• 제목/요약/키워드: Air slit

검색결과 89건 처리시간 0.018초

Condensation Heat Transfer of R22, R407C, and R410A in Slit Fin-and-Tube Heat Exchanger

  • Jeon, Chang-Duk;Lee, Jin-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권4호
    • /
    • pp.188-198
    • /
    • 2003
  • R410A and R407C are considered to be alternative refrigerants of R22 for the air-conditioners. An experimental study is carried out to investigate the effect of the change of mass flow rate on the characteristics of heat transfer and pressure drop in three row slit finned-tube heat exchanger for R407C, R410A and R22. R407C, a non-azeotropic refrigerant mixture, exhibited a quite different condensation phenomenon from those of R22 and R410A and its condensation heat transfer coefficient was much lower than that of R22 and R410A. On the other hand, the condensation heat transfer coefficient of R410A, near-azeotropic refrigerant mixture, was a little higher than that of R22. R410A also showed the lowest condensation pressure drop across the test section. For all refrigerants, the condensation heat transfer coefficient and pressure drop increase as the mass flux increases. The condensation heat transfer coefficient correlation proposed by Kedzierski shows the best agreement with the experimental data within $\pm$20%.

Air-twist 노즐 형상 설계의수치적 연구 (A COMPUTATIONAL APPROACH TO DESIGN THE GEOMETRY OF THE AIR-TWIST NOZZLE)

  • 쥬래바 막슈다;송동주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.67-70
    • /
    • 2010
  • Spandex yarn requires a twisting process during winding and unwinding processes at the textile industry. The air-twist nozzle is widely used as part of the winding and unwinding. This paper describes computational approach to design the geometry of the air-twist nozzle. The nozzle has circular yarn-channel and the air-inlet which is perpendicularly connected to the yarn-channel with yarn-loading slit. The air-inlet of the nozzle is designed while measurements of the yarn-channel are fixed. The airflow inside the air-twist nozzle is simulated by using Computational Fluid Dynamic model. The Ansys CFX was used to perform steady simulations of the airflow for the air-twisting process. The vortical structure and the airflow pattern such as velocity streamline, vorticity, velocity of the air-twist nozzle are discussed. Computational results are compared with experimental results in this paper.

  • PDF

AIR-MULTIPLIER 단면 형상에 따른 유동양상에 대한 수치적 해석 (Numerical analysis of air flow in the various shapes of air multiplier cross section)

  • 최정식;김형묵;김유민;구본찬
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제3회(2014년)
    • /
    • pp.610-613
    • /
    • 2014
  • 본 연구에서는 Dyson사의 Air multiplier의 Coanda surface각도에 따른 Air foil 주변의 2차원 유동을 분석하고 Surface각도가 유동에 미치는 영향에 대해 해석하였다. Air multiplier 단면의 작은 Slit을 통해 분류된 공기는 Venturi effect에 의해 가속되며 Coanda effect에 의해 단면을 따라 흐르며 압력차를 발생시켜 주변의 공기를 추가적으로 유입시킨다. EDISON CFD를 이용하여 Surface 각도에 따른 Air foil 주변의 유동을 구현하고 각도가 유동에 미치는 영향을 해석하였다. 또한 다른 논문에서 발췌한 실험값과 CFD 분석을 통해 얻은 값을 비교하여 CFD분석이 유효한지 확인하였다.

  • PDF

초음속 공기유동으로의 연료 분사노즐 종횡비 변화에 대한 연소특성 연구 (Effects of Aspect Ratio of a Fuel Injection Nozzle into a Supersonic Air Stream on Combustion Characteristics)

  • 김경무;백승욱;김윤곤
    • 한국추진공학회지
    • /
    • 제8권1호
    • /
    • pp.44-53
    • /
    • 2004
  • 본 논문에서는 슬릿형 분사노즐의 출구 종횡비에 따라 3차원 화학반응 유동장을 수치적 계산을 통하여 그 특성을 조사하고 연소/혼합 촉진 방법을 고찰하였다. 내부유입유동과 슬릿측면 와동들 둘 다 혼합관점에서 고려되어야 한다는 것을 보여 주었다. 연소효율은 종횡비1.0을 기준으로 작은 경우가 낮고 압력손실 역시 종횡비가 작은 경우가 적다. 모든 결과들은 유동방향으로 긴 슬릿이 연소와 압력손실에 대해 바람직함을 나타내고 있다.

공구파손감지용 비젼시스템의 NC실장에 관한 연구 (A Study on the NC Embedding of Vision System for Tool Breakage Detection)

  • 이돈진;김선호;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.369-372
    • /
    • 2002
  • In this research, a vision system for detecting tool breakage which is hardly detected by such indirect in-process measurement method as acoustic emission, cutting torque and motor current was developed and embedded into a PC-NC system. The vision system consists of CMOS image sensors, a slit beam laser generator and an image grabber board. Slit beam laser was emitted on the tool surface to separate the tool geometry well from the various obstacles surrounding the tool. An image of tool is captured through two steps of signal processing, that is, median filtering and thresholding and then the tool is estimated normal or broken by use of change of the centroid of the captured image. An air curtain made by the jetting high-pressure air in front of the lens was devised to prevent the vision system from being contaminated by scattered coolant, cutting chips in cutting process. To embed the vision system to a Siemens PC-NC controller 840D NC, an HMI(Human Machine Interface) program was developed under the Windows 95 operating system of MMC103. The developed HMI is placed in a sub window of the main window of 840D and this program can be activated or deactivated either by a soft key on the operating panel or M codes in the NC part program. As the tool breakage is detected, the HMI program emit a command for automatic tool change or send alarm to the NC kernel. Evaluation test in a high speed tapping center showed the developed system was successful in detection of the small-radius tool breakage.

  • PDF

슬릿휜형 열교환기의 성능에 대한 설계인자의 영향 (Effect of design factors on the performance of heat exchanger with a slit fin)

  • 윤점열;이관수;김현영;강희찬
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.210-220
    • /
    • 1997
  • This study is to systematically analyze the effect of various kinds of design parameters on heat transfer and pressure drop characteristics of heat exchanger with a slit fin. TAGUCHI method, known to us as a very reasonable tool in the parametric study, is employed in the present work. Experimental factors have been limited to seven cases, considering the production of sample and the cost. The 18 kinds of large scale models are made by compounding level on each factor and the heat transfer and flow characteristics on each model has been analyzed. The present results allow us to be able to quantitatively estimate the various parameters affecting the heat exchanger performance, and main factors for an optimum design of a heat exchanger have been selected. The optimum design value on each parameter was presented and the reproducibility on the results was guaranteed.

  • PDF

냉매의 불균일한 분배가 증발기의 성능에 미치는 영향 (Effects on Refrigerant Maldistribution on the Performance of Evaporator)

  • 김창덕;이진호
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.230-240
    • /
    • 2004
  • An experimental investigation was conducted to study two-phase flow distribution in a T-type distributor of slit fin-and-tube heat exchanger using R22. A comparison was made between the predictions by previously proposed tube-by-tube method and experimental data for the heat transfer rate of evaporator. Experiments were carried out under the conditions of saturation temperature of 5$^{\circ}C$ and mass flow rate varying from 0.6 to 1.2kg/min. The inlet air has dry bulb temperature of 27$^{\circ}C$, relative humidity of 50% and air velocity varying from 0.63 to 1.71㎧. Experiment show that air velocity increased by 85.2% is need for T-type distributor with four outlet branches than that of two outlet branches under the superheat of 5$^{\circ}C$, which resulted in air-side pressure drop increase of 130% for T-type distributor with four outlet branches as compared to two outlet branches.

메탄/공기 다중 제트 예혼합 화염에서의 유동과 연소특성 (Flow and Combustion Characteristic in an Array of Multiple Pre-Mixed Methane/Air Flame Jets)

  • 김영수;이대래;하만영;장영준;전충환;조승완;강길영;유재현
    • 대한기계학회논문집B
    • /
    • 제31권6호
    • /
    • pp.547-557
    • /
    • 2007
  • This study was conducted to investigate the flow and combustion characteristic of the experimental burner which was manufactured for the reflection of the oven and broil burner features. As slot shape, spacing between slots, and slot arrangement of the exit area which emits the mixing gas are different in case of oven burners and broil turners, the purpose of this study is to know the affection of the flame interaction and combustion characteristic according to the change of shape factors such as slot shape, slot arrangement, and slot-to-slot spacing. With no relation of the slot shape, as the spacing between slots became narrow, the occurrence of a lift-flame was delayed. So the combustion was possible in the leaner region, but the appearance of yellow-tip became a little fast. Slit slot port had the broadest operating range among the other slot shapes. Specially, from the side of lift-flame, as the jet that spreads downstream in the longitudinal slot was nearly circular just a few slot lengths away from the orifice, slot-to-slot spacing of the Slit port was closer than the other ports. These results could be expected through the computer numerical method and had a good agreement. As the spacing between slots increased, in case of Slit and Mix port, NOx emission rate was constant or decreased, but the NOx emission of Hole port was increased. CO emission rate of Slit and Hole port was increased as the slot-to-slot spacing was broadened.

응축압력 변화에 따른 R407C의 응축특성에 관한 연구 (An Experimental Study on Condensation Characteristics at Various Condensation Pressure of R407C)

  • 전창덕;장경근;김창덕;이진호
    • 설비공학논문집
    • /
    • 제15권3호
    • /
    • pp.230-238
    • /
    • 2003
  • R407C is considered as alternative refrigerant of R22 for air conditioners. Experimental investigation is made to study the condensation heat transfer characteristics of slit fin-tube heat exchanger using alternative refrigerant, R407C. Experiments are carried out at condensation pressure of 2110 kPa and 1943 kPa with the degree of superheat of 1$0^{\circ}C$ and mass flux varying from 150 to 250 kg/$m^2$s for refrigerant side. The inlet air condition is dry bulb temperature of 35$^{\circ}C$, relative humidity of 50% and air velocity varying from 0.8 to 1.6 m/s. Experiments show that pressure drop gets smaller at a higher condensation pressure especially when condensation pressure is raised from 1943 to 2110 kPa. Heat transfer rate gets smaller at a lower condensation pressure in the range of experimental condition.