• Title/Summary/Keyword: Air sampler

Search Result 385, Processing Time 0.034 seconds

Characteristics of Concentration and Size Distribution of PAHs of Total Suspended Particulates in urban air (도시대기부유분진중 다환방향족 탄화수소의 농도 및 입경분포 특성)

  • 조기철;이승일;김달호;허귀석;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.57-63
    • /
    • 1994
  • In order to comprehension of the behaviour of PAHs in air which is known as carcinogens and/or mutagens suspended Particulates in ambient air were collected by Anderson air sampler from 1992. 6 to 1993. 5 in Seoul. Ten species of PAHs( Phen, An, Fl, R, Py, BaAn, BaP, Chry, BeP, DiB(a, h)An, I123p) were analyzed to understand monthly variations of PAHs distribution of PAHs concentration according to particle size, and correlation between PAHs and independent charactierstics of PAHs The highest concentration of TSP was 155.58$\mu\textrm{g}$/㎥ in May and the lowest was 60$\mu\textrm{g}$/㎥ in August. Concentration of TSP was more affected by coarse particles in spring, otherwise which was more affected by fine particles in winter. According to results of anaylsis of samples that were collected by Anderson air sampler, concentration of PAHs was more high in winter than that in summer. In almost samples collected by Anderson air sampler, concentration of PAHs was more high in coarse particles than in fine particles, but BaP well known as carcinogenic matter had more high concentration in fine particles(56-97.5%) than that in coarse particles(2.5-46%). Correlation between concentrations of TSP and PAHs was more high in fine Particles than in coarse Particles. Both fine particles and coarse particles have negative correaltion with radiation.

  • PDF

A Study on Physico-chemical Properties of Dust-fall in Inchon (대기중 강하먼지의 물리화학적 특성분석 -인천지역을 중심으로-)

  • 성일화;민달기;김종규
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.2
    • /
    • pp.83-89
    • /
    • 1996
  • In order to evaluate the air quality, dry and wet deposition samples were collected by deposit containers during four months in Inchon area. The samples were analyzed for its solid composition and trace elements(Ca, Cd, Cu, Fe, Mn, Ni, Pb, Zn). The main results are summarized below 1. The amounts of dry and wet deposition in Inchon area were 1.06~3.14 ton/$km^2$/month, and affected by the rainfall and suspended yellow sand. 2. Through the analysis of solid balance, we found that 50% of total solids(TS) was fixed suspend ed solids(FSS), 25% was fixed dissolved solids(FDS), and each of volatile suspended solids(VSS) and volatile dissolved solids(VDS) accounted for 12.5%. 3. The amounts collected by sampler for trace elements were 938 ~ 2,765 $\mu g$ calcium/10days sampler, 0.2 ~ 90.4 $\mu g$ cadmium/10days/sampler, 26 ~ 298 $\mu g$ copper/10days/sampler, 928 ~ 3,939 $\mu g$ iron/10days/sampler, 50 ~ 202 $\mu g$ manganese/10days/sampler, 4 ~ 37 $\mu g$ nickel/10days/sampler, 52 ~ 406 $\mu g$ lead/10days/sampler, and 97 ~ 1,317 $\mu g$ zinc/10days/sampler, respectively. 4. Using the manganese analysis, it was found that 76.1% of TS was from soil.

  • PDF

Development of a Passive Sampler using a Fluorescence Material for the Ambient Ozone (형광물질을 이용한 대기 중 오존 Passive Sampler의 개발)

  • 임봉빈;정의석;김선태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.4
    • /
    • pp.483-491
    • /
    • 2004
  • The purpose of this study is to develop an ozone passive sampler and to evaluate its performance p-Acetamidophenol using as the reagent for ozone reacts specifically with the ambient ozone to produce a fluorescence material (p-acetamidopheonl dimer). The volume of absorbent solution and the extraction time determined at suitable conditions for measuring ozone were 100$\mu$L and 60 min, respectively. The changes of fluorescence were observed with incresing the storage period of passive samplers in ambient air. but the cool storage in a refrigerator did not remarkably influence the increase of fluorescence. The measurement for the precision oi the passive sampling was carried out with duplicate measurement of passive samplers. The intra-class correlation coefficients of passive samplers using dry and wet filters were 0.992 and 0.962, respectively The results from field validation tests indicated practical agreement (dry filter: r=0.963, wet filter: r=0.995) between the passive sampler and an UV photometric $O_3$ analyzer. The limit of quantification of ozone passive samplers with sampling time of 8 hr (wet filter) and 24 hr (dry filter) were 8.0 ppb and 2.7 ppb, respectively.

A Comparison of Nicotine Diffusive Sampler and XAD-4 Tube for Determination of Nicotine in ETS

  • Kim, Hyo-Cherl;Paik, Nam-Won;Kim, Kyoung-Ran;Kim, Kyoung-Su;Lee, Kyoung-Suk;Cho, Kyung-Ah
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.371-372
    • /
    • 2005
  • Active sampler has been widely used to measure nicotine concentration in air. The experiments were conducted to compare the active sampler method with diffusive sampler in exposure chamber and smoking areas, respectively. The result of these tests that indicated that passive sampler can be used instead of active sampler in ETS, because coefficient of determination was 0.9292 between active and passive sampling in smoking area

  • PDF

A Simple and Simultaneous Analysis of Volatile Halogenated Hydrocarbons in Indoor Air Using Personal Sampler

  • Jung, Won-Tae;Sohn, Dong-Hun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.E
    • /
    • pp.373-381
    • /
    • 1993
  • To understand the human exposure levels of volatile halogenated hydrocar-bons in ambient air, a new rapid and convenient analytical method for determination of the compounds in gaseous phase was evaluated and established. The method is based upon passsive diffusion to personal sampler containing adsorbent and solvent extraction followed by purge trap/ on-column cryof-ocusing method. A new method needs no special instrumentation for gas collection because it is based upon the passive diffusion principle. The typical chromatogram obtained in this study proved that rapid and simultaneous determination of target analytes was possible with good resolution. The developed method was successfully applied to determine the volatile halogenated hydrocarbons in indoor air and the values obtained by this new method were compared with those by direct suction method. The concentration of carbon tetrachloride, 1,1,2-trichloroethylene, chloroform showed the values below 400$\mug/m^3$ except the maximum of 1,513$\mug/m^3$ of chloroform. 1,1,1-Trichloroethane showed approximately 1,000 to 5,000$\mug/m^3$ range of diurnal fluctuation in indoor air.

  • PDF

A Study on the Air Pollution Component in Hwasoon Nulitjae Tunnel (화순너릿재 터널내의 대기오염성분에 관한 조사연구)

  • 신대윤;송금섭;김정규;송연호;임만택
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.3
    • /
    • pp.52-57
    • /
    • 1993
  • This study was carried out to investigate the air pollution in Hwasoon Nulitjae tunnel for two months, from August 1992 to September 1992. The total suspended particles were collected by high volume air sampler at inside and outside of Hwasoon Nulitjae tunnel, of which major water soluble component and heavy metalic element were analyzed. Size distribution and respirable mass fraction of aerosol at inside were measured by filters on nine stages Andersen air sampler. The average concentration of TSP at inside was 657.57 $\mu$g/m$^3$, which appeared about 9.2 times as high as that of 71.47 $\mu$g/m$^3$ at outside. The decrease effect caused by using new tunnel was 31.2%. As a result of correlation analysis between concentration of TSP at inside of Hwasoon Nulitjae tunnel and that at outside, correlation coefficient was 0.713. The average concentrations of SO$_4^{2-}$ , NO$_3^-$, CI$^-$ were 43.02 $\mu$g/m$^3$, 19.86 $\mu$g/m$^3$, 4.96 $\mu$g/m$^3$, those of NH$_4^+$, Na$^+$, K$^+$ 1.42 $\mu$g/m$^3$, 4.45 $\mu$g/m$^3$, 2.89 $\mu$g/m$^3$ and those of Ca$^{2+}$, Mg$^{2+}$, Pb$^{2+}$ 3.92 $\mu$g/m$^3$, 2.27 $\mu$g/m$^3$. 1.52 $\mu$g/m$^3$, respectively. It was estimated that mass fraction rate of respirable particle at inside was about 84.54% of aerosol. The average concentration of suspended particle to be collected by Andersen sampler was 478.90 $\mu$g/m$^3$, this was about 72.8% of that by high volume air sampler.

  • PDF

A study on a spatial distribution of urban scale using passive sampler (Passive sampler를 활용한 도시규모의 이산화질소 공간분포 조사)

  • 이범진;김선태;이종현
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.109-110
    • /
    • 2002
  • 환경대기 중의 오염물질의 농도를 표시하고 계산하는 방법은 물질의 종류에 따라 다른 방법을 사용하지만 동일한 연구대상공간에서의 측정결과는 측정목적에 부합하는 방법으로 측정한 결과에 따라 유의미한 정보를 창출하게 된다. 본 연구에 사용된 Passive sampler법은 전원 및 기타장비, 기술 등이 필요치 않아 시ㆍ공간적 제약이 적어 광범위한 지역에 대한 동시 측정의 목적으로 활용될 수 있다.(UNEP/WHO, 1994). (중략)

  • PDF

Application of Passive Sampler in Validation and Calibration of Air Dispersion Model (대기확산모델의 검정 및 보정을 위한 Passive Sampler의 활용)

  • 김선태;김주인;김성근;배장영
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.170-171
    • /
    • 1999
  • 대기 중 오염물질의 확산 및 미래의 예측을 위하여 대기확산모형을 많이 사용하고 있으며, 국내에서 사용하고 있는 대기확산모형의 대부분은 미국 EPA에서 보급하는 것을 사용하고 있다. 이 중에서 최근에 많이 사용하고 있는 단기모형으로는 기간과 지형이 고려되는 ISCST3 모형을 들 수 있다. 국내 모델의 사용에 있어서 가장 중요한 문제점은 모델의 검정과 보정을 위한 data의 부재를 들 수 있다.(중략)

  • PDF

Blood Toluene Concentration of Shoes Factory's Workers Exposed to Toluene (신발제조업 근로자의 톨루엔 노출정도에 따른 혈중 톨루엔 농도분석)

  • 양정선;강성규;정호근
    • YAKHAK HOEJI
    • /
    • v.37 no.5
    • /
    • pp.458-462
    • /
    • 1993
  • Blood toluene concentrations of thirty nine Korean toluene-exposed workers in shoes making factory were checked by headspace-gas chromatographic analysis. Air toluene concentrations in each worker's working region also checked by personal sampler during workshift and analyzed by gas chromatography. The range of blood toluene concentration was 0.15-0.84mg/L. The range of toluene concentration of each worker's working area was 8.46-189.9ppm. The correlation between blood and air concentration of toluene was 0.824.

  • PDF

The Development of New Diffusive Sampler for Formaldehye in Air (기중 포름알데히드 측정을 위한 확산포집기의 개발)

  • Choe, Mee-heon;Lee, Kwang-Mook;Roh, Young-Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.173-186
    • /
    • 1999
  • To utilize diffuse sampling of formaldehyde in air, a new sampler was designed. A glass fiber filter was impegnated with 2,4-dinitrophenylhydrazine(DNP) and phosphoric acid and mounted 37mm cassette. The formaldehyde vapor was sampled in the dynamic chamber and measured by high performance liquid chromatograph and compared with solid sorbent tube. The results were as follows ; 1. The desorption efficiencies of diffusive sampler between 97.0% and 100%. 2. the sampling rate is constant as in $58{\sim}61.8m{\ell}/min$ when sampling times are between 120 and 360 min. 3. There was a significant relationship between concentrations of diffusive samples and active samples with the coefficient of determination(R2) of 0.92. 4. Desorbed amount of formaldehyde diffusive sampler was increased by high relative humidity. 5. Wheth diffusive samplers were stored at room temperature or at refrigerator there was no statistically significant difference in the accuracy of result. 6. When the diffusive samplers, which collected formaldehyde vapor, were exposed to clean air for three hours, there was no significant loss of formaldehyde due to reverse diffusion. In conclusion, this study suggest that developed diffusive samplers will be a reasonable substitute for the solid sorbent tube for sampling formaldehyde and practical comparative study of developed diffusive sampler should be performed at workplaces of manufacturing industry.

  • PDF