RALS에 장착한 Ir-192 선원의 강도측정에 대한 고찰 (Calibration of an $^{192}Ir$ Source Used for High Dose Rate RALS.)

  • 문언철
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.56-60
    • /
    • 1994
  • In the past, brachytherapy was carried out mostly with radium or radon sources. Currently. use of artificially produced radionuclially produced radionuclides such as $^{137}Cs,\;^{192}Ir,\;^{198}Au,\;and\;^{125}I$ is rapidly increasing. Although electrons are often used as an alternative to interstitial implants, brachytherapy continues to remain an important mode of therapy, either alone or combined with external beam. The National Council on Radiation Protection and Measurements(NCRP) recommends that the strength of any ${\gamma}$ emitter should be specified directly in terms of exposure rate in air at a specified distance such as 1m. The air kerma strength is defined as the product of air kerma rate in 'free space' and the square of the disrance of the calibration point from the source center along the perpendicular bisector, i. e., $S_k=K_L{\times}L^2$. Where $S_K$ is the the air kerma strength and K is the air kerma rate at a specified distance L. (usually 1m). Recommended units for all kerma strength are ${\mu}Gym^{2}h^{-1}$.

  • PDF

Airborne HPGe spectrometer for monitoring of air dose rates and surface activities

  • Marcel Ohera;Lubomir Gryc;Irena Cespirova;Jan Helebrant;Lukas Skala
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4039-4047
    • /
    • 2023
  • This contribution describes the application of HPGe detector for the airborne quantitative analysis. The hardware of the airborne HPGe system was designed from the commercial components with only exception of the newly designed AirHPGeSpec special software to control, measure and process the data. The system was calibrated for the local air kerma rates measured on helicopter board and its conversion to the air kerma rates at 1 m above the ground was proposed. Two examples of the air kerma rates measured over the former uranium mining areas are presented and compared with the results of other airborne system on the board. This airborne HPGe system could be also used for measuring the surface activities in a radiation event. The nuclides of 131I, 132Te - 132I, 133I, 134I, 135I, 137Cs, 134Cs, 88Rb and 103Ru were selected from possible nuclear power plant emergency scenarios. The Monte Carlo simulation was used to calculate HPGe detector efficiencies for the flight altitudes from 25 to 300 m for the energies from 300 keV to 3 MeV of the nuclides in question. Also, the detection limits according to the Currie method as well as ISO 11929-2010 for selected nuclides are presented.

Ir-192 고선량률 선원에 대한 공기커마강도의 품질보증 (Quality Assurance of Air Kerma Strength for Ir-192 High Dose Rate Source)

  • 김종언;윤천실;김성현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권2호
    • /
    • pp.147-151
    • /
    • 2007
  • AAPM TG43 프로토콜에서 선원 강도의 측정은 공기커마강도로 권고하고 있다. 본 연구는 제조사에서 제공되는 공기커마강도의 정확성이 ${\pm}5%$ 범위 이내에 있는지 측정으로 검증하는데 목적이 있다. Standard imaging사의 MAX-4001 Electrometer와 HDR 1000 Plus, 그리고 6 french bronchial Applicator를 재료로 사용하여, 이온함의 중심축의 바닥으로부터 10 mm 지점에서 90 mm 지점까지 이온화 전류를 측정하였다. 측정된 이온화 전류 곡선에서 최대 이온화 전류를 나타내는 거리를 교정의 기준점으로 정하고, 이 이온화 전류 측정치로부터 공기커마강도를 구하였다. 이온화 전류 곡선의 정점인 최대 이온화 전류에 대응하는 거리는 50 mm이었다. 이 거리는 UW-ADCL의 교정 검증서의 선원의 기준점과 완전히 일치하였다. 측정으로 계산된 공기커마강도는 제조사에서 제공된 교정치보다 약 0.5% 더 높게 측정되었다. 제조사에서 제공되는 교정 검증서의 공기커마강도는 신뢰할 수 있는 정확성을 가졌다는 결과를 얻었다. 측정에서 우물형 이온함 안의 dead space의 길이와 선원의 dwell position으로 이동 오차 그리고 산란선의 영향 등을 고려하면, 정확한 측정과 교정의 결과를 얻을 수 있다고 생각된다.

  • PDF

근접조사용 Ir-192 마이크로선원의 디자인과 선량 특성 (The Dose Characteristics of Designed Ir-192 Micro-source for Brachytherapy)

  • 최태진;김진희
    • 한국의학물리학회지:의학물리
    • /
    • 제14권2호
    • /
    • pp.81-89
    • /
    • 2003
  • 근접조사용 선원으로 직경이 0.5 mm에 길이 3.5 mm인 Ir-192선원을 고안하고, 선량알고리즘을 개발하였다. 선원을 0.1 mm 두께로 균등분할하고 총 875개의 미소선원으로부터 조직에 도달되는 선량을 계산하고 선량분포를 조사하였다. 선원을 감싸는 캡슐용기의 두께는 0.3 mm이며, 선량기준점인 Ir선원의 Air-kerma strength(S$_{k}$ ) 는 mCi당 4.108U를 얻었으며 선원 측방의 1 cm에서 1.154 Uh$^{-1}$ (1.3167${\times}$$10^{-3}$cGy/mCi-sec)의 조직선량률을 얻었다. Air-kerma strength로부터 조직내 선량률상수(Λ)는 Ir-192에너지 스펙트럼과 실험치인 조직내 산란보정계수를 적용하여 1.154 cGy h$^{-1}$U$^{-1}$ 얻었다. 선량분포의 특성은 선원 축방향으로 56%의 상대선량률을 보였고, 케이블측의 선량감쇠는 50%를 보였다. 마이크로선원의 중심에서 반경 1 cm 주위의 선량분포와 5 cm의 선량분포를 비교한 결과 반경이 큰 경우의 측방선량에 비해 축 방향의 선량이 약 2% 감쇠함을 보았다. 선원자체의 필터효과는 점선원에 비해 88.3%의 선량률을 얻어 약 12%의 감쇠를 보였으며, 캘슐벽의 필터효과는 약 3% 정도로 미미하게 나타났으며 기준점에서 선량필터효과는 약 15.6% 감쇠되는 것으로 나타났다. Ir-192 선원과 같이 에너지가 낮은 선원을 사용하는 경우 선량분포특성에 따라 아프리케이터의 직경을 크게 하여 선원 축 방향의 선량저하를 피할 수 있음을 알 수 있었다.

  • PDF

Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

원통형 전리함을 이용한 Ir-192 선원에 대한 공기커마세기 측정 시 선질보정에 관한 연구 (Quality Correction for Ir-192 Gamma Rays in Air Kerma Strength Dosimetry Using Cylindrical Ionization Chambers)

  • 정동혁;김진기;김기환;오영기;김수곤;이강규;문성록
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.30-36
    • /
    • 2009
  • Co-60 선원에 대해 교정된 원통형 전리함 이용하여 Ir-192 선원에 대한 공기커마세기를 측정하는 경우에 선질 차이에 대한 보정이 필요하다. 본 연구에서는 측정학적 방법을 적용하여 PTW-N30001과 N23333 전리함에 대하여 Ir-192 감마선에 대한 선질 인자를 결정하였다. Ir-192 선원(microSelectron)의 에너지스펙트럼을 적용할 경우에 선질인자($k_u$)는 두 전리함에 대해 각각 $k_u$=1.016 (N30001)과 $k_u$=1.017 (N23333)으로 계산되었다. 치료용 microSelectron 선원에 대해 선질 인자를 적용하여 공기커마 세기를 측정하였으며 결과를 기준값과 비교하였다. 결과적으로 선질인자를 적용하는 경우에 기준 공기커마율과 약 -0.5% 이내의 차이를 보였으며 적용하지 않는 경우에는 약 -2.0%의 차이를 보였다.

  • PDF

코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성 (Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source)

  • 최태진;이호준;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.259-266
    • /
    • 1998
  • 코발트-60 근접조사선원을 대체할 Ir-l92 선원주변의 2차원적 선량분포를 얻기 위하여, 조사선량률과, 조직감쇠계수를 구하였다. 조직감쇠계수는 선원에서 20 cm 지점까지 실험식을 구하였다. ?보기 방사능은 조사선량상수를 사용하여 결정하였으며, 2.5mm 직경에 두께 2.5 mm 의 선원은 조직선량을 정하기 위해 선원을 4401 개로 분할하여 선원 자체의 흡수효과와 ?슐벽의 차폐 효과와 조직감쇠계수를 적용하였다. 조직감쇠계수는 4차식을 사용하여 1% 오차범위내에서 실험값을 얻을 수 있었으며, Meisberger 상수는 선원에서 많이 떨어질수록 오차가 커서, 10 cm 위치서 7%, 20 cm 에서 33%의 오차를 발견할 수 있었으나, 겉보기방사능과 선원모양 및 크기가 달라 다른 결과를 가져올 수 있다고 본다. 발표된 Ir-192 선원의 에너지스펙트럼을 이용한 선량률상수는 절삭에너지 10 keV인 경우 4.69 R$cm^2$/mCi-hr을 얻었으며 Air Kerma는 0.973 을 구하였다. 이 실험에서 고안 선원의 분할선원에 의한 선원자체흡수와 ?슐벽에 의한 감쇠는 실선원의 54.6%가 겉보기방사능으로 나타남을 알 수 있었으며, 선량계획에 이용하기 위해 단위 ?보기 방사능에 대한 2차원적 선량표를 준비함으로써 기하학적선량과 선량 비등방성을 쉽게 이용할 수 있도록 하였다.

  • PDF

IPEM Report-78의 엑스선 스펙트럼을 이용한 방사선 방호장비의 차폐율 계산 (Calculation of Shielding Rate of Radiation Protective Equipment Using the X-ray Spectrum of IPEM Report-78)

  • 한동현
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.755-760
    • /
    • 2021
  • 본 연구에서는 IPEM(The Institute of Physics and Engineering in Medicine) Report 78의 진단용 엑스선 발생장치에서 방출되는 엑스선 스펙트럼 데이터를 이용하여 의료 환경에서 사용되는 주요 엑스선 방호장비의 차폐율을 계산하고, 방사선 방호분야 적용가능성을 알아보았다. 진단용 엑스선 방호에 이용되는 납 앞치마(0.3 mmPb), 갑상샘 차폐체(0.5 mmPb), 납 고글(0.5 mmPb), 납 유리(1.8, 2.7, 3.3 mmPb)를 대상으로 에어커마와 엑스선 총강도의 감소율을 통해 방사선 차폐율을 계산하였다. 그 결과 에어커마 감소율로 계산한 차폐율은 80 kV에서 96.31~100 %범위였고, 120 kV에서는 90.35~100%범위로 나타났다. 또한 본 계산의 결과가 실제 차폐율 측정한 선행연구결과와 잘 일치하여 IPEM Report 78의 엑스선 스펙트럼 데이터가 방사선 방호에 활용될 수 있을 것으로 기대된다.

X-Rays through the Looking Glass: Mobile Imaging Dosimetry and Image Quality of Suspected COVID-19 Patients

  • Schelleman, Alexandra;Boyd, Chris
    • Journal of Radiation Protection and Research
    • /
    • 제46권3호
    • /
    • pp.120-126
    • /
    • 2021
  • Background: This paper aims to evaluate the clinical utility and radiation dosimetry, for the mobile X-ray imaging of patients with known or suspected infectious diseases, through the window of an isolation room. The suitability of this technique for imaging coronavirus disease 2019 (COVID-19) patients is of particular focus here, although it is expected to have equal relevance to many infectious respiratory disease outbreaks. Materials and Methods: Two exposure levels were examined, a "typical" mobile exposure of 100 kVp/1.6 mAs and a "high" exposure of 120 kVp/5 mAs. Exposures of an anthropomorphic phantom were made, with and without a glass window present in the beam. The resultant phantom images were provided to experienced radiographers for image quality evaluation, using a Likert scale to rate the anatomical structure visibility. Results and Discussion: The incident air kerma doubled using the high exposure technique, from 29.47 µGy to 67.82 µGy and scattered radiation inside and outside the room increased. Despite an increase in beam energy, high exposure technique images received higher image quality scores than images acquired using lower exposure settings. Conclusion: Increased scattered radiation was very low and can be further mitigated by ensuring surrounding staff are appropriately distanced from both the patient and X-ray tube. Although an increase in incident air kerma was observed, practical advantages in infection control and personal protective equipment conservation were identified. Sites are encouraged to consider the use of this technique where appropriate, following the completion of standard justification practices.

Intercomparison of KAERI Reference Photon Radiation Fields

  • S.Y.Chang;J.C.MacDonald;M.K.Murphy;Kim, B.H.;Lee, K.C.
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(4)
    • /
    • pp.34-39
    • /
    • 1996
  • A series of measurements was peformed between KAERI and PNNL, U.S.A at KAERI secondary calibration laboratory to intercompare and verify the KAERI reference photon radiation fields by using air equivalent plastic walled ionization chambers, Different ionization chambers of two laboratories were used to determine the air kerma rate, free-in-air, at reference positions in the KAERI photon radiation fields, As the results, the agreement in the cross measurements between two laboratories was found to be within less than ${\pm}$ 3 %. This degree of consistency was considered to be encouraging, because each laboratory maintains independently its calibration traceablity with its national primary standard