• Title/Summary/Keyword: Air rush-in

Search Result 42, Processing Time 0.029 seconds

Design of Controller for Reducing In-Rush Current of Single-Phase Induction Motor (단상유도전동기의 돌입전류저감을 위한 제어기 설계)

  • Park, Su-Kang;Baek, Hyung-Lae;Lee, Sang-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.5
    • /
    • pp.238-245
    • /
    • 2001
  • During an AC motor's start-up accelerating period, a large amount of current is required to reach to the rating speed. This is called in-rush current. This peak in-rush current can be more than about several times the operating or steady-state current in the full load rating of the motor. In-rush current is present in both and electronic ballasts. The main area of concern is the tripping of circuit breaker and fuses which can affect electrical system components From this, we can see that the electrical power controllers will be rather concerned, since they have to supply the actual current necessary to start the motor. This paper presents a new method to reducing in-rush current and energy saving of the single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

A Study on the Temperature Variation Characteristics of Electric Car Depending on Passenger Number (승객 수에 따른 전동차 객실공간의 온도변화 특성 연구)

  • Hahm, Dae-Ju;Park, Duck-Shin;Nam, Seong-Won;Maeng, Hee-Young
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.393-399
    • /
    • 2008
  • A Study has been conducted on the characteristics of temperature variation depending on passenger number that is measured in Bundang Line(From Sunleng To Bojong). As a basic study, the air quality of passenger room for the electric rail car is evaluated. Although ISO7730 recommends that the height of measuring points for the heat environment is to set at 0.1m, 0.6m, 1.1m and 1.7m respectively, temperature are measured at two points at 1.1m and 1.7m because of the difficulty to measure temperature of 0.1m height in rush hour. We compared the results of temperature variations between two stations in rush hour(07:56-08:41). In general, the capacity of a passenger car is designed for 160 persons, but over 280 persons often board on electric rail in rush hour. The temperature of room is adjusted from $22^{\circ}C$ to $24^{\circ}C$, but it is measured from $26^{\circ}C$ to $28^{\circ}C$ on average. Therefore, it shows that there are difference between the set temperature and measured one. This article suggests the ways of the time adjusting and air-conditioning to satisfy customer's demand and the guide line to design the optimum capacity of air-conditioner of the new electric rail car which will be introduced in the near future.

  • PDF

Effects of Fertilizer Level in Nursery on Dry Stem Yield and Quality of Mat Rush (Juncus effusus L. var. decipiens Buchenan) (골풀 묘상 시비량이 건경 수량과 품질에 미치는 영향)

  • Shin, Dong-Young;Jung, Dong-Soo;Hyun, Kyu-Hwan;Seo, Young-Nam;Lim, June-Taeg;Kwon, Byung-Sun
    • Korean Journal of Plant Resources
    • /
    • v.20 no.4
    • /
    • pp.309-311
    • /
    • 2007
  • This study was conducted to select the most suitable fertilizer level on nursery of mat rush for good quality and high yield. $N-P_{2}O_{5}-K_{2}O=60-30-60$ (kg/10a), fertilizer level on nursery of mat rush showed relatively superior values for all yield components and quality with 57g in fresh weight, 12g in dry weight, 23% in air drying ratio for per plant at the nursery and 125cm in stem length, 150 numbers in stem number, 4,082kg/10a in fresh stem yield, 345kg/10a in long stem yield, 996kg/10a in medium stem yield, 1,421kg/l0a in total stem yield, 34% in dry stem ratio and 30% in long stem ratio at the main paddy field. The results indicate that fertilizer level, $N-P_{2}O_{5}-K_{2}O=60-30-60kg/10a$ in nursery shows different adaptabilities to a particular fertilizer level and 60-30-60 (kg/10a) seems to be the most suitable fertilizer level of mat rush for good quality and high yield.

A research to decrease Formaldehyde on the train (전동차내 폼알데하이드 저감방안에 관한 연구)

  • Choi, Sung-Ho;Choi, Soon-Gi;Son, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1009-1013
    • /
    • 2011
  • Seoul Metro Line 1 to 4 guests per day to 4.5 million people have been using the subway. This is close to the city population, 57 percent of people use the subway and found that 57 percent of people use the subway and found that this is close to the city population. Motor vehicle indoor air quality, especially of the major factors affecting is passenger's clothing, cosmetics, adhesives and formaldehyde by the action and so are able to keep. Enclosure 30ppm formaldehyde during prolonged exposure at concentrations above the nose, bronchial cough and a burning can cause symptoms. It is necessary to introduce an appropriate ventilation system. 1-4 Line Press in 2008, leaving the subway, and normally the train measured in room air quality. Measurements in 2005, $19.3{\sim}83{\mu}g/m^3$, 2008 Year ND ~ $61.7{\mu}g/m^3$ is. When congestion(rush hour) to temporarily increase the formaldehyde can result in a higher number. Automatic detection of formaldehyde and improve ventilation to a practical system, and it is necessary to chatneun. In research since 2006, Removal of formaldehyde were analyzed for the study. the passengers on the effects of formaldehyde in rush hour, the plan for increasing the ventilation through the analysis of various factors, such as electric vehicle practical ways to improve air quality have been studied.

  • PDF

A Prediction of $CO_2$ Concentration and Measurement of Indoor Air Quality in the EMU (전동차 실내공기질 측정 및 $CO_2$ 농도 예측)

  • So, Jin-Sub;Yoo, Seong-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.4
    • /
    • pp.378-383
    • /
    • 2008
  • In December 2006, the Ministry of Environment Republic of Korea established the guideline which is "Indoor Air Quality Management Guidelines in Public Transportation." as control items, $CO_2$ (carbon dioxide) and PM10 (particle matter) are classified two categories, that is, Level 1 (non-rush hour), Level 2 (rush hour). Therefore, the quality of air in train and subway should be controlled in accordance with the guideline. We took a measure the air freshness inside train twice at Line 4 (Tangogae-Oido), in Sep. 2007 and at Line 1 (Dongincheon-Yongsan) in Nov. 2007, respectively and, also expected the emitted $CO_2$ concentration by using a property of matter such as EMU (Electric Multiple Unit) design reviewing specification and air. According to the measured values, the concentration of PM10 was 44, 57, 45% and the concentration of $CO_2$ was 39, 36, 44% respectively, all measured values are within the guideline and also, as a result we found the expected value and measured value are similar.

A Study on the Controller for Reducing of In-Rush Current of Inductive Load (유도성 부하의 돌입전류저감을 위한 제어기에 관한 연구)

  • Park, Su-Kang;Cho, Geum-Bae;Baek, Hyung-Lae;Lim, Yang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1345-1347
    • /
    • 2000
  • This paper presents a new method to reducing inrush current and energy saving of capacitor starting single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

A Study on the Relationship between the Traffic Signal System and the Air Pollutants emitted by the Motor Vehicles at Intersection

  • Hong, Min-Sun;Woo, Wan-Gi;Park, Jong-In
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.E
    • /
    • pp.364-372
    • /
    • 1993
  • The purpose of this study is to analyze traffic patterns by use of TRANSYT-7F Model, and to choose the optimum traffic-light cycle length and cycle splite to improve traffic flow and air quality at Samsung Intersection in Seoul. Emission rates of air pollutants are calculated for three time segments 0700-0900, 0900-1800 and 1800-2000. The traffic volume correlated reasonably well with air pollutants emitted ; however, the phasing and timing of traffic signals was found to equally be important. The results of performance with optimal setting indicate that the best cycle length were 80sec(0700-0900), 95sec(0900-1800) and 90sec(1800-2000), res-pectively. As expected the highest emissions of air pollutants were observed during the evening rush hours (1800-2000). A properly designed signalized intersection can help reduce traffic delay, driver discomfort, fuel consumption, and air pollution by efficiently the capacity of existing intersection.

  • PDF

A Study on the Variation of Air Pollutants Emission Rates for Different Traffic Signal System in Metropolitan Area (대도시 교통신호시스템에 따른 대기오염물질 배출량 변화에 관한 연구)

  • 홍민선;우완기;최종인
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.93-100
    • /
    • 1993
  • This study was carried out to investigate the relationship between the traffic signal systmes and the air pollutants emitted by the motor vehicles at Kangnam Intersection. One of the most important measures of effectiveness (MOE) in traffic studies is the delay to vehicles in the system. Delay represents indirect costs to the motorist in terms of time loss and a direct cost in terms of fuel consumption during idling. The results of TRANSYT-7F modeling was correlated among delay, fuel consumption and total travel tiem. Air pollutants emission rate can be calculated by the results of modeling and the Korean type emission factor. As expected the highest emissions, for air pollutants, are observed during the morning rush hours (07 : 00-10 : 00). For better results of modeling, the TRANSYT-7F model needs to modify for the Korean type of traffic model. The results of this study indicate that the variation of air pollutants emission rates were closely related to the traffic signal system.

  • PDF

A Study of Black Carbon Measurement in Metropolitan Area and Suburban Area of the Korean Peninsula Performed during Pre KORea-US Air Quality Study (KORUS-AQ) Campaign (한반도 수도권 및 준 수도권 지역의 블랙 카본 측정 연구: 한-미 협력 국내 대기질 공동 조사 연구 (KORea-US Air Quality Study, KORUS-AQ) 예비캠페인 기간을 중심으로)

  • Lee, Jeonghoon;Jeong, Byeongju;Park, Da-Jeong;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.5
    • /
    • pp.472-481
    • /
    • 2015
  • Black carbon (BC) aerosols were monitored at the KIST site ($37.603^{\circ}N$, $127.046^{\circ}E$) and Cheonan-KOREATECH site ($36.766^{\circ}N$, $127.281^{\circ}E$) during the pre KORea-US Air Quality Study (KORUS-AQ) campaign using a couple of Muliti Angle Absorption Photometers (MAAP). BC mass concentrations were presented as $2.14{\pm}1.06{\mu}g/m^3$ and $0.94{\pm}0.60{\mu}g/m^3$ at KIST site (Seoul) and KOREATECH site (Cheonan), respectively. BC mass concentrations measured at KIST and KOREATECH sites from 22:00 on May 22 to 12:00 on May 23, 2015 showed 80% and 72% higher than average BC mass concentrations measured during campaign period, respectively. It indicates both sites could be influenced by a remote source. Similar patterns of BC concentrations between two sites from 20:00 to 24:00 on June 6, 2015 implies that the BC could be transported into both sites and then be stagnant inside the Korean Peninsula. Diurnal variation of BC in weekdays and weekends were also presented for the KIST and KOREATECH sites. Morning rush hour peak was observed at KIST site located in metropolitan area though no distinct morning rush hour peak was not observed at KOREATECH site located in a suburban area. This study revealed transport pathways of BC near the Korean Peninsula using back-trajectory analysis of BC measured both in a metropolitan area and in a suburban area.

Black Carbon Pollution Level at a Roadside of Seoul in Spring (봄철 서울 도로변의 검댕 오염 특성)

  • Lee, Seung-Bok;Bae, Gwi-Nam;Park, Su-Mi;Jung, Sang-Geun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.4
    • /
    • pp.466-477
    • /
    • 2007
  • To understand particle pollution phenomena caused by vehicles, black carbon (BC) concentrations were continuously monitored using an aethalometer at a roadside in Seoul during the period of May 79 to 25, 2005. The BC concentration was highly fluctuated for a short duration, responding to the traffic situation on the road. The lowest BC concentration was observed between 2 and 5 a.m. The local highest BC concentrations were observed during the periods of both morning and evening rush hours. Change in traffic volume accounts for the trend of hourly averaged BC concentrations from the late evening to the morning. Particularly, the slower increase of BC concentration on Sunday seems to respond directly the lower traffic volume in the morning rush hours. From the comparison with a previous work, it is concluded that the BC concentration around midday hours might be dependent on the distance from a road.