• Title/Summary/Keyword: Air space

Search Result 2,784, Processing Time 0.028 seconds

Comparative Study of Maximum Temperature Condition in Green Space (녹지 조건에 따른 최고기온의 비교연구)

  • 윤용한
    • Asian Journal of Turfgrass Science
    • /
    • v.15 no.4
    • /
    • pp.181-186
    • /
    • 2001
  • In this study, we observed air temperature to make clear that land coverage condition and forest form has a certain relationship to air temperature in a day in various green space. And with revolution analysis, interpreted relationship of air temperature distribution in the green space, of land coverage rate and air temperature, of volume of tree and temperature. With this experimental result, propose green plan, taking into consideration lower effect of air temperature. In this result lower zone is formed in forest and water area, higher zone is done in paved surface and barren ground. And arbor+subarbor area, water area sur-rounded forest and small river is formed relative lower air temperature. In my opinion to promote efficiency lower air temperature area, it is need to make water area surrounded forest, to make forest form lower air temperature 2∼3 layer forest. Lower air temperature effect is in order of arbor, subarbor, shrub and is proportioned increasing of tree.

  • PDF

TPH Removal of Oil-Contaminated Soil by Hot Air Sparging Process (고온 공기분사공정에 의한 유류오염대수층의 TPH 제거)

  • Lee, Jun-Ho;Park, Kap-Song
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.665-675
    • /
    • 2007
  • In-situ Air Sparging (IAS, AS) is a remediation technique in which organic contaminants are volatilized from saturated zone to unsaturated layer. This study focuses on the removal and interaction of Volatile Organic Compounds (VOCs) and $CO_2$, and Total Petroleum Hydrocarbon (TPH) in saturated and unsaturated, and air space zone on the unsaturated soil surface. Soil sparging temperature of hot air has risen to $34.9{\pm}2.7^{\circ}C$ from $23.0{\pm}1.9^{\circ}C$ for 36 days. At the diffusing point, fluid TPH concentrations were reduced to 78.7% of the initial concentration in saturated zone when hot air was sparged. The TPH concentrations were decreased to 66.1% for room temperature air sparging. The amount of VOCs for hot air sparging system, in air space, was approximately 26% larger than constant air sparging system. The amount of $CO_2$ was 4,555 mg (in unsaturated zone) and 4,419 mg (in air space) when hot air was sparged was 3,015 mg (in unsaturated zone) and 3,634 mg (in air space) for room air temperature in the $CO_2$ amount. The removals of VOCs and biodegradable $CO_2$ through the hot air sparging system (modified SVE) were more effective than the room temperature air sparging. The regression equation were $Y=976.4e^{-0.015{\cdot}X}$, $R^2=0.98$ (hot air sparging) and $Y=1055e^{-0.028{\cdot}X}$, $R^2=0.90$ (room temperaure air sparging). Estimated remediation time was approximately 500 days, if final saturated soil TPH concentration was set to 1.2 mg/L application of tail effect.

A Comparative Study of Air Law and Space Law in International Law (국제법상 항공법과 우주법의 비교연구)

  • Kim, Han-Taek
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.23 no.1
    • /
    • pp.83-109
    • /
    • 2008
  • According to 1944 Chicago Convention aircraft are classified into public aircraft(or state aircraft) and private aircraft(or civil aircraft). However even if public aircraft owned by government are used as commercial flights, those are classified into private aircraft. But as far as space activities are concerned in the 1967 Outer Space Treaty, those are related to all activities and all space objects, thus there being no differentiation between the public spacecraft and private spacecraft. As for the institutions of air law there are ICAO, IATA, ECAC, AFCAC, ACAC, LACAC in the world. However in the field of space law there is no International Civil Space Organization like ICAO. There is only COPUOS in the United Nations. The particular institutions such as INTELSAT, INMARSAT, ITU, WIPO, ESA, ARABSAT would be helpful to space law field. In the near future there is a need to establish International Civil Space Organization to cover problems rising from all space activities. According to article 1 of the 1944 Chicago Convention the contracting States recognize that every State has complete and exclusive sovereignty over the airspace above its territory. It means that absolute airspace sovereignty is recognized by not only the treaty law and but also customary law which regulates non-contracting States to the treaty. However as for the space law in the article n of the 1967 Space Treaty outer space, including the moon and other celestial bodies, is not subject to national appropriation by claim of sovereignty, by means of use or occupation, or by any other means. It creates res extra commercium like the legal status of high seas in the law of the sea. However the 1979 Moon Agreement proclaimed Common Heritage of Mankind as far as the legal status of the outer space is concerned which is like the legal status of deep sea-bed in the 1982 United Nations Law of the Sea. As far as the liabilities of air transport system are concerned there are two kinds. One is the liabilities to passenger on board aircraft and the other is the liabilities to the third person or thing on the ground by the aircraft. The former is regulated by the Warsaw System, the latter by the Rome Convention. As for the liabilities of space law the 1972 Liability Convention applies. The Rome Convention and 1972 Liability Convention stipulate absolute liability. In the field of space transportation there would be new liability system to regulate the space passengers on board spacecraft like Warsaw System in the air transportation.

  • PDF

A Study on Characteristics of Indoor- Air-Quality in Interior Space Equipped with System Air-Conditioner (시스템 에어컨 설치 공간의 실내공기질 특성에 관한 연구)

  • Lee, Sang-Won;Kim, Jong-Min;Yeum, Seung-Won;Cho, Dae-Gun;Choi, Jae-Boong;Kim, Seok-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.304-313
    • /
    • 2008
  • This paper investigates the indoor-air-quality (IAQ) characteristics of the interior space equipped with system air-conditioner. The behaviors of individual variables such as temperature, humidity and concentration of carbon dioxide ($CO_2$) that influence on IAQ of the interior space were characterized under various cooling conditions by numerical and experimental studies. The numerical analysis predicting the temperature behavior of the interior space was conducted, and its results showed a good agreement with the experimental ones. The $CO_2$ concentration and humidity were measured and their time dependent behaviors were monitored and analyzed. From the results, it was found that there existed the differences of the time-dependent behaviors of IAQ variables according to the locations. In addition, it is demonstrated that the large discharge angle of $45^{\circ}$ made the temperature profile more irregular and the high discharge flow of 5.34 m/s produced similar temperature profiles at three different sensing locations. Finally, the humidity of interior space was less sensitive to the changes of the air cooling conditions than the case of temperature and the $CO_2$ concentration increase mainly depended on the number of individuals inside the space.

A Study on the Environment Planning of Exhibition Space for Conservation of Collection in a Museum (박물관자료의 보존을 위한 전시공간 환경계획에 관한 연구)

  • Jung, Sung-Wook
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.2
    • /
    • pp.91-101
    • /
    • 2008
  • The purpose of this study is to suggest the design guidelines of exhibition space for conservation of collection in a museum. With the purpose of this study, examined the concept and a condition of conservation which is focused on deterioration in a exhibition space, investigated the actual condition of total 42 facilities and analyzed the specific instance which is excellent by factor of environment plan. Hereupon, the results of this study are as follows. First, exhibition space should be equipped with sufficient 'Filtering Space' before the outdoor and located central territory in a museum facility. Second, exhibition space should be partition off an area into the quality of collection, and then controlled by each of them. Third, in consideration of the annual air fluctuation of our country, the database which is adaptable for setting up the standard of temperature and RH must be prepared. Fourth, it is necessary to establish a 'Reference Exhibition Room' which is formed cellular type and a 'Garnering Exhibition Center'. Fifth, for the prevention of deterioration which is generated in exhibition space, the showcase must be high air-tight. Sixth, it is necessary to reduce a inside space of high air-tight showcase. Seventh, art-sorb is suitable for control the organic matter of collection and a except of fiber optics is not suitable for lighting of showcase. Eighth, wall-type showcase should be have air-chamber which is formed like museum storage and run over 8 hours a day.