• Title/Summary/Keyword: Air stream

검색결과 494건 처리시간 0.037초

낙동강 유역 환경유량에 대한 기후변화의 영향 분석 (An Analysis of the Effect of Climate Change on Nakdong River Environmental Flow)

  • 이아연;김상단
    • 한국물환경학회지
    • /
    • 제27권3호
    • /
    • pp.273-285
    • /
    • 2011
  • This study describes the modeling of climate change impact on runoff across southeast Korea using a conceptual rainfall-runoff model TANK and assesses the results using the concept of environmental flows developed by International Water Management Institute. The future climate time series is obtained by scaling the historical series, informed by 4 global climate models and 3 greenhouse gas emission scenarios, to reflect a $4.0^{\circ}C$ increase at most in average surface air temperature and 31.7% increase at most in annual precipitation, using the spatio-temporal changing factor method that considers changes in the future mean seasonal rainfall and potential evapotranspiration as well as in the daily rainfall distribution. Although the simulation results from different global circulation models and greenhouse emission scenarios indicate different responses in flows to the climate change, the majority of the modeling results show that there will be more runoff in southeast Korea in the future. However, there is substantial uncertainty, with the results ranging from a 5.82% decrease to a 48.15% increase in the mean annual runoff averaged across the study area according to the corresponding climate change scenarios. We then assess the hydrologic perturbations based on the comparison between present and future flow duration curves suggested by IMWI. As a result, the effect of hydrologic perturbation on aquatic ecosystems may be significant at several locations of the Nakdong river main stream in dry season.

요소-멜라민수지로 접착된 파티클보드의 열압동안 포름알데히드 배출량 측정 (Measurement of Formaldehyde Emissions during Hot-Pressing of Particleboard Bonded with Melamine-Urea-Formaldihyde Resin)

  • 이종규;오용성
    • Journal of the Korean Wood Science and Technology
    • /
    • 제32권2호
    • /
    • pp.65-72
    • /
    • 2004
  • 요소-멜라민수지 접착제를 실험실에서 수지 접착제 고형분량에 대해 5% 멜라민을 첨가하여 파티클보드 제조용으로 합성하였다. 합성한 요소-멜라민 수지를 이용하여 전건 목재파티클의 무게에 대해 접착제 첨가량 6, 8%와 열압시간 3, 4, 5분에서 실험실 파티클보드를 접착하는 열압시간동안 배출되는 가스를 증류수에 용해·포집하여 얻어진 용액으로부터 포름알데히드 배출량을 미국 National Institute of Occupational Safety and Health (NIOSH) 3500의 방법에 의해 분석·비교하였다. 포름알데히드 배출량을 측정하여 분석한 결과는 파티클보드를 열압하는 시간동안 배출되는 가스 중에서 포름알데히드량은 요소-멜라민수지 접착제의 첨가량과 열압시간에 대해 통계적으로 유의하게 차이가 있다는 것을 보여줬다. 파티클보드의 성능평가 결과는 3분의 열압시간에서 접착된 파티클보드의 박리강도는 KS F 3104 파티클보드 8.0형의 최소요구치를 만족시키는 것을 보여줬다.

분수에서 생성되는 물입자의 확산과 냉각효과의 범위 예측 (A Study on Predicting the Range of Cooling Effect and the Diffusion of Water Particles that are Generated from a Fountain)

  • 이상득
    • 한국환경과학회지
    • /
    • 제20권7호
    • /
    • pp.819-828
    • /
    • 2011
  • This research was done to clarify the cooling effect of water particles generated from a fountain. This effect is a one way to control the heat island effect of big cities. The result of this research was drawn by setting the jets of water in a certain height, and then studying the diffusion of water particles, which is affected by the size of the particles and the wind speed, and the cooling effect caused by the diffusion. 1) When a diameter of a water drop was 500 ${\mu}m$ and the wind speed was 2.0 to 6.0 m/sec, the water drop diffused 75 to 190m, and the water vapor spread over 175 to 440 m. As a result, there was more than $0.5^{\circ}C$ of cooling effect on the temperature in the atmosphere 130 to 330m around the water fountain. 2) When a diameter of a water drop was 750 ${\mu}m$ and the wind speed was 2.0 to 6.0 m/sec, the water drop diffused 65 to 150 m, and the water vapor spread over 160 to 405 m. Moreover, there was more than $0.5^{\circ}C$ of cooling effect on the temperature in the atmosphere 110 to 275 m around the water fountain. 3) After studying on the relationship between the diameter of water drop and the wind speed, and the diffusion of water particles and the range of the atmosphere that was cooled, a result could be drawn from the research that the smaller the diameter of the water vapor gets and the faster the wind speed becomes, the wider the water particles diffuse and the cooler the atmosphere around the fountain becomes. 4) This research further extrapolates that when the ordinary water(tap water, water from river and stream) is used in a fountain, the cooling effect of the air near the fountain can be approached similarly. If the seawater is used in a fountain, there is to be more to concern not only on cooling effect on the air, but also on other effects on surrounding environment generated by the salt in seawater.

일반 공기 및 순산소 연소 조건에서 Fuel-NOx 생성 특성의 비교 (Comparison of Fuel-NOx Formation Characteristics in Conventional Air and Oxyfuel Combustion Conditions)

  • 우민호;박권하;최병철
    • 대한기계학회논문집B
    • /
    • 제37권5호
    • /
    • pp.481-488
    • /
    • 2013
  • 10 %의 암모니아가 첨가된 메탄 연료의 비예혼합 확산화염에서, 산소/이산화탄소 및 산소/질소의 산화제 내에 산소 비율의 변화에 따른 질소산화물($NO_x$)의 생성 특성을 실험 및 수치해석적으로 조사하였다. 동축류 제트 화염의 실험에서, 산소/이산화탄소의 산화제인 경우, 측정된 $NO_x$은 산소 비율의 증가에 따라 약간 증가하는 경향을 보였다. 반면에, 산소/질소의 산화제인 경우, $NO_x$은 0.7의 산소 비율에서 최대로 측정되었으며, 산소 비율에 따라 비단조적인 경향을 보였다. 결과적으로, 암모니아가 첨가된 메탄 화염에서 배출되는 $NO_x$는 일반 공기의 조건보다 순산소 연소 조건의 경우가 더 크게 측정되었다. 한편, 다양한 산화제의 조건에 대하여 $NO_x$ 생성 특성을 분석하기 위해서, 동일한 화학반응 메커니즘을 적용하여 1 차원 및 2 차원의 수치해석을 수행하였다. 그 결과, 산소/질소의 산화제에서 2 차원의 수치해석 결과가 실험적으로 측정된 $NO_x$의 배출 특성을 비교적 잘 예측하였다.

사용후핵연료 운반용기 덮개 내부 열전달 해석 (Heat Transfer Analysis around Transport Cask under Transport Hood)

  • 이동규;박제호;정인수;김태만;윤정현
    • 방사성폐기물학회지
    • /
    • 제9권3호
    • /
    • pp.161-167
    • /
    • 2011
  • 사용후핵연료 운반용기 표면온도가 $85^{\circ}C$를 초과할 경우, 대인용 보호막(Personnel Barrier) 또는 운반용 덮개(Transport Hood)를 설치하여 운반 중 운반용기 표면에 사람이 직접 접근할 수 없도록 하여야 한다. 운반용 덮개가 설치된 경우, 열적 안전성 평가의 한 가지 경우인 정상조건 열해석 시, 외부환경 경계조건(환경온도 및 외부복사온도)으로 적용하기 위해서 운반용 덮개 내부 열 환경 조건(내부 공기온도 및 운반용 덮개 표면온도)을 계산해야 한다. 따라서 본 연구에서는 운반용 덮개 내부 공기온도 및 표면온도를 계산하기 위한 해석적 방법 및 열전달 특성에 대한 분석을 수행하였고 CFD 해석 결과와 비교를 통해 타당성을 검증하였다.

온수로 및 온수지에서의 수온상승효과에 관한 조사연구 (An Observational Study on the Temperature Rising Effects in Water Warming canal and Water Warming Pond)

  • 홍종백;홍성범
    • 한국농공학회지
    • /
    • 제32권3호
    • /
    • pp.31-38
    • /
    • 1990
  • The power water flowed out from the multipurpose darn influences the ecosystem approximately because of the low water temperature. An appropriate counter measure to the rising water temperature is needed for growing crops especially when the temperature is below 18˚C in the source of the irrigation water This observational study is practiced in Yong-Doo water warming canal and pond in the down stream of Choong-Ju multipurpose dam and is practiced for analyse and compare the rising effects in actural water temperature by actual measurement with the rising effects of planned water temperatuer by the basic theoritical method and for the help to present the direction in plan establishment through investigate the results afterwards. The results are as follows. 1.The degree of the rise of the water temperature can be decided by $\theta$x=$\theta$o +K L--v.h (T-$\theta$˚)Then, K values of a factor representing the characteristics of the water warming canal were 0.00002043 for the type I. and 0.0000173 for the type II. respectively. 2.A variation of water temperature which produced by the difference effective temperature and water temperature in the water warming canal was $\theta$x1 = 16.5 + 15.9(1-e -0.00018x), $\theta$x2 =18.8 + 8.4( 1-e -0.000298x)for the type I. and $\theta$x, = 19.6 + 12.8 ( 1-e -0.00041x) for the type II. 3.It was shown that the effects of the rise of water temperature for the type I. water warming canal were greater than that of type II. as a resultes of broadening the surface of the canal compared with the depth of water, coloring the surface of water canal and installing the resistance block. 4.In case of the type I. water warming canal, the equation between the air temperature and the degree of the rise of water temprature could be made ;Y= 0.4134X + 7.728 In addition, in case of the type II. water warming canal, the correlation was very low. 5.A monthly variation of the water temperature in the water warming canal was the highest in August during the irrigation period and the water temperature rose with the air temperature until August. However, it was blunted after then. 6.A rising degree of water temperature of the practical value in the water warming pond was higher than that of the theoritical equation by 69% for the type I. and 57% for the type II. Accordingly, it was possible to acquire the result near the practical value.$\theta$w-$\theta$o=[1-exp{ -h(1+2$\psi$) . X($\theta$w-$\theta$0)XC Here, C values are 1.69 for the type I. and 1.57 for the type II. 7.It was shown that the effect of the rise of water temperature was favorable when the thermal absorption was to be good by coloring the surface of the water warming pond and removing the bottom osmosis. 8.By enlarging the surface of water in comparison with the depth, and by having dead area of water in the water warming pond, this structure in the water warming pond is helpful for the rise of water temperature.

  • PDF

DRUM impactor를 이용한 대기 입자상 물질 중 원소성분의 입경분포 특성 : 제주도 고산지역의 2002년 봄철 (3.29-5.30) 측정 연구 (Size Distributions of Trace Elements in Airborn Particulates Collected using Drum impactor at Gosan, Jeju Island : Measurements in Springtime 2002)

  • 한진석;문광주;류성윤;안준영;공부주;홍유덕;김영준
    • 한국대기환경학회지
    • /
    • 제20권4호
    • /
    • pp.555-569
    • /
    • 2004
  • Size -segregated measurements of aerosol composition using 8-stage DRUM impactor are used to determine the transport of natural and anthropogenic aerosols at Gosan site from 29 March to 30 May in 2002. Separation of ambient aerosols by DRUM impactor offers many Advantages over other standard filtration techniques. Some of the most important advantages are the ability to segregate into details by particle tire, to better preserve chemical integrity since the air stream doesn't pars through the deposit, to collect samples as a function of time, and to have a wide variety of impaction surfaces available to match analytical needs. Although the transport of Yellow sand is a well-known phenomenon in springtime, the result of measurement shows that not only soil dust but also anthropogenic aerosols, including sulfur, enriched trace metals such as Pb, Ni, Zn. Cu, Cr, As, Se, Br, are transported to Gosan in springtime. This study combines the size- and time-resolved aerosol composition measurements with isentropic, backward air-mass trajectories in order to identify some potential source regions of anthropogenic aerosols. As a result, during the NYS period, the average concentration of PM$_{10}$ was 46$\mu\textrm{g}$/㎥, Si, Al. S, Fe, Cl, K, Ca were higher than 1,000 ng/㎥ and Ti was about 100 ng/㎥. The concentrations of Zn, Mn, Cu. Pb, Br, Rb, V, Cr, Ni. At, Se ranged between 1 and 70 ng/㎥. More than 50% typical soil elements, tuck as Al, Si, Fe, Cd. Ti, Cr, Cu, Br. were distributed in a coarse particle range(5.0-12${\mu}{\textrm}{m}$). In other hand, anthropogenic pollutants, luck as S, N, Vi, were mainly distributed in a fine particle range (0.09-0.56${\mu}{\textrm}{m}$). During the YS period, PM$_{10}$ increased about 8 times than NYS period, and main soil elements, such as Al, Si, S, K, V, Mn, Fe also doubled in coarse particle range (1.15-12${\mu}{\textrm}{m}$). But Zn, As, Pb, Cu and Se, which distributed in the time aerosols (0.09-0.56${\mu}{\textrm}{m}$), were on the same level with or decreased than NYS period. Finally. except the YS Period, coarse particles (2.5-12${\mu}{\textrm}{m}$) are inferred to be influenced by soil, coal combustion, waste incineration, ferrous and nonferrous sources through similar pathways with Yellow Sand. But fine particles have different sources, such as coal combustion, gasoline vehicle, biomass burning, oil or coal combustion, nonferrous and ferrous metal sources, which are transported from China, Korea peninsula and local sources.ces.

종류식 환기 시스템에서 임계속도 도달 전 스모크 확산 영역에 관한 실험적 연구 (An experimental study on the smoke-spread region before reaching the critical velocity for the case of fires in tunnels employing longitudinal ventilation system)

  • 김영민;윤성욱;윤찬훈;김진
    • 터널과지하공간
    • /
    • 제16권6호
    • /
    • pp.526-535
    • /
    • 2006
  • 본 연구에서는 장대터널 화재 시 발생하는 스모크의 거동특성을 파악하기 위해 축소모형실험을 실시하였다. Froude 상사를 기초로 실제 터널을 1/50로 축소한 20 m 의 아크릴 터널 모형을 제작하였으며, 파라핀 기체로 만든 스모크를 터널 내부에 주입시킴으로써 20MW의 실제 화재를 모사하였다. 실험에서 화재 발생 약 2분 후에 스모크는 부력효과의 감소로 아래로 하강하였으며, 제트팬 가동 전까지 4분 동안 스모크는 약 90 m를 이동하였다. 제트팬이 가동되고 기류속도가 임계속도 (도로터널 화재 중 발생하는 스모크의 역기류를 제압하기 위한 최소 공기속도)에 가까워질수록 스모크의 제어가 효율적으로 이루어지며, 스모크의 분포는 화원에서 약 3 m 정도로 더 이상 탈출 방향으로의 스모크 전파가 이루어지지 않았다. 하지만, 제트팬 가동 초기에 스모크의 제어가 거의 이루어지지 않음을 보였고 오히려 이 단계에서 탈출자의 호흡선 차단 등의 위험요소가 내재되어 있음을 알 수 있었다.

급랭광재(急冷鑛滓)의 비료화(肥料化)에 관(關)한 연구(硏究) -I. 급랭광재(急冷鑛滓)의 특성(特性) (Utilization of Blast Furnace Slag Quenched with Water as a Source of Silicate Fertilizer -I. Physico-chemical and Mineralogical Characteristics)

  • 신제성;임동규;김만수
    • 한국토양비료학회지
    • /
    • 제16권4호
    • /
    • pp.343-346
    • /
    • 1983
  • 제철광재(製鐵鑛滓)로 부생(副生)되는 급랭광재(急冷鑛滓)를 규산질비료(珪酸質肥料) 자원(資源)으로의 활용성(活用性)을 검토(檢討)해 보고저 포철(浦鐵)(주(株))의 급랭광재(急冷鑛滓)를 공시(供試)하여 이화학적(理化學的), 광물학적(鑛物學的) 특성(特性)을 조사(調査)한 결과(結果)는 다음과 같다. 급랭광재(急冷鑛滓)의 입자(粒子)는 주(主)로 모래알 크기로(1~2mm) 부생(副生)되며 서랭광재(徐冷鑛滓)로 제조(製造)한 현(現) 시판(市販) 규산질비료(珪酸質肥料)에 비(比)하여 조립질(粗粒質)이었으며 급랭(急冷)하므로서 광물조성(鑛物組成)이 무정질(無晶質)로 서랭광재(徐冷鑛滓)의 결정광물(結晶鑛物)과 대조적(對照的)이었다. 가용성규산(可溶性珪酸) 함량(含量)은 급랭광재(急冷鑛滓)에서 높았으며 반대(反對)로 서랭광재(徐冷鑛滓)에서는 결정성광물(結晶性鑛物)인 Akermanite, Cehlenite, Wollastonite을 다량(多量) 함유(含有)하고 있어 가용규산(可溶珪酸) 함량(含量)이 낮았다. 급랭광재(急冷鑛滓)의 수경성(水硬性) 및 입자(粒子)의 모서리가 예리(銳利)하기 때문에 직접시용(直接施用)할 경우 주의(注意)를 필요(必要)로 하나 규산질비료(珪酸質肥料) 자원(資源)으로서의 활용(活用)은 가능(可能)할 것으로 사료(思料)된다.

  • PDF

주상복합건물에서 단열 경계구역 축소에 따른 에너지 절감량 변화에 관한 연구 (A Study on the Energy-saving Variation by the Reduction of Insulation Boundary in Mixed-use Building)

  • 김대원;김영일;김성민;조진환;정광섭
    • 에너지공학
    • /
    • 제21권2호
    • /
    • pp.152-157
    • /
    • 2012
  • 지구온난화 및 에너지 고갈로 인해 건축물의 에너지효율 향상은 시대의 흐름으로 인식되고 있다. 건축물의 효율을 향상시켜 에너지를 절약하기 위해서는 결국 패시브 요소를 적용해야 한다. 그런 첫발걸음이 단열경계에 대한 새로운 기준 적용이라 생각한다. 현재 고시된 단열경계선 기준의 경우 경계가 적정하지 않을 뿐만 아니라, 용도별로도 구분되어있지 않다. 이로 인해 에너지가 낭비되고 있으며, 민원 또한 많이 발생되고 있는 실정이다. 이러한 문제점을 개선하기 위해 단열선 적용에 있어 난방과 비난방, 공조와 비공조 구간을 구분하고 건물을 용도별로 보다 더 세분화하는 기준이 필요하다. 본 연구에서는 새로운 용도별 단열경계와 적용 가능한 기준을 마련하여 정확한 실제 난방면적과 공조면적을 제시한다. 이렇게 제시된 실제 난방과 공조면적, 용도별 단열 경계기준선을 통해 장비의 적정한 용량과 부하의 일치를 기하고 최적의 유지관리로 에너지를 절감할 수 있는 기준을 마련함으로써 실 거주자의 환경개선뿐 아니라 에너지 절감효과까지 기대할 수 있는 가이드라인을 제시하고자 한다.