환기시스템이 적용된 히트펌프의 난방시 급기효율 평가에 관한 연구)

  • Kwon Yong-Il;Han Hwataik;Kim Kyung-Hwan;Chung Baik-Young;Lee Gam-Gue
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.56-61
    • /
    • 2005
  • Indoor air quality becomes of a concern recently in view of human health. This study investigates the air diffusion performance and the air change efficiency of a classroom, when outdoor air is introduced in addition to the heating/cooling operation of a ceiling-mounted heat pump. A CFD analysis has been performed to investigate the effect of the discharge angle of the air jets from the heat pump for both parallel and series types of outdoor air system. It is observed that the series type creates more uniform indoor environment compared to the parallel type in general. It can be concluded the discharge angle should not be larger than 40o for the parallel type, in order not to generate thermal stratification in the room.

Performance Analysis of Summertime Heat Transfer Characteristics of the Double Skin Window for Plant Factory (식물공장 이중창호의 하절기 열전달 성능 분석)

  • So, Jae-Hyun;Kim, Woo-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.351-357
    • /
    • 2012
  • To reduce the summertime cooling load of a plant factory, a concept design was performed for the double skin window which utilizes the low temperature air from a ground coupled heat exchanger. The design parameters were selected as the number of cavity air inlet, the cavity thickness, the location of cavity air inlet, and the configuration of cavity air outlet. A parametric study was conducted in a systematic way to evaluate the heat transfer characteristics of the double skin window. As the number of cavity air inlet and the cavity thickness increase, the heat flux from outside air to indoor air was decreased. The effect of the location of cavity air inlet was not significant and the larger cavity air outlet area gave us relatively better heat blocking performance from outside hot air. This study demonstrated that it is possible to develop an improved double skin window by utilizing a ground coupled heat exchanger.

Breathing Zone Air Quality in Taegu (인체 호흡 영역에서의 대구시 대기질에 관한 연구)

  • 조완근;손상호
    • Journal of Environmental Science International
    • /
    • v.5 no.1
    • /
    • pp.7-14
    • /
    • 1996
  • Two experiments were conducted to evaluate breathing zone air quality in Taegu, using automatic analyzers for four air quality standards($SO_2$, $NO_2$, CO, and $O_3$). First, air target compounds were measured for 8 to 12 hours in each of two commercial areas and five residential areas. Second, air target compounds were hourly measured for 24 hours in each of two commercial areas, two residential areas, and an industrial complex area. Based on the first experiment the breathing zone air was more polluted in the commercial area as compared to the residential area, while the second experiment showed that the breathing zone air was polluted rather in the residential are3 as compared to the commercial area. The second experiment also indicated that there was some variation of breathing zone air concentration with time and measuring sites. Diurnal variation of breathing zone air concentrations was consistent with previous studies which measured at building height. The highest breathing zone air concentration was shown in Seongseo industrial complex area. An unusual finding of this study was that $SO_2$ concentration in the breathing zone air of Bisandong, a typical residential area of Taegu, was higher than that of other residential areas, even higher than that of Seongseo industrial complex area.

  • PDF

A Study on Area Planning of Air Conditioning Room for Hospital Design Focused on System (체계중심병원설계를 위한 공조실 면적 계획에 관한 연구)

  • Kim, Eun Seok;Yang, Nae Won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.27-35
    • /
    • 2019
  • Purpose: As the improvement in quality of medical environment and the spatial consideration for the prevention of infection in the hospital have become increasingly important in the recent years, specific and practical planning for air conditioning room's area has become a major issue accordingly. However, the air conditioning room tends to be discussed focusing on technical factors such as air conditioning systems that are irrelevant to building plans, while discussions of most departments related to the medical functions have actively taken placed. Therefore, this study aims to investigate the factors influencing the planning for the air conditioning room area, and through subsequent analysis of the area of the air conditioning room, to propose a way to improve effective planning for the air conditioning room area. Methods: This study examines the case hospitals that fall into two types: each floor supply system and concentrated supply system, and compares and analyzes the air conditioning room area-related factors and the characteristics of changes in the interior of air conditioning room before and after remodeling through air conditioning floor plan of those case hospitals. Results: The air conditioning room can be classified into the net area of the functional space such as duct passages, and the public area such as aisle space, and of those the public area is an important factor in calculating the area of the air conditioning room. The public area of the air-conditioning room should not be planned considering only the spaces for mobile passage or maintenance activities, but should be planned taking into account internal changes such as expansion and replacement of equipment in the future from the beginning. Implications: When planning a medical facility, it is used as basic data for the planning of the air conditioning room area, which is a significant fixed factor in the initial setting.

Analysis of MWIR and LWIR Signature of Supersonic Aircraft to Air-to-air and Surface-to-air Missile by Coupled Simulation Method (통합해석기법을 활용한 공대공 및 지대공 적외선 미사일 대응 초음속 항공기의 중적외선 및 원적외선 신호 분석)

  • Kim, Taehwan;Bae, Ji-Yeul;Kim, Taeil;Jung, Daeyoon;Hwang, Chang Su;Cho, Hyung Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.764-772
    • /
    • 2014
  • The stealth performance of supersonic aircraft in recent air battlefield is one of the most significant feature for latest fighters. Especially, as the technology is advancing, the IR stealth capability becomes more important because of its passive characteristic. To design an aircraft with stealth capability, we must know how much the IR signature is generated from the aircraft. Also, predicting the IR signature of enemy's aircraft is tactically crucial. In this study, we calculated MWIR and LWIR infrared signature of $5^{th}$ generation supersonic aircraft against air-to-air and surface-to-air threat using IR simulation code and CFD coupled procedure.

Air - drying calendars of 24 districts in Korea (우리나라 지역별(地域別) 천연건조(天然乾燥)캘린더)

  • Jung, Hee-Suk;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.16-22
    • /
    • 1986
  • Effective air-drying days for four seasons and districts were calculated from average monthly temperature, relative humidity and wind speed records for 24 districts in Korea and air-drying calendars were prepared. And these districts were divided into zones of effective air-drying days. These results were as follows. 1. Effective air-drying days for four seasons were 20 to 23 days in springtime, 30 days in summertime, 21 to 26 days in autumntime, and 8 to 17 days in wintertime. 2. Effective air-drying days variated from district to district and was 237 days, the shortest period, in Ch'unch$\breve{o}$n, and was 288 days, the longest period, in-S$\breve{o}$gwipo. 3. Effective air-drying days were primarilly related to the difference in temperature from month to month, and secondarily, especially in September, were related to the differences in relative humidity, and were not related to wind speed. 4. South Korea was divided into 4 zones of effective air-drying days and these zones had it little difference compared with meteorological zones.

  • PDF

Study of Via-Typed Air-Gap for Logic Devices Applications below 45 nm Node

  • Kim, Sang-Yong;Kim, Il-Soo;Jeong, Woo-Yang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.4
    • /
    • pp.131-134
    • /
    • 2011
  • Back-end-of-line using ultra low-k (ULK; k < 2.5) has been required to reduce resistive capacitance beyond 45 nmtechnologies, because micro-processing units need higher speed and density. There are two strategies to manufacture ULK inter-layer dielectric (ILD) materials using an air-gap (k = 1). The former ULK and calcinations of ILD degrade the mechanical strength and induce a high cost due to the complication of following process, such as chemical mechanical polishing and deposition of the barrier metal. In contrast, the air-gap based low-k ILD with a relatively higher density has been researched on the trench-type with activity, but it has limited application to high density devices due to its high air-gap into the next metal layer. The height of air-gap into the next metal layer was reduced by changing to the via-typed air-gap, up to about 50% compared to that of the trench-typed air-gap. The controllable ULK was easily fabricated using the via-typed air-gap. It is thought that the via-type air-gap made the better design margin like via-patterning in the area with the dense and narrow lines.

Quality Characteristics of Jeolpyun with Different Ratios of Loquat Leaf Powder (비파잎가루 첨가 비율에 따른 절편의 품질 특성)

  • Kang, Yang-Sun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.25 no.5
    • /
    • pp.842-849
    • /
    • 2015
  • The purpose of this study was to determine the optimal mixing ratio of hot-air dried loquat leaf powder and optimum conditions for making Jeolpyun containing hot-air dried loquat leaf powder (LLP). Samples of Jeolpyun were prepared with different contents of hot-air dried LLP (0%, 3%, 6%, 9%, 12%) followed by analysis of chemical properties, moisture contents, color, mechanical quality characteristics, amylograph, and sensory tests. Chemical analysis showed that hot-air dried LLP consisted of 11.41% water, 8.34% crude protein, 1.90% crude fat, 7.74% crude ash, and 16.95% crude fiber, with $^{\circ}Brix$ of 2.07, and pH of 5.78. Moisture contents of samples ranged from 52.22 to 50.06%. L-value decreased with addition of hot-air dried LLP, whereas a-value increased with increasing amount of hot-air dried LLP, and no significant differences were observed regarding b-value. In the mechanical evaluation of physical properties, hardness deceased with increasing amount of hot-air dried LLP. The starting temperature amylograph of Jeolpyun was higher in samples with hot-air dried LLP than those without hot-air dried LLP. Set back was slower with increasing amount of hot-air dried LLP, an increasing amount of hot-air dried LLP made set back of Jeolpyun slower. In the sensory test, Jeolpyun with 6% hot-air dried LLP was the most preferred with less bitterness and proper softness, moisture and chewiness. Therefore, addition of 6% hot-air dried LLP to Jeolpyun made with rice flour showed the best overall preference. Based on the results of this experiment, samples with hot-air dried LLP showed slower hardening than those without hot-air dried LLP in textural changes during storage, and Jeolpyun with 6% hot-air dried LLP is expected to increase quality and preference of Jeolpyun.