• Title/Summary/Keyword: Air jet

Search Result 941, Processing Time 0.028 seconds

A Study on the Heat Transfer Enhancement by Trapezoid Rod in Impinging Jet System (충돌분류계에서 사다리형 로드를 이용한 열전달증진에 관한 연구)

  • Lim, T.S.;Kum, S.M.;Lee, C.E.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.565-571
    • /
    • 2001
  • The objective of this study was to investigate the characteristics of air flow and heat transfer caused by trapezoid rods array in impinging air jet system. In this study, trapezoid rods have been set up on front of flat plate to act as a turbulence promoter. Local Nusselt numbers were determined as a function of three parameters: (a) the space from rods to heating surface(C=1, 2, 4mm), (b) the pitch between each rods(P=30, 40, 50mm), (c) the distance from nozzle exit to flat plate(H/B=2, 6, 10). And this research compared the above with the experiment without trapezoid rods. As a result, heat transfer performance was best under the condition of C=1mm and as the pitch is 30mm. In this case, maximum rate of heat transfer augmentation is about 1.9 times greater compared to that without trapezoid rods.

  • PDF

Experimental study on impeller discharge flow of a centrifugal compressor (원심 압축기 임펠러 출구 유동에 관한 실험적 연구)

  • 신유환;김광호;손병진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.483-494
    • /
    • 1998
  • This study describes the characteristics on impeller discharge flow of a centrifugal compressor with vaneless diffuser. Distorted flow at impeller exit was investigated by measuring of unsteady velocity fluctuation using hot-wire anemometer. As a result, a wake region appears near shroud side and moves to suction side and also to hub side as flow rate decreases. Jet, wake, and their boundary region which can be defined in jet-wake flow model are clearly observed at a high flow rate for the flow coefficient of 0.64, however, as flow rate decreases to the flow coefficient of 0.19, the classification of their regions disappears. Turbulence intensity also increases as flow rate decreases. Measurement error from uncertainty analysis is estimated about 4% at the flow coefficient of 0.19

  • PDF

On the Effect of Presumed PDF and Intermittency on the Numerical Simulation of a Diffusion Flame

  • Riechelmann, Dirk;Fujimori, Toshiro
    • Journal of the Korean Society of Combustion
    • /
    • v.6 no.2
    • /
    • pp.23-28
    • /
    • 2001
  • In the present work, the effect of PDF selection and intermittency on the result of the numerical simulation are examined by the simulation of a turbulent methane-air jet diffusion flame. As to the PDFs, beta-function and clipped Gaussian are considered. Results for the pure mixing jet are compared with experimental results. Then, the turbulent flame is calculated for the same conditions and the results obtained for the several models are compared. It is found that the clipped Gaussian distribution coupled with consideration of intermittency recovers the experimental data very well. As to the reacting flow results, the main overall properties of the turbulent jet diffusion flame such as maximum flame temperature are less affected by the choice of the PDF. Flame height and NO emissions, on the contrary, appear to be significantly influenced.

  • PDF

A Study on the Design of High-Frequency Jet Ventilator Using PLL system (위상동기루프 방식을 이용한 고빈도 JET환기장치의 설계에 관한 연구)

  • Lee, Joon-Ha;Chung, Jae-Chun
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.63-70
    • /
    • 1989
  • This paper describes to design and to examine the mechanical characteristics of high frequency jet ventilator. The device consists of Phase lock loop(PLL) system, solenoid valve driving control part and Air regulating system. This study is carried out by changing several factors such as endotracheal tube(E.T. tube)diameter, injector cannula diameter, 1%, and frequency(breaths/mim.) having direct effects on the gas exchange as well as parameters of the entrained gas by venturi effects, so as to measure the tidal volume and minute volume. This system characteristics were as follows : 1) Frequency : 6-594bpm 2) Inspiration time : 1-99% 3) Variance of input air pressure : 1-30PSI.

  • PDF

A Study on Saturated Boiling Heat Transfer in Upward Rectangular Impinging Water Jet System (연직상향(鉛直上向) 사각충돌수분류(四角衝突水噴流)의 포화비등 열전달에 관한 연구)

  • Lee, J.S.;Ohm, K.C.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.5
    • /
    • pp.395-403
    • /
    • 1991
  • The purpose of this investigation was to characterize nucleate boiling and burn-out heat flux for rectangular free jet with saturated water impinging perpendicularly and upward against a flat uniform heat flux surface. Heat flux measured for Reynolds number based on rectangular nozzle width and for aspect ratio. The result of nucleate boiling heat transfer was presented nondimensional experimental equation including Nusselt, Boiling, Subcooling, Reynolds and Weber number. The effect of aspect ratio of heated surface in the burn-out heat flux had not appeared distinctly. But for the same aspect ratio, burn-out heat flux increased linearly with increment of nozzle exit velocity.

  • PDF

Effect of Oxygen Enriched Air on the Combustion Characteristics in a Coaxial Non-Premixed Jet ( I ) - Lift-off and Flame Stability - (산소부화공기가 동축 비예혼합 제트의 연소특성에 미치는 영향 (I) - 화염의 부상과 안정성)

  • Kwark, Ji-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.2
    • /
    • pp.160-166
    • /
    • 2004
  • Combustion using oxygen enriched air is known as a technology which can increase flame stability as well as thermal efficiency due to improving the burning rate. Lift-off, blowout limit and flame length were examined as a function of jet velocity, coflow velocity and OEC(Oxygen Enriched Concentration). Blowout limit of the flame below OEC 25% decreased with increase of coflow velocity, but the limit above OEC 25% increased inversely. Lift-off height decreased with increase of OEC. In particular, lift-off hardly occurred in the condition above OEC 40%. Flame length of the flames above OEC 40% was increased until the blowout occurred. Great flame stability was obtained since lift-off and blowout limit significantly increased with increase of OEC.

Heat/mass transfer characteristics of arrays of impingement jets using effusion holes (유출홀을 사용한 배열충돌제트의 열/물질전달 특성)

  • Yoon, P.H.;Hwang, S.D.;Cho, H.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.125-131
    • /
    • 2000
  • The local heat/mass transfer coefficients for arrays of impinging circular air jets on a plane surface are determined by means of the naphthalene sublimation method. Spent fluid makes a crossflow in the confined space. The crossflow reduces heat/mass transfer at the small gap distance between the jet plate and impingement surface because of reentrainment of the spent fluid. The present study suggests a new exhaust system having effusion holes in the impinging jet plate. The spent air flow out after impingement just through effusion holes located in the upper plate. This system increases heat/mass transfer coefficients and uniformity for small gap distances$(H/d{\leq}2)$

  • PDF

Lift-off and Flame Stability of a Coaxial Non-Premixed Jet Using Oxygen Enriched Air (산소부화공기를 이용한 동축 제트화염의 부상과 연소 안정성)

  • Kwark, Ji-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.326-331
    • /
    • 2003
  • Combustion using oxygen enriched air is known as a technology which can increase flame stability as well as thermal efficiency due to improvement of the burning rate. Lift-off, blowout limit and flame length were examined as a function of jet velocity, coflow velocity and OEC(Oxygen Enriched Concentration). Blowout limit of the flame below OEC 25% decreased with coflow velocity, but the limit above OEC 25% increased inversely. Lift-off height decreased with increase of OEC. Especially lift-off hardly occurred in the condition above OEC 40%. Flame length of the flames above OEC 40% was increased until the blowout occurred. Flame stability became improved since lift-off and blowout limit increased much with increase of OEC.

  • PDF

Heating type of die surface for removing weld line using high temperature air jet (웰드라인 제거를 위한 고온 기체 분사를 이용한 금형 표면의 가열기법)

  • Kim, Gyeong-Ha;Kim, Sun-Gyeong;Yu, Yeong-Eun;Jea, Tae-Jin;Choi, Du-Seon
    • Design & Manufacturing
    • /
    • v.2 no.2
    • /
    • pp.10-14
    • /
    • 2008
  • The application range of injection molded parts is expanding by the development of engineering plastics with good mechanical properties. Plastic products are specially used as automotive parts due to an excellent performance in the characteristics of a strength vs. weight. In this study, heating type of new method such as jet injection was applied to improve heat transfer coefficient is substituted for heating method of injection molding.

  • PDF

The Study of Jet Fan Control Logic for Longitudinal Ventilation in Road Tunnel (젯트팬 종류식 터널의 퍼지응용 제어로직에 관한 연구)

  • 유지오;남창호;신현준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.8
    • /
    • pp.763-770
    • /
    • 2000
  • In tunnel ventilation, the Purpose of ventilation control is to keep the required pollution level with minimum consumption of energy But tunnel ventilation has large disturbances caused by discharge of pollutants, traffic forces especially strong for longitudinal ventilation. Hence in this paper, the tunnel ventilation control logic applying fuzzy control theories is proposed and the simulation program of tunnel ventilation control is developed. The characteristics of longitudinal ventilation with jet fans are estimated and the effect of the proposed tunnel ventilation control is verified by the simulation program.

  • PDF