• 제목/요약/키워드: Air flow control

검색결과 1,019건 처리시간 0.022초

스로틀 개폐에 따른 가솔린 엔진의 비정상상태 유량변화 특성 (Characteristics of the Air Flow Variation by Throttle Step Change in a Gasoline Engine)

  • 박경석;고상근;노승탁;이종화
    • 한국자동차공학회논문집
    • /
    • 제4권3호
    • /
    • pp.92-101
    • /
    • 1996
  • In a gasoline engine, the characteristics of air flow is very important not only for the design of the intake system geometry bout also for the accurate measurement of the induction air mass. In this study, an air flow rate measurement of the induction air mass. In this study, an air flow rate measurement was conducted by using the hot wire flow meter at the upstream of the intake port and the throttle. At the upstream of the throttle, the overshoot phenomena of the air flow rate by fast throttle opening were analyzed with choked flow. At the upstream of the intake port, the cylinder variation of the air flow rate and the difference between fast throttle opening and closing were showed during the unsteady state by the throttle step change. The results of this study can be used for the design of the throttle valve geometry and cylinder by cylinder control.

  • PDF

On-site Performance Test and Simulation of a 10 RT Air Source Heat Pump

  • Baik, Young-Jin;Chang, Young-Soo;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.61-69
    • /
    • 2004
  • In this study, on-site performance test of an air source heat pump which has a rated capacity of 10 RT is carried out. Since indoor and outdoor air conditions can not be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. To estimate the performance of the heat pump for other conditions, the heat pump is modeled with a small number of characteristic parameters. The values of the parameters are determined from the few measurements measured on-site during steady operation. A simulation program is developed to calculate cooling capacity and power consumption at any other arbitrary operating conditions. The simulation results are in good agreement with the experiment. This study provides a method of an on-site performance diagnosis of an air source heat pump.

냉난방 시스템의 이중선형 시스템에 관한 제어기 설계 (A Controller Design of the Bilinear System for HVAC(Heating, Ventilating and Air-conditioning) System)

  • 이정석;강민수;김명호;이기서
    • 한국철도학회논문집
    • /
    • 제3권4호
    • /
    • pp.177-184
    • /
    • 2000
  • In this paper, a HVAC controller which has a bilinear system is designed to control the air temperature in building room and a saving of energy on the HVAC system. For modeling of the HVAC bilinear system, AHU(Air Handling Unit) is modeled on the control of inside-outside air flow using three dampers in a duct. A heat exchanger and the single room are also modeled by the energy conservation law. Under the modeling of the HVAC bilinear system, the control's law of the bilinear HVAC system is derived by Lyapunov's non-linear theory and Deress's the linear feedback laws for bilinear system. In this paper it was proved that the controller of the HVAC bilinear system is able to control the air temperature with a disturbance in order to get a target of temperature in the building room by the computer simulation when the control inputs regulate the air flow rate and a capacity of the heat exchanger.

  • PDF

공기측 입구헤더의 형상 개선을 통한 고분자 전해질 연료전지의 성능 향상 (Performance Enhancement of a PEMFC by Modification of Air Inlet Flow Header Configuration)

  • 김원년;김윤호;김서영
    • 설비공학논문집
    • /
    • 제19권4호
    • /
    • pp.339-345
    • /
    • 2007
  • In the present study, a 10-cell PEMFC stack with straight type cathode flow channels is employed to investigate the effect of inlet air flow header configuration on the overall fuel cell performance. Four different types of inlet flow headers are considered and the flow patterns according to the air inlet flow header configuration are numerically obtained. The computed result for a modified header predicts about 8.5% improvement in the air flow distribution at 10-cell cathode channel inlets. Experiments are also carried out to confirm the numerical findings by measuring actual air flow distributions and the polarization curves of the PEMFC stack.

구개열 환자에서의 구강인두압력 및 공기유량에 관한 음성학적 특징 (CHARACTERISTICS OF OROPHARYNGEAL AIR PRESSURE, AIRFLOW IN CLEFT PALATE PATIENTS)

  • 백진아
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권1호
    • /
    • pp.13-20
    • /
    • 2006
  • The articulation disorders associated with velopharyngeal insufficiency (VPI) in cleft palate patients are interested to clinicians particularly. The purpose of this study was to investigate mainly the oropharyngeal air pressure and overall air flow in cleft palate patients. The pressure-measuring catheter was positioned at the midportion of the oropharyngeal cavity with a facial mask. Test words were composed of 9 meaningless polysyllabic words and 17 meaningful words. Aerophone II and Nasometer II were used to measure peak air pressure, mean air pressure, maximum flow rate, volume, phonatory flow rate, nasalance. The data shows that airflow of the cleft palate patient group were higher than those of the control group. Intraoral air pressure of the cleft palate patient group was lower than those of the control group. The first vowel formant and first Bandwidths of the cleft palate patient group were higher than those of the control group.

온돌을 이용한 바닥복사냉방의 제어성능에 관한 실험적 연구 (An Experimental Study on Control Performance of Radiant Floor Cooling Using Ondol)

  • 김용이;임재한;한여명;김광우
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1165-1173
    • /
    • 2001
  • The objectives of this study are to analyze the application of radiant floor cooling and to evaluate the control methods through experiments when the radiant heating system is used for cooling. Through the experiment analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The cooling curve (reset ratio) is found for radiant cooling, which shows tole relation between outside air temperature and supply water temperature. Comparison of cooling methods shows that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

실별제어 온수분배기의 유량분배 특성 (A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System)

  • 성순경
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.

솔레노이드 가스 인젝터의 유량제어와 천연가스엔진에서의 응용 (Flow Control of a Solenoid Gas Injector and Its Application on a Natural Gas Engine)

  • 심한섭
    • 한국기계가공학회지
    • /
    • 제8권2호
    • /
    • pp.83-89
    • /
    • 2009
  • An air-fuel ratio control is essential in reducing hazardous exhaust emissions from a compressed natural gas(CNG) engine, and can be accomplished by accurate control of gas injection flow. In this study, theoretical research was conducted on injection characteristics of a solenoid gas injector, and injection experiments for calibration and analysis were performed. Various factors for gas injection flow such as injection pressure, gas temperature, and supply voltage are studied. A dynamic flow equation of the natural gas was proposed on the basis of flow dynamics theories and results of the injection experiment. The verification of the dynamic flow equation of the solenoid injector was carried out with a large CNG-engine applied to an urban bus. Air-fuel ratio control experiments were conducted in both steady and transient state. Results of injection experiments for the solenoid injector and the CNG-engine was proved the control method proposed herein to be effective.

  • PDF

Characteristics of Intraoral Air Pressure, Airflow in Relation to Phonatory Efficiency in Cleft Palate Speakers

  • Baek, Jin-A;Shin, Hyo-Keun
    • 대한음성언어의학회:학술대회논문집
    • /
    • 대한음성언어의학회 2003년도 제19회 학술대회
    • /
    • pp.147-147
    • /
    • 2003
  • Recent aerodynamic and acoustic studies of VPI(velopharyngeal insufficiency) are non-invasive and safety, therefore, many researchers have used it to diagnose the hyper/hyponasality and articulation disorders of cleft palate patients. The purpose of this study was to estimate mainly the oropharyngeal air pressure and over all air flow in cleft lip and palate patients. The pressure-collecting catheter was positioned in the oropharyngel cavity around tongue base. Twelve adult control group and three cleft lip & palate patients were participated to this experimentation. Aerophone II was used to measure peak air flow, mean air flow, phonatory airflow, phonatory efficiency and resistance. The results were as follows: 1) Airflow of cleft lip & palate patients group were higher than those of control group. Fricative sounds /s/ and /s'/ showed the statistic significance of mean airflow and volume data. 2) Intraoral air pressure of cleft lip & palate patients was lower than those of control group.

  • PDF

Measurement of suction air amount at reciprocating engine under stationary and transient operation

  • Kubota, Yuzuru;Hayashi, Shigenobu;Kajitani, Shuichi;Sawa, Norihiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1037-1042
    • /
    • 1990
  • The air-fuel ratio of an internal combustion engine must be controlled with accuracy for the improvements of exhaust emission and fuel consumption. Therefore, it is necessary to measure the exact instantaneous amounts of fuel and suction air, so we carried out the experiments for measuring the air flow velocity in a suction pipe of an internal combustion engine using three types of instantaneous air flowmeter. The results obtained can be summarized as follows: (1) The laminar-flow type flowmeter is able to measure both the average and the instantaneous flow rate, but it is necessary to rectify the pulsating air flow in the suction pipe. (2) The a spark-discharge type flow velocity meter is able to measure the instantaneous air velocity, but it is necessary to choose the suitable electrode form and the spark character. (3) The tandem-type hot-wire flow velocity meter indicates the instantaneous flow velocity and its flow direction.

  • PDF