증발기의 압력강하에 대한 상대습도의 영향 (Effects of Relative Humidity on the Evaporator Pressure Drop)

  • 김창덕;강신형;박일환;이진호
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.397-407
    • /
    • 2004
  • It is well known that some key parameters, such as evaporating temperature, refrigerant mass flow rate, face velocity and inlet air temperature, have significant influence on the evaporator performance. However performance studies related to a humid environment have been very scarce. It is demonstrated that the refrigerant mass flow rate, heat flux, water condensing rate and air outlet temperature of the evaporator significantly increase with air inlet relative humidity. As the air inlet relative humidity increases, the latent and total heat transfer rates increase, but the sensible heat transfer rate decreases. The purpose of this study is to provide experimental data on the effect of air inlet relative humidity on the air and refrigerant side pressure drop characteristics for a slit fin-tube heat exchanger. Experiments were carried out under the conditions of inlet refrigerant saturation temperature of 7 $^{\circ}C$ and mass flux varied from 150 to 250 kg/$m^2$s. The condition of air was dry bulb temperature of 27$^{\circ}C$, air Velocity Varied from 0.38 to 1.6 m/s. Experiments Showed that air Velocity decreased 8.7% on 50% of relative humidity 40% of that at degree of superheat of 5$^{\circ}C$, which resulted that pressure drop of air and refrigerant was decreased 20.8 and 8.3% for 50% of relative humidity as compared to 40%, respectively.

외기 온도 변화가 핀-관 열교환기의 공기측 열전달계수와 마찰계수에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of the Air Temperature on the Air-Side Heat-Transfer Coefficient and the Friction Factor of a Fin-and-Tube Heat Exchanger)

  • 김내현;조홍기
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.149-158
    • /
    • 2017
  • In general, the air-side j and f factors of evaporators or condensers are obtained through single-design tests performed under air-dry and wet-bulb temperatures. Considering that the indoor or outdoor air temperatures vary significantly during the operation of an air conditioner, it is necessary to confirm that the experimentally-obtained j and f factors are widely applicable under variable air conditions. In this study, a series of tests were conducted on a two-row slit-finned heat exchanger to confirm the applicability. The results showed that, for the dry-surface condition, the changes of the tube-side water temperature, water-flow rate, and air temperature had virtually no effect on the air-side j and f factors. For the wet condition, however, the f factor was significantly affected by these changes; contrarily, the j factor is relatively independent regarding this change. The formulation of the possible reasoning is in consideration of the condensation behavior underneath the tube. The wet-surface j and f factors are larger than those of the dry surface, with a larger amount for the f factor.

2열 핀-관 열 교환기의 열별 전열성능 측정 (Heat Transfer Performance of Individual Rows in Fin-Tube Heat Exchangers)

  • 권영철;정지환;장근선;홍기수;진심원
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.280-286
    • /
    • 2004
  • An experimental study is peformed to examine the heat transfer performance of individual rows of fin-tube heat exchangers. The heat transfer performance is measured using an air-enthalpy type calorimeter. The examined heat exchangers consist of 7mm tube and fin patterns of them are slit and louver types. Equivalent fin spacings are 18 fins per inch(fpi) for all samples, and the number of tube rows are two. In order to confirm that thermal boundary condition on fins of each row are the same, physically separated between two rows as well as connected heat exchangers are used. The frontal air velocity is varied from 0.7 to 2.5㎧. Heat transfer performance for each row is measured. It is observed that the heat transfer coefficient of the second row is smaller than that of the first row at low Reynolds number while larger at high Reynolds number.

별늑대거미 (Pardosa astrigera L. Koch) 서폐의 미세구조 (Fine Structure of Book Lung in the Wolf Spider, Pardosa astrigera)

  • 임형수;문명진
    • Applied Microscopy
    • /
    • 제24권2호
    • /
    • pp.1-11
    • /
    • 1994
  • The book lung in the wolf spider, Pardosa astrigera was consisted of a series of flattened triangular-shaped air sacs, stacked with about 70 sheets, and was located in the ventrolateral region of opisthosoma. Each hemolymph spaces (average $8{\mu}m$ in thickness) surrounded by the air sacs (average $6{\mu}m$ in thickness). The air sacs was supported by cylindrical cuticular spikes of microfibril bundles. Epithelial cell processes surrounded the hemolymph spaces. The nuclei of the epithelial cells were concentrated near the atrium. In the middle portion of air sac, the epithelial cells formed pillars across the hemolymph spaces and spot desmosome and zonula adherens were seen between the plasma membranes. In the hemolymph space of this spider, granular hemocytes (average diameter $8{\mu}m$) were the most dominant type of hemocytes. In the medial sinus, the hemolymph flow between the air sacs of a paired book lungs and then flow out of the lung vein. The air comes in the atrium through the ventral lung slit and makes a tidal wave in and out of the air sacs.

  • PDF

Correlation between Velocity Fluctuation and Fluctuation of Hydrogen Concentration in 2-D Air-Hydrogen Supersonic Mixing Layer

  • Sakima, Fuminori;Arai, Takakage;Edward, Shelley-R.;Mori, Yuko
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.111-116
    • /
    • 2004
  • An experiment was carried out to confirm the validity of time series evaluation of supersonic mixing condition by using catalytic reaction on a platinum wire. Geseous hydrogen was injected parallel to supersonic freestream (M$\infty$ $\approx$ 1.81) from a slit injector, which was located at backward facing step. Time series condition of supersonic mixing was evaluated by using W-type probe which has a platinum wire and reference wire (nickel wire). The evaluation was by simultaneously measuring each electric circuit which kept the temperature of wire constant. Investigations were also conducted for helium, air and no secondary injectant cases to compare with the hydrogen injectant case. The results indicated that it was possible to measure the time series behavior of air and hydrogen supersonic mixing layer or coherent motion of turbulence by using this evaluation.

  • PDF

설계조건에 따른 핀-튜브 증발기의 열전달 특성 (Heat Transfer Characteristics on Design Conditions of Finned-Tube Evaporators)

  • 강희정;이윤수;권영철;장근선;김영재
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.46-54
    • /
    • 2002
  • To investigate the design effects of a heat exchanger on a tube type, a tube circuit and a fin pitch, an experimental study on the heat transfer characteristics of finned- tube evaporators was performed. The refrigerant was R-22. A refrigerant loop was established to measure the heat transfer rate, the air heat transfer coefficient. The experimental results showed that the heat transfer characteristics of the evaporators were affected by the design parameters. And the heat transfer rate of the slit fin was better about 25%, compared to those of the louver fin. In the present experimental range, the heat transfer performance with the straight tube circuit was more remarkable than that of the zigzag tube circuit, as seen from temperature variations of the evaporator exit. $\jmath$-factor on the tube type, the tube circuit and the fin pinch decreased, as increasing Reynolds number.

핀-관 열교환기의 난방운전 시 공기측 열전달 및 마찰특성 (Air-side Heat Transfer and Friction Characteristics of Fined-tube Heat Exchangers under Heating Condition)

  • 권영철;장근선;고국원;김영재;박병권
    • 공업화학
    • /
    • 제17권5호
    • /
    • pp.476-482
    • /
    • 2006
  • 본 연구에서는 핀-관 열교환기의 공기측 열전달 및 마찰특성을 조사하기 위하여 8종의 열교환기에 대하여 난방조건에서 실험을 수행하였다. 핀-관 열교환기의 성능 비교평가를 위하여 공기엔탈피식 칼로리미터를 이용하였다. 실험에 사용된 핀은 슬릿, 루버, 평판형이며, 관경은 7.0 mm, 열수는 1, 2, 3열 그리고 4종의 관회로에 대해 j 계수와 마찰계수를 획득하였다. 실험을 통해서 핀형상, 핀피치, 열수 그리고 관회로의 변화에 대한 핀-관 열교환기의 공기측 열전달 및 마찰거동을 조사하였다. 실험결과는 관회로의 구성이 열교환기의 열전달과 마찰과 관련이 있음을 보여주었다. 동일 핀피치의 열교환기의 경우에 저 Re 수에서는 1열의 열전달성능이 우수하나 Re 수가 증가할수록 j 계수의 거동은 역전함을 보였다. 그리고 2열의 열교환기에서 핀종류에 따라 공기측 열전달성능과 마찰계수가 다르게 나타남을 확인하였다.

재순환역을 수반하는 동축분류예혼합화염에 관한 연구 (Stability of premixed double concentric jets flame with a recirculation zone)

  • 이등헌일;송규근
    • 대한기계학회논문집
    • /
    • 제11권1호
    • /
    • pp.145-153
    • /
    • 1987
  • 본 논문에서는 예혼합동축분류화염에 있어서 재순환역 안으로의 기체(공기, 연료, 혼합기) 주입과 2차공기의 족회가 화염안정성, 화염형상 및 재순환역에 미치는 영향을 명확히 하였다.

Effects on Refrigerant Maldistribution on the Performance of Evaporator

  • Lee, Jin-Ho;Kim, Chang-Duk;Byun, Ju-Suk;Jang, Tae-Sa
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권2호
    • /
    • pp.107-118
    • /
    • 2005
  • An experimental investigation was made to study two-phase flow distribution in a T-type distributor of slit fin-and-tube heat exchanger using R-22. Experiments were carried out under the conditions of saturation temperature of $5^{\circ}C$ and mass flow rate varying from 0.6 to 1.2kg/min. The inlet air has dry bulb temperature of $27^{\circ}C$, relative humidity of 50% and air velocity varying from 0.63 to 1.71m/s. A comparison was made between the predictions from the previously proposed tube-by-tube method and the present experimental data for the heat transfer rate of evaporator. Results show that $82.5\%$ increase of air velocity is needed for T-type distributor with four outlet branches than that of two outlet branches under the superheat of $5^{\circ}C$, which resulted in increasing of air-side pressure drop of $130\%$ for the former as compared to the latter.