• 제목/요약/키워드: Air quality standards

검색결과 256건 처리시간 0.035초

MCNP 시뮬레이션을 통한 450 kVp 엑스레이 튜브의 콘크리트 차폐벽 두께 계산 및 반가층 방법을 이용한 계산과의 결과 비교 (Calculation of Concrete Shielding Wall Thickness for 450 kVp X-ray Tube with MCNP Simulation and Result Comparison with Half Value Layer Method Calculation)

  • 이상헌;허삼석;이은중;김찬규;조규성
    • 방사선산업학회지
    • /
    • 제10권1호
    • /
    • pp.29-35
    • /
    • 2016
  • Radiation generating devices must be properly shielded for their safe application. Although institutes such as US National Bureau of Standards and National Council on Radiation Protection and Measurements (NCRP) have provided guidelines for shielding X-ray tube of various purposes, industry people tend to rely on 'Half Value Layer (HVL) method' which requires relatively simple calculation compared to the case of those guidelines. The method is based on the fact that the intensity, dose, and air kerma of narrow beam incident on shielding wall decreases by about half as the beam penetrates the HVL thickness of the wall. One can adjust shielding wall thickness to satisfy outside wall dose or air kerma requirements with this calculation. However, this may not always be the case because 1) The strict definition of HVL deals with only Intensity, 2) The situation is different when the beam is not 'narrow'; the beam quality inside the wall is distorted and related changes on outside wall dose or air kerma such as buildup effect occurs. Therefore, sometimes more careful research should be done in order to verify the effect of shielding specific radiation generating device. High energy X-ray tubes which is operated at the voltage above 400 kV that are used for 'heavy' nondestructive inspection is an example. People have less experience in running and shielding such device than in the case of widely-used low energy X-ray tubes operated at the voltage below 300 kV. In this study, Air Kerma value per week, outside concrete shielding wall of various thickness surrounding 450 kVp X-ray tube were calculated using MCNP simulation with the aid of Geometry Splitting method which is a famous Variance Reduction technique. The comparison between simulated result, HVL method result, and NCRP Report 147 safety goal $0.02mGy\;wk^{-1}$ on Air Kerma for the place where the public are free to pass showed that concrete wall of thickness 80 cm is needed to achieve the safety goal. Essentially same result was obtained from the application of HVL method except that it suggest the need of additional 5 cm concrete wall thickness. Therefore, employing the result from HVL method calculation as an conservative upper limit of concrete shielding wall thickness was found to be useful; It would be easy, economic, and reasonable way to set shielding wall thickness.

열풍 건조와 태양 건조한 국내산 고추의 물리화학적 및 미생물학적 품질 특성 비교 (Comparison of physicochemical and microorganism characteristics between the air-dried and sun-dried red pepper in south Korea)

  • 구경형;이경아;구민선
    • 한국식품저장유통학회지
    • /
    • 제21권4호
    • /
    • pp.451-459
    • /
    • 2014
  • 본 연구는 국내에서 유통되고 있는 국내산 건고추의 품질 기준을 제시하기 위하여 농가에서 가장 많이 사용하고 있는 열풍 건조한 고추와 소비자가 선호하는 태양 건조한 고추를 지역별로 수집하여 물리화학적 및 미생물학적 품질비교를 하였다. 열풍건조한 고추와 태양 건조 고추의 건물량으로 환산한 캡사이신노이드 함량의 경우 열풍건조 시료는 10.85~126.39 mg%, 태양 건조 시료는 0.43~164.09 mg%로 넓은 범위의 분포도를 나타내었고, 총 유리당 함량은 각각 10.82~20.77%, 9.26~23.10%로 건조 방법에 따른 뚜렷한 차이를 보이지 않았다. 그러나 ASTA 값과 비타민 C 함량의 경우, 열풍건조 시료는 49.12~154.69, 0.0~1,010 mg%, 태양건조 시료는 70.08~182.13, 620~1,050 mg%로 태양건조 시료가 열풍건조 시료보다 높은 범위의 값을 보였다. 총균수와 효모의 경우, 열풍건조 시료군은 2.01~6.67 log CFU/g, 1.03~4.12 log CFU/g이었고, 태양 건조 시료군은 1.74~5.77 log CFU/g, 1.05~6.10 log CFU/g이었다. 또 병원성 미생물인 Clostridium perfringens와 Bacillus cereus도 건조 방법에 상관없이 검출되었다. 한편 이들 품질 특성들을 이용한 주성분 분석 결과 제1요인은 38.47%, 제2요인은 18.31%였고, 총 설명력은 56.78%였다. PC1은 비타민 C, ASTA값, 색도와 관련이 있었고, PC 2는 수분함량, 미생물 수, 건조 방법과 관련이 있었다. 본 연구결과는 국내에서 유통되고 있는 고춧가루의 건조방법에 따른 품질 차이와 미생물의 오염도가 확인되었고, 소비자가 원하는 고추 품질 지표에 유용한 정보로 활용될 수 있을 것으로 기대된다.

대기오염에 의한 폐암 및 만성폐색성호흡기질환 -개인 흡연력을 보정한 만성건강영향평가- (Lung cancer, chronic obstructive pulmonary disease and air pollution)

  • 성주헌;조수헌;강대희;유근영
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권3호
    • /
    • pp.585-598
    • /
    • 1997
  • Background : Although there are growing concerns about the adverse health effect of air pollution, not much evidence on health effect of current air pollution level had been accumulated yet in Korea. This study was designed to evaluate the chronic health effect of ai. pollution using Korean Medical Insurance Corporation (KMIC) data and air quality data. Medical insurance data in Korea have some drawback in accuracy, but they do have some strength especially in their national coverage, in having unified ID system and individual information which enables various data linkage and chronic health effect study. Method : This study utilized the data of Korean Environmental Surveillance System Study (Surveillance Study), which consist of asthma, acute bronchitis, chronic obstructive pulmonary diseases (COPD), cardiovascular diseases (congestive heart failure and ischemic heart disease), all cancers, accidents and congenital anomaly, i. e., mainly potential environmental diseases. We reconstructed a nested case-control study wit5h Surveillance Study data and air pollution data in Korea. Among 1,037,210 insured who completed? questionnaire and physical examination in 1992, disease free (for chronic respiratory disease and cancer) persons, between the age of 35-64 with smoking status information were selected to reconstruct cohort of 564,991 persons. The cohort was followed-up to 1995 (1992-5) and the subjects who had the diseases in Surveillance Study were selected. Finally, the patients, with address information and available air pollution data, left to be 'final subjects' Cases were defined to all lung cancer cases (424) and COPD admission cases (89), while control groups are determined to all other patients than two case groups among 'final subjects'. That is, cases are putative chronic environmental diseases, while controls are mainly acute environmental diseases. for exposure, Air quality data in 73 monitoring sites between 1991 - 1993 were analyzed to surrogate air pollution exposure level of located areas (58 areas). Five major air pollutants data, TSP, $O_3,\;SO_2$, CO, NOx was available and the area means were applied to the residents of the local area. 3-year arithmetic mean value, the counts of days violating both long-term and shot-term standards during the period were used as indices of exposure. Multiple logistic regression model was applied. All analyses were performed adjusting for current and past smoking history, age, gender. Results : Plain arithmetic means of pollutants level did not succeed in revealing any relation to the risk of lung cancer or COPD, while the cumulative counts of non-at-tainment days did. All pollutants indices failed to show significant positive findings with COPD excess. Lung cancer risks were significantly and consistently associated with the increase of $O_3$ and CO exceedance counts (to corrected error level -0.017) and less strongly and consistently with $SO_2$ and TSP. $SO_2$ and TSP showed weaker and less consistent relationship. $O_3$ and CO were estimated to increase the risks of lung cancer by 2.04 and 1.46 respectively, the maximal probable risks, derived from comparing more polluted area (95%) with cleaner area (5%). Conclusions : Although not decisive due to potential misclassication of exposure, these results wert drawn by relatively conservative interpretation, and could be used as an evidence of chronic health effect especially for lung cancer. $O_3$ might be a candidate for promoter of lung cancer, while CO should be considered as surrogated measure of motor vehicle emissions. The control selection in this study could have been less appropriate for COPD, and further evaluation with another setting might be necessary.

  • PDF

NCS 기반 토양환경분야 국가기술자격 실기시험 평가방법에 관한 연구 (A Study on the Evaluation Method of National Technical Qualification for Soil Environment Based on NCS)

  • 이정규;배재근
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권5호
    • /
    • pp.98-104
    • /
    • 2017
  • Human Resources Development of Korea has been practicing performance evaluation for occupational qualification licences in environmental sectors that include water, air, and wastes management, but not soil. The purpose of the study was to improve overall quality of the national qualification test in the soil sector to better train applicants based on National Competency Standards (NCS), which is designed to emphasize site-specific conditions and knowledge. This study systematically analysed the current licence test in the soil sector with respect to qualification units, performance criteria, knowledge, techniques, and attitude as described in NCS. Furthermore, test evaluation was conducted to examine the validity of the revised licence test. The test results indicated the revised test method would bring positive outcomes to the related industry. Upon the reviews and amendments by the field experts, the result of this study could serve as a framework to the development of more robust and reliable licence test.

녹색보험산업의 발전방안에 관한 연구 (A Study on the Improvement Plans of Green Insurance Industry)

  • 한낙현;조성우;김은주
    • 무역상무연구
    • /
    • 제57권
    • /
    • pp.305-331
    • /
    • 2013
  • The purpose of this study aims to the improvement prospect of green insurance industry in Korea. Green insurance includes all classes of general insurance business including unoccupied property insurance and empty building insurance, business insurance, personal insurance, etc. Green policies often cover expensive systems that are not covered under most property policies. The same is true for some underground property, which is also exempted from many property policies. At least insurers already offer products designed to fund rebuilding damaged properties to meet certain environmental and building standards. While the products are in their infancy, insurers and brokers say the huge interest in environmental issues will increase demand. Green buildings that improve energy efficiency and air quality and reduce waste are designed to reduce their effects on the environment and the health of building occupants. Buildings account for 39% of U.S. carbon dioxide emissions, according to the Department of Energy. Insurers say that, as sustainable buildings become more common, green insurance will become more popular and some of its features might become a standard part of property policies.

  • PDF

Toxic Trace and Earth Crustal Elements of Ambient PM2.5 Using CCT-ICP-MS in an Urban Area of Korea

  • Lee, Jin-Hong;Jeong, Jin-Hee;Lim, Joung-Myung
    • Environmental Engineering Research
    • /
    • 제18권1호
    • /
    • pp.3-8
    • /
    • 2013
  • Collision cell technology-inductively coupled plasma-mass spectrometry (CCT-ICP-MS) was used to measure the concentrations of approximately 19 elements associated with airborne PM2.5 samples that were collected from a roadside sampling station in Daejeon, Korea. Standard reference material (SRM 2783, air particulate on filter media) of the National Institute of Standards and Technology was used for the quality assurance of CCT-ICP-MS. The elemental concentrations were compared statistically with the certified (or recommended) values. The patterns of distribution were clearly distinguished between elements with their concentrations ranging over four orders of magnitude. If compared in terms of enrichment factors, it was found that toxic trace elements (e.g., Sb, Se, Cd, As, Zn, Pb, and Cu) of anthropogenic origin are much more enriched in PM2.5 samples of the study site. To the contrary, the results of the correlation analysis showed that PM2.5 concentrations can exhibit more enhanced correlations with the elements (e.g., Fe, K, Si, and Ti) arising from earth's crust. The findings of strong correlations between PM2.5 and the elements of crustal origin may be directly comparable with the dominant role of those species by constituting a major fraction of even PM2.5 as well as PM10 at the roadside area.

Looking through the Mass-to-Charge Ratio: Past, Present and Future Perspectives

  • Shin, Seung Koo
    • Mass Spectrometry Letters
    • /
    • 제12권4호
    • /
    • pp.126-130
    • /
    • 2021
  • The mass spectrometry (MS) provides the mass-to-charge ratios of atoms, molecules, stable/metastable complexes, and their fragments. I have taken a long journey with MS to address outstanding issues and problems by experiments and theory and gain insights into underlying principles in chemistry. By looking through the mass-to-charge ratio, I have studied thermochemical problems in silicon chemistry, the infrared multiphoton dissociation spectroscopy of organometallic intermediates, unimolecular dissociations of halotoluene radical cations, and the kinetics of association/dissociation of alkali halide triple ions with Lewis bases. Various MS platforms have been used to characterize non-covalent interactions between porphyrins and fullerenes and those between the group IIB ions and trioctylchalcogenides, and to examine the binding of the group IA, IIA and porphyrin ions to G-quadruplex DNA. Recently, I have focused on mass-balanced H/D isotope dipeptide tags for MS-based quantitative proteomics, a simple chemical modification method for MS-based lipase assay, and the kinetics and dynamics of energy-variable collision-induced dissociation of chemically modified peptides. Now, I see an important role of MS in global issues in the post-COVID era, as the society demands high standards for indoor air quality to contain the airborne-pathogen transmission as well as in-situ monitoring and tracking of carbon emissions to reduce global warming.

노후건축물 비구조체 해체과정에서의 총부유세균 발생량측정에 관한 연구 (A Study on the Measurement of Total Airborne Bacteria in the Process of Dismantling the Non-structure of Old Building)

  • 손병훈;강경하;이지수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.313-314
    • /
    • 2021
  • An old building over 30 years old continue to increase. Therefore, there will be more dismantling of old buildings in the future. Safety management of dismantling works is being strengthened. However, no consideration has been given to the effects of dismantling workers and their residents due to environmental hazards arising from the demolition process. Only spray and dust prevention measures are subject to inspection to minimize dust generation considering civil complaints around the site of dismantling work. In this paper, residential buildings, which account for the largest proportion of old buildings, were collected and identify total airborne bacteria and floating fungi among environmental hazards caused by non-structural dismantling work. Measurement results showed that workers during dismantling work are working in places with 4.8 times more total airborne bacteria than indoor air quality maintenance standards. Related research is needed for the health of dismantling workers.

  • PDF

입상형 활성백토의 입자크기에 따른 수성도료의 특성 (Properties of Water-Based According to Particle Size of Granular Activated Clay)

  • 최병철;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.19-20
    • /
    • 2021
  • In order to reduce the emission of harmful substances that degrade indoor air quality, the Ministry of Environment strengthened the standards for the content of VOCs in paints to supply and sell eco-friendly paints. In this related study, an eco-friendly paint mixed with a powder-type absorbent material was prepared and its characteristics were reviewed. As the amount of powder-type absorbent material increased, the workability (viscosity, peeling, etc) decreased. Accordingly, this study aims to examine which particle size is suitable according to the particle size of the granular adsorbent while improving the problem of the powdery adsorbent by using the granular adsorbent. As an experimental plan, the particle size of granular activated clay is selected to be 0.250, 0.425, 0.710(mm), and the decrease rate of VOCs concentration and impact resistance are reviewed. As a result of the experiment, as the particle size of the granular activated clay increased, the decrease rate of the VOCs concentration increased and the impact resistance improved. Therefore, considering the problems that occur after actual painting, the particle size of granular activated clay of 0.425mm is suitable.

  • PDF

Anti-corrosion impact of green synthesis of Silica nanoparticles for the sports structures in physical exercise activities

  • Zhixin Zhang;Zhiqiang Cai;Khidhair Jasim Mohammed;H. Elhosiny Ali
    • Advances in concrete construction
    • /
    • 제15권1호
    • /
    • pp.41-46
    • /
    • 2023
  • Sport has no age limit and can be done anywhere and in any condition with minimal equipment. The existence of sports spaces in all parts of the world is considered a citizen's right. One of the activities carried out in this field is installing sports equipment and structures in parks and encouraging citizens to use this equipment for physical health with the least cost and facilities. Installing sports structures in open spaces such as parks is a practical step for developing citizens' sports. Although using devices in parks is acceptable, it is more critical to meet scientific and technical standards. The components of these structures must have high strength and endurance against changes in environmental conditions such as humidity, temperature difference, and corrosion. Among the various causes of material degradation, corrosion has always been one of several fundamental causes of metal equipment failure. Sports structures in open spaces are not safe from corrosion. Uniform corrosion is the most common type of corrosion. This corrosion usually occurs uniformly through a chemical or electrochemical reaction across the surface exposed to the corrosive environment. Rust and corrosion of outdoor sports structures are examples of this corrosion. For this reason, in this research, with the green synthesis of silica nanoparticles and its application in outdoor sports structures, the life span of these structures can be increased for the use of physical exercises as well as their quality.